MENU SUMMARY 1- ELECTROMECHANICAL APPARATUS 4- 700 Line Analog Proportional and Microprocessor three points Control 200 LINE On-Off / Floating Control 4 4 4 4 4 5 5 5 5 5 Room thermostats Humidostats Bulb and capillary thermostats Fan-coil thermostat Anti-frost thermostats Immersion thermostats Pressostats Differential pressostats Flow switches Level controllers FAN-COILS AND VAV UNITS SYSTEMS 22 22 22 22 Controllers Auxiliary modules Temperature sensors Compensator modules 23 RT 220 Line Fan-coil Valve and 3-Stage Fan Speed Controllers Controllers and sensors 25 25 25 25 26 27 DIGITROLL 7000 Microprocessor Control Control unit Controllers Sensors Reset module DG7000 supervision system Terminal units controller cross reference 5- DDC SYSTEMS FOR HVAC 9 9 9 200 LINE On-Off / Floating Control Room thermostats Day-night digital room thermostat Temperature controllers 29 DIGITROLL 2000 Controllers- I/O Module Display - Modem -Supervisors 6- FIELD DEVICES 10 500 LINE V d.c. Output Propotional Control Temperature controllers Transmitters Temperature transmitters Humidity transmitters Pressure and differential pressure transmitters Room air quality transmitter 11 12 12 400 LINE Time Propotional Control Climatic controllers Actuators for globe valves Actuators for shoe and butterfly valves 31 31 31 31 Actuators Direct-mounting damper actuators Crank-arm mounting damper actuators Globe valves actuators 14 14 DIGITROLL 4000 Microprocessor controller - optimizer for heating systems Sequence boiler digital programmer 32 32 34 36 Motorized Valves On-Off motorized valves 37 38 40 40 41 43 Globe Valves Bodies For zone and Fan-coil units 2-way single-seat 2-way balanced 2-way double-seat 3-way Options and accessories 44 44 45 48 Butterfly Valves Shoe Valves CONTROL VALVES SIZING MODELS IN ALPHABETICAL ORDER 49 SALES AND SERVICE ORGANISATION 300 LINE Balance Potentiometer Propotional Control 7 7 7 7 Bulb and capillary thermostats Pressostats Level controllers Remote potentiometer 2- SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 3- AIR-CONDITIONING SYSTEMS AND APPARATUS 500 Line V. d.c. Output Propotional Control 17 17 17 18 18 18 18 19 19 19 19 19 19 20 20 21 2 Room thermostats Temperature controllers Anti-frost module Temperature sensors Humidity controllers Enthalpy controller Universal controllers Differential pressure controllers Air quality controller On-Off action module Selector modules Power units Electronic-pneumatic transducer module Signal transducers Digital indicators - Remote set-point adjusters Supply SUMMARY MENU ELECTROMECHANICAL APPARATUS 200 Line On-Off / Floating Control GENERAL INFORMATION Controllers On-Off types are fitted with a snap-acting SPDT switch, floating types are fitted with an electric SPDT contact with dead zone. Controlled devices Controlled devices operated by On-Off controllers are relay, solenoid valves, motorized valves MVA2/4 - V.Z - S300, damper actuators SB and SMR. Controlled devices operated by On-Off and floating controllers are damper actuators SB - SH200 - MDL20/40 and globe valves actuators MVB20 - SH200 - MVL20/40. BASIC SYSTEM CONTROLLERS MOTORIZED VALVES AS 200 YZB ACTUATORS MVA2/4 VALVE BODIES V.Z S 300 UF200 SB - SM VDM/VSM C 300 C300 Y110 MDL20 - 40/AF VF MVB20 - 40 VMB VSB SH200 - MVL20-40 SS - VS - VB YTC3 B300 DS BD295 3V - VM Y100 FG600 3 SUMMARY ELECTROMECHANICAL APPARATUS 200 Line Room thermostats Series AS200 - Bimetal thermal element. MODEL AS202 AS204 AS203 SCALE °C DIFFERENTIAL K 5 to 30 5 to 30 10 to 30 1 1 1 OTHER CHARACTERISTICS SPDT 5 (2) A-240 V a.c. as above - with summer/winter change-over as above with 3 speed Humidostats Series UF200 - Sensitive synthetic fibre element - UF215 room type - UF216 duct type. MODEL UF215 UF216 SCALE % R.H. DIFFERENTIAL % R.H. 30 to 95 35 to 95 4 2 OTHER CHARACTERISTICS SPDT 5 (2) A-240 V a.c. SPDT 1 5 (8) A-250 V a.c. Bulb and capillary thermostats Series C300 - Vapor filled sensitive element - Differential 2.5 to 5 K - SPDT 15 (2.5) A-250 V a.c. Die-cast aluminium case IP 55. MODEL MAX SAFE TEMPERATURE °C SCALE °C C306 C307 C308 C309 C310 -10 20 55 95 135 to 40 to 70 to 120 to 140 to 200 C306S -10 to 50 85 135 155 230 50 40 OTHER CHARACTERISTICS copper bulb and capillary 2 m long copper spiral for ambient applications Accessories for C300 thermostats. copper well ¾” gas 180 mm long stainless steel well ¾" gas 180 mm long brass gland nut ¾” gas with packing G1 G4 R1 Fan-coil thermostat Series YZB - Liquid filled sensitive element - Copper bulb and capillary 1 m long. SPDT 15 (2.5) A-230 V a.c. MODEL YZB SCALE °C DIFFERENTIAL K 0 to 40 2 OTHER CHARACTERISTICS setting knob and lock nut Anti-frost thermostats Series Y110 - Vapor filled sensitive element - Copper bulb and capillary 1.8 m long. SPDT 15 (8) A-230 V a.c. Note - For a proper working, temperature to bulb must be lower than that one to controller. MODEL Y110 Y110RM 4 SCALE °C DIFFERENTIAL K -10 to 12 1 OTHER CHARACTERISTICS max safe temperature 200 °C as above with manual reset MENU SUMMARY MENU ELECTROMECHANICAL APPARATUS Immersion thermostats Series YTC3 - Liquid filled sensitive element - SPDT 10 (2.5) A-250 V a.c.- IP 40 SCALE °C MODEL 0 to 90 to YTC3 YTC3RM DIFFERENTIAL K 90 110 200 Line OTHER CHARACTERISTICS copper well gas ½" - 100 mm long as above with manual reset 3 - Pressostats Series B300 - Sensitive metal bellows element - SPDT 15 (2.5) A-250 V a.c. - Die-cast aluminium case IP 55. SCALE kPa MODEL B301 B302 B303 B304 B301X B302X B303X B304X 10 100 200 500 10 100 200 500 to to to to to to to to 200 600 1400 3000 200 600 1400 3000 DIFFERENTIAL kPa 7 15 60 80 7 15 60 80 to to to to to to to to 30 120 400 400 30 120 400 400 MAX SAFE PRESSURE kPa 600 900 2200 3800 600 900 2200 3800 OTHER CHARACTERISTICS copper alloy bellows AISI 316 stainless steel bellows Differential pressostats Series BD200 - Differential for signaling dirty air filter - Membrane sensitive element - SPDT 1 (0.5) A-230 V a.c. SCALE m bar MODEL BD295 0.5 to 5 DIFFERENTIAL m bar MAX SAFE PRESSURE m bar 0.2 50 OTHER CHARACTERISTICS connections Ø 6 mm with PVC pipe air connections Flow switches Series Y100 - Paddle type - SPDT 15 (8) A-230 V a.c. MODEL RANGE Y100 1 to 170 m3/h Y101 1 to 5 m/s OTHER CHARACTERISTICS for liquids - 1" screwed connections for pipes Ø 1" to 8" for air - complete with mounting flange - paddle 175 x 80 Level controllers Series FG600 - AISI 304 stainless steel float - Flanged connections - SPDT 10 (1) A-24 V a.c. - Industrial water-proof case. MODEL FG601 FG603 FG604 MAX WORKING PRESSURE kPa DIFFERENTIAL mm MAX WORKING TEMPERATURE °C 1600 15 to 60 200 3000 25 to 60 230 OTHER CHARACTERISTICS cast-iron body - connections 20 mm cast-steel body - connections 20 mm as above with level sight glass Auxiliary mercury bulb switch for FG600. A1 A2 A3 A4 SPST 5 (0.2) A-24 V a.c. - closed at minimum level as above, closed at maximum level as above, open at minimum level as above, open at maximum level 5 SUMMARY MENU ELECTROMECHANICAL APPARATUS 300 Line Balance Potentiometer Proportional Control GENERAL INFORMATION Controllers They are linear potentiometer device type, with output signal 0 to 165 Ohm. For each variation of controlled variable in the range of proportional band, the output signal changes proportionally and controlled device assumes the relevant position by the balance potentiometer Controlled devices The suitable controlled devices are bidirectional actuators fitted with electronic card and 300 Ohm balance potentiometer MDL30 for damper, MVB36 - MVL36 for globe valves. BASIC SYSTEM CONTROLLERS ACTUATORS VALVE BODIES MDL30 C350 MVB30 VMB - VSB MVL36 SS - VS - VB B350 FG650 CM350 DS 3V - VM 6 SUMMARY MENU ELECTROMECHANICAL APPARATUS 300 Line Bulb and capillary thermostats Series C350 - Vapor filled sensitive element - 165 Ohm potentiometer - Die-cast aluminium case IP 55. MODEL PROPORTIONAL BAND K SCALE °C C356 C357 C358 C359 C360 -10 20 55 95 135 to 40 to 70 to 120 to 140 to 200 C356S -10 to 40 MAX SAFE TEMPERATURE °C OTHER CHARACTERISTICS 50 3 to 10 3 to 10 85 135 155 230 50 copper bulb and capillary 2 m long copper spiral for ambient applications Accessories for C300. G1 G2 G3 copper well ¾” gas - 180 mm long stainless steel well ¾” gas - 180 mm long brass gland nut ¾” gas with packing Pressostats Series B350 - Sensitive metal bellows element - 165 Ohm potentiometer - Die-cast aluminium case IP 55. MODEL B351 B352 B353 B354 B351X B352X B353X B354X SCALE kPa 10 to 200 PROPORTIONAL BAND kPa MAX SAFE PRESSURE kPa 500 to 3000 25 35 150 120 to to to to 100 350 900 900 600 900 2200 3800 10 100 200 500 25 35 150 120 to to to to 100 350 900 900 600 900 2200 3800 100 to 600 200 to 1400 to 200 to 600 to 1400 to 3000 OTHER CHARACTERISTICS copper alloy bellows AISI 316 stainless steel bellows Level controllers Series FG650-AISI 304 stainless steel float - Flanged connections - 165 Ohm potentiometer - industrial water­ proof case. SCALE kPa PROPORTIONAL BAND mm MAX SAFE PRESSURE kPa FG651 1600 60 200 cast-iron body-connections 20 mm FG653 FG654 3000 60 230 cast-steel body-connections 20 mm as above with level sight glass MODEL OTHER CHARACTERISTICS Auxiliary mercury bulb switch for FG650. A1 A2 A3 A4 SPST 5 (0.2) A-24 V a.c. - closed at minimum level as above, closed at maximum level as above, open at minimum level as above, open at maximum level Remote potentiometer Series CM350 - Scale 0 to 10 - Potentiometer for remote control of 300 Line actuators: MDL30, page 33; MVB36, page 34; MVL36, page 35. MODEL CM350 OTHER CHARACTERISTICS 165 Ohm potentiometer - flush mounting 7 SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 200 Line On-Off / Floating Control (General Information see page 3) BASIC SYSTEM SENSORS CONTROLLERS MOTORIZED VALVES ACTUATORS VALVE BODIES AX200 MVA V.Z SB - SM 00 VF MDL20 - 40 SH200 VMB - VSB S 300 DIGISTAT VDM/VSM MDL20 - 40/AF SS - VS - VB SB - CX200 MVB20 - 40 DS TX283 SP - TP SH200 - MVL20-40 500 Line 3V - VM V d.c. Output Proportional Control (General Information see page 15) BASIC SYSTEM SENSORS CONTROLLERS ACTUATORS VALVE BODIES VF CX500 SM - SMR500 SH500 - MDL50 SB VMB - VSB MDL50/AF SS - VS -VB TX581 SP - TP MV50 DS SH500 - MVL50 8 3V - VM SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 200 Line Room thermostats Series AX200 - Thermistor sensitive element - Supply 230 V a.c. RANGE °C DIFFERENTIAL K AX212A AX214 6 to 30 0.5 AX235 6 to 30 dead zone 0.5 to 6 MODEL ELECTRICAL DEVICE On-Off switch and 3-speed fan selector as above with summer/winter change over 2 stages SPDT 4 (0.5) A-230 V a.c. Day/night- weeks room thermostats Series DIGISTAT - Thermistor sensitive element. SCALE °C DIFFERENTIAL K DIGISTAT 3 5 to 30 0.6 1 SPDT 2(1) A-240 V a.c. - supply by built-in battery 1,5 (2 wire connections) DIGISTAT 3SF 5 to 30 0.6 Transmitter DIGISTAT RF3 (no electric connections) supply by built-in battery 4x1.5 V. Receiver DIGISTAT SCR: 1 SPDT 2 (1) A 240 V a.c. Supply 240 V a.c. MODEL OTHER CHARACTERISTICS Temperature controllers Series CX200 - Sensitive element: see SB - sensors, page 18 - Relay SPDT 2 (0.5) A-230 V a.c. MODEL CX228 SCALE °C DIFFERENTIAL K -10 to 120 1 to 10 OTHER CHARACTERISTICS wall or flush mounting Series TX200 - Drive and alarm relay circuits 2 (0.5) A-24 V a.c. - Supply 24 V a.c. - Sensitive element: see SP - TP sensors: pag. 10 - Flush mounting. DRIVE CIRCUIT MODEL TX283 ALARM CIRCUIT SCALE °C DIFFERENTIAL K SCALE °C DIFFERENTIAL K -30 to 400 2 to 20 ± 30 respect to set-point 2 OTHER CHARACTERISTICS 3-point digital type 9 SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 500 Line Temperature controllers Series CX500 - Proportional - Integral - Derivative (PID), changeable into Proportional on field - Direct/reverse action - Supply directly from actuator - Sensitive element: see SB sensors, page 18. MODEL CX528 SCALE °C PROPORT. BAND K INTEGRATION TIME Tn (s) DERIVATIVE TIME TD -10 to 120 °C 2 to 40 16 to 600 ¼ Tn MOUNTING wall or flush Series TX500 - Proportional - Integral - Derivative (PID), changeable into Proportional on field - Direct/reverse action - Supply 24 V a.c. - Flush mounting - Sensitive element: see SP - TP sensors. SCALE °C PROPORT. BAND K INTEGRATION TIME Tn (s) DERIVATIVE TIME Tv TX581 TX586 -30 to 400 °C 0 to 399 °C 2 to 40 20 to 600 1/8 Tn 1/4 Tn T4-20 options for TX500: output signal 4 to 20 mA MODEL OTHER CHARACTERISTICS digital set and temperature indication Temperature sensors for TX500 - Sensitive element: Platinum 100 Ohm at 0 °C MODEL 10 OTHER CHARACTERISTICS SPC immersion - AISI 304 well, 1/2" gas connection - conduit opening ∅ 10 mm = 113 mm long max fluid temperature: 150 °C TPC immersion - 1/2"gas AISI 304 well-conduit opening ∅ l0 mm 200 mm long max fluid temperature: 500 °C TPC-2 as above but with double sensitive element 421 option for SPC: AISI 304 stainless steel well and connection SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 400 Line Time Proportional Control GENERAL INFORMATION Controllers They are electronic type with integrated circuit with output signal by two relays. Signals are activated as proportional impulses, the time of which is proportional to the offset of the controlled variable temperature in respect to the set value. Controllers control supply hot water temperature depending on outdoor temperature value and on pre-set slope. Controlled devices Suitable controlled devices are mixing valves motorized by MVB28 and ST402 actuators. BASIC SYSTEM SENSORS CONTROLLERS ACTUATORS VALVE BODIES MVB28 VMB - VSB ST405//AM M3 - M4 ST402 - MVL20 3V - VM S-E S-C KX4356 S-F Climatic controllers Series KX400 - Outdoor weather compensated control for heating system - Slope 0.5 to 3.5 - Supply 230 V a.c. Sensitive element: KX435 see SN - sensors, KX436 see SB- sensors page 18 MODEL OTHER CHARACTERISTICS KX435G daily time switch with spring reserve -7 programs selector knob pump control circuit - SN sensors KX435S as above - with weekly time switch with spring reserve KX436G daily time switch with spring reserve -7 programs selector knob pump control circuit - SB sensors KX436S as above - with weekly time switch with spring reserve Accessories for KX400 and sensors for KX435 F1 SNC SNF SNE flush mounting bracket immersion supply water with well 1/2" gas - 117 mm length - 100 Ohm at 0 °C strap-on supply water - 100 Ohm at 0 °C outdoor - 300 Ohm at 0 °C 11 SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES 400 Line Actuators for globe valves Series MVB20 - see page 34. For valve body VMB - VMB-F, see page 41. Series ST400 - Bidirectional actuator with hand-drive and position indicator - Angular travel: 160° - Supply 230 V a.c. For valve bodies VMB16 see page 41 and, with accessories AG21 (pag. 42), VMB, VMB-F see page 41. MODEL ST402 ST2AV TIMING S TORQUE Nm POWER CONSUMPTION VA 360 15 5 OTHER CHARACTERISTICS for globe valves assembling ST402 on valve body ATTENTION: Actuators are usually supplied NOT mounted on valve bodies. In case actuators and valve bodies are required assembled, the specific part number [ST2AV] will have to be listed on the order together with the models of actuator and valve body. Actuators for shoe and butterfly valves Series ST400 - Bidirectional type with hand drive - Angular travel: 90°. For valve bodies M3 - M4 and VFG10 see page 44. SUPPLY V a.c. POWER CONSUMPTION VA 10 24 5 10 230 5 TIMING s TORQUE Nm ST404 360 ST405 360 MODEL ST5AV OTHER CHARACTERISTICS for butterfly and shoe valves M3 ­ M4 all size assembling ST404/405 on valve body ATTENTION: Actuators are usually supplied NOT mounted on valve bodies. In case actuators and valve bodies are required assembled, the specific part number [ST5AV] will have to be listed on the order together with the models of actuator and valve body. 12 SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES DIGITROLL 4000 DIGITROLL is trade-mark of CONTROLLI digital systems. RK4000 Microprocessor controller-optimizer RK4000, fitted with Liquid Crystal Display (LCD) and pressure-sensitive key pad, provides hot water supply temperature control with outside compensation, domestic hot water control, optimization depending on outside or room temperature. Supply temperature limits, pumps start-stop, heating time schedule, universal limit. P+l control, output by relays. Interface direct or by modem with Building Management Systems. Controllers use temperature sensors SB - RK-A, valves with MVB40, SH200 and MVL40 actuators. RP4000 Microprocessor sequence boiler programmer RP 4000, fitted with Liquid Crystal Display (LCD) and pressure sensitive key pad, provides to control supply temperature (fixed or out-door compensated) and operates motorized valves. Controllers use temperature sensors SB -, transmitters TT-31, butterfly valves with bidirectional actuator ST404/405 or MDL44/AF22 BASIC SYSTEM SENSORS TRANSMITTERS CONTROLLERS RK4000 ACTUATOR MVB40 VALVE BODIES VMB VSB SBE SS - VS SH200 - MVL40 SBC - SBF DS 3V - VM RK-A RP4000 ST404 VF 13 SUMMARY MENU SYSTEMS AND APPARATUS FOR HEATING PLANTS AND INDUSTRIAL PROCESSES DIGITROLL 4000 Microprocessor controller-optimizer Series RK4000 - Microprocessor type - Supply 24 V a.c. - Panel or flush mounting - Sensitive elements: see sensors here below. It operates motorized valves 200 Line MVB40 - SH 222 - MVL40, see page 34 and 35. MODEL OTHER CHARACTERISTICS RK4113 supply water temperature (max 120 °C) control depending on outside conditions ­ optimization according to outside temperature (ON SPST contact) - low and high supply temperature limits pump start/stop - domestic hot water pump priority RM77 remote set-point adjuster Sequence boiler programmer Series RP4000 - Microprocessor type - Supply 24 V a.c. - Panel or flush mounting - Sensitive element: see sensors and transmitters here below. It operates butterfly valves VFG10 motorized with ST404, see page 12 or MDL40/AF22, see page 33 and 43. MODEL RP4102 OTHER CHARACTERISTICS Sequence programmer of 2 boilers with same or different capacity. Control AUTO-PERMANENT in NORMAL - REDUCED - STOP POSITION- Time programs ­ Time inversion of sequence - Start-stop delay time - Boilers LED signals - Open-closed valves - Inlet for optimizer - Min. and max. temperature limits - Summer compensation (add SBE sensors). Sensors for RK4000 and RP4002 MODEL 14 OTHER CHARACTERISTICS RK-A11 room temperature sensor for self-adjusting optimization (dimensions 85 x 115 x 32) RK-A41 SBC as above with set-point adjustment immersion temperature sensor, connection 1/8" gas in nickel plated brass - AISI 304 stainless steel well - lenght 113 mm - conduit opening ∅ 10 mm max ambient temperature 50 °C - max fluid temperature 140 °C - max fluid pressure 40 bar - protection IP 43 (DIN 40050) SBE outside temperature sensor SBF strap-on supply water - 100 Ohm at 0 °C 421 AISI 304 stainless steel SBC connection SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS 500 Line V d.c. Output Proportional Control GENERAL INFORMATION AX - CX - TX - W500 controllers, hybrid and integrated electronic circuit type. For each variation of controlled variable into proportional band range, corresponds a proportional variation of output signal by which actuator/motorized valve assumes the relevant position by the feedback potentiometer. Input signals: Temperature, humidity, differential and absolute pressure sensors and transmitters. WM master for winter-summer compensation RM or BMS for remote set-point adjustment Output signals: 0 to 15 V d.c. to drive in unison or in sequence controlled devices. Direct/reverse action. -5 to +15 V d.c. to remote analog and digital indicators recorders, auxiliary controllers. Controlled devices. Damper actuators SM500 - SH500 - MDL50, motorized valves with SH500 - MVL50 - MVB50 - MTV5. Auxiliaries A wide range of analog and digital indicators, transducers, modules. BASIC SYSTEM SENSORS CONTROLLERS ACTUATORS VALVE BODIES AX500 SM -SMRa500 SH500 - MDL50 RX500 CM500 MVB50 VMB VSB SB … SH500 - MVL50 SS - VS - VB DS CP8500 3V - VM 15 SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS BASIC SYSTEM SENSORS TRANSMITTERS CONTROLLERS MODULES WT - WF - WM ACTUATORS VALVE BODIES SM-SMR500 IZA WM557 SH500 - MDL50 WD500 WA WV MVB50 VMB VSB GS540 SB … WH - WE SH500 - MVL50 SS - VS - VB WI . IW WP560 CM500 DS CP 8500 TT WQ500 PNEUMATIC CONTROLLED DEVICES 3V - VM TQ - A WS MVT5 TU TP-C TW-D TP-D 16 V-T SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS 500 Line Room thermostats Series AX525 NTC sensitive element, supply 24 V a.c. MODEL AX525 SCALE °C 5 to PROPORT. BAND K SET-POINT ADJUSTMENT 1,5 external 35 OTHER CHARACTERISTICS 2 output 0…10 V d.c. dimensions 117 x 71 x 31 mm. Temperature controllers Series RX500 - Direct/reverse action - Sensitive element: see SB sensors, page 18. MODEL RX513 RX515 RX517 SCALE °C 0 to -10 to 30 to 45 80 120 PROPORT. BAND K 3 to 24 SUPPLY direct from actuator OTHER CHARACTERISTICS panel mounting Temperature controllers Series WT510 Proportional+Integrative+Derivative - Direct/reverse action WT530 -as above with auxiliary relay 1 SPDT 2 (0.5) A - 24 V ac WT540 -as WT510 with min or max proportional limit action WM550 -as WT510 with compensation action WT220 -on-off output by relay Supply 24 V a.c. - Panel or flush mounting (see terminal board MW page 19) Sensitive element: see SB sensor page 18, only for WM557 see TU transmitters page 31. MODEL WT513 WT515 WT533 WT535 SCALE °C PROPORT. BAND % SPAN 0 to 50 20 to 120 2 to 40 0 to 50 20 to 120 2 to 40 INTEGRAL ACTION % 0 to 100 0 to 100 TIME sec. OTHER CHARACTERISTICS 0 to 600 0 to 600 relay working point V d.c. differential V d.c. 0 to 11 0.5 to 3 limit scale proportional band % span °C WT543 WT545 0 to 50 20 to 120 2 to 40 0 to 100 0 to 600 0 to 20 to 50 120 2 to 40 compensation WM551 WM552 WM553 WM554 WM555 WM557 0 to 50 2 to 40 0 to 100 0 to 600 winter + limit* winter winter + limit** summer summer + limit* reverse slope 0 0 0 0 0 0 to to to to to to 3,5 3,5 3,5 1 1 3,5 differential dead zone relay K K 0 to 50 1 1 to 10 2 SPDT WT223 20 to 120 2 1 to 20 2 (0.5) A-24 V a.c. WT225 For recalibration of WM - WT through model WR502, see page 25, add suffix PS1. * limit range: 0 to 60 °C **limit range: 0 to 120 °C. Anti-frost module Series WF590 -Module with potentiometer for minimum position of out door air damper and manual reset Output by relay SPDT 2 (0.5) A- 24 V a.c. - Sensitive element: see SB sensors page 18. MODEL WF594 SCALE 0 to 20 DIFFERENTIAL K SUPPLY V a.c. 1.5 24 OTHER CHARACTERISTICS panel or flush mounting see accessories MW page 19 17 SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS 500 Line Temperature sensors Balco 1000 Ohm 21.1 °C sensitive element - for RX - CX228-528 - W500 controllers. MODEL OTHER CHARACTERISTICS SBA SBA20 SBA55 room (dimensions 85 x 55 x 32 mm) room dual sensitive element (dimensions 115 x 85 x 32 mm) room with set-point adjustable from 5 to 35 °C (dimensions 115 x 85 x 32 mm) SBC immersion - AISI 304 stainless steel well - 1/8" gas nickelplated brass connection - length 113 mm conduit opening ∅ 10 mm - max fluid temperature 140 °C SBD duct-with mounting flange -rod ∅ 7.5 mm -length 300 mm-conduit opening ∅ 10 mm - max fluid temperature 95 °C SBV duct - with high velocity sensitive element - length 210 mm - max temperature 60 °C. Not suitable for applications with possible condensate. SBE outdoor - conduit opening ∅ 10 mm 421 AISI 304 stainless steel for SBC connection Humidity controllers Series WH570 - P + I + D - Direct/reverse action WH574 -as above with auxiliary relay 1 SPDT 2 (0.5) A-24 V a.c. WH270 -On-Off - Output by 2 relays - Dead zone 2 to 15% R.H. Supply 24 V a.c. - Sensitive element: see TU transmitters, see page 31. MODEL WH572 WH574 WH272 % R.H. PROPORT. BAND % SPAN 10 to 90 10 to 90 2 to 40 2 to 40 SCALE AUXILIARY RELAY WORKING POINT V d.c. DIFFERENT. V d.c. 0 to 11 0.5 to 3 differential % R.H. relay 1 2 SPDT 2 (0.5) A-24 V a.c. 10 to 90 OTHER CHARACTERISTICS panel or flush mounting (see MW terminal boards page 19) Enthalpy controller Series WE590 -Comparison and control enthalpy module - Proportional control with minimum damper opening set - Sensitive element: see TU transmitters, see page 31. MODEL MIN POSITION OUTDOOR DAMPER % SUPPLY V a.c. 0 to 100 24 WE593 OTHER CHARACTERISTICS panel or flush mounting (see MW page 19) Universal controller Series WV -P+ I + D -Direct/reverse action - Integral action as WT - Supply 24 \/ a.c. -Panel or flush mounting (see terminal board MW page 19) - Sensitive element: transmitters, see page 31. MODEL SCALE % WV511 WV539 18 0 to 100 PROPORT. BAND % SPAN 2 to 40 OUTPUT INPUT 0 to 10 V d.c. V d.c. RELAY 0 to 10 0 to 10 not yes SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS 500 Line Differential pressure controllers Series WP560 - Proportional + Integral + Derivative - Direct/reverse action - Sensitive element: see TP-D transmitters page 31. SCALE Pa MODEL 0 to 100 0 to 1000 0 to 2500 WP562 PROPORT. BAND % SPAN SUPPLY V a.c. 2 to 40 24 OTHER CHARACTERISTICS panel or flush mounting (see MW terminal boards) Air quality controller Series WQ530-Proportional+ Integral+ Derivative-Direct/reverse action Sensitive element: seeTQ-A transmitters, page 31. MODEL WQ533 SCALE % PROPORT. BAND % SPAN SUPPLY V a.c. 0 to 100 2 to 40 24 OTHER CHARACTERISTICS panel or flush mounting (see MW terminal boards) On/Off action module Series WD540 - Two/four stages - Supply 24 V a.c. - panel or flush mounting - See MWD terminal boards. MODEL WD542 WD544 SCALE DIFFERENTIAL V d.c V d.c 3 to 12 3 to 12 0.5 to 3 0.5 to 3 RELAY 2 SPDT 2 (0.5) 1-24 V a.c. 4 SPDT 2 (0.5) 1-24 V a.c. Selector modules Series MM501 - Highest signal selector Series WS506 - Highest or lowest signal selector - Supply 24 V a.c. MODEL MM501 WS506 INPUT SIGNAL V d.c. SIGNALS No. 0 to 15 0 to 15 2 max 6 OTHER CHARACTERISTICS panel mounting panel or flush mounting (see MW terminal boards) Terminal boards necessary for mounting all W..... controllers and modules MW1 MW2 for panel mounting (except WD) for flush or rack 19" mounting (except WD) MWD1 MWD2 for panel mounting of WD540 for flush mounting of WD540 Power units Series GS -Input signal 5 to 10 / 0 to 10 V d.c -TRIAC (SRC) device -Supply 24 V a.c. - For three-phase systems use no. 3 power units. MODEL CURRENT A MAX VOLTAGE V a.c. 25 40 60 440 440 440 GS541 GS542 GS543 OTHER CHARACTERISTICS panel mounting on track size 35 mm DIN 46277/3 Electronic-pneumatic transducer modules Series CP8500 - Output signal 3 to 13 psi - Air supply 30 psi max - Consumption 500 Nl/h. MODEL INPUT SIGNAL V d.c. CP8511 CP8551 CP8552 1 to 5, 6 to 9, 0 to 10 1 to 5, 6 to 9, 0 to 10 ACTION SUPPLY direct/reverse direct direct 24 V a.c. from actuator 24 V a.c. OTHER CHARACTERISTICS mA 4 to 20 4 to 20 4 to 20 panel mounting 19 SUMMARY MENU AIR CONDITIONING SYSTEMS AND APPARATUS 500 Line Signal transducers Series IZ - Supply 24 V a.c. - Mounting on track size 35 mm DIN 46277/3 MODEL IZA IZB lZV OTHER CHARACTERISTICS input 3 to 12 V d.c. - output 12 to 3 V d.c. input from SB sensors - output 0 to 10 V d.c. input 4 to 7; 6 to 9; 8 to 11; 0 to 10 V d.c. - output 4 to 20 mA Remote set-point adjusters Series CM500 - Remote manual potentiometer to drive 500 Line actuators - Flush mounting. Series RM50 - Potentiometer for remote set-point - Flush mounting. MODEL SCALE CM511 0 to 10 RM51 RM52 RM53 RM54 0 to 50 °C 20 to 120 °C 10 to 90% R.H. 0 to 100% OTHER CHARACTERISTICS range 6 to 9 V d.c. for WT- WM - WF controllers for WH controllers for WA - WP - WQ - WV controllers Digital indicator Series WI500 - 6 channels selector - Supply 24 V a.c. - Panel or flush mounting, see terminal boards WM page 19. MODEL WI516 SCALE 3 ½ digit OTHER CHARACTERISTICS for connections to W controllers or IZ transducers Supply 15V d.c. supply for RX513/15/17 - CX528 and CM500. MODEL TL51 20 CHARACTERISTICS 24V a.c./15V d.c. (max 3 controllers) SUMMARY MENU FAN-COIL UNITS SYSTEMS 700 Line Analog Proportional and Microprocessor three points Control GENERAL INFORMATION Controllers They are electronic type with integral circuits, proportional time or three points output signal by TRIAC. They are used