Avviatori graduali Indice Generalità ............................................................................................................................... 7/2 Informazioni di dettaglio per l'ordinazione Serie PSS ................................................................................................................................ 7/4 Serie PST .............................................................................................................................. 7/12 FieldBusPlug .......................................................................................................................... 7/21 Informazioni aggiuntive Caratteristiche tecniche ......................................................................................................... 7/24 Dimensioni di ingombro ......................................................................................................... 7/30 Schemi di collegamento ......................................................................................................... 7/32 7 7/1 Cap_7.p65 1 3/9/04, 4:28 PM Avviatori graduali Generalità Dal momento in cui sul mercato sono stati introdotti i primi motori elettrici, i progettisti hanno cercato un modo per evitare i problemi elettrici e meccanici associati all’uso degli avviatori in linea diretti (DOL) e degli avviatori stella-triangolo. ABB ha iniziato a produrre avviatori graduali dai primi anni ’80 acquisendo una vasta e approfondita esperienza. Con la serie più recente, denominata PST, ABB compie un nuovo e significativo progresso nella tecnologia dell’avviamento graduale. Abbinando la moderna elettronica di potenza e sistemi di circuiti “intelligenti”, gli avviatori graduali PST offrono un controllo elettronico di corrente e tensione più efficiente durante le fasi di avviamento del motore, oltre a numerose nuove funzioni. La soluzione unica ai problemi elettrici e meccanici dell’avviamento I motori elettrici in corrente alternata – utilizzati ampiamente nell’industria per azionare macchine di vario genere, tra cui ventole, frantumatori, mescolatori, pompe e trasportatori – sono spesso all’origine di picchi di carico indesiderati negli impianti di produzione. I danni provocati da questi bruschi avviamenti comprendono: ● problemi elettrici dovuti a tensioni e correnti transitorie prodotte da avviatori in linea diretti (DOL) e avviatori stella-triangolo, che possono sovraccaricare la rete di alimentazione locale e causare oscillazioni di tensione inaccettabili poiché in grado di interferire con altre apparecchiature elettriche collegate alla rete ● problemi meccanici che interessano l’intera catena di azionamento, dal motore alle apparecchiature di utilizzo azionate, con l’applicazione di pesanti sollecitazioni ● problemi di esercizio, quali sovrapressioni in condotte, danneggiamento di prodotti su nastri trasportatori e marcia disagevole su scale mobili o ascensori. Le conseguenze economiche sono rilevanti: ogni problema tecnico e ogni guasto o rottura di componenti ha un costo specifico in termini di riparazioni e perdite di produttività. La soluzione semplice a tutti questi problemi è rappresentata dall’installazione di un avviatore graduale ABB di tipo PSS o PST. Con gli avviatori graduali di ABB, ogni avviamento o arresto di motore può essere effettuato con semplicità ed efficienza, riducendo al minimo le sollecitazioni elettriche e meccaniche applicate. 7 Tensione del motore V Corrente del motore Avviamento Avviamento Avviamento in linea diretto stella/ graduale (DOL) triangolo 100% I Avviamento in linea diretto (DOL) Coppia T Avviamento stella/triangolo Avviamento stella/triangolo 70% 58% Rampa 30% Avviamento in linea diretto (DOL) Avviamento graduale Avviamento graduale regolabile Tempo Velocità del motore Velocità del motore I grafici illustrano le differenze di base tra lavviamento in linea diretto (DOL), lavviamento stella-triangolo e lavviamento graduale nei valori di tensione (V), di corrente (I) e di coppia del motore (T) 7/2 Cap_7.p65 2 3/9/04, 4:28 PM Avviatori graduali Generalità Avviatori graduali di ABB: una gamma completa ABB offre tre diversi tipi di avviatori graduali per rispondere alle esigenze di ogni cliente nelle applicazioni da 3 A a 1810 A. Nel prospetto riepilogativo sono illustrate le caratteristiche principali dei diversi modelli. Per maggiori dettagli tecnici e le informazioni per gli ordini, si rimanda alle pagine successive. PST30 ... PSTB1050 Una nuova gamma di avviatori PST per correnti del motore da 30 a 1810 A, che offre numerose funzionalità avanzate di avviamento graduale. Protezioni d’avanguardia integrate: per il motore, un relè di sovraccarico elettronico integrato, relè per controllo di fase, protezione PTC e protezione da correnti elevate; per l’avviatore graduale, una protezione tiristori avanzata. Sistema bus di comunicazione flessibile: utilizzando il sistema di comunicazione FieldBusPlug (FBP) di ABB, si può decidere in qualunque momento quale sistema di bus scegliere nella gamma di ABB. L’interfaccia tra l’avviatore graduale PST e il sistema FBP di ABB è sempre la stessa, indipendentemente dalle dimensioni e dai successivi ampliamenti dell’installazione. Display LCD: di facile impiego grazie al menu in 10 lingue assimilabile a quello di un telefono cellulare, alle impostazioni applicative preprogrammate e al logging automatico di status e di eventi. Relè programmabili di segnalazione: offrono numerose funzionalità di allarme per guasti o altri eventi. ● ● PSS3 ... 25 Una gamma di avviatori per correnti del motore da 3 a 25 A, che offre i vantaggi di una soluzione: compatta grazie alle dimensioni contenute dell’avviatore, con lo spazio per un maggior numero di prodotti sulla superficie di montaggio; ● facile da installare poiché il dispositivo si monta a scatto su profilato DIN e riporta sul frontale istruzioni chiare per l’installazione. ● PSS18 ... 300 Una gamma di avviatori per correnti del motore da 18 a 515 A, che offre una soluzione adattabile a quasi ogni genere di applicazione, con tutti i vantaggi di un sistema: ● ● flessibile poiché l’avviatore offre due possibili modalità di collegamento, in linea con il motore o internamente al triangolo e l’opportunità di inserire un limite di corrente; ● facile da installare grazie ai tre selettori rotanti chiaramente contrassegnati sul frontale dell’unità, con cui regolare l’avviatore PSS per una vasta gamma di applicazioni; ● con circuito elettrico a stato solido per garantire la massima affidabilità e ridurre al minimo la manutenzione, anche in applicazioni che comportano avviamenti e arresti frequenti. ● PS S0 3. .. 2 5 PS S1 8/3 0. PS .. 3 T3 00 0. /51 .. 1 5 05 0 Da 3 A a 1810 A Funzionalità Serie PST avanzata 60 – 1810 A 30 – 1050 A A richiesta Non disponibile ● Comunicazione fieldbus abilitata ● Orologio in tempo reale ● Funzioni programmabili di supervisione per guasti ● Funzioni programmabili di allarme per guasti ● Ingresso PTC di protezione motore ● Protezione da correnti elevate ● Protezione da sbilanciamento di fase/inversione di fase ● Protezione da rotore bloccato ● Protezione da sovratemperatura dei tiristori ● Protezione da sovraccarico del motore ● Tastiera a quattro pulsanti (In linea) flessibile 30 – 515 A Di serie O (In triangolo) Serie PSS 18 – 300 A ● (In triangolo) (In linea) (tastiera esterna disponibile a partire dal 2004) Serie PSS compatta 3 – 25 A Corrente a pieno carico (A) O ● Controllo per limite di corrente ● ● Collegamento in linea e in triangolo ● ● ● LED di segnalazione ● ● 1) Contattore di by-pass integrato ● ● ● Avvio/arresto rampa 1) Sui modelli PSTB 7/3 Cap_7.p65 3 3/9/04, 4:28 PM 7 Avviatori graduali PSS Informazioni di dettaglio per l'ordinazione PSS03, PSS12 PSS25 PSS18/30 ... PSS44/76 PSS03 ... PSS25 PSS18/30 ... PSS44/76 Avviamento normale, 400 V Collegamento in linea kW Collegamento in triangolo kW 1,1 kW - 5,5 kW - 11 kW - 7,5 kW 15 kW 15 kW 25 kW 18,5 kW 30 kW 22 kW 37 kW Tipo 400 V 480 V 690 V PSS03 ● ● – PSS12 ● ● – PSS25 ● ● – PSS18/30 ● ● ● PSS30/52 ● ● ● PSS37/64 ● ● ● PSS44/76 ● ● ● 3,5 12 25 18 30 37 44 170M1363 170M1364 170M1364 170M1366 170M1368 170M1369 A12 A26 A26 A30 A40 A50 TA42DU TA75DU Corrente nominale ,A Ie Protezione con fusibile 400 V, 65 kA Tipo Bussmann 170M1359 Sezionatore con fusibile Tipo OS160RD0380 Contattore di linea Tipo A9 Relè termico di sovraccarico Tipo TA25DU Trasformatori di corrente 7 Tipo PSCT-60 PSCT-40 PSCT-50 PSCT-60 2 spire 1 spira 1 spira 1 spira A9 A16 A26 A26 Contattore di by-pass Tipo Scelta della taglia corretta Guida rapida alla scelta dell’avviatore La tabella permette di scegliere in modo semplice e rapido lavviatore Avviamento normale Classe 10 Avviamento pesante Classe 30 Applicazioni tipiche Applicazioni tipiche graduale appropriato per le applicazioni più comuni. Per una scelta più accurata, si può utilizzare ● il software Prosoft disponibile gratuitamente nel sito www.abb.com/lowvoltage. Eliche di manovra ● Pompe centrifughe per imbarcazioni ● Nastri trasportatori (corti) ● Frantumatori ● Mulini ● Scale mobili ● Mescolatori ● Agitatori ● Compressori ● Ascensori ● centrifughi Scelta standard Tipo PSS Taglia conforme alla potenza nominale del motore. Tipo PSS Scegliere Una taglia più grande