in air-conditioning, where it’s required the proportional control of valves on 2-4 pipe fan-coil units. Controlled devices The controlled devices are V-Z valve bodies with thermal actuator MVA4, and V-T valve bodies, with bidirectional actuator MVT4. BASIC SYSTEM ANALOG PROPORTIONAL SENSORS CONTROLLERS AUXILIARY MODULES MOTORIZED VALVES RA715 MVA4. V.Z MVA4. V.Z STA70 RT710 STR71 RM717 RA720 RT720 WT756 WT755 SBE BASIC SYSTEM MICROPROCESSOR THREE POINTS CONTROL SENSORS CONTROLLERS ACTUATORS MVT4 RA732 MVT4 VALVE BODIES V.T V.T RA734 MVT4 V.T 21 SUMMARY MENU FAN-COIL UNIT SYSTEMS 700 Line Fan-coil unit controllers Series RA700 - Room temperature controller with built-in sensing element and set-point selector. Proportional band 1 K - Supply 24 V a.c. - PWM (pulse with modulation) for driving V.Z. valve bodies with MVA4. actuator. Series RT700 - temperature controller using remote return-air duct or room sensor. MODEL SCALE °C ACTION OTHER CHARACTERISTICS RA715 RA725 15 to 26 15 to 26 summer or winter heating-cooling in sequence for 2-pipe fan-coil unit for 4-pipe fan-coil unit RT715 RT716 RT725 15 to 26 15 to 26 15 to 26 summer or winter summer or winter heating-cooling in sequence for 2-pipe fan-coil unit as above with internal set-point adjust for 4-pipe fan-coil unit Series RA730 - Room or duct sensor temperature microprocessor controller three points action for driving bidirectional actuator (1 or 2 in sequencing) model MVT4 or MVB46. Supply 24 V a.c. Wall mounting. MODEL SCALE °C ACTION RA732 5 to 32 heating-cooling in sequence set-point knob adjustment - 1 actuator MVT4 RA734 5 to 32 (2/4 pipe) (Fan. coil unit) digital set-point adjustment and temp. indication Fan speed selector and on-off switch ­ 2 actuators MVT4 in sequencing RA732 RA734 OTHER CHARACTERISTICS Auxiliary modules MODEL RM717 CHARACTERISTICS start-stop fan module for the proportional insertion of electric resistance max 10 A-250 V a.c. - insertion signal 5 V∼ remote potentiometer for set-point adjustment RT700 5 to 35 °C Temperature sensors Series ST... - Sensitive element: NTC 5000 Ohm at 20 °C MODEL STA71 STA77 STA78 STA79 STR71 STR72 OTHER CHARACTERISTICS room (dimensions 85 x 55 x 32 mm) for RT700 room with frontal set-point adjustment 5 to 35 °C (dimens. 115 x 85 x 32 mm) for RT700 as above with internal set-point adjustment room with set-point adjustment neutral (+/-) speed selector and on-off switch (dim.135x64x30 mm) return air duct with mounting kit for RT700 as above for RA732/734 Compensator modules Series WT755 - Summer compensation module of no. 100 RT700 max - Supply 24 V a.c. - Panel mounting Input from SBE sensors, see page 18. Series WT756 - Consisting of a WT module plus CM manual adjuster to change set-point of max 100 RT700 Mounting: panel mounting WT, flush mounting CM - Supply 24 V a.c. MODEL WT755 WT756 22 SCALE °C 5 to 15 to OTHER CHARACTERISTICS 35 26 compensation with authority 0 to 1, max 11 °C in respect to controller set-point set-point adjuster of RT700 controllers SUMMARY MENU FAN-COIL UNITS SYSTEMS RT200 3-Speed Fan-valve Sequence Control GENERAL INFORMATION The controllers RT200 are electronic type with integral circuits, output by TRIAC, 3 stages. They operate in sequence the fan-speed and the on-off valve V.Z with MVA2 thermal actuator, which can be N.O. or N.C. The temperature sensor is room type, with adjustable set-point, or duct type. BASIC SYSTEM SENSORS CONTROLLERS STA42 STR71 AUXILIARY MODULES CONTROLLED DEVICES FAN 2 - 3 vel. RT200 RM222 MVA 2. 1 x 2 tubs 2 x 4 tubs V.Z 1 x 2 tubs 2 x 4 tubs 3 stage fan-coil controllers Series RT200 - Summer/winter action - Output by relays for V.Z valve with actuators MVA and 3-speed fan control (stop-min.-med.-high) - Supply 230 V a.c. - Sensitive element: sensors ST-A42 - STR71 MODEL SCALE °C STEP DIFFERENTIAL K RT222 5 to 35 0.3 RT244 5 to 35 0.35 RM222 5 to 35 - OTHER CHARACTERISTICS open valve on min. fan speed - dead zone 0,4 K - for 2 pipe FC unit closed valve on min. fan speed - dead zone 0...6 K - for 4 pipe FC unit remote set-point adjustment Sensors for RT200 - Sensitive element: NTC5000 Ohm at 20 °C. MODEL ST-A42 STR71 OTHER CHARACTERISTICS room with adjustable set-point 5 to 35 °C (dimensions 115 x 85 x 32 mm) return air duct with mounting kit 23 SUMMARY MENU FAN-COIL AND VAV UNITS SYSTEMS DIGITROLL 7000 Microprocessor Control for Fan-coil and VAV Terminal Units GENERAL INFORMATION Controllers, microprocessor type are suitable to control FAN-COIL and VAV terminal units. They can operate stand-alone or by Control Unit, with 1 or 2 output signal P+I action. Control Unit, microprocessor type with LCD, can operate up to 160 controllers can be operated by Control Unit. The unit can communicate with printer and Building Management System through proper interface. Controlled device are: - 2 or 3 way valves with electrothermic actuator 24 V a. c. V.Z. -MVA4. or bidirectional actuator 24 V a. c. V.T.-MVT4 - damper actuators, bidirectional type, floating or proportional with input in V d. c. - Power supply 24 V a. c. BASIC SYSTEM CONTROL UNIT SENSORS CONTROLLERS CONTROLLED DEVICES NR7000 NC7311 STA70 STR71 Up to 160 controllers divided into 4 groups, 99 of them with individual parameters MVA/4 MVT4 V.Z V.T SPU75 RM77 FAN NR7320 MVA2 24 MVA2 SUMMARY MENU FAN- COILS AND VAV UNITS SYSTEMS DIGITROLL 7000 Control Unit Series NC7000 - with liquid crystal display (LCD) and pressure sensitive key board. Supply 24 V a.c. - Wall or flush mounting. MODEL OTHER CHARACTERISTICS NC7311 microprocessor supervision and Control unit to operate up to 160 controllers, communication by RS485 - yearly program, summer-winter compensation - power supply 24 V a.c. NC7311P As above with communication bus interface to supervisor -see page 26 Microprocessor controllers Series NR7000 - P + I action - 1.5 °C P.B. - All parameters set by Control Unit with possibility to operate stand­ alone - Power supply 24 V a.c. - Installation on track size 35 mm DIN 46277/3 - Sensitive element: ST sensors. OUTPUT MODEL No. TYPE NR7312 NR7412 NR7314 NR7414 1 1 2 2 TRIAC TRIAC TRIAC TRIAC NR7320 1 RELAYS SPDT OTHER CHARACTERISTICS 2-pipe fan-coil unit (drive V.Z/MVA4. valves, see pages 34 - 37) 2-pipe fan-coil unit (drive V.T/MVT4 valves, see pages 34 - 37) 4-pipe fan-coil unit (drive V.Z/MVA4. valves, see pages 34 - 37) 4-pipe fan-coil unit (drive V.T/MVT4 valves, see pages 34 - 37) 3-speed fan-control RM77 remote set-point adjuster + 3 K - Flush mounting RM77S as above with speed selector and on-off switch (dim. 135 x 64 x 30 mm) Sensors Series ST for temperature - Sensitive element: NTC5000 Ohm at 20 °C for NR controllers. MODEL STA71 STA75 STA80 STA81 STR71 OTHER CHARACTERISTICS room (dimensions 85 x 55 x 32 mm) room with + 3 K set-point, adjustment (dimensions 115 x 85 x 32 mm) room with + 3 K set-point and speed selector and on-off switch (dim. 135 x 64 x 30 mm) as above with comfort/stand-by state switch return air duct with mounting kit Address keys Series NS - Plug-in electronic card for identification of each controller by Control Unit. MODEL NS71 NS72 NS73 NS74 OTHER CHARACTERISTICS package with 40 pcs package with 80 pcs package with 120 pcs package with 160 pcs 25 SUMMARY FAN-COIL AND VAV UNITS SYSTEMS DIGITROLL 7000 SUPERVISIONIG SYSTEM for Fan-coil and VAV Terminal Units SUPERVISORS TERMINAL UNITS NR7312/14-NR7412/14 DG2DRV01 DG2300 NC7311P RS485 LONWORKS BUS HEATING/COOLING POWER STATIONS FLUIDS SUPPLY AHU NR7312/14-NR7412/14 DIGITROLL 2000 NC7311P RS485 26 MENU SUMMARY MENU FAN-COIL UNITS SYSTEMS TERMINAL UNITS CONTROL Controller Transmitters Action S/W Summer Changeover Compens. On/off Fan Man. selector fan speed 1 valve control 2 valve control 2 pos. prop./3 points 2 pos. prop./3 points Supply V a.c. AS202 Inside on/off Centralized X AS204 Inside on/off On board X AX212A Inside on/off Centralized X X X 230 AX212A STR74 on/off Centralized X X X 230 AX214 Inside on/off On board X X X 230 AX214 STR74 on/off On board X X X 230 RA732 Inside 3 points Individual X MVT4/V-T 24 RA732 STR72 3 points Individual X MVT4/V-T 24 RA734 Inside 3 points Individual X X MVT4/V-T 24 RA734 STR72 3 points Individual X X MVT4/V-T 24 MVA4/V-Z-B 24 RA715 Inside PI Centralized Analogic RA725 Inside PI Centralized Analogic RT715 STA71/77/78 STA79STR71 PI Centralized Analogic MVA4/V-Z-B Only with STA79 MVA4/V-Z-B MVA4/V-Z-B RT716 As above PI Centralized Analogic c.s. RT725 As above PI Centralized Analogic c.s. RT222 STA42STR71 PI Centralized RT244 STA42STR71 PI NR7312 STA71/75/80 STR71 PI NR7314 As above PI NR7412 As above 3 points NR7414 As above 3 points NR7320 As above P via bus via bus via bus 3 sequences c.s. 3 sequences c.s. via bus Only with STA80 via bus As above via bus As above via bus As above via bus 3 sequences 24 24 24 MVA4/V-Z-B X 24 230 X 230 MVA4/V-Z-B 24 MVA4/V-Z-B MVT4/V-T 24 MVT4/V-T X 24 24 24 2 position valve model: 2 way VSM-MVA2/VSZB (230 Vac), MVA4/VSZB (24Vac); 3 way VDM-MVA2/VMZB (230 Vac) MVA4/VMZB (24Vac); 3 way-4 connection MVA2/VTZB (230 Vac); MVA4/VTZB (24 Vac) 27 SUMMARY MENU DIGITAL SYSTEMS FOR HVAC DIGITROLL 2000 (Digitroll is CONTROLLI digital system trade mark). The below listed equipment is connected to LONWORKS communication bus: – DG2001/2 controllers: carries on monitoring and control operating strategies on heating and conditioning plants. Data processing and acquisition is referred - via communication bus - to I/O modules. The controller has no display panel, but one can always be applied plug-in. – DG2101 I/O module: configuration via communication bus from controller. The module receives and sends signals and controls both to and from the field. – PC: Thanks to DG2300 software the operator is able to operate the centralized management of all the controlled plants. Also available: – DG2200 display panel with keyboard for managing the controller. The panel can be either fitted to controller (DG2201A) by panel mounting or used as a portable device (DG22101B). – analogue to digital conversion module ( BASIC SYSTEM SUPERVISORS ( DG2300 DG2401 I/O MODULE CONTROLLER CONTROLLER DG2001M DG2002-DG2201A DG2001 DISPLAY PANEL I/O MODULE DG2201B SB-A/TT-A DG2101 VMB - VSB SM200 SM500 MVB50 SB/TU-D MDL20-50 SS - VS - DS - VB TP-D TQ-A SH500 - MVL50 3V - VM SENSORS TRANSMITTERS 28 ACTUATORS VALVE BODIES SUMMARY MENU DIGITAL SYSTEMS FOR HVAC DIGITROLL 2000 DIGITROLL 2000 (Digitroll is CONTROLLI digital system trade mark) Controller DDC controller working either stand - alone or within a supervision system for management and control of air­ conditioning and heating plants. It is connected via communication bus to one or more DG2101 I/O module (max. Nr 4 for DG2001, nr. 3 for DG2002) It is supplied without display panel. Panel mounting . Plastic case. Protection IP30. MODEL DESCRIPTION SUPPLY ABSORPTION DIMENSIONS 12 VA Digital controller without module I/0 fixed combinable strategies 24 V 320 x 200 x 70 mm As above with integrated card for 12 VA DG2001M a.c. individual modem 32 VA Digital controller on board module I/O DG2002 16I*/8O** * SB sensor (see page 18), ST - sensors (see page 22), Transmitters 0 ÷ 10 Vdc/4 ÷ 20-mA (see page 31). DG2001 I/0 Modules Module is connected via communication bus (shielded, twisted, bifilar cables) to DG2001(max n. 4 modules) or DG2002 (max, n. 3 modules) controller. Max distance of module from controller 1 km with optimized topology. Wall mounting. Plastic case. IP30 protection degree. MODEL DG2101 * INPUTS 16 univ* OUTPUTS 8 univ** SUPPLY ABSORPTION 24 V a.c. 32 VA DIMENSIONS 320 x 200 x 70 mm SB sensor (see page 18), ST - sensors (see page 22), Transmitters 0 ÷ 10 Vdc/4 ÷ 20-mA (see page 31). MODEL DG2801 DG2901 SERVICES Engineering for n. 1 DG2101 I/0 module (24 points) Start - up for n.1 DG2101 I/0-module Display panel The panel can be fitted (plug - in) to DG2001 controller, wall-mounted or used as a portable unit. Cable connection. IP30 protection degree. MODEL DESCRIPTION DIMENSIONS DG2201A A plug-in fitted on controller. 