della potenza nominale del motore. Per oltre 10 avviamenti/ora una taglia più grande rispetto alla soluzione standard 7/4 4 Nastri trasportatori (lunghi) Scelta standard ! Cap_7.p65 ● Ventilatori 3/9/04, 4:28 PM Avviatori graduali PSS Informazioni di dettaglio per l'ordinazione PSS50/85 ... PSS72/124 PSS85/147 ... PSS142/245 PSS175/300 ... PSS300/515 PSS50/85 ... PSS72/124 PSS85/147... PSS142/245 PSS175/300 ... PSS300/515 25 kW 45 kW 30 kW 55 kW 37 kW 59 kW 45 kW 75 kW 55 kW 90 kW 75 kW 132 kW 90 kW 160 kW 132 kW 220 kW 160 kW 257 kW PSS50/85 ● ● ● PSS60/105 ● ● ● PSS72/124 ● ● ● PSS85/147 ● ● ● PSS105/181 ● ● ● PSS142/245 ● ● ● PSS175/300 ● ● ● PSS250/430 ● ● ● PSS300/515 ● ● ● 50 60 72 85 105 142 175 250 300 170M1372 170M3020 170M3021 170M4016 170M4017 Protezione con fusibile 170M1369 170M1370 400 V, 65 kA 170M1371 170M1371 Sezionatore con fusibile OS160RD0380 OESA250R03D80 OESA400R03D80 Contattore di linea A50 A63 A75 A95 A110 A145 A185 A260 A300 Relè termico di sovraccarico TA75DU TA110DU TA200DU TA450DU Trasformatori di corrente 7 PSCT-75 PSCT-100 PSCT-125 PSCT-150 PSCT-200 PSCT-250 PSCT-400 1 spira 1 spira 1 spira 1 spira 1 spira 1 spira 1 spira A50 A63 A75 A110 A145 Contattore di by-pass A30 A40 A50 A210 Informazioni per gli ordini Nella trasmissione di un ordine, occorre indicare il “Codice d’ordine”. “Tipo” o il Per alcuni prodotti, è necessario inserire particolari codici in lettere/cifre per definire il tipo/codice dordine completo. Imballaggio Tutti gli avviatori graduali e la maggior parte degli accessori sono imballati singolarmente. Alcuni accessori sono imballati insieme in lotti di n pezzi indicati nelle tabelle dei codici. Per questi articoli, occorre ordinare una quantità complessiva corrispondente a un multiplo del numero di pezzi contenuti nellimballaggio. Esempio: se ci sono due pezzi nellimballaggio, occorre trasmettere un ordine minimo di due, quattro, sei pezzi, ecc. Nota: ogni Tipo o Codice dordine corrisponde sempre a un solo pezzo. 7/5 Cap_7.p65 5 3/9/04, 4:28 PM PSS03 ... PSS25 Informazioni di dettaglio per l'ordinazione Applicazione Pannelli di controllo PSS25 Gli avviatori graduali tipo PSS03 ... PSS25 offrono una soluzione compatta per l’avviamento di piccoli motori. Le unità sono semplici da installare e da regolare grazie all’accesso per i collegamenti e per le impostazioni dal lato frontale. Sono predisposte per il montaggio su profilato DIN. PSS03 … PSS12 Caratteristiche Correnti nominali 3, 12 e 25 A Tensione principale 230, 400, 480 - 500 e 600 V ● Campo della tensione di comando 24-110 V AC/DC e 110-480 V AC ● Impostazioni per la rampa di avviamento, la rampa di arresto e la tensione iniziale ● Montaggio su profilato DIN da 35 mm ● Contatti di by-pass integrati ● 1SFT 98899-030 Tre potenziometri per: PSS03 ... PSS12 1SFT 98899-043 ● PSS25 - rampa di avviamento - rampa di arresto - tensione iniziale Accesso dal frontale per i collegamenti Marcature chiare Montaggio su profilato DIN Contatti di by-pass integrati LED di segnalazione Presenza tensione LED di segnalazione Rampa di salita/discesa Presenza tensione (lampeggiante) Marcia/by-pass Rampa di avviamento Rampa di avviamento completata completata Guasto generico 7 230 – 600 V Potenza del motore 230 V 400 V 500 V 600 V Pe Pe Pe Pe kW kW kW kW Corrente nominale del motore, Ie A 0,75 - - - 3,5 3,0 - - - 12 6,5 - - - 25 - 1,1 - - 3,5 5,5 - - 12 PSS03 PSS12 11,0 - - 25 - - 1,5 - 3,5 - - 5,5 - 12 - - 15,0 - 25 - - - 7,5 12 - - - 18,5 25 1) Tipo 1) PSS03-220B PSS12-220B PSS25-220B 1SFA 891 001 R2209 1SFA 891 002 R2209 1SFA 891 003 R2209 PSS03-400B PSS12-400B PSS25-400B 1SFA 891 001 R4009 1SFA 891 002 R4009 1SFA 891 003 R4009 PSS03-480B PSS12-480B PSS25-480B PSS12-600B PSS25-600B 1SFA 891 1SFA 891 1SFA 891 1SFA 891 1SFA 891 Tensione di comando, Uc Tipo V, AC/DC V, AC 220B 24-110 110-230 400B 24-110 110-400 480B 24-110 110-500 600B 24-110 110-500 PSS25 7/6 Cap_7.p65 6 Peso kg Codice d'ordine 3/9/04, 4:28 PM 001 002 003 002 003 R4809 R4809 R4809 R6009 R6009 0,27 0,27 0,60 0,27 0,27 0,60 0,27 0,27 0,60 0,27 0,60 PSS18/30 ... PSS300/515 Informazioni di dettaglio per l'ordinazione Pannelli di controllo Applicazione La gamma di avviatori graduali PSS18/30 ... PSS300/515 rappresenta una soluzione altamente flessibile per la maggior parte delle applicazioni e per l’utilizzo in sostituzione di avviatori stella-triangolo. La possibilità di collegamento all’interno del triangolo motore (rispetto al collegamento per gli avviatori stella-triangolo standard) permette di ridurre del 42% la corrente che attraversa l’avviatore. Questo significa che con un avviatore graduale PSS da 58 A, per esempio, è possibile azionare un motore elettrico da 100 A. In linea In triangolo 100 A 1SFT 98899-031 58 A 100 A 100 A Collegamento in linea e in triangolo degli avviatori PSS18/30 PSS300/515 Lavviatore graduale PSS può essere scelto in base alla potenza nominale del motore in applicazioni con cicli di avviamento/arresto normali, ad esempio pompe, compressori, ascensori, scale mobili, nastri trasportatori corti ed eliche di manovra per imbarcazioni. Per applicazioni con cicli di avviamento/arresto ventilatori centrifughi, frantumatori, gravosi, ad esempio mescolatori, agitatori e nastri trasportatori lunghi, si consiglia di scegliere un avviatore graduale di una taglia più grande rispetto alla potenza nominale del motore. Consultare anche la tabella a pag. 7/4. Caratteristiche ● ● ● ● ● ● ● ● ● ● Ampio campo della tensione principale 208 - 690 V AC Campo della tensione di alimentazione 110-120 V AC e 220-240 V AC Corrente nominale 18 ... 300 A (in linea) e 30 ... 515 A (in triangolo) Stessa unità utilizzabile per il collegamento in linea e per il collegamento in triangolo Rampa di avviamento, rampa di arresto e tensione iniziale incluse Limitazione di corrente accessoria su richiesta Circuito elettrico a stato solido Possibilità di funzionamento continuo senza by-pass Capacità in sovracorrente pari al 15% nella marcia continua (10% per il modello PSS300) Accessori disponibili per il collegamento e l’installazione: consultare le pagine relative agli ordini 7 Relè integrati di segnalazione per guasto e by-pass Copertura trasparente di protezione delle impostazioni Impostazioni dei tre selettori rotanti: - rampa di avviamento (130 sec) LED di segnalazione - rampa di arresto (030 sec) Presenza di tensione - tensione iniziale (3070% di Ue) - limite di corrente 1,5 4 x Ir Rampa di avviamento completata (eventualmente, tensione iniziale fissata Guasto generico (unità o lato motore) al 40% della Ue) Guasto esterno Dip-switch per il collegamento in linea/in triangolo 7/7 Cap_7.p65 7 3/9/04, 4:28 PM PSS18/30 ... PSS300/515 per avviamenti normali in linea Informazioni di dettaglio per l'ordinazione 230 – 500 V Potenza del motore PSS18/30-500 ... 44/76-500 PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690 PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690 400 V 500 V 690 V Pe Pe Pe kW kW kW Corrente nominale del motore, Ie A 7,5 11 - 18 15 18,5 - 30 18,5 22 - 37 22 25 - 44 25 30 - 50 30 37 - 60 37 45 - 72 45 55 - 85 55 75 - 105 75 90 - 142 90 110 - 175 132 160 - 250 160 200 - 300 PSS18/30-500■■ PSS30/52-500■■ PSS37/64-500■■ PSS44/76-500■■ PSS50/85-500■■ PSS60/105-500■■ PSS72/124-500■■ PSS85/147-500■■ PSS105/181-500■■ PSS142/245-500■■ PSS175/300-500■■ PSS250/430-500■■ PSS300/515-500■■ Tipo PSS18/30-690■■ PSS30/52-690■■ PSS37/64-690■■ PSS44/76-690■■ PSS50/85-690■■ PSS60/105-690■■ PSS72/124-690■■ PSS85/147-690■■ PSS105/181-690■■ PSS142/245-690■■ PSS175/300-690■■ PSS250/430-690■■ PSS300/515-690■■ 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 400 V 500 V 690 V Pe Pe Pe kW kW kW Corrente nominale del motore, Ie A 7,5 15 18,5 22 25 30 37 45 55 75 90 132 160 11 18,5 22 25 30 37 45 55 75 90 110 160 200 15 25 30 37 45 55 59 75 90 132 160 220 257 18 30 37 44 50 60 72 85 105 142 175 250 300 *) Aggiungere i seguenti codici in lettere sotto Tipo per: - tensione di alimentazione, Uc ■ F = 110-120 V, 50/60 Hz L = 220-240 V, 50/60 Hz ■ nessun codice in lettere = NA C = NC Codice d'ordine **) 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ 2,30 2,30 2,30 2,30 3,60 3,80 3,80 8,60 10,40 10,40 20,50 22,00 22,00 Consultare la tabella a pag. 893 893 893 893 893 893 893 893 893 893 893 893 893 001 002 003 004 005 006 007 008 009 010 011 013 014 Peso kg **) R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ Aggiungere i seguenti codici numerici sotto Codice d’ordine per: - tensione di alimentazione, Uc ▼ 1 = 110-120 V, 50/60 Hz 2 = 220-240 V, 50/60 Hz - relè di segnalazione per guasto ▼ 1 = NA 2 = NC Scelta della taglia corretta per avviamenti gravosi 7/4 7/8 8 001 002 003 004 005 006 007 008 009 010 011 013 014 Potenza del motore - relè di segnalazione per guasto Cap_7.p65 892 892 892 892 892 892 892 892 892 892 892 892 892 Peso kg **) PSS175/300-690 ... 300/515-690 Codice d'ordine PSS175/300-500 ... 300/515-500 *) 400 – 690 V *) 7 Tipo 3/11/04, 4:13 PM 2,30 2,30 2,30 2,30 3,60 3,80 3,80 8,60 10,40 10,40 20,50 22,00 22,00 PSS18/30 ... PSS300/515 per avviamenti normali in linea Informazioni di dettaglio per l'ordinazione 230 – 500 V Potenza del motore PSS18/30-500 ... 44/76-500 PSS50/85-500 ... 72/124-500 PSS18/30-690 ... 72/124-690 PSS85/147-500 ... 142/245-500 PSS85/147-690 ... 142/245-690 400 V 500 V 690 V Pe Pe Pe kW Corrente nominale del motore, Ie A kW kW Tipo 15 25 30 37 45 55 59 75 90 132 160 220 257 18,5 30 37 45 55 75 80 90 110 160 200 295 355 - 30 52 64 76 85 105 124 147 181 245 300 430 515 PSS18/30-500■■ PSS30/52-500■■ PSS37/64-500■■ PSS44/76-500■■ PSS50/85-500■■ PSS60/105-500■■ PSS72/124-500■■ PSS85/147-500■■ PSS105/181-500■■ PSS142/245-500■■ PSS175/300-500■■ PSS250/430-500■■ PSS300/515-500■■ *) 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 001 002 003 004 005 006 007 008 009 010 011 013 014 R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ 2,30 2,30 2,30 2,30 3,60 3,80 3,80 8,60 10,40 10,40 20,50 22,00 22,00 Potenza del motore 400 V 500 V 690 V Pe Pe Pe Corrente nominale del kW kW kW motore, Ie A Tipo 15 25 30 37 45 55 59 75 90 132 160 220 257 18,5 30 37 45 55 75 80 90 110 160 200 295 355 25 45 55 59 75 90 110 132 160 220 257 400 500 30 52 64 76 85 105 124 147 181 245 300 430 515 PSS18/30-690■■ PSS30/52-690■■ PSS37/64-690■■ PSS44/76-690■■ PSS50/85-690■■ PSS60/105-690■■ PSS72/124-690■■ PSS85/147-690■■ PSS105/181-690■■ PSS142/245-690■■ PSS175/300-690■■ PSS250/430-690■■ PSS300/515-690■■ Peso *) 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA - relè di segnalazione per guasto nessun codice in lettere = NA C = NC 893 893 893 893 893 893 893 893 893 893 893 893 893 001 002 003 004 005 006 007 008 009 010 011 013 014 R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ R▼00▼ kg 2,30 2,30 2,30 2,30 3,60 3,80 3,80 8,60 10,40 10,40 20,50 22,00 22,00 Aggiungere i seguenti codici in lettere sotto Tipo per: - tensione di alimentazione, Uc ■ F = 110-120 V, 50/60 Hz L = 220-240 V, 50/60 Hz ■ **) Codice d'ordine PSS175/300-690 ... 300/515-690 892 892 892 892 892 892 892 892 892 892 892 892 892 Peso kg 400 – 690 V *) PSS175/300-500 ... 300/515-500 **) Codice d'ordine **) 7 Aggiungere i seguenti codici numerici sotto Codice d’ordine per: - tensione di alimentazione, Uc ▼ 1 = 110-120 V, 50/60 Hz 2 = 220-240 V, 50/60 Hz - relè di segnalazione per guasto ▼ 1 = NA 2 = NC Scelta della taglia corretta per avviamenti gravosi Consultare la tabella a pag. 7/4 7/9 Cap_7.p65 9 3/11/04, 4:13 PM Accessori per PSS18/30 ... PSS300/515 Informazioni di dettaglio per l'ordinazione Trasformatori amperometrici per la limitazione di corrente Da collegare ai morsetti 11 e 12 dell’avviatore graduale. Il campo di regolazione (1,5 – 4) corrisponde a un multiplo del rapporto di trasformazione. I dati tecnici riportati sotto indicano il rapporto di trasformazione e il numero di spire dell’avvolgimento primario. È possibile utilizzare anche trasformatori amperometrici di altri produttori purché il rapporto di trasformazione sia quello indicato con minimo 1 VA. PSCT.. Per avviatori graduali tipo Rapporto di trasformazione Numero di spire Tipo PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515 60/1 – 2 spire 60/1 – 1 spira 60/1 – 1 spira 60/1 – 1 spira 75/1 – 1 spira 75/1 – 1 spira 100/1 – 1 spira 125/1 – 1 spira 150/1 – 1 spira 200/1 – 1 spira 250/1 – 1 spira 400/1 – 1 spira 400/1 – 1 spira PSCT-60 PSCT-40 PSCT-50 PSCT-60 PSCT-75 PSCT-75 PSCT-100 PSCT-125 PSCT-150 PSCT-200 PSCT-250 PSCT-400 PSCT-400 Codice d'ordine Confezione Pezzi Peso kg 1 pz 1SFA 899 001 R1060 1SFA 899 001 R1040 1SFA 899 001 R1050 1SFA 899 001 R1060 1SFA 899 001 R1075 1SFA 899 001 R1075 1SFA 899 001 R1100 1SFA 899 001 R1125 1SFA 899 001 R1150 1SFA 899 001 R1200 1SFA 899 001 R1250 1SFA 899 001 R1400 1SFA 899 001 R1400 1 1 1 1 1 1 1 1 1 1 1 1 1 0,30 0,30 0,30 0,30 0,30 0,30 0,25 0,25 0,25 0,25 0,25 0,25 0,25 Codice d'ordine Confezione Pezzi Peso kg 1 pz 1SFT98099-095C2 Per avviatori graduali tipo Sezione dei cavi mm2 Coppia di serraggio max. Nm PSS85/147 … 142/245 6-120 16 PSS85/147 … 142/245 2x(50-120) 16 PSS175/300 … 300/515 16-240 25 Tipo – 1SDA 023 354 R0001 3 LZ185-2C/120 1SFN 074 709 R1000 3 – 1SDA 023 368 R0001 3 Per avviatori graduali tipo LZ... Sezione dei cavi mm2 PSS85/147 … 142/245 35-95 PSS85/147 … 142/245 25-150 PSS175/300 … 300/515 120-240 Coppia di serraggio max. Nm Tipo Codice d'ordine 13,5 31 43 – – – 1SDA 023 356 R0001 3 1SDA 023 357 R0001 3 1SDA 023 370 R0001 3 7 7/10 Cap_7.p65 0,20 0,30 0,40 Connettori per cavi Al e Cu SB854C2 1SFT98099-011C1 Connettori per cavi Cu 10 3/9/04, 4:28 PM Confezione Pezzi Peso kg 1 pz 0,10 0,10 0,10 Accessori per PSS18/30 ... PSS300/515 Informazioni di dettaglio per l'ordinazione LT ... -AC 1SFT98099-125 1SFT98099-019C3 Calotte coprimorsetti LT ... -AL Per avviatori graduali tipo Idonee per Tipo PSS85/147 … 142/245 PSS85/147 … 142/245 PSS175/300 … 300/515 PSS175/300 … 300/515 Connettori per cavi Capicorda a pressione Connettori per cavi Capicorda a pressione LT185-AC LT185-AL LT300-AC LT300-AL Codice d'ordine Confezione Pezzi Peso kg 1 pz 1SFN 1SFN 1SFN 1SFN 2 2 2 2 0,10 0,10 0,20 0,20 Confezione Pezzi Peso kg 1 pz 124 701 R1000 124 703 R1000 125 101 R1000 125 103 R1000 Bulloni di fissaggio LE185 Per avviatori graduali tipo Tipo Codice d'ordine PSS85/147 … 142/245 PSS175/300 … 300/515 LE185 LE300 1SFN 074 716 R1000 2 1SFN 075 116 R1000 2 0,20 0,30 Estensioni morsetti 1SFT98000-011C3 PSLW-44 LW... Per avviatori graduali tipo Sezione dei cavi mm2 Tipo PSS18/30-500 ... 44/76-500 1x6 ... 35 2x6 ... 16 Codice d'ordine Confezione Pezzi Peso kg 1 pz PSLW-44 1SFA 899 002 R1044 1 0,10 PSS50/85-500 … 72/124-500 PSS18/30-690 ... 72/124-690 1x10 ... 50 2x10 ... 25 PSLW-72 1SFA 899 002 R1072 1 0,15 PSS85/147 … 142/245 PSS175/300 … 300/515 LW185 LW300 1SFA 074 707 R1000 1SFA 075 107 R1000 1 1 0,25 0,40 7 7/11 Cap_7.p65 11 3/9/04, 4:28 PM Avviatori graduali PST 1SFC132013F0201 1SFC132017F0201 Informazioni di dettaglio per l'ordinazione PST30 ... PST72 PST85 ... PST142 PST30 ... PST72 PST85 ... PST142 Avvio normale, 400 V Collegamento in linea kW Collegamento in triangolo kW 15 kW 25 kW 18.5 kW 30 kW 22 kW 37 kW 25 kW 45 kW 30 kW 55 kW 37 kW 59 kW 45 kW 75 kW 55 kW 90 kW 75 kW 132 kW Tipo 400 V 500 V 690 V PST30 ● ● ● PST37 ● ● ● PST44 ● ● ● PST50 ● ● ● PST60 ● ● ● PST72 ● ● ● PST85 ● ● ● PST105 ● ● ● PST142 ● ● ● 30 37 44 50 60 72 85 105 142 170M1369 170M1369 170M1370 170M1371 170M1372 170M3019 170M3020 Corrente nominale Ie, A Protezione con fusibili 400 V, 65 kA Tipo Bussmann 170M1366 170M1368 Sezionatore con fusibile Tipo OS160RD0380 OESA250R03D80 Contattore di linea Tipo A30 A40 A50 A50 A63 A75 A95 A110 A145 A16 A26 A26 A30 A40 A50 A50 A63 A75 Contattore di by-pass Tipo 7 Scelta della taglia corretta Guida rapida alla scelta dell’avviatore La tabella permette di scegliere in modo semplice e rapido lavviatore Avviamento normale Classe 10 Avviamento pesante Classe 30 Applicazioni tipiche Applicazioni tipiche graduale appropriato per le applicazioni più comuni. Per una scelta più accurata, si può utilizzare ● il software Prosoft disponibile gratuitamente nel sito www.abb.com/lowvoltage. Eliche di manovra ● Pompe centrifughe per imbarcazioni ● Nastri trasportatori (corti) ● Frantumatori ● Mulini ● Scale mobili ● Mescolatori ● Agitatori ● Compressori ● Ascensori ● centrifughi Scelta standard Tipo PSS Taglia conforme alla potenza nominale del motore. Tipo PSS Una taglia più grande della potenza nominale del motore. Per oltre 10 avviamenti/ora Scegliere una taglia più grande rispetto alla soluzione standard 7/12 12 Nastri trasportatori (lunghi) Scelta standard ! Cap_7.p65 ● Ventilatori 3/9/04, 4:29 PM Avviatori graduali PST Informazioni di dettaglio per l'ordinazione PSTB570 ... PSTB1050 PST175 ... PST300 1SFC132014F0201 1SFC132018F0201 PSTB370 ... PSTB470 1SFC132015F0201 PST175 ... PST300 PSTB370 ... PSTB470 PSTB570 ... PSTB1050 90 kW 160 kW 110 kW 184 kW 132 kW 220 kW 160 kW 257 kW 200 kW 355 kW 250 kW 450 kW 315 kW 475 kW 400 kW 670 kW 450 kW 780 kW 560 kW 875 kW PST175 ● ● ● PST210 ● ● ● PST250 ● ● ● PST300 ● ● ● PSTB370 ● ● ● PSTB470 ● ● ● PSTB570 ● ● ● PSTB720 ● ● ● PSTB840 ● ● ● PSTB1050 ● ● ● 175 210 250 300 370 470 570 720 840 1050 170M5012 170M5013 170M5015 170M5013 170M5015 170M6015 170M5018 170M6018 170M6020 170M3021 OESA250RD0380 OESA400R03D80 OESA630R03D80 OESA800R03D80 2) 2) A185 A210 A260 A300 AF400 AF460 AF580 AF750 – – A110 A145 A145 A210 Integrato Integrato Integrato Integrato Integrato Integrato 1) 2) 1) PST1050-690-70 con protezione fusibile 170M6019. PSTB840 e PSTB1050: sezionatore con fusibile non disponibile, utilizzare un portafusibile (v. pag. 7/29). 7 Informazioni per gli ordini “Tipo” “Codice d’ordine”. Per alcuni prodotti, è necessario inserire Nella trasmissione di un ordine, occorre indicare il o il particolari codici in lettere/cifre per definire il tipo/codice dordine completo. Imballaggio Tutti gli avviatori graduali e la maggior parte degli accessori sono imballati singolarmente. Alcuni accessori sono imballati insieme in lotti di n pezzi indicati nelle tabelle dei codici. Per questi articoli, occorre ordinare una quantità complessiva corrispondente a un multiplo del numero di pezzi contenuti nellimballaggio. Esempio: se ci sono due pezzi nellimballaggio, occorre trasmettere un ordine minimo di due, quattro, sei pezzi, ecc. Nota: ogni Tipo o Codice dordine corrisponde sempre a un solo pezzo. 7/13 Cap_7.p65 13 3/9/04, 4:29 PM PST30 ... 300 e PSTB370 ... 