4 lines, 40 columns 8-key keyboard, signalling led 217 x 122 x 18 mm DG2201B As above with 3 m length cable for panel mounting or portable usage 217 x 122 x 18 mm System modem MODEL DG2401 OTHER CHARACTERISTICS For self-selecting asynchronous transmission Supervisors Software modules on high density (1,44) 3,5" microdisk. LONWORKS module to be installed on PC. Operative on Microsoft Windows NT, supervisors are likely to run on any INTEL/WINDOWS NT compatible PC. Instruction and programming manuals available. MODEL OTHER CHARACTERISTICS DG2301 FND-A, system configuration-installation, RTDB-A interface database; ADB-A alarm data base configuration management; PDB-A hystorical file configuration; PDD stored data display DG2302 As above with also GMSD, DDE and graphs development, current and memorized data analysis and generation DG2303 As DG2301 without PDB-A historical file configuration 29 SUMMARY MENU FIELD DEVICES They are the sensitive elements and controlled devices mounted on field, that is air handling units, heating and cooling power stations, batteries, exchangers, industrial processes, etc. Field devices are: TRANSMITTERS of temperature, humidity, pressure and air quality. Output signals: 0 to 10 V d.c. - 4 to 20 mA. DAMPER ACTUATORS, direct and crank-arm mounting type. On-off, floating, proportional controls. GLOBE VALVES ACTUATORS to motorize globe-valve bodies. On-off, floating, proportional controls. MOTORIZED VALVES, consisting of actuator/linkage valve body in compact construction, available for size up-to 2”. VALVE BODIES – globe type 2.way single seat, 2-way balanced, 2-way double seat, 3-way - body rating: 16 - 25 - 40 bar - size: 15 to 200 mm. – butterfly type, body rating 10 bar - size 40 to 200 mm. – shoe type, 3-4 port, body rating 10 bar - size: 25 to 100 mm. 30 SUMMARY MENU FIELD DEVICES Transmitters Temperature transmitters Output signal 0 to 10 V d.c. or 4 to 20 mA - “Integrated” sensitive element for WV - WA500 controllers, see page 18. RANGE °C MODEL TT-A31 TT-A21 TT-C31 TT-C21 TT-D21 TT-E31 TT-E21 0 to 0 to 0 to 0 -50 -50 -50 to to to to OUTPUT SIGNAL APPLICATIONS 50 50 100 0 to 10 V d.c. 4 to 20 mA 0 to 10 V d.c. 100 50 50 50 4 4 0 4 to to to to 20 20 10 20 mA mA V d.c. mA room - dimensions 115 x 85 x 32 mm as above immersion - with stainless steel well 113 mm length ­ ½” brass connection as above duct outside as above Output signal 4 to 20 mA - Sensitive element Pt 100 Ohm at 0 °C for controllers WA, see page 18. RANGE °C MODEL APPLICATIONS TT-C23 0 to 300 immersion - length 175 mm - stainless steel connection ½” gas, with stainless steel well connection ½” gas. TT-C24 0 to 500 as above Humidity transmitters Series TU - Sensitive capacitivity eIement 10 to 90% R.H. - For WH - WM557 controlIers, see pages 17-18. Series TUT - Humidity sensitive element and Balco 1000 Ohm at 21.1 °C temperature sensitive element - For WE - WH - WT - WM controllers, see pages 17-18. MODEL SIGNAL OTHER CHARACTERISTICS TU-A22 TU-A32 4to 20 mA 0 to 10 V a.c. TU-D22 TU-D32 4 to 20 mA 0 to 10 V d.c. TUTA32 0 to 10 V d.c./Ohm (temp.) TUTD32 0 to 10 V d.c./Ohm (temp.) room (dimensions 115 x 85 x 32 mm) - protection as above duct - rod ∅ 25 mm - length 200 mm - protection as above room (dimensions 115 x 85 x 32) temperature sensitive element - protection duct - rod ∅ 25 mm - lenght 200 mm with temperature sensitive element - protection Pressure and differential pressure transmitters Series TP - Output signal 0 to 10 V d.c. for WP560 controllers (TP-D), see page 19, and WV500 (TP-C), see page 18. MODEL TP-C31 TP-C32 TP-C33 TP-C341 TP-C351 TP-C361 TP-D311 TP-D321 TP-D331 RANGE 0 0 0 0 0 0 0 0 0 to to to to to to to to to 100 1000 2500 250 600 1000 100 1000 2500 MAX PRESSURE kPa kPa kPa kPa kPa kPa Pa Pa Pa 2000 2000 5000 1200 1200 1200 10000 10000 10000 kPa kPa kPa kPa kPa kPa Pa Pa Pa APPLICATIONS not aggressive gas and liquids differential pressure not aggressive gas and liquids pressure differential pressure liquids not aggressive air and not aggressive gas differential pressure Room air quality transmitters Series TQ - Output signal 0 to 10 V d.c. - supply 24 V a.c. for WQ533 controller, see page 19. MODEL TQ-A31 OTHER CHARACTERISTICS room - range 1 to 100% (dimensions 115 x 85 x 32 mm) 31 SUMMARY MENU FIELD DEVICES Actuators Damper actuators for direct mounting on the damper shaft Series SB - SM - SMR200 - Bidirectional motor - Hand drive device - Angular travel 90° - On-Off control. Protection IP42 MODEL TIMING s SB246 SM225 SM245 SMR226 SMR246 SMR226S SMR246S 80 to 110 90 to 150 80 150 (16) 150 (16) 150 (16) 150 (16) TORQUE Nm 4 15 15 15 15 15 15 POWER CONSUMPT. VA SUPPLY V a.c. 230±10% 24±20% 230±10% 24±20% 230±10% 24±20% 230±10% OTHER CHARACTERISTICS for dampers 0.8 m2 for dampers 3 m2 max for dampers 3 m2 max spring return type for dampers 3 m2 max as above with auxiliary contacts 12 4 13 10 11 10 11 Note: values in brackets express spring return timing. Series SM -SMR500 - Bidirectional motor with electronic card - Input signals: 2 to 12 V d.c. - Angular travel 90° - Supply 24 V a.c. Protection IP42. MODEL SM526 SMR526 TIMING s TORQUE Nm 100 to 200 150 (20) 15 15 POWER CONSUMPT. VA OTHER CHARACTERISTICS for dampers 3 m2 max spring return type for dampers 3 m2 max 3 10 Auxiliary contacts for SM225, SM245 and SM526 S1-1 S2-1 1 SPDT 10 (3) A-250 V a.c. adjustable on whole stroke as above but 2 SPDT Accessories for SM and SMR. To drive two dampers add KH8 KG8 crank-arm for damper shaft ∅ 10 to 18 or " 10 to 14 mm with slot 6.2 mm ball joint for KH8 crank-arm, ∅ 8 mm Actuators for dampers: crank-arm - linkage kit mounting type Series SH - Bidirectional motor with electronic card -Shaft ∅ 16 mm -Auto-manual device -Power consumption 9 VA - Angular travel 90° - Max damper surface m2 2.5 - Protection IP44. TIMING s TORQUE Nm SH225 SH245 45 45 12 12 24 230 SH525 45 12 24 MODEL SUPPLY V a.c. ACTION on-off floating control with electronic card and 300 Ohm feed-back potentiometer (500 Line - DG2000) range 6 to 9, 4 to 7, 8 to 11, 0 to 10 V d.c., 4 to 20 mA Accessories for SH MODEL D5 P1000-9 S10 YS7 S24H60 32 DESCRIPTION one end stroke auxiliary microswitch 1000 Ohm auxiliary potentiometer damper crank-arm ∅ 16 mm damper drive linkage in addition to S10 consisting of: crank-arm for damper shaft ∅ 12 mm joint connection, connecting rod ∅ 8 mm x 500 mm supply 24 V 60 Hz SUMMARY MENU FIELD DEVICES Actuators Actuators for dampers: crank-arm - linkage kit mounting type Series MDL - Bidirectional motor-Driving input signal P.C. board - 2 out-put shaft: main and seconds shaft § 9.5 x 9.5 mm - Force 500 N - Hand drive device - Protection IP 55. MODEL MDL22 MDL24 MDL26 MDL42 MDL44 MDL46 MDL62 MDL64 MDL66 MDL32 MDL34 MDL36 MDL52 MDL54 MDL56 TIMING s 90° - 160° TORQUE Nm 15 - 27 40 - 71 60 - 107 15 - 27 40 - 71 60 - 107 15 - 27 40 - 71 60 - 107 15 - 27 40 - 71 60 - 107 15 - 27 40 - 71 60 - 107 6 20 30 6 20 30 6 20 30 6 20 30 6 20 30 ANGULAR TRAVEL ADJUSTABLE 0 0 0 0 0 0 0 0 0 55 55 55 55 55 55 to to to to to to to to to to to to to to to 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 SUPPLY V a.c. 230 230 230 24 24 24 110 110 110 24 24 24 24 24 24 MAX DAMPER SURFACE m2 1.5 3.5 4.5 1.5 3.5 4.5 1.5 3.5 4.5 1.5 3.5 4 1.5 3.5 4.5 ACTION On-Off floating with 300 Ohm balance potentiometer (300 Line) with electronic card and 300 Ohm feed-back potentiometer (500 Line -DG2000) range 6 to 9, 4 to 7, 8 to 11, 1 to 5, 0 to 10 V d.c., 4 to 20 mA MDL20/40/60 can be supplied with auxiliary potentiometer 1 K Ohm. By ordering, add. PA to model, by ex. MDL24PA. MDL can be assembled with butterfly valves body, see pag 43. Options for MDL32-34-36. MDLS5 MDLV5 electronic card input signal range 6 to 9, 4 to 7, 8 to 11, 1 to 5 V d.c., 4 to 20 mA. electronic card input signal range 0 to 10 V d.c., 4 to 20 mA adjustable start point and span Accessories for MDL MODEL DESCRIPTION DMDL MDLA1 two auxiliary microswitch SPDT 10 (3) A - 240 V a.c. adjustable on the whole stroke damper drive linkage YS7 MDLA2 crank-arm in additional to MDLA1 linkage for mounting MDL when replacing SL MDLPA2 MDLPA4 MDLPA6 card with 1 K Ohm auxiliary potentiometer for MDL2 as above for MDL4 as above for MDL6 MDLPB2 MDLPB4 MDLPB6 card with 140 Ohm auxiliary potentiometer for MDL2 as above for MDL4 as above for MDL6 33 SUMMARY MENU FIELD DEVICES Actuators Actuators for zone valves and terminal units Series MVA2 - Electrothermal type - Two setting signal CONTROLLI 200 Line controllers, see page 4-5-9 and RT see page 22 - for V.Z valve bodies. Protection IP31. Series MVA4. - PWM (Pulse with modulation) Proportional and on-off 24 V a.c. electrothermal type - Driving signal from controllers 700 line, see page 22, DIGITROLL 7000 NR7312-7314 see page 25 - for V.Z valve bodies. Protection IP31. Series MVT4 - Bidirectional type - Driving signal from DIGITROLL 7000 NR7412-7414, see page 25, RA732/734 see page 22 - for V.T - V.BT valve bodies. Protection IP43. Series MVT5- Bidirectional type with microprocessor module for proportional signal 0 to 10; 0 to 4; 6 to 10; 2 to 10; 4 to 7; 6 to 9; 8 to 11 V d.c.. Driving signal from Line 500 and DIGITROLL 2000 for V.T - V.BT valve bodies. Protection IP40. INPUT SIGNAL CONSUMPTION VA 110 to 230 V a.c. 110 to 230 V a.c. 24 V a.c. 24 V a.c. three points 24 V a.c. three points 24 V a.c. proportional V d.c. 5 5 5 5 0.5 0.5 1 MODEL MVA21 MVA23 MVA41 MVA43 MVT4 MVT41 MVT5 OTHER CHARACTERISTICS with cable 1.5m without cable with cable 1.5m without cable with 1.5 m plug in cable without cable (see accessories) with cable 1.5 m Accessories D41 MVT4C1 MVT4C2 37T auxiliary switch for MVA 23 and MVA43 standard cable 1,5 m for MVT41 teflon cable 5 m for MVT41 strap-on type summer/winter change over snap-point 18/30 °C - SPDT 5A - 220 V a.c. for ½ “ pipe. Valve bodies: see page 37. Globe valve actuators Series MVB - Bidirectional motor for valve bodies VSB - VMB - VSB.F - VMB.F - VB7200 - VB7300 see pages 38-41 - Complete with linkage for mounting on valve body - Force 450 N. Protection IP50. MODEL TIMING s SUPPLY V a.c. CONSUMPTION VA OTHER CHARACTERISTICS MVB22 MVB26 MVB28 MVB46 30 65 420 65 230 230 230 24 5 5 5 5 MVB36 65 24 5 with electronic card and 300 Ohm balance potentiometer (300 Line) MVB52 MVB56 30 65 24 24 5 5 MVB55 65 24 5 with electronic card and 300 Ohm feed-back potentiometer range 6 to 9, 4 to 7, 8 to 11, 0 to 10, 2 to 10, 1 to 5 V d.c., 4 to 20 mA as above except only 0 to 10 V d.c MVBAV On-Off floating assembling MVB on valve bodies ATTENTION: Actuators are usually supplied NOT mounted on valve bodies. In case actuators and valve bodies are required assembled, the specific part number MVBAV will have to be listed on the order together with the models of actuator and valve body. Series SH - Bidirectional motor for all valve bodies, stroke 10 to 45 mm. Complete with linkage for mounting on valve body - For VSB - VSB.F - VMB - VMB.F only add AG21 accessory, see pages 38 - 41 - 42. Force 12 Nm. Protection IP40. MODEL TIMING s SUPPLY V a.c. CONSUMPTION VA OTHER CHARACTERISTICS SH222 SH242 SH522 80 80 80 24 230 24 9 9 9 On-Off floating On-Off floating with electronic card ad 300 Ohm feed-back potentiometer , range 6 to 9, 4 to 7, 8 to 11, 0 to 10, 2 to 10, 1 to 5 V d.c., 4 to 20 mA SH552 80 24 9 as above except only 0 to 10 V d.c. SH2AV Assembling SH on valve bodies. ATTENTION: Actuators are usually supplied NOT mounted on valve bodies. In case actuators and valve bodies are required assembled, the specific part number [SH2AV] will have to be listed on the order together with the models of actuator and valve body. Valve bodies: see pages 38 … 42. 34 SUMMARY MENU FIELD DEVICES Actuators Globe valve actuators Series MVL - For all valve bodies with self-adjusting stroke 10 to 45 mm - Complete with linkage for mounting on valve body - For VSB - VSB-F - VMB - VMB-F only add AG31 accessory, see pages 38…43 - Force MVL 1500 N, MVLA/C 700 N. Protection IP55. SUPPLY CON- 16.5 25 45 V a.c. SUMPTION MVL26 22 33 60 230 12 On-Off floating 230 V a.c. MVL46 22 33 60 24 12 On-Off floating 24 V a.c. MVL46A 22 (16) 33 (25) 60 (45) 24 12 On-Off floating 24 V a.c MVL46C 22 (16) 33 (25) 60 (45) 24 12 On-Off floating 24 V a.c 22 33 5 110 42 MODEL TIMING (s) VALVE STROKE MVL66 22 33 60 24 12 MVL36A MVL36 22 (16) 33 (25) 60 (45) 24 12 MVL36C 22 (16) 33 (25) 60 (45) 24 12 22 33 60 24 12 MVL55 22 33 60 24 12 MVL56A MVL56 22 (16) 33 (2) 60 (45) 24 12 MVL56C 22 (16) 3 (25) 60 (45) 24 12 MVLAV MVLMAV Note: OTHER ACTION CHARACTERISTICS with spring return valve stem up as above valve stem down On-Off floating 110 V a.c. with electronic card and 300 Ohm balance potentiometer (300 Line) with spring return valve stem up as above valve stem down with electronic card and 300 Ohm feed-back potentiometer, 0 to 10 V d.c. as above with range 4 to 7, 8 to 11, 0 to 10, 2 to 10, 1 to 5 V d.c., 4 to 20 mA with spring return valve stem up as above valve stem down assembling MVL on valve body assembling MVL A/C on valve body ( ) Return time by spring return. By spring return: MVLA stem-up, MVLC stem-down. ATTENTION: Actuators are usually supplied NOT mounted on valve bodies. In case actuators and valve bodies are required assembled, the specific part number MVLAV will have to be listed on the order together with the models of actuator and valve body, part number MVLMAV for actuators MVLA/C. Accessories for actuators MVB - MVL - SH MODEL DESCRIPTION D36 D5 DMVL one end stroke auxiliary microswitch adjustable on the whole stroke for MVB one end stroke auxiliary microswitch adjustable for SH two auxiliary microswitches adjustable on the whole stroke for MVL MVBPA2 1 kOhm auxiliary potentiometer for MVB46 P1000-1 P140-1 1000 Ohm auxiliary potentiometer for SH 140 Ohm auxiliary potentiometer for SH MVLPA2 MVLPA4 MVLPA4M MVLPA6 MVLHT 1000 Ohm auxiliary potentiometer for MVL26 1000 Ohm auxiliary potentiometer for MVL46 1000 Ohm auxiliary potentiometer for MVL46A/C 1000 Ohm auxiliary potentiometer for MVL66 Spacer for high temperature. To be used with valve bodies with fluid temp. higher than 150°C (SS, VSS, VBG, VBS, VMS, 3VAA, DS) Valve bodies: see pages 38 … 42. 35 SUMMARY MENU FIELD DEVICES Actuators Motorized valves - 200 Line - On-Off Series S300 - NP 16 valve body - Rubber-gasketed plug - Female screwed connections - Fluid: water 5 to 95°C On-Off unidirectional electric actuator - Manual override and position indication - Timing 40 s - Supply 230 V a.c. Protection IP40 MODEL S2303 S2304 S2305 S2306 S2308 S3303 S3304 S3305 S3306 S3308 SIZE Kvs MAX DIFF. PRESSURE kPa ¾” 1” 1¼” 1½” 2" ¾” 1” 1¼” 1½" 2" 6.3 10 16 25 40 6.3 10 16 25 40 300 200 140 100 60 300 200 140 100 60 OTHER CHARACTERISTICS TWO-WAY - cast-iron body THREE-WAY - cast-iron body Accessory D22 auxiliary microswitch SPDT 2(0.2)A - 250 V a.c. Series VSM/VDM - NP16 - Zone valves - On-Off - Timing: 12s, 3s (spring return) Manual override - Auxiliary microswitch * - Supply 230 V a.c. ** - Fluid water 2 to 95°C. SIZE Kvs MAX DIFF. PRESSURE kPa OTHER CHARACTERISTICS VSM1 VSM2 VSM3 1/2" 3/4" 1" 3,2 3,2 6,8 100 100 100 TWO-WAY - brass body VDM1 VDM2 VDM3 1/2" 3/4" 1" 4,3 4,6 5,7 100 100 100 THREE-WAY diverting - brass body MODEL * Closed when valve open. ** Also available 110 V a.c. - 24 V a.c. 36 SUMMARY MENU FIELD DEVICES Valve bodies Valves bodies for zone and fan-coil units Series V.T. - NP 16 forged brass valve body - Rubber gasketed plug. Equal-percentage flow characteristics. To be motorized with actuator MVT, see page 34. Series V.Z - NP 16 forged brass valve body - Rubber gasketed plug - Linear control flow characteristics To be motorized with actuators MVA, see page 34. Kvs MODEL STRAIGHTWAY ANGLEWAY MAX DIFFERENT PRESSURE kPa - 350 350 350 350 350 350 250 250 VST09 VST10 VST11 VST12 VST13 VST1 VST21 VST2 0.25 0.4 0.6 1 1.6 2.5 2.5 4 VMT09 VMT10 VMT11 VMT12 VMT13 VMT1 VMT2 0.25 0.4 0.6 1 1.6 2.5 4 0.25 0.25 0.4 0.6 1 1.6 2.5 350 350 350 350 350 350 250 VTT09 VTT10 VTT11 VTT12 VTT13 VTT1 VTT2 0.25 0.4 0.6 1 1.6 2.5 4 0.25 0.25 0.4 0.6 1 1.6 2.5 350 350 350 350 350 350 250 VSZ09B VSZ10B VSZ11B VSZ11BA VSZ12B VSZ12BA VSZ13B VSZ13BA VSZ1B VSZ1BA VSZ21B VSZ21BA VSZ2B VSZ2BA VSZ3 0.25 0.4 0.6 0.6 1 1 1.6 1.6 2.5 2.5 2.5 2.5 4 4 4 VMZ09B VMZ10B VMZ11B VMZ12B VMZ13B VMZ1B VMZ2B VMZ3B 0.25 0.4 0.6 1 1.6 2.5 4 4 0.25 0.25 0.4 0.6 1 1.6 2.5 2.5 150 150 150 150 150 150 150 150 VTZ09B VTZ10B VTZ11B VTZ12B VTZ13B VTZ1B VTZ21B VTZ3B 0.25 0.4 0.6 1 1.6 2.5 2.5 4 0.25 0.25 0.4 0.6 1 1.6 1.6 2.5 150 150 150 150 150 150 150 150 - 150 150 150 150 150 150 150 150 150 150 150 150 100 100 100 SCREWED CONNECTIONS TYPE two-way three-way three-way four port two-way three-way three-way four port STRAIGHT-WAY ANGLE-WAY n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. G G G G G G G G ½” M ½” M ½” M ½” M ½” M ½” M ¾” M ¾” M - n.c. n.c. n.c. n.c. n.c. n.c. n.c. G G G G G G G ½” M ½” M ½” M ½” M ½" M ½" M ¾” M G 1/2" M G 1/2" M G 1/2" M G 1/2" M G 1/2" M G 1/2" M G 3/4" M n.c. n.c. n.c. n.c. n.c. n.c. n.c. G G G G G G G ½" M ½" M ½" M ½" M ½" M ½" M ¾” M - n.c. n.c. n.c. n.o. n.c. n.o. n.c. n.o. n.c. n.o. n.c. n.o. n.c. n.o. n.c. G G G G G G G G G G G G G G G ½" M ½" M ½" M ½" M ½" M ½" M ½" M ½" M ½" M ½” M ¾” M ¾” M ¾” M ¾” M 1” M - n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. G G G G G G G G ½" M ½" M ½" M ½" M ½" M ½" M ¾” M 1” M G ½" M G ½" M G ½" M G ½" M G ½" M G ½" M G ¾” M G 1” M n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. G G G G G G G G ½" M ½" M ½" M ½" M ½" M ½" M ¾” M 1” M - All above valve bodies can be supplied with NPT connections. 