1050 Informazioni di dettaglio per l'ordinazione Applicazione Caratteristiche La gamma PST comprende avviatori graduali con funzionamento basato su microprocessore. Progettati in base alla più avanzata tecnologia per l’avviamento e l’arresto graduale dei motori, sono forniti di serie con numerose funzioni avanzate di protezione del motore. La tastiera a quattro pulsanti e la struttura logica del menu di programmazione semplificano l’installazione, la messa in servizio e il funzionamento del sistema, permettendo inoltre di scegliere tra 10 lingue diverse. Gli avviatori graduali PST possono essere utilizzati con o senza contattore di by-pass, a eccezione delle taglie più grandi (PTB370 ... PSTB1050) in cui il contattore di by-pass è già integrato. ● Ampio campo di tensione principale 208 - 690 V AC ● Ampio campo di tensione di alimentazione 100 – 250 V, 50/60 Hz ● Corrente nominale da 30 a 1050 A (in linea) e 52 ... 1810 A (in triangolo) ● La stessa unità può essere utilizzata sia per il collegamento in linea sia per il collegamento in triangolo ● Funzioni superiori regolabili tra cui rampa di avviamento/arresto, ● ● Gli avviatori graduali PST possono essere scelti in base alla potenza nominale del motore in applicazioni con cicli di avviamento/arresto normali, ad esempio pompe, compressori, ascensori, scale mobili, nastri trasportatori corti ed eliche di manovra per imbarcazioni. Per applicazioni con cicli di avviamento/arresto gravosi, ad esempio ● ● ● ● ventilatori centrifughi, frantumatori, mescolatori, mulini, agitatori e nastri trasportatori lunghi, si raccomanda di scegliere un avviatore graduale di una taglia più grande rispetto alla potenza nominale del motore. *Consultare anche la tabella a pag. ● ● 7/14 In linea ● ● avviamento con booster (kick start), avviamento a impulsi (jog), tensione ridotta e avviamento in sequenza Limite di corrente regolabile tra 2–5 x Ie Supervisione dell’avvolgimento motore a termistori (PTC) Orologio in tempo reale Logging degli ultimi 20 eventi con marcatura del tempo Predisposizione per comunicazione fieldbus Protezione da sovraccarico del motore con simulazione della temperatura motore dalla corrente misurata (scegliere tra le classi di intervento delle protezioni termiche 10A, 10, 20 e 30) Protezione da rotore bloccato Protezione di minimo carico del motore Protezione da sbilanciamento di fase Protezione da inversione di fase In triangolo 100 A 58 A 100 A 100 A Collegamento in linea e in triangolo degli avviatori PST 30 1050 Ingressi segnali programmabili Tre morsetti per by-pass esterno separati Relè programmabili di segnalazione Display LCD con termini semplici nella lingua selezionata 7 Tastiera a quattro pulsanti Protezione del motore (integrata) LED di segnalazione Presenza tensione Guasto Protezione Informazioni chiare Morsetti per PTC Comunicazione fieldbus 7/14 Cap_7.p65 14 3/9/04, 4:29 PM PST30 ... 300 e PSTB370 ... 1050 Informazioni di dettaglio per l'ordinazione Display LCD Il display degli avviatori PST visualizza le informazioni richieste in termini semplici e nella lingua selezionata dall’utilizzatore scegliendo tra inglese, tedesco, italiano, cinese, finlandese, svedese, francese, spagnolo, olandese e portoghese. Il display visualizza tutte le informazioni utili o necessarie per l’installazione, la regolazione e le funzioni diagnostiche facendo dell’avviatore PST un apparecchio estremamente semplice da utilizzare e riducendo il rischio di interpretazioni dei dati errate o scorrette. Sul display inoltre è possibile leggere in qualunque momento i valori relativi alla corrente erogata, alla tensione in uscita, al numero di avviamenti, al tempo totale di funzionamento e alla temperatura del motore. Sono segnalate anche le eventuali condizioni di guasto con messaggi di testo nella lingua selezionata. Tastiera a quattro pulsanti Gli avviatori PST utilizzano lo stesso concetto di base applicato ai moderni telefoni cellulari. Con i quattro pulsanti della tastiera, è possibile regolare con facilità il profilo di avviamento/arresto e le funzioni di protezione motore per qualunque tipo di applicazione. Una serie di impostazioni standard rende più semplice e rapida la configurazione degli avviatori in molte applicazioni comuni, tra cui pompe, trasportatori, ventilatori, mescolatori e compressori. Si possono impostare anche parametri avanzati di preallarme per identificare eventuali problemi prima che si manifestino. Una funzione di protezione mediante password impedisce di apportare modifiche non autorizzate alla programmazione. Avviamento di più motori È possibile memorizzare fino a tre diversi set di parametri per l’avviamento in sequenza ottimale di tre motori distinti. Questa funzione è utilizzabile anche per motori a due o tre velocità. Protezione avanzata del motore (integrata) Gli avviatori graduali PST sono provvisti di funzioni di protezione avanzata del motore e dell’avviatore, incluse funzioni programmabili per la protezione da sovraccarico, da correnti elevate, da minimo carico, da sbilanciamento di fase, da inversione di fase e da sovraccarico dei tiristori, oltre a funzioni di controllo di by-pass. Comunicazione fieldbus Gli avviatori graduali PST dispongono di un’interfaccia integrata sul frontale per il collegamento del dispositivo FieldBusPlug di ABB, utilizzato per la comunicazione tramite bus. Attraverso l’interfaccia è possibile controllare l’avviatore graduale, ottenere informazioni di stato e caricare o scaricare parametri. Tra l’avviatore graduale e il FieldBusPlug, si utilizza sempre la stessa interfaccia. Indipendentemente dalla taglia dell’avviatore o da successivi ampliamenti dell’installazione, è possibile collegare anche in seguito il dispositivo a qualunque protocollo di comunicazione già definito nel FieldBusPlug. In particolare, sono disponibili i sistemi AS-i, DeviceNet e Profibus DP. Per il collegamento dell’avviatore PST a un sistema fieldbus, sono necessari gli accessori descritti alle pagine da 7/23 a 7/25, oltre al software specifico di configurazione che può essere scaricato dalle pagine Avviatori graduali del sito www.abb.com/lowvoltage 7 Relè programmabili di segnalazione Tutti gli avviatori PST dispongono di tre relè programmabili di segnalazione Run (Marcia), Top of Ramp (Inizio rampa) o Event (Evento). L’impostazione di Evento può essere utilizzata per segnalazioni relative a protezioni, guasti e allarmi. Le funzioni di supervisione permettono di monitorare non soltanto il software e le funzionalità critiche dell’avviatore graduale, ma anche le eventuali perdite di fase e le deviazioni dal campo di frequenza. Contattore di by-pass (integrato) Sulle taglie di avviatori più grandi (PSTB 370 ... PSTB1050), è installato un contattore AF di ABB che assicura importanti vantaggi in termini di risparmio di costi, economie di spazio e riduzione degli sprechi di energia. Con un contattore di by-pass, si possono limitare le perdite di potenza in misura pari o superiore al 90% nel normale funzionamento. Le unità da PST30 a PST300 più piccole, che non dispongono di un contattore di by-pass integrato, dispongono di una serie aggiuntiva di tre morsetti sul lato linea. I morsetti sono contrassegnati come B1, B2 e B3 e si utilizzano nel collegamento di un contattore di by-pass esterno per abilitare le funzioni di protezione integrata anche quando l’avviatore graduale è by-passato. PSTB1050 con contattore di by-pass integrato 7/15 Cap_7.p65 15 3/9/04, 4:29 PM PST30 ... 300 e PSTB370 ... 1050 per avviamenti normali in linea, classe 10 Informazioni di dettaglio per l'ordinazione PST30 ... PST300 230 – 600 V 1SFC132017F0201 Potenza del motore 1SFC132013F0201 PST30 ... PST72 400 V 500 V 690 V Pe Pe Pe kW kW 15 18,5 22 25 30 37 45 55 75 90 110 132 160 18,5 22 25 30 37 45 55 75 90 110 132 160 200 Tensione di alimentazione 100 ... 250 V, 50/60 Hz kW Corrente nominale del motore, Ie A Tipo Codice d'ordine - 30 37 44 50 60 72 85 105 142 175 210 250 300 PST30-600-70 PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 002 003 004 005 006 007 008 009 010 011 012 013 014 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 4,8 4,8 4,8 4,8 5,0 5,0 11,2 13,0 13,0 21,5 21,5 23,0 23,0 400 – 690 V PST85 ... PST142 1SFC132015F0201 Potenza del motore PST175 ... PST300 400 V 500 V 690 V Pe Pe Pe kW kW 15 18,5 22 25 30 37 45 55 75 90 110 132 160 18,5 22 25 30 37 45 55 75 90 110 132 160 200 Tensione di alimentazione 100 ... 250 V, 50/60 Hz kW Corrente nominale del motore, Ie A Tipo Codice d'ordine 25 30 37 45 55 59 75 90 132 160 184 220 257 30 37 44 50 60 72 85 105 142 175 210 250 300 PST30-690-70 PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 7 Scelta della taglia corretta per avviamenti gravosi Consultare la tabella a pag. 7/12 7/16 Cap_7.p65 894 894 894 894 894 894 894 894 894 894 894 894 894 Peso kg 16 3/9/04, 4:29 PM 895 895 895 895 895 895 895 895 895 895 895 895 895 002 003 004 005 006 007 008 009 010 011 012 013 014 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 4,8 4,8 4,8 4,8 5,0 5,0 11,2 13,0 13,0 21,5 21,5 23,0 23,0 PST30 ... 300 e PSTB370 ... 1050 per avviamenti normali in linea, classe 10 Informazioni di dettaglio per l'ordinazione 230 – 600 V 1SFC132018F0201 Potenza del motore 400 V 500 V 690 V Pe Pe Pe kW kW 200 250 315 400 450 560 250 315 400 500 560 730 Tensione di alimentazione 100 ... 250 V, 50/60 Hz kW Corrente nominale del motore, Ie A Tipo Codice d'ordine - 370 470 570 720 840 1050 PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 894 894 894 894 894 894 015 016 017 018 019 020 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 31,0 31,0 52,0 55,0 60,0 60,0 400 – 690 V Potenza del motore 1SFC132014F0201 PSTB370 ... PSTB470 400 V 500 V 690 V Pe Pe Pe kW kW 200 250 315 400 450 560 250 315 400 500 560 730 Tensione di alimentazione 100 ... 250 V, 50/60 Hz kW Corrente nominale del motore, Ie A Tipo Codice d'ordine 355 450 560 710 800 965 370 470 570 720 840 1050 PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 895 895 895 895 895 895 015 016 017 018 019 020 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 31,0 31,0 52,0 55,0 60,0 60,0 PSTB570 ... PSTB1050 7 Scelta della taglia corretta per avviamenti gravosi Consultare la tabella a pag. 7/12 7/17 Cap_7.p65 17 3/9/04, 4:29 PM PST30 ... 300 e PSTB370 ... 1050 per avviamenti normali in triangolo, classe 10 Informazioni di dettaglio per l'ordinazione PST30 ... PST300 230 – 600 V 1SFC132017F0201 Potenza del motore 1SFC132013F0201 PST30 ... PST72 400 V 500 V 690 V Pe Pe Pe kW kW kW Tensione di alimentazione 100 Corrente nominale del motore, Ie A 25 30 - 52 30 37 - 64 37 45 - 76 45 55 - 85 55 75 - 105 59 80 - 124 75 90 - 147 90 110 - 181 132 160 - 245 160 200 - 300 184 250 - 360 220 295 - 430 257 355 - 515 250 V, 50/60 Hz Tipo Codice d'ordine PST30-600-70 PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 894 894 894 894 894 894 894 894 894 894 894 894 894 002 003 004 005 006 007 008 009 010 011 012 013 014 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 4,8 4,8 4,8 4,8 5,0 5,0 11,2 13,0 13,0 21,5 21,5 23,0 23,0 400 – 690 V PST85 ... PST142 1SFC132015F0201 Potenza del motore PST175 ... PST300 400 V 500 V 690 V Pe Pe Pe kW kW kW Tensione di alimentazione 100 Corrente nominale del motore, Ie A 25 30 45 52 30 37 55 64 37 45 59 76 45 55 75 90 55 75 90 105 59 80 110 124 75 90 132 147 90 110 160 181 132 160 220 245 160 200 257 300 184 250 315 360 220 295 400 430 257 355 500 515 PST30-690-70 PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 7/12 7/18 18 250 V, 50/60 Hz Codice d'ordine Scelta della taglia corretta per avviamenti gravosi Consultare la tabella a pag. ... Tipo 7 Cap_7.p65 ... 3/9/04, 4:29 PM 895 895 895 895 895 895 895 895 895 895 895 895 895 002 003 004 005 006 007 008 009 010 011 012 013 014 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 R7000 4,8 4,8 4,8 4,8 5,0 5,0 11,2 13,0 13,0 21,5 21,5 23,0 23,0 PST30 ... 300 e PSTB370 ... 1050 per avviamenti normali in triangolo, classe 10 Informazioni di dettaglio per l'ordinazione PSTB370 ... PSTB1050 con by-pass integrato 230 – 600 V 1SFC132018F0201 Potenza del motore PSTB370 ... PSTB470 Tensione di alimentazione 100 400 V 500 V 690 V Pe Pe Pe kW kW kW Corrente nominale del motore, Ie A 355 450 - 640 450 600 - 814 475 625 - 987 670 880 - 1247 780 1000 - 1455 875 1150 - 1810 ... 250 V, 50/60 Hz Tipo Codice d'ordine PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 894 894 894 894 894 894 015 016 017 018 019 020 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 31,0 31,0 52,0 55,0 60,0 60,0 400 – 690 V 1SFC132014F0201 Potenza del motore Tensione di alimentazione 100 400 V 500 V 690 V Pe Pe Pe kW kW kW Corrente nominale del motore, Ie A 355 450 600 640 450 600 800 814 475 625 860 987 670 880 1200 1247 780 1000 1400 1455 875 1150 1590 1810 ... 250 V, 50/60 Hz Tipo Codice d'ordine PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70 1SFA 1SFA 1SFA 1SFA 1SFA 1SFA 895 895 895 895 895 895 015 016 017 018 019 020 Peso kg R7000 R7000 R7000 R7000 R7000 R7000 31,0 31,0 52,0 55,0 60,0 60,0 PSTB570 ... PSTB1050 7 Scelta della taglia corretta per avviamenti gravosi Consultare la tabella a pag. 7/12 7/19 Cap_7.p65 19 3/9/04, 4:29 PM Accessori per PST30 ... 300 e PSTB370 ... 1050 Informazioni di dettaglio per l'ordinazione Connettori per cavi Al e Cu 1SFT98099-095C2 1SFT98099-011C1 Per i modelli PST85 ... 300, sono necessari 9 pezzi se si utilizzano anche i morsetti B1, B2, B3 per il contattore di by-pass esterno. Per avviatori graduali tipo Sezione dei cavi mm2 Coppia di serraggio max. Nm PST85 6-120 16 PST85 142 142 PST175 ... 300 2 x (50-120) 16 16-240 25 Tipo Codice d'ordine – LZ185-2C/120 – 1SDA 023 354 R0001 1SFN 074 709 R1000 1SDA 023 368 R0001 Confezione Pezzi Peso kg 1 pz 3 0,20 3 0,30 3 0,40 SB854C2 Connettori per cavi Al e Cu Per i modelli PST85...300, sono necessari 9 pezzi se si utilizzano anche i morsetti B1, B2, B3 per il contattore di by-pass esterno. LZ ... Per avviatori graduali tipo Sezione dei cavi mm2 Coppia di serraggio max. Nm PST85 ... 142 35-95 13,5 PST85 ... 142 25-150 31 PST175 ... 300 120-240 43 Tipo Codice d'ordine – – – 1SDA 023 356 R0001 1SDA 023 357 R0001 1SDA 023 370 R0001 Confezione Pezzi Peso kg 1 pz 3 0,10 3 0,10 3 0,10 1SFT98000-012C3 Estensioni morsetti 1SFT98000-011C3 LX ... LW ... Per avviatori graduali tipo Dimensioni del foro ø della barra mm2 mm Tipo Codice d'ordine Confezione Pezzi Peso kg 1 pz PST85 ... 142 10,5 20 x 5 LX300 1SFN 075 110 R1000 1 0,350 PST175 ... 300 8,5 17,5 x 5 LX185 1SFN 074 710 R1000 1 0,250 PSTB370 ... 470 10,5 25 x 5 LX400 1SFN 075 710 R1000 1 0,500 PSTB570 ... 1050 13 40 x 6 LX750 1SFN 076 110 R1000 1 0,850 Per avviatori graduali tipo Dimensioni del foro ø della barra mm2 mm Tipo Codice d'ordine Confezione Pezzi PST30 ... 72 6,5 15 x 3 LW110 1SFN 074 307 R1000 1 0,100 PST85 ... 142 10,5 17,5 x 5 LW185 1SFN 074 707 R1000 1 0,250 PST175 ... 300 10,5 20 x 5 LW300 1SFN 075 107 R1000 1 0,450 PSTB370 ... 470 10,5 25 x 5 LW460 1SFN 075 707 R1000 1 0,730 PSTB570 ... 1050 13 40 x 6 LW750 1SFN 076 107 R1000 1 1,230 Peso kg 1 pz Bulloni di fissaggio 7 Per avviatori graduali tipo PST85/147 ... 142/245 PST175/300 ... 300/515 Tipo Codice d'ordine LE185 LE300 1SFN 074 716 R1000 1SFN 075 116 R1000 Confezione Pezzi Peso kg 1 pz 2 0,20 2 0,30 Confezione Pezzi Peso kg 1 pz Calotte coprimorsetti LE185 Per avviatori graduali tipo Q.tà richiesta Tipo Codice d'ordine PST85 ... 142 1 pz + LT185-AC LT460-AC LT185-AL LT460-AL LT300-AC LT300-AL LT460-AC LT460-AL LT750-AC LT750-AL 1SFN 1SFN 1SFN 1SFN 1SFN 1SFN 1SFN 1SFN 1SFN 1SFN 1 pz PST85 ... 142 1 pz + PST175 ... 300 3 pz PST175 ... 300 3 pz PSTB370 ... 470 2 pz PSTB370 ... 470 2 pz PSTB570 ... 1050 2 pz PSTB570 ... 1050 2 pz LT ... -AC 1SFT98099-125 1SFT98099-019C3 1 pz LT ... -AL 7/20 Cap_7.p65 20 3/9/04, 4:29 PM 124 701 R1000 125 701 R1000 124 703 R1000 125 703 R1000 125 101 R1000 125 103 R1000 125 701 R1000 125 703 R1000 126 101 R1000 126 103 R1000 2 0,050 2 0,100 2 0,220 2 0,800 2 0,070 2 0,280 2 0,100 2 0,800 2 0,120 2 0,825 FieldBusPlug AS-i Cavo arancione Informazioni di dettaglio per l'ordinazione AS-i FieldBusPlug Performance Interfaccia Slave AS-i già predisposta, con varie lunghezze di cavi. ● Applicabile su tutti gli avviatori per motori FBP e sui dispositivi con max. 4 segnali in ingresso e 3 segnali in uscita ● Grado di protezione IP 65, LED di diagnostica Confezione Peso kg Codice d'ordine Pezzi 1 pz 1SAJ 220 000 R0003 1 0,09 1SAJ 220 000 R0005 1 0,10 ASP22-FBP.100 1SAJ 220 000 R0010 1 0,13 ASP22-FBP.500 1SAJ 220 000 R0050 1 0,36 Denominazione Lunghezza del cavo Tipo AS-i Performance 0,25 m ASP22-FBP.025 AS-i Performance 0,50 m ASP22-FBP.050 AS-i Performance 1,00 m AS-i Performance 5,00 m Accessori di collegamento bus AS-i Spinotto AS-i per giunzioni bus Cavo bus già predisposto, con connettore M12 e capocorda aperto. ● Applicazione su giunzioni bus quali accoppiatori AS-i o dispositivi con interfaccia AS-i integrata ASP22-FBP Denominazione Confezione Peso kg Codice d'ordine Pezzi 1 pz ASF11-FBP.030 1SAJ 922 002 R0003 1 0,04 ASM11-FBP.030 1SAJ 922 003 R0003 1 0,04 Confezione Peso kg Lunghezza del cavo Tipo 0,30 m 0,30 m Spinotto AS-i con connettore femmina Spinotto AS-i con connettore maschio ASF11-FBP Spinotto AS-i per estensione bus Cavo bus già predisposto, con connettori maschio e femmina M12. ASX11-FBP Denominazione Lunghezza del cavo Tipo Codice d'ordine Pezzi 1 pz Cavo AS-i di estensione 1,00 m ASX11-FBP.100 1SAJ 922 001 R0010 1 0,08 Cavo AS-i di estensione 3,00 m ASX11-FBP.300 1SAJ 922 001 R0030 1 0,20 Cavo AS-i di estensione 5,00 m ASX11-FBP.500 1SAJ 922 001 R0050 1 0,31 Cavo AS-i di estensione 100 m ASC11-FBP.999 1SAJ 922 004 R1000 1 5,60 Confezione Peso kg Codice d'ordine Pezzi 1 pz Spinotto AS-i e accessori per estensione bus Cavo bus e accessori di accoppiamento ASM11-FBP.0 ASF11-FBP.0 Denominazione Tipo Spinotto AS-i, conn. maschio ASM11-FBP.0 1SAJ 922 005 R0001 5 0,15 Spinotto AS-i, conn. femmina ASF11-FBP.0 1SAJ 922 006 R0001 5 0,15 AST11-FBP.0 1SAJ 922 007 R0001 1 0,15 Confezione Peso kg Cavo AS-i piatto per circuito in derivazione con zoccolo M12 Dispositivo AS-i di indirizzamento, alimentazione, accessori Tipo Codice d'ordine Pezzi 1 pz unità di alimentazione estraibile ASA21-FBP.0 1SAJ 922 010 R0001 1 0,56 Alimentatore PS 24V/5A regolabile Systron PS24/5 2 423 416 01 1 0,58 Segnali indirizzi per FieldBusPlug CAL11-FBP.0 1SAJ 929 005 R0001 400 0,15 Denominazione Dispositivo AS-i di indirizzamento, incl. AST11-FBP.0 7/21 Cap_7.p65 21 3/9/04, 4:29 PM 7 FieldBusPlug DeviceNet Cavo nero Informazioni di dettaglio per l'ordinazione DeviceNet FieldBusPlug