37 SUMMARY MENU FIELD DEVICES Valve bodies 2-way single-seat, globe valve bodies Series VSB - VSB.F - NP 16. To be motorized by MVB - SH - MVL actuators, see pages 34-35. MODEL VSB11 VSB1 VSB15 VSB2 VSB3 VSB4 VSB5 VSB6 VSB8 VSB11F VSB1F VSB15F VSB2F VSB3F VSB4F VSB5F VSB6F VSB8F SIZE inch mm Kvs ½” R ½” R ½” R ½” ¾” 1” 1 ¼” 1 ½” 2” 1 1,6 2,5 4 6,3 8 16 22 30 15 R 15 R 15 R 15 20 25 32 40 50 1 1,6 2,5 4 6,3 8 16 22 30 STROKE MAX DIFFER. PRESS. bar mm MVB 16.5 2 (10) “ “ “ “ 2 (6,5) 2 (4) 2 (2,5) 2 2 (10) “ “ “ “ “ “ 2(8) 2 (6) 2 (10) “ “ “ “ “ “ 2 (4) 2 (3) 16,5 2 (10) “ “ “ “ 2 (6,5) 2 (4) 2 (2,5) 2 2 (10) “ “ “ “ “ “ 2 (8) 2 (6) 2 (10) “ “ “ “ “ “ 2 (6) 2 (8) SH-MVL OTHER CHARACTERISTICS MVL A/C - G 25 cast-iron body internal parts in bronze female screwed connections fluid temp.: -10* to 120°C - control flow characteristics equal-percentage - leakage 0.03% Kvs by actuator MVL add AG31 by actuator SH - ST add AG21 as above but with flanged connections NP16 ( ) Max close-off differential pressure by closed valve. * For applications free from icing on stem and packing. ** MVLA closed, MVLC open. Series VSBT NP16 - To be motorized by MVT actuators, see page 34. MODEL SIZE Kvs inch VSBT3 VSBT4 VSBT5 VSBT6 ¾" 1" 1 1/4" 1 1/2" 6,3 10 13 16 STROKE MAX DIFFER. PRESS. bar mm MVT 5,5 5,5 5,5 5,5 1,7 1 0,7 0,5 OTHER CHARACTERISTICS - control flow characteristics linear - leakage 0,03% Kvs - fluid temp. 5° to 95°C 2-way bronze valve bodies Series VB7200 NP 16 – To be motorized by MVB actuators, see page 34, AG40 see page 43. MODEL SIZE Kvs mm inch VB7225-02 VB7225-04 VB7225-06 VB7225-08 VB7225-09 VB7225-10 VB7225-11 ½” ½” ¾” 1” 1 ¼” 1 ½” 2” STROKE 1,9 3,8 6,5 12 17 24 35 12,7 12,7 12,7 12,7 12,7 12,7 12,7 MAX DIFFER. PRESS. bar 2 (10) “ “ 2 (6,5) 2 (4) 2 (2,5) 2 (2) ( ) Max close-off differential pressure by closed valve. * For applications free from icing on stem and packing 38 OTHER CHARACTERISTICS MVB - NP 16 bronze body - internal parts in bronze Female G screwed connections fluid temp.: -7* to 138 °C - control flow characteristics: equal-percentage - Leakage: Straight-way: 0.01 % Kvs - By actuators MVB add AG40 SUMMARY MENU FIELD DEVICES Valve bodies 2-way single-seat, globe valve bodies Series VSG - SS - To be motorized by SH - MVL actuators, see pages 34-35, and ST402, see page 12. MODEL SIZE Kvs mm mm VSG (NP 16) SSGA (NP 16) VSS (NP 25) SSAA (NP 40) SSAACP *** (NP 40) STROKE MAX DIFFER. PRESS. bar SH-ST MVL MVL ** A/C 25 R 25 I 25 40 50 65 80 100 125 150 4 6,3 10 20 32 63 100 130 200 300 16,5 " " 25 " " 45 " " " 2 (10) " " 2(7,5) 2(6) 2(3,6) 2(1,7) 0,8 0,5 0,3 2 (10) " " 2(9,5) 2(6) 2(2,3) 1,4 1,4 0,8 0,4 2(10) " " 2(3,5) 2(2,4) 0,8 0,4 0,4 - 15 15 20 25 32 40 50 65 80 100 25 25 25 32 40 50 65 15 15 20 25 32 40 50 65 80 100 1,6 4 6,3 10 16 22 32 70 110 140 4 6,3 10 16 25 40 63 1,6 4 6,3 10 16 22 32 70 110 140 16,5 " " " 25 " " " 45 " 16,5 " " 25 " " " 16,5 " " " 25 " " " 45 45 6(16) " " " " 6(10) 6(7) 2,5 1,5 1 8(16) " " 7,5(10) 7 5 2,7 6(16) " " " " 6(10) 6(7) 2,5 1,5 0,8 6(16) " " " " 6(13,3) 6(9) 3,5 2,3 1,4 8(20) " " 8(13) 7,5(9) 6,3 3,5 10(30) " " 10(20) " 10(13) 8 3,5 2,3 1,4 6(16) " 6(14) 6(9) " 5,5 3,5 1,4 0,9 0,5 7(10) " " 5,5 4 2,5 1,4 10(30) 10(20) 10(12) 7,5 7,5 4,3 2,8 1 0,8 0,4 1,6 4 6,3 10 16 22 32 70 110 140 16,5 “ “ “ 25 “ “ “ 45 45 6(16) “ “ " “ 6(10) 6(7) 2,5 1,5 0,8 10(30) " " 10(20) " 10(13) 8 3,5 2,3 1,4 10(30) 10(20) 10(12) 7,5 7,5 4,3 2,8 1 0,8 0,4 R R I R 15 R 15 20 25 32 40 50 65 80 100 OTHER CHARACTERISTICS - G 25 cast-iron body internal parts in bronze NP 16 flanged connections fluid temp.: - 10* to 120 °C ­ control flow characteristics equal-percentage - leakage 0.03% Kvs - G 25 cast-iron body internal parts in stainless steel NP 16 flanged connections fluid temp.: - 10* to 200 °C - control flow characteristics equal-percentage - leakage 0,02% Kvs - G 308 cast-iron body internal parts in stainless steel NP 25 flanged connections fluid temp.: -10* to -230°C - control flow characteristics equal-percentage - leakage 0,02% Kvs - Fe 52 cast-steel body internal parts in stainless steel NP 40 flanged connections fluid temp.: - 10* to 230 °C - control flow characteristics equal percentage - leakage 0,02% Kvs - Fe 52 cast-steel body with extension cooling internal parts in stainless steel with grease-cap and special sealings for high temperature NP 40 flanged connections fluid temp.: - 30*** to 350°C - control flow characteristics equal-percentage - leakage 0,02% Kvs ( ) Max close-off differential pressure by closed valve. * For applications free from icing on stem and packing. ** VSG-VSS: by spring return MVLA closed, MVLC open. SS: by spring return MVLA open, MVLC closed. *** Fluid applications < -10 °C by ordering add. "B" to model, by ex. SSAACP40B. Options for valve bodies: see page 43. 39 SUMMARY MENU FIELD DEVICES 2-way balanced seat valve bodies Serie VBS - VBG. To be motorized by SH-MVL actuators, see pages 34-35, and ST402, see page 12. MODEL DN Kvs STROKE mm VBS (PN 25) VBG (PN 16) 25 R 25 25 32 40 50 65 80 100 125 150 4 6,3 10 16 25 40 63 100 130 200 300 16,5 “ “ 25 “ “ “ 45 “ “ “ MAX. DIFF. PRESS. bar SH-ST 7 (25) “ “ “ “ “ “ 2 (16) 2 (16) 2 (13,5) 2 (10,5) MVL MVL** A/C 7 (25) “ “ “ “ “ “ 2 (16) 2 (16) 2 (16) 2 (14,5) 7 (25) “ 7 (23,5) 7 (16,5) 7 (10) “ “ 2 (10) 2 (8) 2 (5,5) 2 (4,5) Valve bodies OTHER CHARACTERISTICS - G308 spheroidal cast-iron body internal parts stainless steel NP 25 flanged connections fluid temp.: -10* to 230°C - control flow characteristics equal percentage - leakage 0,02% Kvs - G25 cast-iron body internal parts in bronze NP 16 flanged connections fluid temp.: -10* to 150°C - control flow characteristics equal percentage - leakage 0,03% Kvs 2-way double-seat globe valve bodies Series DS - To be motorized by SH - MVL actuators, see pages 34-35. MODEL SIZE Kvs mm mm DSGA (NP 16) DSAA (NP 40) DSAACP (NP 40) () * ** *** STROKE MAX DIFFER. PRESS. bar SH-MVL OTHER CHARACTERISTICS MVL *** A/C 32 R 32 40 50 65 150 200 10 16 22 32 63 300 500 16,5 “ 25 “ “ 45 “ 8 (16) “ “ “ “ 8 (14) 8 (9) 8 (16) “ “ “ “ 8 (9) - - G 25 cast-iron body internal parts in stainless steel NP 16 flanged connections fluid temp.: -10* to 200 °C - control flow characteristics equal-percentage - leakage 0,12 % Kvs 32 R 32 40 50 65 80 100 125 150 10 16 22 32 63 85 160 200 300 16,5 “ 25 “ “ “ 45 “ “ 12 (30) “ “ “ “ “ 12 (20) “ 12 (14) 12 (30) “ “ “ 12 (14) 11 8,5 8 7 - Fe 52 cast-steel body internal parts in stainless steel NP 40 flanged connections fluid temp.: - 10* to 230 °C - control flow characteristics equal-percentage - leakage 0,12 % Kvs 32 R 32 40 50 65 80 100 125 150 10 16 22 32 63 85 160 250 300 16,5 “ 25 “ “ “ 45 “ “ 12 (30) “ “ “ “ “ 12 (20) “ 12 (14) 12 (30) “ “ “ 12 (14) 11 8,5 8 7 - Fe 52 cast-steel body with extension cooling internal parts in stainless steel with grease-cap and special sealings for high temperature NP 40 flanged connections fluid temp.: - 30***to 350 °C - control flow characteristics equal-percentage - leakage 0,12 % Kvs Max close-off differential pressure by closed valve. For applications free from icing on stem and packing. By spring return VBG and VBS MVLA close, MVLC open, DS MVLA open, MVLA close Fluid applications < -10 °C by ordering add. "B" to model, by ex. DSAACP40B. Options for valve bodies: see page 43. 40 SUMMARY MENU FIELD DEVICES Valve bodies 3-way single-seat, globe valve bodies Series VMB - VMBF - NP 16. To be motorized by MVB - SH - MVL actuators, see pages 34-35. MODEL VMB11 VMB1 VMB15 VMB2 VMB3 VMB4 VMB5 VMB6 VMB8 VMB11F VMB1F VMB15F VMB2F VMB3F VMB4F VMB5F VMB6F VMB8F SIZE inch mm ½” R ½” R ½” R ½” ¾” 1” 1 ¼” 1 ½” 2” 15 R 15 R 15 R 15 20 25 32 40 50 Kvs 1 1,6 2,5 4 6,3 8 16 22 30 1 1,6 2,5 4 6,3 8 16 22 30 STROKE MAX DIFFER. PRESS. bar mm MVB SH-MVL MVL ** A/C 16,5 2 (10) “ “ “ “ 2 (6,5) 2 (4) 2 (2,5) 2 2 (10) “ “ “ “ “ “ 2(8) 2 (6) 2 (10) “ “ “ “ “ “ 2 (4) 2 (3) 16,5 2 (10) “ “ “ “ 2 (6,5) 2 (4) 2 (2,5) 2 2 (10) “ “ “ “ “ “ 2 (8) 2 (6) 2 (10) “ “ “ “ “ “ 2 (6) 2 (8) OTHER CHARACTERISTICS - G 25 cast-iron body internal parts stainless steel NP 16 flanged connections fluid temp.: -10* to 120°C - control flow characteristics equal-percentage - leakage 0.03% Kvs by actuator MVL add AG31 by actuator SH - ST add AG21 as above but with flanged connections NP16 ( ) Max close-off differential pressure by closed valve. * For applications free from icing on stem and packing. ** MVLA closed, MVLC open. Serie VMBT NP 16 - To be motorized by MVT actuators, see page 34. MODEL SIZE Kvs STROKE MAX. DIFFER. PRESS. bar mm MVT 5.5 1.7 1 VMBT3 ¾” VMBT4 1” 10 5.5 VMBT5 1 ¼” 13 5.5 0.7 VMBT6 1 ½” 16 5.5 0.5 6.3 OTHER CHARACTERISTICS - control flow characteristics linear - fluid temp.: 5 to 95°C 3-way bronze valve bodies Series VB7300 – NP 16 – To be motorized by MVB actuators, see page 34, AG40 see page 43. MODEL SIZE Kvs mm inch VB7315-02 VB7315-04 VB7315-06 VB7315-08 VB7315-09 VB7315-10 VB7315-11 ½” ½” ¾” 1” 1 ¼” 1 ½” 2” STROKE 1,9 3,8 6,5 12 17 24 35 12,7 12,7 12,7 12,7 12,7 12,7 12,7 MAX DIFFER. PRESS. bar 2 (10) “ “ 2 (6,5) 2 (4) 2 (2,5) 2 (2) ( ) Max close-off differential pressure by closed valve. * For applications free from icing on stem and packing. 41 OTHER CHARACTERISTICS MVB - NP 16 bronze body - internal parts in bronze Female G screwed connections fluid temp.: -7* to 138 °C - control flow characteristics: linear - Leakage: Straight-way: 0.2 % Kvs - By actuators MVB add AG40 SUMMARY MENU FIELD DEVICES Valve bodies 3-way valve bodies Series VM - 3V - To be motorized by MVL - SH actuators, see page 34-35, and ST402, see page 12. MODEL VMB16 (NP 16) 3VGA (NP 16) VMS (NP 25) 3VSA (NP 25) VMSTS (NP 25) 3VSATS (NP 25) 3VAA (NP 40) 3VAACP ** (NP 40) () * ** *** SIZE mm Kvs 25 R 25 I 25 40 R 40 50 65 80 100 125 150 4 6,3 10 19 25 32 63 100 130 200 300 100 125 160 250 STROKE MAX DIFFER. PRESS. bar mm SH - ST MVL MVL ** A/C 16,5 “ “ 25 “ “ “ 45 “ “ “ 2 (10) “ “ 2 (8) “ 2 (5) 2 (3) 1,8 1 0.6 0.4 2 (10) “ “ “ “ 2 (6.7) 2 (4) 2(2.4) 1.5 0.9 0.5 2 (8) “ “ 2 (4) “ 2 (2.6) 1.5 0.9 0.5 0.25 0.15 OTHER CHARACTERISTICS - G 25 cast-iron body internal parts in bronze NP 16 flanged connections fluid temp.: - 10* to 120 °C - control flow characteristics straight-way: equal-percentage angle way: linear - leakage: straight-way: 0.03% Kvs angle way: 2% Kvs 45 45 1 0.5 1.3 0.8 0.5 0.2 - G 25 cast-iron body internal parts in stainless steel NP 16 flanged connections fluid temp : -10* to 200 °C - control flow characteristics: linear - leakage 0.02% Kvs - G-308 spheroidal cast-iron body internal parts in stainless steel NP 25 flanged connections fluid temp.: -10* to 230°C - Control flow characteristics: linear - leakage 0.02% Kvs 25 R 25 I 25 32 40 50 65 80 4 6,3 10 19 25 40 63 100 16,5 " " 25 " " " 45 16(16) " " 6(10) 6(7) 5 2,5 1,5 6(16) " " 6(14) 6(9) 6 3,5 2 6(9) " " 5,5 3,5 2,5 1,4 0,8 25 R 25 I 25 32 40 50 65 80 4 6,3 10 19 25 40 63 100 16,5 16,5 “ 25 “ “ “ 45 6 5 “ “ “ “ 2,5 1,5 6 5 “ “ “ “ 3 2 6 5 5 4 2,5 1,5 1 0,5 25 R 25 25 32 40 50 65 80 100 125 4 6,3 10 16 22 32 70 110 140 250 16,5 " “ 25 “ “ “ 45 " " 6(16) “ “ 6(10) 6(7) 5 2,5 1,5 - 10(20) " “ 10(13) 8,5 5,5 3,5 2 1,3 0,8 7,5 " " 4,5 3 2 1 0,7 0,4 0,2 25 R 25 32 40 50 65 80 100 125 4 10 16 22 32 70 110 140 250 16,5 “ 25 “ “ “ 45 “ “ 6(16) “ 6(10) 6(7) 5 2,5 1,5 - 10(20) “ 10(12) 8 5,5 3,5 2 1,3 0,8 6,8 6,8 4,3 2,8 2 1 0,7 0,4 0,2 - G 308 spheroidal cast-iron body internal parts in stainless steel with bellows seal NP 25 flanged connections fluid temp.: -10* to 300 °C - control flow characteristics: linear - leakage 0,02% Kvs - Fe 52 cast-steel body internal parts in stainless steel NP 40 flanged connections fluid temp.: -10* to 230 °C - Control flow characteristics: linear - leakage 0,02% Kvs - Fe 52 cast-steel body with extension cooling internal parts in AISI 316 stainless steel with grease-cap and special sealings for high temperature NP 40 flanged connections fluid temp.: - 30*** to 350 °C - control flow characteristics: linear - leakage 0,02% Kvs Max close-off differential pressure by closed valve. For applications free from icing on stem and packing. By spring return: MVLA closed straight-way, MVLC open Fluid applications < -10 °C by ordering add. "B" to model, by ex. 3VAACP40B Options for valve bodies see page 43. 