Interfaccia fieldbus DeviceNet già predisposta, con varie lunghezze di cavi. ● Applicabile su tutti gli avviatori per motori FBP e altri dispositivi ● Grado di protezione IP 65, LED di diagnostica Codice d'ordine Confezione Pezzi Peso kg 1 pz DNP21-FBP.025 1SAJ 230 000 R0003 1 0,09 DNP21-FBP.050 1SAJ 230 000 R0005 1 0,10 1,00 m DNP21-FBP.100 1SAJ 230 000 R0010 1 0,13 5,00 m DNP21-FBP.500 1SAJ 230 000 R0050 1 0,36 Denominazione Lunghezza del cavo Tipo DeviceNet 0,25 m DeviceNet 0,50 m DeviceNet DeviceNet Accessori di collegamento bus DeviceNet Spinotto DeviceNet per giunzioni bus Cavo bus già predisposto, con connettore M12 e capocorda aperto. ● Applicazione su giunzioni bus quali accoppiatori DeviceNet o dispositivi con interfaccia DeviceNet integrata DNP21-11FBP Peso kg 1 pz Tipo Codice d'ordine Confezione Pezzi Spinotto DeviceNet con connettore femmina 0,50 m DNF11-FBP.050 1SAJ 923 002 R0005 1 0,04 Spinotto DeviceNet con connettore maschio 0,50 m DNM11-FBP.050 1SAJ 923 003 R0005 1 0,04 Peso kg 1 pz Denominazione DNF-11FBP.050 Lunghezza del cavo Spinotto DeviceNet per estensione bus Cavo bus già predisposto, con connettori maschio e femmina M12. DNM-11FBP.050 DNX11-FDP Denominazione Lunghezza del cavo Tipo Codice d'ordine Confezione Pezzi Cavo DeviceNet di estensione 1,00 m DNX11-FBP.100 1SAJ 923 001 R0010 1 0,08 Cavo DeviceNet di estensione 3,00 m DNX11-FBP.300 1SAJ 923 001 R0030 1 0,20 Cavo DeviceNet di estensione 5,00 m DNX11-FBP.500 1SAJ 923 001 R0050 1 0,31 Cavo DeviceNet di estensione 100 m DNC11-FBP.999 1SAJ 923 004 R0001 1 5,6 Peso kg 1 pz Spinotto DeviceNet e accessori per estensione bus Cavo bus e accessori di accoppiamento 7 DNC11-FBP.999 Denominazione Tipo Codice d'ordine Confezione Pezzi Spinotto DeviceNet con connettore maschio DNM11-FBP.0 1SAJ 923 005 R0001 5 0,15 Spinotto DeviceNet con connettore femmina DNF11-FBP.0 1SAJ 923 006 R0001 5 0,15 Peso kg 1 pz DNM11-FBP.0 Resistenza di terminazione, alimentazione, accessori DNF11-FBP.0 Denominazione Tipo Codice d'ordine Confezione Pezzi Resistenza DeviceNet di terminazione, 120 Ohm DNR11-FBP.120 1SAJ 923 007 R0001 1 0,02 Unità di alimentazione PS 24 V/5 A regolabile Systron PS24/5 2 423 416 01 1 0,58 Per collegare l’avviatore graduale PST a un sistema fieldbus DeviceNet è necessario un software specifico di configurazione del PLC (file EDS) che può essere scaricato dalla sezione Avviatori graduali del sito www.abb.com/lowvoltage selezionando il link Documentazione software. Per informazioni o assistenza, contattare ABB. 7/22 Cap_7.p65 22 3/9/04, 4:29 PM FieldBusPlug Profibus DP Cavo viola Informazioni di dettaglio per l'ordinazione Profibus DP FieldBusPlug Interfaccia fieldbus Profibus DP già predisposta, con varie lunghezze di cavi. ● Applicabile su tutti gli avviatori per motori FBP e altri dispositivi ● Grado di protezione IP 65, LED di diagnostica Codice d'ordine Confezione Pezzi Peso kg 1 pz 1SAJ 240 000 R0003 1 0,09 PDP21-FBP.050 1SAJ 240 000 R0005 1 0,10 1.00 m PDP21-FBP.100 1SAJ 240 000 R0010 1 0,13 5.00 m PDP21-FBP.500 1SAJ 240 000 R0050 1 0,36 Denominazione Lunghezza del cavo Tipo Profibus DP-FBP 0,25 m PDP21-FBP.025 Profibus DP-FBP 0,50 m Profibus DP-FBP Profibus DP-FBP Accessori di collegamento bus Profibus DP Spinotto Profibus DP per giunzioni bus Cavo bus già predisposto, con connettore M12 e capocorda aperto. ● Applicazione su giunzioni bus quali accoppiatori Profibus DB o dispositivi con interfaccia Profibus DB integrata PDP21-FBP PDF11-FBP.50 Peso kg 1 pz Tipo Codice d'ordine Confezione Pezzi Spinotto Profibus DP con connettore femmina 0,50 m PDF11-FBP.050 1SAJ 924 002 R0005 1 0,04 Spinotto Profibus DP con connettore maschio 0,50 m PDM11-FBP.050 1SAJ 924 003 R0005 1 0,04 Peso kg 1 pz Denominazione Lunghezza del cavo Spinotto Profibus DP per estensione bus Cavo bus già predisposto, con connettori maschio e femmina M12. PDM11-FBP.50 PDX11-FBP Denominazione Lunghezza del cavo Tipo Codice d'ordine Confezione Pezzi Cavo Profibus DP di estensione 1,00 m PDX11-FBP.100 1SAJ 924 001 R0010 1 0,08 Cavo Profibus DP di estensione 3,00 m PDX11-FBP.300 1SAJ 924 001 R0030 1 0,20 Cavo Profibus DP di estensione 5,00 m PDX11-FBP.500 1SAJ 924 001 R0050 1 0,31 Cavo Profibus DP di estensione 100 m PDX11-FBP.500 1SAJ 924 001 R1000 1 5,60 Peso kg 1 pz Accessori Profibus DP per estensione bus PDM11-FBP.0 Denominazione Tipo Codice d'ordine Confezione Pezzi Connettore Profibus DP maschio PDM11-FBP.0 1SAJ 924 005 R0001 5 0,03 Connettore Profibus DP femmina PDF11-FBP.0 1SAJ 924 006 R0001 5 0,03 Peso kg 1 pz 0,02 PDF11-FBP.0 Resistenza Profibus DP di terminazione, accessori Denominazione Tipo Codice d'ordine Confezione Pezzi Resistenza Profibus DP di terminazione120 Ohm PDR11-FBP.120 1SAJ 925 005 R0001 1 Per collegare l’avviatore graduale PST a un sistema fieldbus Profibus DP è necessario un software specifico di configurazione del PLC (file GSD) che può essere scaricato dalla sezione Avviatori graduali del sito www.abb.com/lowvoltage selezionando il link Documentazione software. Per informazioni o assistenza, contattare ABB. 7/23 Cap_7.p65 23 3/9/04, 4:30 PM 7 PSS03 ... PSS25 e PSS18/30 ... PSS300/515 Caratteristiche tecniche PSS03 … PSS12 PSS25 PSS18/30 … PSS300/515 630 220 – 230 400 – 415 480 – 500 600 630 220 – 230 400 – 415 480 – 500 600 690 208 – 690 Capacità di avviamento alla corrente max. nominale, Ie 5x 5x 4x Avviamenti/ora Capacità in sovraccarico classe di servizio Coefficiente di servizio % 6 1) 10 100 6 1) 10 100 30 2) 10 115 (PSS18/30 ... 250/430) 110 (PSS300/515 Temperatura ambiente Di servizio Di stoccaggio °C °C -20 ... +50 -40 ... +70 -20 ... +50 -40 ... +70 -25 ... +60 -40 ... +70 Altitudine Altitudine max. m 4000 Tensione nominale d’isolamento, Ui Tensione nominale di impiego, Ue I e per 5 sec 4) I e 4000 per 5 sec 4) I e 4000 per 10 sec 3) 4) Grado di protezione Circuito principale IP 20 IP 20 Circuito ausiliario e comando IP 20 IP 20 IP 20 (PSS18/30-500 ... 44/76-500) IP 10 (PSS50/85 500 ... 72/124-500) IP 10 (PSS18/30-690 ... 72/124-690) IP 00 (PSS85/147 ... 300/515) IP 20 Impostazioni Tempo di rampa all’avviamento s Tempo di rampa all’arresto s Tensione iniziale all’avviamento % Limitazione corrente x rapporto di trasformazione 0,5 – 6,5 ± 15% 0,5 – 8 ± 25% 0 – 85 ± 15% – 0,5 – 10 ±10% 0,5 – 20 ±10% 0,5 – 50 ± 5% – 1 – 30 0 – 30 30 – 70 1,5 ... 4 Sezionatore Per collegamento in triangolo No No Sì ON/OFF Relè di segnalazione Segnale di by-pass Segnalazione per guasto Tensione nominale di impiego, Ue Corrente termica nominale, Ith Corrente nominale di impiego Ie in AC-15 (Ue=250 V) 7 V V 6) No No – – 6) Sì Sì (NA o NC) 250 5 V A No No – – A – – 1,5 Verde Giallo Giallo – – Verde Giallo (lampeggiante) Giallo Rosso – Verde – Verde Rosso Rosso LED di segnalazione Pronto per l’avviamento/stand-by ON Rampa di salita/discesa Rampa di avviamento completata T.O.R. Guasto generico Guasto esterno 5) 1) Per applicazioni che richiedono più di 6 avviamenti/ora, contattare ABB. 2) Valido per il 50% del tempo di attività e per il 50% del tempo di inattività 3,5 x I e per 7 sec. Se fossero necessari altri dati, contattare ABB. 3) Per temperature da 40 °C a 50 °C, declassare la corrente nominale dello 0,8% per ogni °C. 4) Per lutilizzo ad altitudini da 1000 metri a 4000 metri, declassare la corrente nominale utilizzando la formula seguente: [ % di Ie = x - 1000 100 - ] 150 x = effettiva altitudine per lavviatore graduale. 5) Solo se è collegato il trasformatore di corrente (accessorio). 6) Lunità ha contatti di by-pass integrati (AC-53b). 7/24 Cap_7.p65 24 3/9/04, 4:30 PM PSS03 ... PSS25 e PSS18/30 ... PSS300/515 Caratteristiche tecniche Sezione dei cavi di collegamento PSS03 … PSS25 e PSS18/30 … PSS300/515 Tipo PSS Circuito principale Morsetto di collegamento Rigido/A treccia Rigido/A treccia 03 … 12 25 18/30-500 … 44/76-500 50/85-500 … 72/124-500 18/30-690 … 72/124-690 85/147-500 … 142/245-500 85/147-690 … 142/245-690 175/300 … 300/515-500 175/300 … 300/515-690 1 x mm2 2 x mm2 2,5 2,5 10 6 2,5 – 16 2,5 – 16 6 – 50 6 – 25 V. accessori p.7/10 V. accessori p.7/10 V. accessori p.7/10 V. accessori p.7/10 Nm 0,5 2 2,6 4,5 V. accessori p.7/10 V. accessori p.7/10 mm mm – – – – – – – – 17,5 x 5 8,5 20 x 5 10,2 Nm – – – – 9 18 1 x mm2 2 x mm2 2,5 2,5 2,5 – 2,5 – 2,5 – 2,5 – 2,5 – Nm 0,5 0,5 0,5 0,5 0,5 0,5 Coppia di serraggio (consigliata) Barra di collegamento Larghezza e spessore Diametro del foro Coppia di serraggio (consigliata) Circuito ausiliario e comando Morsetto di collegamento Rigido/A treccia Rigido/A treccia Coppia di serraggio (consigliata) Dati tecnici associati alle taglie PSS03 ... PSS25 e PSS18/30 ... PSS300/515 Per avviatori Taglia Protezione ABB da sovraccarico consigliata Campo di corrente Tipo A Perdita max. di potenza al valore max. /e W Taglia max. dei fusibili per il circuito principale1) Fusibili Bussman Circuito con fusibili Ferraz A Tipo Portafusibili A Tipo PSS03 PSS12 PSS25 TA 25 DU TA 25 DU TA 25 DU 2,2–3,1 10–14 18–25 – – – 16 40 50 170M1359 170M1363 170M1364 170H1007 170H1007 170H1007 PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515 TA 25 DU TA 25 DU TA 42 DU TA 75 DU TA 75 DU TA 75 DU TA 75 DU TA 110 DU TA 110 DU TA 200 DU TA 200 DU TA 450 DU TA 450 DU 6–18 10–30 22–37 29–44 29–50 29–60 45–72 65–85 65–105 100–142 100–175 130–250 130–300 65 100 120 142 160 190 226 291 351 462 590 815 965 50 80 125 160 160 200 250 315 400 450 500 700 900 170M1364 170M1366 170M1368 170M1369 170M1369 170M1370 170M1371 170M1372 170M3019 170M3020 170M3021 170M4017 170M5015 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H3004 170H3004 170H3004 170H3004 170H3004 1) Potenza richiesta dal circuito di alimentazione ausil. VA allo spunto 2 2 5 63 100 160 200 200 250 315 400 400 500 530 630 900 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 6,6 URB 000 D08 V 0063 URB 000 D08 V 0100 URB 000 D08 V 0160 URD 30 D08 A 0200 URD 30 D08 A 0200 URD 30 D08 A 0250 URD 30 D08 A 0315 URD 30 D08 A 0400 URD 30 D08 A 0400 URD 30 D08 A 0500 URD 30 D08 A 0550 URD 31 D08 A 0630 URD 32 D11 A 0900 9 9 9 9 10 10 10 36 36 36 65 65 65 7 Per il circuito di alimentazione 6 A ritardato. 