42 SUMMARY MENU FIELD DEVICES Valve bodies Options valve bodies MODEL A125-2 A125-3 A150-2 A150-3 A300-2 A300-3 244 245 246 OTHER CHARACTERISTICS flanges ANSI 125 for SSGA and DSGA valves flanges ANSI 125 for 3VGA valves flanges ANSI 150-RF for SSAA and DSAA valves flanges ANSI 150-RF for 3VAA valves flanges ANSI 300 for SSAA and DSAA valves flanges ANSI 300 for 3VAA valves stem heater for valve VSB/VSB-F- VMB/VMB-F motorized with MVB, supply 24 V a.c. as above for valves SS-VSG-DS-VM-3V-VBG-VBS motorized SH, ST, MVL supply 24 V a.c. as above for valves VSB/VSB-F- VMB/VMB-F, motorized with SH, MVL - supply 24 V a.c. Accessories for assembling actuators to valve bodies Series MVB - MVL - SH - ST actuators are already fitted with linkage. When necessary the following accessories are available. 43 AG21 for mounting SH - ST on VSB - VSB-F - VMB - VMB-F (page 38, 41) AG23 for mounting MVB on Cazzaniga/TA valve body AG31 for mounting MVL on VSB - VSB-F - VMB - VMB-F (page 38, 41) AG40 for mounting MVB on VB7225/7315 bronze valve (page 38, 41) SUMMARY MENU FIELD DEVICES Valve bodies Butterfly valve bodies Series VF - To be motorized by: ST 404/405, see page 12 or MDL/AF, see pag 33. MODEL VFG10 (NP 10) SIZE Kvs MAX DIFFERENTIAL PRESSURE kPa WITH ACTUATORS ST 405 and MDL 40 50 65 80 100 125 150 200 85 130 220 340 550 900 1400 2500 200 200 200 200 150 100 70 40 OTHER CHARACTERISTICS - G 25 cast-iron valve body connections: flangeless wafer butterfly for UNI NP 10 flanges fluid temp.: 120 °C max - leakage: 0.3% Kvs Linkages and assembling for butterfly valves with actuators MDL AF22 linkage and strain release mechanism with position indicator MDLAV assembly MDL on the VFG 10 valve Shoe valve bodies Series M - Cast-iron NP 6 - To be motorized by: ST 404/405 actuators fitted with AM linkage, see page 12. MODEL SIZE Kvs MAX DIFFERENTIAL PRESSURE kPa WITH ACTUATORS: ST404 / ST 405 Construction (for connection type) OTHER CHARACTERISTICS 1” 1¼” 1½” 2” 16 25 40 63 100 100 100 100 AM52 AM52 AM52 AM52 -THREE-WAY NP 6 cast-iron valve body female screwed connections output from angle-way fluid temp.: 110 °C max 40 50 65 80 100 40 63 100 160 250 100 100 80 50 30 AM44 AM52 AM52 AM52 AM52 as above but flanged connections M4 (NP 6) 1” 1¼” 1½” 2” 16 25 40 63 100 100 100 100 AM52 AM52 AM52 AM52 FOUR-WAY NP 6 cast-iron valve body female screwed connections fluid temp.: 110 °C max M4 (NP 6) 50 65 80 100 63 100 160 250 100 80 50 30 AM52 AM52 AM52 AM52 as above but flanged connections M3 (NP 6) M3 (NP 6) Linkages for shoe valves Series AM - Linkages and strain release mechanism for M3 - M4 valves. AM44 for valves M3 size 40 mm AM52 for valves M3 and M4 all size except M3 DN40 44 SUMMARY MENU CONTROL VALVES SIZING HOW TO CALCULATE KVs Flow coefficient KVs is the quantity of water in m3/hr which goes through the valve, when fully open, by pressure drop of 1 kg/cm2. Data: − quantity of fluid that the valve must supply to the systems (m3/hr) − valve inlet pressure (bar) • Design the pressure drop through the valve, • Calculate the KVs necessary for the valve: Q ⋅ 10 a) water KVs = ∆pv Q = flow (m3/hr) ∆pv = pressure drop (kPa) QC ⋅ 10 b) saturated steam KVs = 22.7 P2 ∆p Q = flow (kg/hr) C = 1 + 0,0013 (t-ts) t = steam temperature in working conditions ts = saturated steam temperature at pressure P2 P2 = outlet pressure (kPa) ∆p = pressure drop (kPa) Choose the valve with the KVs closest to the calculated one. PRACTICAL SUGGESTIONS FOR PRESSURE DROP SELECTION. WATER SYSTEM Two-way valve For this application, pressure drop through the valve must be high in order to have a good control flow characteristic and a properly working system. 1) Pressure drop of valves must be 30 to 50% of pressure drop of systems. 2) Pressure drop of valves must be equal to, or higher than pressure drop of battery or heat exchanger under control, more precisely: temperature drop of heat exchanger design pressure drop of valves 30 °C equal to pressure drop of heat exchanger 20 °C twice as pressure drop of heat exchanger 10 °C three times as pressure drop of heat exchanger 3-way mixing valve For mixing valve a high pressure drop is not normally required even when used in primary and secondary water to control supply temperature to users. As a general rule the valve must have a pressure drop similar to that one of heat exchanger. 3-way diverting valve 3-way diverting valves are used to control flow to heat exchanger and therefore pressure drop through valve, for proportional systems, must be high. Note: When selecting pressure drop you must not exceed the above mentioned values because a valve that is too small could produce: - noisy operation and vibration of the plug - accelerated wear of the plug and seat due high velocity of fluid through the valve. SUPERHEATED WATER SYSTEM For this application the used valves are two or three-way types. Pressure drop of valve must be high, in order to have a good control flow characteristic and a properly working system. The principles and rules for correct sizing are as per "WATER SYSTEMS". STEAM SYSTEM For low pressure steam systems (up to 2 bar), pressure drop through the valve must be 60 to 80% of pressure available at valve inlet. steam pressure valve inlet valve pressure drop 0.5 bar 50 kPa, 40 kPa 1.0 bar 100 kPa 70 kPa For high pressure steam systems (above 2 bar) pressure drop through the valve must be 30 to 40% of pressure available at valve inlet. steam pressure valve inlet valve pressure drop 200 kPa 80 kPa 600 kPa 200 kPa 1000kPa 300 kPa For two-position valves there are no particular rules to follow, pressure drop may be 10 to 20 % of inlet pressure, but valve is normally pipe sized. Note: Do not size valve for high pressure steam with pressure drop higher that 50% of absolute available pressure, beyond this percentage thermodynamic problems could affect valve efficiency and life. THERMAL OIL SYSTEMS The commonest valve type used is three-way with linear characteristics in order to assure a constant flow to boiler by constant speed. Two-way valves can be utilized for several low-power users and where a balancing valve is mounted between supply and return boiler. Pressure drop of three-way valve must be at least equal to or higher than that one of heat exchanger. For a single user control valve must have a pressure drop 30 to 50% of pressure drop of system. For two-way valves see the "WATER SYSTEMS" section. 45 SUMMARY MENU CONTROL VALVES SIZING FOR FLUIDS FLOW liquid with specific gravity 1 kg/d3 m3/h Kvs = Q ⋅ 10 ∆pv Q = flow m3/h ∆pv = pressure drop (kPa) Flow pressure drop kPa FLOW liquid with specific gravity 1 kg/d3 different than 1 kg/dm3 m3/h Specific gravity (100 kPa = 1 bar = ∼ 10 m H2O) Example for fluids with specific gravity different than 1 kg/dm3 FLOW : 30 m3/h fluid with specific gravity 0.9 kg/dm3 PRESSURE DROP : 20 kPa − Locate the crossing point (right side of diagram) between the line with starting point at specific gravity value 0.9 kg/dm3 and the sloping line at flow value 30 m3/h. − Locate the crossing point between the line with starting point at above crossing point and the line at pressure drop value 20 kPa. This point corresponds to flow coefficient Kvs 63, therefore control valve must have size Kvs = 63 (DN65). Example for fluids with specific gravity 1 kg/dm3 (water) FLOW : 7.5 m3/h water PRESSURE DROP : 55 kPa − Locate the crossing point between the line with starting point at flow value 7.5 m3/h and the line at pressure drop value 55 kPa. This point corresponds to flow coefficient Kvs 10, therefore control valve must have Kvs = 10. 46 SUMMARY MENU CONTROL VALVES SIZING FOR STEAM Kg/h °C kPa Example for saturated steam: FLOW : 4700 kg/h saturated steam ABSOLUTE INLET PRESSURE: 850 kPa PRESSURE DROP : 160 kPa − Locate the crossing point between the line with starting point at absolute inlet pressure 850 kPa and the sloping line of 160 kPa pressure drop. − Locate the crossing point between the line with starting point at above crossing point and the line of 4700 kg/h flow. This point corresponds to flow coefficient Kvs 63, DN 65, therefore control valve must have size 65 mm, Example for superheated steam: FLOW : 140 kg/h superheated steam ABSOLUTE INLET PRESSURE : 350 kPa TEMPERATURE : 209 °C PRESSURE DROP : 100 kPa Calculate the superheating degree as follows: − Read the temperature value corresponding to 350 kPa (139 °C) Superheating degree - 209 - 139 = 70 °C − Locate the crossing point (right side of diagram) between the line with starting point at superheating 70 °C and the sloping line of 140 kg/h flow. − Locate the crossing point between the line with starting point at 350 kPa inlet pressure and the sloping line at 100 kPa pressure drop. − Locate the crossing point between lines with starting points. This point corresponds to flow coefficient Kvs 4. 47 SUMMARY MODELS IN ALPHABETICAL ORDER A A1 to 4 A125/150/300 AF22 AG AM AS202/24 AX212/214/235 AX525 PAGE 5-7 43 44 43 44 4 9 17 B B301 to 304 B301X to 304X B351 to 354 B351X to 354X BD295 5 5 7 7 5 C C306 to 310 C306S C356 to360 C356S CM350 CM511 CP8511/8551/8552 CX228 CX528 4 4 7 7 7 20 19 9 10 D D5 D22 D36 D41 D77 DG2000 DIGISTAT DMDL DMVL DSAAA DSAACP DSGA 32-35 36 35 34 12 27 9 33 35 40 40 40 F F1 FG600 FG650 11 5 7 G G1 G4 GS541/2/3 4-7 4-7 19 I IZA - IZB - IZV 20 K KG8 KH8 KX435G/S - 436G/S 32 32 11 M MDL20/30/40/50/60 M3-M4 MDLA MDLAV 33 44 33 44 MDLS5 MDLV5 MDLPA-MDLPB MM501 MVA MVB22/26/28/36/46 MVB52/55/56 MVBAV MVBPA1/PA2 MVL MLA/C MVLAV-MVLMAV MVLHT MVLPA2/PA4/PA6 MVT MW1 - MW2 MWD1 - MWD2 PAGE 33 33 33 19 34 34 34 34 35 35 35 35 35 35 34 19 19 N NC7311 NR7000 NS71 to 74 25 25 25 P P140-1 P1000-1 P1000-9 35 35 32 R R1 RA715/725/732/734 RK4113 RKA11/41 RM51 to 54 RM77 RM77S RM222 RP4102 RT222 RT244 RT715/716/725 RX513/515/517 4-7 22 14 14 20 14-25 25 23 14 23 23 22 17 S S1-1 S2-2 S2/3 303 to 308 S10 S24H60 SB246 SBA SBA20/55 SBC SBD SBE SBF SBV SH222/242 SH225/245 SH2AV SH522/552 SH525 SM225/245 SM526 SMR226/246 SMR226S/246S SMR526 SNC - SNE - SNF 32 32 36 32 32-35 32 18 18 14-18 18 14-18 14 18 34 32 34 34 32 32 32 32 32 32 11 SPC SSAA SSAACP SSGA ST2AV-ST5AV ST402/404/405 STA42 STA71 STA75/76 STA77/78/79 STA80/81 STR71 STR72 PAGE 10 39 39 39 12 12 23 22-25 25 22 25 23-25 22 T T4-20 TL51 TPC TPC-2 TP-C3. TP-D3. TQ-A31 TT-A21/31 TT-C21/22/31 TT-C23-24 TT-D21/31 TT-E21/31 TU-A-TU-D TUTA-TUTD TX283 TX581/586 10 20 10 10 31 31 31 31 31 31 31 31 31 31 9 10 Y Y100/101 Y110/110RM YS7 YTC3 - YTC3RM YZB PAGE 5 4 32-33 5 4 2 244 to 246 43 3 3VAA 3VAACP 3VGA 3VSA 3VSATS 37T 42 42 42 42 42 34 4 421 10-18 U UF215/216 4 V VB7225 VB7315 VBG VBS VDM VFG10 VMB - VMB-F-VMBT VMB16 VMS VMSTS VMT-VST-VTT VMZ-VSZ-VTZ VSB - VSB-F-VSBT VSG VSM VSS 38 41 40 40 36 44 41 42 42 42 37 37 38 39 36 39 W WD542/544 WE593 WF594 WH272 WH572/574 WI516 WM551 to 555/557 WP562 WQ533 WS506 WT223/225 WT513/515 WT533/535 WT543/544 WT755/576 WV511/539 19 18 17 18 18 20 17 19 19 19 17 17 17 17 22 18 48 MENU SUMMARY SALES AND SERVICE ORGANIZATION CONTROLLI S.p.A. Head Office and Factory: 16010 Sant’Olcese Ge Italy via C. Levi, 52 Telephone +39 01073061 Facsimile +39 0107306203 E mail [email protected] Representation bureau in Paris: 7 Rue Albert Einstein Cité Descartes 77420 Champs sur Marne France Telephone +33 (0)1 64683995 Facsimile +33 (0)1 64680545 FOREIGN AUTHORIZED DISTRIBUTORS AND DEALERS ARGENTINA MALAYSIA AUSTRIA MEXICO AUSTRALIA NEW ZELAND BELGIUM PHILIPPINES CANADA PORTUGAL CHINA SINGAPORE FRANCE SPAIN GREECE SWEDEN GERMANY SWITZERLAND HOLLAND TAIWAN HONG KONG THAILAND KOREA U.K. INDONESIA U.S.A. IRAN VENEZUELA PLEASE CONTACT OUR EXPORT SALES DEPT. IN GENOA FOR FULL DETAILS OF OUTLETS IN YOUR COUNTRY 49 MENU K ?????? ????? Controllori per l’aria condizionata Reguladores de aire acondicionado eC Edizion C Edición 3 Invensys K Indice Pagina Indice per codici articoli 5 Indice per codice ordine 5 Tabella applicazioni e regolazioni 6 Indicazioni tecniche generali 7 Controllore elettromeccanico per l’aria condizionata Serie 6000 RTR-E 6721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 RTR-E 6731 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 RTR-E 6732 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Serie 7000 KLR-E 7004 KLR-E 7006 KLR-E 7007 KLR-E 7009 KLR-E 7010 KLR-E 7011 KLR-E 7012 KLR-E 7015 KLR-E 7016 KLR-E 7017 KLR-E 7019 KLR-E 7026 KLR-E 7034 KLR-E 7037 KLR-E 7038 KLR-E 7430 KLR-E 7434 SST-E 6990 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 . . . . . . . . 10 . . . . . . . . 11 . . . . . . . . 11 . . . . . . . . 12 . . . . . . . . 12 . . . . . . . . 13 . . . . . . . . 13 . . . . . . . . 13 . . . . . . . . 14 . . . . . . . . 14 . . . . . . . . 15 . . . . . . . . 15 . . . . . . . . 27 . . . . . . . . 16 . . . . . . . . 19 . . . . . . . . 19 . . . . . . . . 27 Controllore elettronico per l’aria condizionata KLR-E 525 52 4p . . . . . . . . . . . . . . KLR-E 525 52 hp . . . . . . . . . . . . . . KLR-E 525 55 . . . . . . . . . . . . . . . . . KLR-E 525 56 . . . . . . . . . . . . . . . . KLR-E 525 58 . . . . . . . . . . . . . . . . . KLR-E 527 21 . . . . . . . . . . . . . . . . . KLR-E 527 22 . . . . . . . . . . . . . . . . . KLR-E 527 23 . . . . . . . . . . . . . . . . . KLR-E 527 24 . . . . . . . . . . . . . . . . . KLR-E 7201 . . . . . . . . . . . . . . . . . . KLR-E 7202 . . . . . . . . . . . . . . . . . . KLR-E 7203 . . . . . . . . . . . . . . . . . . KLR-E 7204 . . . . . . . . . . . . . . . . . . KLR-E 7222 . . . . . . . . . . . . . . . . . . KLR-E 7603 . . . . . . . . . . . . . . . . . . KLR-E 7611 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 . . . . . . . 21 . . . . . . . 22 . . . . . . . 22 . . . . . . . 26 . . . . . . . 23 . . . . . . . 23 . . . . . . . 25 . . . . . . . 25 . . . . . . . 16 . . . . . . . 17 . . . . . . . 17 . . . . . . . 18 . . . . . . . 18 . . . . . . . 20 . . . . . . . 20 Cronotermostato per la climatizzazione – Easy klima S 33 Gamma di Controlli modulanti con Display Digitale – KLR-E 517 7801, KLR-E 517 7805, KLR-E 517 7810 24 Regolatore elettronico per l’aria condizionata con display LCD – KLR-E 527 23 e KLR-E 527 24 25 Regolatore universale per l’aria condizionata – FC BASIC 28–29 Regolatore intelligente per l’aria condizionata con display LCD – Instat 7 30–32 Regolatore di raffreddamento a soffitto – KLR-E 525 58 26 Accessori 34–35 SGH 473 /ARA 1 E / ARA 1,7 E / ARA easy / F 190 021 / F 193 720 . . . . . . . . . . . . . . . . . . . . . . . 34 -35 Se non si è sicuri che tipo scegliere, preghiamo di fornirci le seguenti informazioni: 1. Schema elettrico e/o diagramma circuito dei termostati richiesti. 2. Funzioni richieste – numero di velocità dei ventilatori – ritardo inizio del compressore. – indicatori LED i.e. On, riscald., raffr., etc. – altre funzioni. 3. Switching load (lampade, volt, induttivo/resistivo etc.) – commutazione manuale o automatica riscald./raffr. (estate/inverno). – controllo permanente dei ventilatori o per termostato. – opzione per sonda remota. 4 K Invensys Indice Página Indice por número de artículo 5 Indice por tipo 5 Cuadro de aplicaciones 6 Información técnica general 7 Reguladores de aire acondicionado electromecánicos Serie 6000 RTR-E 6721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 RTR-E 6731 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 RTR-E 6732 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Serie 7000 KLR-E 7004 KLR-E 7006 KLR-E 7007 KLR-E 7009 KLR-E 7010 KLR-E 7011 KLR-E 7012 KLR-E 7015 KLR-E 7016 KLR-E 7017 KLR-E 7019 KLR-E 7026 KLR-E 7034 KLR-E 7037 KLR-E 7038 KLR-E 7430 KLR-E 7434 SST-E 6990 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 . . . . . . . . 10 . . . . . . . . 11 . . . . . . . . 11 . . . . . . . . 12 . . . . . . . . 12 . . . . . . . . 13 . . . . . . . . 13 . . . . . . . . 13 . . . . . . . . 14 . . . . . . . . 14 . . . . . . . . 15 . . . . . . . . 15 . . . . . . . . 27 . . . . . . . . 16 . . . . . . . . 19 . . . . . . . . 19 . . . . . . . . 27 Reguladores de aire acondicionado electrónicos KLR-E 525 52 4p . . . . . . . . . . . . . . . . KLR-E 525 52 hp . . . . . . . . . . . . . . . . KLR-E 525 55 . . . . . . . . . . . . . . . . . . . KLR-E 525 56 . . . . . . . . . . . . . . . . . . KLR-E 525 58 . . . . . . . . . . . . . . . . . . . KLR-E 527 21 . . . . . . . . . . . . . . . . . . . KLR-E 527 22 . . . . . . . . . . . . . . . . . . . KLR-E 527 23 . . . . . . . . . . . . . . . . . . . KLR-E 527 24 . . . . . . . . . . . . . . . . . . . KLR-E 7201 . . . . . . . . . . . . . . . . . . . . KLR-E 7202 . . . . . . . . . . . . . . . . . . . . KLR-E 7203 . . . . . . . . . . . . . . . . . . . . KLR-E 7204 . . . . . . . . . . . . . . . . . . . . KLR-E 7222 . . . . . . . . . . . . . . . . . . . . KLR-E 7603 . . . . . . . . . . . . . . . . . . . . KLR-E 7611 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 . . . . . . . 21 . . . . . . . 22 . . . . . . . 22 . . . . . . . 26 . . . . . . . 23 . . . . . . . 23 . . . . . . . 25 . . . . . . . 25 . . . . . . . 16 . . . . . . . 17 . . . . . . . 17 . . . . . . . 18 . . . . . . . 18 . . . . . . . 20 . . . . . . . 20 Termostato con reloj para instalaciones de aire acondicionado – Easy klima S 33 Gama de Controles Modulates con Display Digital – KLR-E 517 7801, KLR-E 517 7805, KLR-E 517 7810- 24 Reguladores de aire acondicionado electrónicos con display LCD – KLR-E 527 23 y KLR-E 527 24 25 Regulador universal de aire acondicionado (FC BASIC) 28–29 Regulador inteligente de aire acondicionado con display LCD – Instat 7 30–32 Termostato para sistemas de refrigeración de techo – KLR-E 525 58 26 Accesorios 34–35 SGH 473 /ARA 1 E / ARA 1,7 E / ARA easy / F 190 021 / F 193 720 . . . . . . . . . . . . . . . . . . . . . . . 34-35 Si tiene alguna duda sobre el tipo que seleccionar, rogamos que nos facilite las siguientes informaciones: 1. Esquema de conexiones y/o de circuitos de los controladores requeridos. 2. Funciones requeridas – numero de velocidades de ventiladores – retardo en el arranque de la compresora – indicadores LED, p.ej. ON, calef., refrig. etc. – otras funciones – conmutación manual o automática calef./refrig. (verano/invierno) – control permanente de ventiladores o vía termostato – opciones para sensor a distancia 3. Cargas de conmutación (lámparas, voltaje, inductivas/resistivas etc.) 5 Invensys K Indice Indice per numero art. por número de artículo per tipo por tipo Pagina / Página Pagina / Página 00019 3720 000 (F 193 720) 35 ARA 1 E (00763 2399 001) 34 00719 0021 000 (F 190 021) 35 ARA 1,7 E (00763 2488 001) 34 00763 2399 001 (ARA 1E) 34 ARA easy (00763 2439 000) 34 00763 2439 000 (ARA easy) 34 easy Klima-t (517 2709 51 100) 33 00763 2488 001 (ARA 1,7 E) 34 easy Klima-w (517 2710 51 100) 33 0527 31 xxx- 60xxx (INSTAT 7) 30-32 F 190 021 (00719 0021 000) 35 110 1901 90 100 (SST-E 6990) 27 F 193 720 (00019 3720 000) 35 111 1701 51 100 (RTR-E 6721) 9 FC BASIC 28-29 111 1705 51 100 (RTR-E 6731) 9 INSTAT 7 (0527 31 xxx- 60xxx) 30-32 111 1706 51 100 (RTR-E 6732) 9 KLR-E 517 7801 (517 7801 21 100) 24 111 7019 51 100 (KLR-E 7019) 14 KLR-E 517 7805 (517 7805 21 100) 24 111 7026 51 100 (KLR-E 7026) 15 KLR-E 517 7810 (517 7810 21 100) 24 111 7704 51 100 (KLR-E 7004) 10 KLR-E 525 52 4p (517 7210 51 100) 21 111 7706 51 100 (KLR-E 7006) 10 KLR-E 525 52 hp (517 7240 51 100) 21 111 7707 91 100 (KLR-E 7007) 11 KLR-E 525 55 (515 7801 21 100) 22 111 7709 51 100 (KLR-E 7009) 11 KLR-E 525 56 (515 7811 21 100) 22 111 7710 51 100 (KLR-E 7010) 12 KLR-E 525 58 (515 7230 21 100) 26 111 7711 51 100 (KLR-E 7011) 12 KLR-E 527 21 (515 7701 51 100) 23 111 7712 51 100 (KLR-E 7012) 13 KLR-E 527 22 (515 7706 51 100) 23 111 7715 51 100 (KLR-E 7015) 13 KLR-E 527 23 (517 7701 51 100) 25 111 7716 51 100 (KLR-E 7016) 13 KLR-E 527 24 (517 7706 51 100) 25 111 7717 51 100 (KLR-E 7017) 14 KLR-E 7004 (111 7704 51 100) 10 111 7730 51 100 (KLR-E 7430) 19 KLR-E 7006 (111 7706 51 100) 10 111 7734 51 100 (KLR-E 7034) 15 KLR-E 7007 (111 7707 91 100) 11 111 7737 51 102 (KLR-E 7037) 27 KLR-E 7009 (111 7709 51 100) 11 111 7738 51 100 (KLR-E 7038) 16 KLR-E 7010 (111 7710 51 100) 12 111 7754 51 100 (KLR-E 7434) 19 KLR-E 7011 (111 7711 51 100) 12 47305 1000 006 (SGH 473) 34 KLR-E 7012 (111 7712 51 100) 13 515 7230 21 100 (KLR-E 525 58) 26 KLR-E 7015 (111 7715 51 100) 13 515 7701 51 100 (KLR-E 527 21) 23 KLR-E 7016 (111 7716 51 100) 13 515 7706 51 100 (KLR-E 527 22) 23 KLR-E 7017 (111 7717 51 100) 14 515 7801 21 100 (KLR-E 525 55) 22 KLR-E 7019 (111 7019 51 100) 14 515 7811 21 100 (KLR-E 525 56) 22 KLR-E 7026 (111 7026 51 100) 15 517 2709 51 100 (easy Klima-t) 33 KLR-E 7034 (111 7734 51 100) 15 517 2710 51 100 (easy Klima-w) 33 KLR-E 7037 (111 7737 51 102) 27 517 7201 51 100 (KLR-E 7201) 16 KLR-E 7038 (111 7738 51 100) 16 517 7202 51 100 (KLR-E 7202) 17 KLR-E 7201 (517 7201 51 100) 16 517 7203 51 100 (KLR-E 7203) 17 KLR-E 7202 (517 7202 51 100) 17 517 7204 51 100 (KLR-E 7204) 18 KLR-E 7203 (517 7203 51 100) 17 517 7210 51 100 (KLR-E 525 52 4p) 21 KLR-E 7204 (517 7204 51 100) 18 517 7220 51 100 (KLR-E 7222) 18 KLR-E 7222 (517 7220 51 100) 18 517 7240 51 100 (KLR-E 525 52 hp) 21 KLR-E 7430 (111 7730 51 100) 19 517 7241 51 100 (KLR-E 7603) 20 KLR-E 7434 (111 7754 51 100) 19 517 7243 51 100 (KLR-E 7611) 20 KLR-E 7603 (517 7241 51 100) 20 517 7701 51 100 (KLR-E 527 23) 25 KLR-E 7611 (517 7243 51 100) 20 517 7706 51 100 (KLR-E 527 24) 25 RTR-E 6721 (111 1701 51 100) 9 517 7801 21 100 (KLR-E 517 7801) 24 RTR-E 6731 (111 1705 51 100) 9 517 7805 21 100 (KLR-E 517 7805) 24 RTR-E 6732 (111 1706 51 100) 10 517 7810 21 100 (KLR-E 517 7810) 24 SGH 473 (47305 1000 006) 34 SST-E 6990 (110 1901 90 100) 27 6 K Invensys Tabella applicazioni Cuadro de aplicaciones Tipo Pag. 2 tubi 4 tubi Refrigerazione Tipo Pág. 2 tubos 4 tubos Refrigeración 6721 6731 6732 7004 7006 7007 7009 7010 7011 7012 7015 7016 9 9 9 10 10 11 11 12 12 13 13 13 7017 7019 7026 7034 7037 14 14 15 15 27 7038 7201 7202 7203 7204 7222 7430 7434 7603 7611 525 52 4p 525 52 hp 525 55 525 56 527 21 527 22 527 23 527 24 525 58 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 25 25 26 SST-E 69 90 Instat 7 easy Klima-S 27 30 33 FC BASIC 28 210/L 220/W, 220/R 211/L 221/W. 221/R 410/L 420/W. 420/R U12/L U22/W, U22/R ++ ++ ++ + ++ ++ +* ++ +* + Refrigerazione + riscald. elettrico Pompa termica Refrigeración + calefacción el. Bomba de calor Sistema di ventilazione Sistemas de ventilación Applicazioni speciali otras aplicaciones ++ ++ ++ + ++ + ++ ++ + ++ + Unità climat. senza ventola reversibile Climat. sin válv. rev. ++ ++ ++ ++ ++ ++ Giardino d’inverno Invernadero ++ +* ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ + ++ ++ ++ ++ ++ + + + + + ++ + + ++ + ++ + + + + + ++ ++ Per raff. a soffitto Techo de refriger. ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ Techo calef./refrig., Bombas de circulación para calef./refrig. Risc. e raff. a soffitto pompe di circolazione per riscald./ raff. ++ ++ ++ ++ molto adatto + possibile / ++ preferentemente + posible * solo in combinazione con un termostato per tubi (p. es. RAR) / sólo en combinación con termostato para conductos (p. ej. RAR) 7 Invensys K Controllori per aria condizionata Informazioni tecniche generali 1. Montaggio Questi controllori di temperatura per ambienti, installabili in modo indipendente, sono progettati per la regolazione della temperatura solo in normali ambienti asciutti e chiusi. I controllori sono dotati di sistema di soppressione dei radiodisturbi secondo VDE 0875 o EN 55014. Le condizioni ambientali prevedono un'umidità relativa massima del 95% (senza condensa). Il punto di commutazione è più basso quando la manopola di impostazione temperatura è girata, rispetto al funzionamento automatico. Il punto esatto di commutazione si raggiunge solo dopo un periodo di climatizzazione variabile da 1 a 2 ore. di temperatura e cicli lunghi. Il ciclo corretto prevede 5-6 commutazioni all'ora. Assicurarsi che sia rispettata la polarità dei morsetti L e Load. L'inversione di questi contatti provoca un costante ritorno termico e abbassa il punto di commutazione; di conseguenza, il controllore di temperatura non fornisce sufficiente calore. 2. Collegamenti elettrici Collegare sempre il neutro della rete elettrica al morsetto appropriato. La mancanza di tale collegamento determina forti oscillazioni 4. Contatto normalmente aperto Questo contatto si chiude quando la temperatura aumenta e si apre quando la temperatura scende (per "raffreddamento"). Istruzioni di montaggio 3. Contatto normalmente chiuso Questo contatto si apre quando la temperatura aumenta e si chiude quando la temperatura scende (per "riscaldamento"). 5. Commutatore Si tratta di un commutatore con contatto di apertura e contatto di chiusura (il relativo funzionamento e descritto nei punti 3 e 4). 6. Commutatore con posizione neutra senza contatto (zona neutrale) Si tratta di un regolatore commutabile, cioè uno apre quando aumenta la temperatura, l’altro chiude. Tra entrambe posizioni finali si trova la posizione neutra senza contatto. Questa posizione neutra senza contatto provoca un livello di ritardo tra entrambe le posizioni finali. 7. Commutatore con posizione neutra con contatto Si tratta di un regolatore commutabile, cioè uno apre quando aumenta la temperatura, l’altro chiude. Tra entrambe posizioni finali si trova la posizione neutrale con contatto. Questa posizione neutrale con contatto regola poi la Reverse valve (valvola di inversione). 8. RF / Feedback termico La trasmissione del calore dalla fonte di riscaldamento al controllore attraverso l'aria dell'ambiente, richiede un certo lasso di tempo. Generalmente, quando l'elemento bimetallica del controllore di temperatura si riscalda, è già stato generato più calore di quello richiesto per la temperatura impostata. Tale aumento di temperatura non richiesto può essere evitato solo se il controllore si spegne prima che venga generato il calore in eccesso. Questo risultato si ottiene grazie a una piccola resistenza (resistenza di feedback termico) posizionata accanto all'elemento bimetallica. Non appena il controllore di temperatura richiede calore, viene applicata tensione alla resistenza per simulare una temperatura ambiente più alta di quella realmente raggiunta. 8 Invensys K Reguladores de aire acondicionado Información técnica general 1. Montaje Los controladores de temperatura ambiente están diseñados exclusivamente para el control de la temperatura ambiente en habitaciones cerradas y secas y en condiciones normales. Pueden montarse en unidad independiente y están protegidos contra las interferencias de acuerdo con la norma VDE 0875 o EN 55014. Humedad relativa admisible en habitaciones: un 95%, como máximo, sin condensación. De ajustar manualmente la temperatura, se alcanza el punto de conmutación más rápido que en modo automático. El punto de conmutación exacto no se alcanza antes de estar en funcionamiento entre una y dos horas el sistema. con la subsiguiente prolongación de los ciclos. La frecuencia de cambio de ciclo ideal es de 5 a 6 cambios por hora. Observe la polaridad correcta de los terminales L y de Carga. La confusión de estas conexiones provocará el efecto de la realimentación térmica continua, así como una modificación del punto de conmutación de modo que el controlador no será capaz de generar el suficiente calor. 5. Contacto inversor Conmutador que integra contactos normalmiento abiertos y cerrados. Para el funcionamiento , ver apartados 3 y 4. 6. Contacto inversor con posición intermedia sin contacto (neutral) Controlador que funciona como contacto inversor: abre un contacto al aumentar la temperatura y cierra el otro. Entre estos dos contactos se encuentra la posición intermedia sin contacto que funciona como escalón 3. Contacto normalmente cerrado de retardo. Contacto del controlador que abre al aumentar y cierra al bajar la temper- 7. Contacto inversor con posición intermedia contactante atura (para "calefacción"). Controlador que funciona como contacto inversor: abre un contacto 4. Contacto normalmente abierto al aumentar la temperatura y cierra Contacto del controlador que cierra el otro. Entre estos dos contactos se 2. Conexiones eléctricas Siempre conecte el conductor neu- al aumentar y abre al bajar la tem- encuentra la posición intermedia contactante que controla la válvula tro de red con el terminal previsto. peratura (para "refrigeración"). reversible. De lo contrario, se darán fluctuaciones de temperatura importantes 8. RF / Realimentación térmica Transcurre cierto tiempo hasta que Instrucciones de montaje el calor generado por la fuente de energía es transportado por el aire hasta el controlador de la temperatura. En consecuencia, hasta que la banda bimetálica del controlador se caliente lo suficientemente, se genera un nivel de calor no deseado. Este “exceso” de temperatura puede evitarse con un controlador capaz de reaccionar al tiempo debido, o sea, antes de generar más calor de lo requerido. Para ello, los controladores integran una resistencia de realimentación térmica que se encuentra cerca de la banda bimetálica y en la que se aplica una tensión en cuanto el controlador de temperatura requiera la alimentación de calor para simular una temperatura más baja que la existente, evitando de esta manera la reacción de la banda bimetálica. 