7/25 Cap_7.p65 25 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Caratteristiche tecniche Tensione nominale d’isolamento U Tensione nominale di impiego Capacità di avviamento i U e Alla corrente max. nominale Ir PST30 … 300 PSTB370 ... 1050 690 V 690 V 208 ... 690 V 208 ... 690 V 3 x Ir per 15 sec. 3 x 1) 30 Classe di sovraccarico 10 10 115% 115% (PSTB370 ±0 -25 +50 °C 2) ±0 +70 °C -25 4000 m 3) IP 10 +50 °C 2) Sì Presenza tensione Verde Sì Sì Guasto - Rosso Sì Sì Protezione - Giallo Sì Sì +70 °C Sì Sì Sì Sì avviamento e marcia) Sì Sì Collegamento PTC Sì Sì Protezione da rotore bloccato Sì Sì Protezione da minimo carico Sì Sì Sbilanciamento di fase Sì Sì Corrente elevata (8 x Sì Sì Sì Sì Sì Sì Protezioni Relè elettronico di sovraccarico Classi di intervento regolabili - 4000 m 3) IP 00 (PST30 ... 72) IP 00 (PST85 Classe 10 A, 10, 20 e 30 Rampa duale (funzione di (tutti) sovraccarico separata per ... 300) Circuito di alimentazione IP 20 IP 20 Circuito principale Contattore di by-pass integrato Sì LED di segnalazione Grado di protezione e comando Sì o Start motor 2 o 3). ... Altitudine Circuito principale Sì Sì Reset, Enable, Jog, DOL- On Temperatura ambiente Altitudine max. Sì Ingressi di avviamento/arresto supplementari (ogni ingresso può PSTB840) Di stoccaggio Interno 24 V DC (10 mA chiuso) essere programmato come None, 100% (PSTB1050) Di funzionamento No Sì Sistema di raffreddamento Raffreddamento a ventola Ie) Sì Sì Tensione di alimentazione - 100 ... 250 V 100 ... 250 V Un solo campo di tensione 50/60 Hz 50/60 Hz Corrente elevata +10% ... 15% +10% ... 15% Basso livello di corrente (controllato da termostato) PSTB370 ... 1050 Due ingressi programmabili Ir per 15 sec 1) Numero di avviamenti/ora Capacità di sovraccarico Fattore di servizio 10 PST30 … 300 Circuito di comando/Ingressi hardware Protezione da inversione di fase Circuito di alimentazione Allarmi (preavviso) Interfaccia uomo-macchina HMI per le impostazioni (minimo carico) Sì Sì (HMI = Human Machine Interface) Intervento per sovraccarico Sì Sì Sovratemperatura tiristori (SCR) Sì Sì Sì Sì FieldBusPlug ABB Sì Sì AS-i (cavo a richiesta) Sì Sì DeviceNet (cavo a richiesta) Sì Sì Profibus DP Sì Sì Display a 20 segmenti Sì Sì Tastiera con due tasti di selezione e due tasti di navigazione Sì Sì Messaggi di testo in 10 lingue (inglese, tedesco, italiano, cinese, finlandese, Avviamento di più motori Possibilità di configurare e avviare tre diversi motori Comunicazioni fieldbus Collegamento per svedese, francese, spagnolo, olandese e portoghese) Sì Sì Relè di segnalazione 7 Numero di relè programmabili di segnalazione (ogni relè può (cavo a richiesta) essere programmato come 1) relè per segnalazione di Marcia, By-pass o Evento) 3 K4 Predefinito come relè di Marcia Sì Sì K5 Predefinito come relè di By-pass Sì Sì K6 Predefinito come relè di Evento Sì Sì Tensione nominale di impiego Ue 250 V 250 V Corrente termica nominale Ith 5 A 5 A 1,5 A 1,5 A Corrente nominale di impiego Ie in AC-15 (Ue = 250 V) Valido per il 50% del tempo di attività e per il 50% del tempo di inattività, con 3,5 x 3 2) Ie per 7 secondi. Se fossero necessari altri dati, contattare ABB. Per temperature da 40 °C a 50 °C, declassare la corrente nominale dello 0,8% per ogni °C. 3) Per l'utilizzo ad altitudini da 1000 metri a 4000 metri, declassare la corrente nominale utilizzando la formula seguente: x - 1000 [ % di Ie = 100 - ] 150 x = effettiva altitudine per l'avviatore graduale. Principali impostazioni possibili, testo visualizzato e valori predefiniti Descrizione Testo sul display (inglese) Valori sul display Valore predefinito Impostazione di corrente per sovraccarico, rotore bloccato ecc. Setting Ie 9,0 ...1380 A, suddivisa in 19 campi di corrente a sovrapposizione V. diagramma a p. Tempo della rampa di avviamento Start Ramp 1 ... 30 s, 1 ... 120 s (l'intervallo dipende dall'intervallo di avviamento) 10 s 0 ... 120 s (l'intervallo dipende dall'intervallo di arresto) Tempo della rampa di arresto Stop Ramp 0 ... 30 s, Tensione iniziale della rampa di avviamento Init Volt 30 ... 70% 30% Tensione finale della rampa di arresto End Volt 30 ... 70% 30% Tensione ridotta Step Down 30 ...100% 100% Livello del limite di corrente Current Lim 2,0 ... 5,0 x I e 4,0 x Ie Selezione avviamento con booster (kick start) Kick Start Yes, No No Livello di avviamento con booster (kick start), se selezionato Kick Level 50 ... 100% 50 % Tempo di avviamento con booster (kick start), se selezionato Kick Time 0,1 ... 1,5 s 7/28 0 s 0,2 continua alla pagina seguente 7/26 Cap_7.p65 26 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Caratteristiche tecniche segue dalla pagina precedente Principali impostazioni possibili, testo visualizzato e valori predefiniti Descrizione Testo sul display (inglese) Valori sul display Valore predefinito Intervallo selezionabile per la rampa di avviamento Start Range 1 ... 30 s, 1...120 s 1 ... 30 s Intervallo selezionabile per la rampa di arresto Stop Range 0 ... 30 s, 0 ... 120 s 0 ... 30 s Protezione da sovraccarico Overload No, Normal, Dual Normal Classe di sovraccarico OL Class 10A, 10, 20, 30 10 Classe di sovraccarico, Duale, Classe di avviamento OL Class S 10A, 10, 20, 30 10 Classe di sovraccarico, Duale, Classe di funzionamento OL Class R 10A, 10, 20, 30 10 Tipo di funzionamento per protezione da sovraccarico OL Op Stop-M, Stop-A, Ind Stop-M Protezione da rotore bloccato Locked Rotor Yes, No No Livello di intervento per protezione da rotore bloccato Lock R Lev 3,0 ... 8,0 x Ie 4,0 x Ie Tempo di intervento per protezione da rotore bloccato Lock R Time 0,2 ... 10 s 1,0 s Tipo di funzionamento per protezione da rotore bloccato Lock R Op Stop-M, Stop-A, Ind Stop-M Protezione di minimo carico Underload Sì, No No Livello di intervento per protezione di minimo carico Underl Lev 0,4 ... 0,8 x Ie 0,8 x Ie Tempo di intervento per protezione di minimo carico Underl Time 1...30 s 10 s Tipo di funzionamento per protezione di minimo carico Underl Op Stop-M, Stop-A, Ind Stop-M Protezione da sbilanciamento di fase Phase Imb Yes, No No Livello di intervento per protezione da sbilanciamento di fase Ph Imb Lev 10 ... 80% 80% Tipo di funzionamento per protezione da sbilanciamento di fase Ph Imb Op Stop-M, Stop-A, Ind Stop-M Protezione da corrente elevata High I Yes, No No Tipo di funzionamento per protezione da corrente elevata High I Op Stop-M, Stop-A, Ind Stop-M Protezione da inversione di fase Phase Rev Yes, No No Tipo di funzionamento per protezione da inversione di fase Ph Rev Op Stop-M, Stop-A, Ind Stop-M Protezione a termistori PTC PTC Yes, No No Tipo di funzionamento per protezione a termistori PTC Op Stop-M, Stop-A Stop-M È utilizzato un contattore di by-pass esterno Ext ByPass Yes, No No No Allarme per corrente elevata Warn I=High Yes, No Livello d'intervento di allarme per corrente elevata Wa I=H Lev 0,5 ... 5,0 x Ie 1,2 x Ie Allarme per basso livello di corrente Warn I=Low Yes, No No Livello d'intervento di allarme per basso livello di corrente Wa I=L Lev 0,4 ...1,0 x Ie 0,5 x Ie Allarme per sovraccarico Warn OL Yes, No No Livello d'intervento di allarme per sovraccarico Wa OL Lev 40 ... 99% 90% Allarme per sovraccarico tiristori Warn SCR OL Yes, No Sì Tipo di funzionamento per guasto da perdita di fase Ph Loss Op Stop-M, Stop-A Stop-M Tipo di funzionamento per guasto di by-pass BP Fault Op Stop-M, Stop-A, Ind Stop-M Tipo di funzionamento per guasto di fieldbus FB Fault Op Stop-M, Stop-A Stop-M Tipo di funzionamento per guasto in frequenza Freq F Op Stop-M, Stop-A Stop-M Tipo di funzionamento per guasto da sovratemperatura del dissipatore HS Temp Op Stop-M, Stop-A Stop-M Tipo di funzionamento per guasto da cortocircuito dei tiristori SCR SC Op Stop-M, Stop-A Stop-M Funzione di ingresso programmabile In_0 None, Reset, Enable, Jog, DOL, Start 2 Reset Funzione di ingresso programmabile In_1 None, Reset, Enable, Jog, DOL, Start 3 Reset Funzione di uscita relè programmabile K4 Relay K4 Run, TOR, Event Run Funzione di uscita relè programmabile K5 Relay K5 Run, TOR, Event TOR Funzione di uscita relè programmabile K6 Relay K6 Run, TOR, Event Event Controllo dell'avviatore graduale con fieldbus Fieldb Ctrl Yes, No No Numero di sequenze per avviamento sequenziale a 1 sequenza, tempo della rampa di avviamento a sequenza, tensione iniziale per la rampa di avviamento a sequenza, limite di corrente 1 No of Seq No, 2, 3 Start Ramp1 1...30 s, Init Volt1 30 ... 70% 30% 7 No 1...120 s (l'intervallo dipende dall'intervallo di avviamento) 10 s Curr Lim1 2,0 ... 5,0 x Ie 4,0 x Ie 1st Set Ie 9,0 ... 1380 A suddivisa in 19 campi di corrente a sovrapposizione V. diagramma a p. sequenza, tempo della rampa di avviamento Start Ramp2 1...30 s, 10 s a sequenza, tensione iniziale della rampa di avviamento Init Volt2 30 ... 70% 30% a sequenza, limite di corrente Curr Lim2 2,0 ... 5,0 x Ie 4,0 x Ie a sequenza, impostazione di corrente 2nd Set Ie 9,0 ... 1380 A suddivisa in 19 campi di corrente a sovrapposizione V. diagramma a p. a sequenza, tempo della rampa di avviamento Start Ramp3 1...30 s, 10 s a sequenza, tensione iniziale della rampa di avviamento Init Volt3 30 ... 70% 30% Curr Lim3 2,0 ... 5,0 x Ie 4,0 x Ie 3rd Set Ie 9,0 ... 1380 A suddivisa in 19 campi di corrente a sovrapposizione V. diagramma a p. Lingua del display Language US/UK, FI, SE, PT, NL, IT, FR, ES, DE, CN US/UK Tempo di spegnimento automatico del display LCD Auto Off 1 ... 255 min 15 min Password per il display Password No, 1 ... 255 1 Tipo di presentazione data Date Tipo ISO, CE, US ISO Anno Date Year 2001...2060 Individuale 1 a 1 sequenza, impostazione di corrente a 2 2 2 2 3 3 a 3 sequenza, limite di corrente a 3 sequenza, impostazione di corrente 1...120 s (l'intervallo dipende dall'intervallo di avviamento) 1...120 s (l'intervallo dipende dall'intervallo di avviamento) Mese Date Month 1 ...12 Individuale Giorno Date Day 1 ... 31 Individuale Ora Time Hour 0 ... 23 Individuale Minuti Time Min 0 ... 59 Individuale 7/28 7/28 7/28 7/27 Cap_7.p65 27 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Caratteristiche tecniche Curve di intervento per il sovraccarico elettronico integrato Tutte le unità dispongono di un relè elettronico di sovraccarico che può essere impostato su quattro diverse classi di intervento. Nel grafico sotto sono tracciate le curve per le singole classi di intervento a freddo. Tempo (s) 10 000 1 000 100 Classe Classe Classe Classe 10 30 20 10 10 A 1 0 1 2 3 4 5 6 Corrente (x Ie ) Curve di intervento per sovraccarico elettronico (a freddo) 7 FieldBusPlug di ABB Possibilità di controllo con l'uso dei diversi fieldbus AS-i DeviceNet Profibus DP Controllo semplice (avviamento/arresto ecc.) X X X Controllo completo X X Informazioni semplici di stato X X X Informazioni dettagliate di stato X X Possibilità di scrivere parametri X X Possibilità di leggere parametri X Per maggiori informazioni, consultare il manuale di installazione e messa in servizio disponibile nella sezione Avviatori graduali del sito www.abb.com/lowvoltage. 7/28 Cap_7.p65 28 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Caratteristiche tecniche Sezione dei cavi di collegamento Avviatore graduale tipo Circuito principale Morsetti disponibili (Per by-pass esterno) PST30 ... 72 PST85 ... 142 PST175 ... 300 PSTB370 ... 470 PSTB570 ... 1050 L1, L2, L3 Sì Sì Sì Sì Sì T1, T2, T3 Sì Sì Sì Sì Sì B1, B2, B3 Sì Sì Sì No No Morsetto di collegamento Rigido/A treccia 1 x mm2 10 ... 95 V. accessori p. Rigido/A treccia 1 x mm2 6 ... 35 V. accessori p. Coppia di serraggio (consigliata), Nm 6,0 V. accessori p. Barra di collegamento No 17.5 7/22 7/22 7/22 V. accessori p. V. accessori p. V. accessori p. 7/22 7/22 7/22 25 20 40 6 5 5 6 E1861D 22.5 E1860D E1859D E1858D 22.5 Larghezza e spessore mm Diametro del foro mm Nm 9 18 40 49 Coppia di serraggio (consigliata) ø 8.5 ø 6.5 ø 10.2 ø 6.5 ø 12.5 ø 10.5 Circuito ausiliario e comando Morsetto di collegamento Sì Sì Sì Sì Sì Rigido/A treccia 1 x mm 2 2,5 2,5 2,5 2,5 2,5 Rigido/A treccia 1 x mm2 1,5 1,5 1,5 1,5 1,5 0,5 0,5 0,5 0,5 0,5 Coppia di serraggio (consigliata) Nm Taglie di fusibile e perdite di potenza Per avviatori Protezione ABB da sovraccarico consigliata Campo di corrente Tipo A Perdita max. di potenza al valore Taglia max. dei fusibili per il circuito principale1) Circuito con fusibili Ferraz nominale Ie Fusibili Bussman W A Tipo Portafusibili A Tipo Potenza richiesta dal circuito di alimentazione ausiliario VA/VA spunto PST PST30 Integrato 100 80 170M1366 170H1007 100 6,6 URB 000 D08V 0100 5 PST37 Integrato 12 9 ... 35 46 120 125 170M1368 170H1007 160 6,6 URB 000 D08V 0160 5 PST44 Integrato 15 ... 58 140 160 170M1369 170H1007 200 6,6 URD 30 D08A 0200 5 PST50 Integrato 15 ... 58 160 160 170M1369 170H1007 200 6,6 URD 30 D08A 0200 5 PST60 Integrato 18 ... 69 190 200 170M1370 170H1007 250 6,6 URD 30 D08A 0250 5 PST72 Integrato 23 ... 86 230 250 170M1371 170H1007 315 6,6 URD 30 D08A 0315 5 PST85 Integrato 30 ... 115 270 315 170M1372 170H1007 400 6,6 URD 30 D08A 0400 10 PST105 Integrato 38 ... 144 325 400 170M3019 170H3004 400 6,6 URD 30 D08A 0400 10 PST142 Integrato 45 ... 173 435 450 170M3020 170H3004 500 6,6 URD 30 D08A 0500 10 PST175 Integrato 60 ... 230 540 500 170M3021 170H3004 550 6,6 URD 30 D08A 0550 15 PST210 Integrato 75 ... 288 645 630 170M5012 170H3004 630 6,6 URD 31 D08A 0630 15 PST250 Integrato 75 ... 288 765 700 170M5013 170H3004 630 6,6 URD 31 D08A 0630 15 PST300 Integrato 90 ... 345 920 900 170M5015 170H3004 900 6,6 URD 31 D11A 0900 15 7 PSTB 500V PSTB370 Integrato 120 ... 460 90 700 170M5013 170H3004 630 6,6 URD 31 D08A 0630 20/480 PSTB470 Integrato 150 ... 575 110 900 170M5015 170H3004 900 6,6 URD 31 D11A 0900 20/480 PSTB570 Integrato 180 ... 690 105 900 170M5015 170H3004 900 6,6 URD 31 D11A 0900 25/900 PSTB720 Integrato 225 ... 863 110 1250 170M5018 170H3004 ) 1250 6,6 URD 33 D11A 1250 25/860 PSTB840 Integrato 300 ... 1160 170 1500 170M5018 170H3004 1600 6,6 URD 33 D11A 1250 25/860 PSTB1050 Integrato 360 ... 1380 170 1800 170M6020 170H3004 2000 6,6 URD 233 PLAF 2000 25/860 PSTB 690V PSTB370 Integrato 120 ... 460 90 700 170M5013 170H3004 630 6,6 URD 31 D08A 0630 20/480 PSTB470 Integrato 150 ... 575 110 900 170M5015 170H3004 900 6,6 URD 31 D11A 0900 20/480 PSTB570 Integrato 180 ... 690 105 900 170M5015 170H3004 900 6,6 URD 31 D11A 0900 25/900 PSTB720 Integrato 225 ... 863 110 1250 170M6018 170H3004 1250 6,6 URD 33 D11A 1250 25/860 PSTB840 Integrato 300 ... 1150 170 1500 170M6018 170H3004 1600 6,6 URD 33 TTFA 1600 25/860 PSTB1050 Integrato 360 ... 1380 170 1600 170M6019 170H3004 1600 6,6 URD 33 TTFA 1600 25/860 1) Per circuito di alimentazione 6A ritardato. 7/29 Cap_7.p65 29 3/9/04, 4:30 PM PSS03 ... PSS300/515 Dimensioni di ingombro 1SFT 98899-009 1SFT 98899-005 PSS18/30-500 ... 44/76-500 1SFT 98899-008 1SFT 98899-006 Profondità del profilato DIN 101 mm 1SFT 98899-004 Profondità del profilato DIN 101 mm PSS85/147-500 ... 142/245-500 PSS85/147-690 ... 142/245-690 PSS 175/300-500 ... 300/515-500 PSS 175/300-690 ... 300/515-690 1SFT 98800-003 1SFT 98899-013 1SFT 98800-002 1SFT 98899-012 1SFT 98899-010 1,5 265 1SFT 98899-011 PSS50/85-500 ... 72/124-500 PSS18/30-690 ... 72/124-690 7 1SFT 98899-007 PSS25 PSS03, PSS12 7/30 Cap_7.p65 30 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Dimensioni di ingombro PST30 ... 72 PST175 ... 300 PST85 ...142 19,6 20,5 20,5 62,5 62,5 44,5 20,5 43,75 43,75 53,5 6,5 7,5 43,75 PSTB370 ... 470 43,75 PSTB570 ... 1050 7 365 460 3,5 11,5 11,5 7/31 Cap_7.p65 31 3/9/04, 4:30 PM PSS03 ... PSS300/515 Schemi di collegamento PSS03 ... 25 Avviamento K5 V1, V2 Avviamento 1SFT 98899-022 Avviamento By-pass integrato Tiristore PSS18/30 ... 300/515 Arresto Avviamento 7 F6 Monitor di temperatura K5 Relè per azionamento alla piena tensione Ue ( = 100%) K6 Relè per segnale di T1 Trasformatore di T2 Trasformatore di guasto Arresto controllo Avviamento corrente V1-V6 Tiristore Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola Ventola 1SFT 98800-001 ed.3 Ventola Ventola 7/32 Cap_7.p65 32 3/9/04, 4:30 PM PST30 ... 300 e PSTB370 ... 1050 Schemi di collegamento PST30 ... 300 Tensione interna di comando Monitor di temperatura Ventole Arresto Avviamento Tensione interna di comando Arresto Avviamento Tensione esterna di comando Avviamento 24 V DC Arresto Scheda per bassa tensione Arresto Scheda per alta tensione Avviamento Tastiera Nota Il morsetto 3 è un collegamento di terra funzionale, non di protezione; deve essere collegato alla base di montaggio. PSTB370 ... 1050 Contattore di by-pass interno Tensione interna di comando Monitor di temperatura Ventole Arresto 7 Avviamento Tensione interna di comando Contattore di by-pass interno Arresto Avviamento Tensione esterna di comando Avviamento 24 V DC Arresto Scheda per alta tensione Scheda per bassa tensione Arresto Avviamento Nota Il morsetto 3 Tastiera è un collegamento di terra funzionale, non di protezione; deve essere collegato alla base di montaggio. 7/33 Cap_7.p65 33 3/9/04, 4:30 PM PSS ... PST ... PSTB Istruzioni per il montaggio a parete Distanza minima dalla parete/dal frontale Dimensioni A B C E F H PSS18/30 ... 44/76 PSS50/85 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515 20 20 20 20 10 10 10 10 100 100 100 100 120 140 181 356 200 250 340 340 163 163 265 265 PSS_-690 per 690 V PSS18/30 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515 20 20 20 10 10 10 100 100 100 140 181 356 250 340 340 163 265 265 PST - tutti PST30 ... 72 PST85 ... 300 PST175 ... 300 20 20 20 10 10 10 100 100 100 160 186 360 260 390 420 196 270 270 PSTB - tutti PSTB370 ... 470 PSTB570 ... 1050 20 20 15 15 150 150 365 435 460 515 361 381 Avviatori graduali tipo PSS_-500 per 500 V 7 7/34 Cap_7.p65 34 3/9/04, 4:30 PM