9 Invensys K Controllori di temperatura per ambienti – Serie RTR-E 6000 Regulador de aire acondicionado para residencias y oficinas – Serie RTR-E 6000 RTR-E 6721 RTR-E 6731 RTR-E 6732 RTR-E 6731 / RTR-E 6732 non disponibili a magazzino – solo su richiesta no disponible en stock – suministro sobre demanda Caratteristiche Características Elegante design • Tecnologia bimetallica con feedback termico e ad alta precisione • Montaggio superficiale o direttamente su scatola da incasso con fori di fissaggio verticali o su guida DIN con fissaggio a scatto • I contatti raggruppati in modo chiaro si combinano in una morsettiera dimensionata generosamente per assicurare un'installazione facile e veloce • Colore alloggiamento: bianco (simile a RAL 9010) • Montabile su maschera di adattamento ARA 1E (v. pag. 32) Diseño elegante • Tecnología de bimetal con realimentación y alto nivel de precisión • Montaje mural o directamente en caja de distribucion con orificios de fijacion o en riel DIN mediante pinzas • Agrupacion de terminales para fácil orientación y dimensiones generosas para la instalacion rapida y sencilla • Colores de cajas: blanco puro (semejante a RAL 9010) • Limitación del rango por medio del mando de ajuste • Para montaje en adaptadores ARA 1E (ver página 32) Caratteristiche tecniche / Información técnica general RTR-E 6721 RTR-E 6731 111 1701 51 100 111 1705 51 100 da 5...30°C da 5...30°C de 5...30°C de 5...30°C 1 contatto di commutazione 1 contatto di commutazione 1 contacto inversor 1 contacto inversor 230 V AC 50/60 Hz 230 V / AC 50/60 Hz 230 V AC 50/60 Hz 230 V/ AC 50/60 Hz 10 mA - 10(4) A riscald., DC 30 W 10 mA - 10(4) A riscald., DC 30 W 10 mA - 5(2) A raffred. 10 mA - 5(2) A raffred. Corriente de conmutación 10 mA to 10(4) A calef., DC 30 W 10 mA to 10(4) A calef., DC 30 W 10 mA to 5(2) A refrigeración 10 mA to 5(2) A refrigeración Set-back di temperatura (TA) – – Corrección exceso temp. (TA) – – Isteresi ~ 0,5 K ~ 0,5 K Histéresis ~ 0.5 K ~ 0.5 K Interruttore – Riscaldamento/Raffreddamento Interruptor – Calefacción/Refrigeración Spia di segnalazione – – Lámpara de señalización – – Classe di protezione allogg. IP 30 / isolato IP 30 / isolato Clase de protección caja IP 30 / aislado IP 30 / aislado Dimensioni 75 x 75 x 25,5 mm 75 x 75 x 25,5 mm Dimensiones 75 x 75 x 25.5 mm 75 x 75 x 25.5 mm Modello/ Tipo Cod. art./ Re f e r e n c i a Intervallo di temperatura Rango de temperaturas Contatto Contacto Tensione di funzionamento Tensión de servicio Corrente di commutazione Schema elettrico / Esquema de conexiones RTR-E 6721 RTR-E 6731 RTR-E 6732 111 1706 51 100 da 5...30°C de 5...30°C 1 contatto di commutazione 1 contacto inversor 230 V AC 50/60 Hz 230 V AC 50/60 Hz 10 mA - 10(4) A riscald., DC 30 W 10 mA - 5(2) A raffred. 10 mA to 10(4) A calef., DC 30 W 10 mA to 5(2) A refrigeración – – ~ 0,5 K ~ 0.5 K Rete ON/ OFF/ Risc.-Raffred. ON / OFF / Calef.-Refriger. – – IP 30 / isolato IP 30 / aislado 75 x 75 x 25,5 mm 75 x 75 x 25.5 mm RTR-E 6732 10 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7004 KLR-E 7006 Caratteristiche/Características KLR-E 7004 KLR-E 7006 Interruttore Corrente ON/OFF Corrente ON/OFF Ventilatori veloci/medi/lenti Ventilatori veloci/medi/lenti Riscaldamento/Ventilazione/Raffreddam. Riscaldamento/Ventilazione/Raffreddamento ON/OFF ON/OFF Velocidad ventilador high/ med/low Velocidad ventilador high / med/low Calefacción/Ventilación/Refrigeración Calefacción/Ventilación/Refrigeración Compressore Riscaldamento Valvola di inversione (per riscaldamento ON) Raffreddamento Ventilatori veloci/medi/lenti Ventilatori veloci/medi/lenti Compresora Calefacción Válvula reversible (pos. ON para calefacción) Refrigeración Velocidad ventilador high / med / low Velocidad ventilador high / med / low Riscaldamento Riscaldamento Raffreddamento Raffreddamento Corrente ON/OFF Corrente ON/OFF Calefacción Calefacción Refrigeración Refrigeración ON/OFF ON/OFF Interruptores Uscite Salidas Spie di segnalazione Lámparas de señalización Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente interruttore Corriente de conmutación Contatto Contacto Intervallo di temperatura Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Codice ordine Tipo N° articolo Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 contatto di commutazione inversor 5…30 °C 5…30 °C ~0,5 K ~0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7004 KLR-E 7004 111 7704 51 100 111 7704 51 100 Schema elettrico / Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cos ϕ = 1 / 3 A cosϕ = 0,6 6 A cos ϕ = 1 / 3 A cosϕ = 0.6 contatto di commutazione inversor 5…30 °C 5…30 °C ~0,5 K ~0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7006 KLR-E 7006 111 7706 51 100 111 7706 51 100 11 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7007 KLR-E 7009 Caratteristiche/Características KLR-E 7007 KLR-E 7009 Interruttore Corrente ON/OFF Corrente ON/OFF Ventilatori veloci/medi/lenti Ventilazione continua/automatica Riscaldamento/Ventilazione/Raffreddam. ON/OFF ON/OFF Velocidad ventilador high/med/low Ventilación continua/automática Calefacción/Ventilación/Refrigeración Riscaldamento Riscaldamento Raffreddamento Raffreddamento Ventilatori veloci/medi/lenti Ventilazione Compressore Uscita interruttore Calefacción Calefacción Refrigeración Refrigeración Velocidad ventilador high/med/low Ventilación Compresora Salida interruptor Interruptores Uscite Salidas Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente interruttore Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Codice ordine Tipo N° articolo Referencia AC 24 V / AC 230 V / 50 / 60 Hz AC 24 V / AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 contatto di commutazione inversor 5…30 °C 5…30 °C ~0,5 K ~0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7007 KLR-E 7007 111 7707 91 100 111 7707 91 100 Schema elettrico / Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 contatto di commutazione inversor 5…30 °C 5…30 °C ~0,5 K ~0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7009 KLR-E 7009 111 7709 51 100 111 7709 51 100 12 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7010 KLR-E 7011 Caratteristiche/Características KLR-E 7010 KLR-E 7011 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti Riscaldamento/Raffreddamento ON / OFF Velocidad ventilador high / med / low Calefacción/Ventilación/Refrigeración Riscaldamento/Raffreddamento Ventilatori veloci/medi/lenti Rete ON/OFF Ventilatori veloci/medi/lenti AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cos ϕ = 1 / 3 A cos ϕ = 0,6 6 A cos ϕ = 1 / 3 A cos ϕ = 0,6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0,5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7010 KLR-E 7010 111 7710 51 100 111 7710 51 100 AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0,6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0,5 K bimetallica bimetal IIP 30 / isolato IP 30 / aislado KLR-E 7011 KLR-E 7011 111 7711 51 100 111 7711 51 100 Interruptores Uscite Salidas ON / OFF Velocidad ventilador high/med/low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción/Refrigeración Calefacción Velocidad ventilador high / med / low Refrigeración Velocidad ventilador high/med/low Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia Schema elettrico / Esquema de conexiones 13 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7012 KLR-E 7015 KLR-E 7016 Caratteristiche/Características KLR-E 7012 KLR-E 7015 KLR-E 7016 Interruttore Rete ON/OFF Riscaldamento/ Raffredd. Ventilatori veloci/medi/lenti ON / OFF Calefacción/Refrigeración Vel. ventilador high/med/low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Vel. ventilador low / med/high Rete ON/OFF Riscaldamento/ Raffredd. Ventilatori veloci/medi/lenti ON / OFF Calefacción/ Refrigeración Vel. ventilador high / med / low Ventilatori veloci/medi/lenti Riscald. suppl. ON/OFF Riscaldamento/ Raffredd./ OFF Ventilatori veloci/medi/lenti Calefacción adicional ON / OFF Calefacción/Refrigeración/OFF Vel. ventilador high / med / low Ventilatori veloci/medi/lenti Riscaldamento supplementare Interruptores Uscite Salidas Vel. ventilador high / med / low Vel. ventilador high / med / low Calefacción adicional Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cos ϕ = 1 / 3 A cos ϕ = 0,6 6 A cos ϕ = 1 / 3 A cos ϕ = 0,6 6 A cos ϕ = 1 / 3 A cos ϕ = 0,6 6 A cos ϕ = 1 / 3 A cos ϕ = 0.6 6 A cos ϕ = 1 / 3 A cos ϕ = 0.6 6 A cos ϕ = 1 / 3 A cos ϕ = 0.6 commutatore commutatore commutatore inversor inversor inversor 5...30 °C 5...30 °C 5...30 °C 5…30 °C 5…30 °C 5…30 °C ~ 0,5 K ~ 0,5 K ~ 0,5 K ~ 0.5 K ~ 0.5 K ~ 0.5 K bimetallica bimetallica bimetallica bimetal bimetal bimetal IP 30 / isolato IP 30 / isolato IP 30 / isolato IP 30 / aislado IP 30 / aislado IP 30 / aislado KLR-E 7015 KLR-E 7016 KLR-E 7012 KLR-E 7015 KLR-E 7016 KLR-E 7012 111 7715 51 100 111 7716 51 100 111 7712 51 100 111 7715 51 100 111 7716 51 100 111 7712 51 100 Schema elettrico / Esquema de conexiones 14 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7017 KLR-E 7019 Caratteristiche/Características KLR-E 7017 KLR-E 7019 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti Riscaldamento/Ventilare/Raffreddam. ON / OFF Velocidad ventilador high / med / low Calefacción/Ventilación/Refrigeración Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Rete ON/OFF Ventilatori veloci/medi/lenti Interruptores Uscite Salidas Entrate Entradas Spie di segnalazione Lámparas de señalización ON / OFF Velocidad ventilador high / med / low Raffreddamento Ventilatori veloci/medi/lenti Entrata set up temperatura Refrigeración Velocidad ventilador high / med / low Set up temperatura Aumento temperatura Riscaldamento Raffreddamento Rete ON/OFF Calefacción Refrigeración ON/ OFF Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Set up temperatura Aumento temperatura Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K — — bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7017 KLR-E 7017 111 7717 51 100 111 7717 51 100 Schema elettrico/ Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K 5K 5K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7019 KLR-E 7019 111 7019 51 100 111 7019 51 100 15 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7026 KLR-E 7034 Caratteristiche/Características KLR-E 7026 KLR-E 7034 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti Interruptores ON/OFF Velocidad ventilador high/med/low Uscite Raffreddamento Ventilatori veloci/medi/lenti Salidas Refrigeración Velocidad ventilador high / med / low Rete ON/OFF Ventilatori veloci/medi/lenti Riscaldamento/ Ventilazione/Raffreddamento ON / OFF Velocidad ventilador high / med / low Calefacción/Ventilación/Refrigeración Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Riscaldamento Raffreddamento Rete ON/OFF Calefacción Refrigeración ON / OFF Spie di segnalazione Lámparas de señalización Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Intervallo di tempertaura Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 di chiusura normalmente abierto 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7026 KLR-E 7026 111 7026 51 100 111 7026 51 100 Schema elettrico/ Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7034 KLR-E 7034 111 7734 51 100 111 7734 51 100 16 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7038 KLR-E 7201 Caratteristiche/Características KLR-E 7038 KLR-E 7201 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti Riscaldamento/Raffreddamento ON / OFF Velocidad ventilador high / med / low Calefacción/Refrigeración Riscaldamento Raffreddamento Riscaldamento/Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Calefacción/Refrigeración Velocidad ventilador high / med / low Riscaldamento Raffreddamento AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K — — bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7038 KLR-E 7038 111 7738 51 100 111 7738 51 100 AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 10 A cosϕ = 1 / 4 A cosϕ = 0,6 10 A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7201 KLR-E 7201 517 7201 51 100 517 7201 51 100 Interruptores Uscite Salidas Calefacción Refrigeración Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia Schema elettrico/ Esquema de conexiones 17 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7202 KLR-E 7203 Caratteristiche/Características KLR-E 7202 KLR-E 7203 Interruttore Rete ON/OFF Interruptores ON / OFF Uscite Riscaldamento Raffreddamento Interruttore Calefacción Refrigeración Salida interruptor Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Salidas Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 10 A cosϕ = 1 / 4 A cosϕ = 0,6 Corriente de conmutación 10 A cosϕ = 1 / 4 A cosϕ = 0.6 Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7202 KLR-E 7202 517 7202 51 100 517 7202 51 100 Schema elettrico/ Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7203 KLR-E 7203 517 7203 51 100 517 7203 51 100 18 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7204 KLR-E 7222 Caratteristiche/Características KLR-E 7204 KLR-E 7222 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Rete ON/OFF Raffreddamento Riscaldamento ON / OFF Refrigeración Calefacción Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7204 KLR-E 7204 517 7204 51 100 517 7204 51 100 AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7222 KLR-E 7222 517 7220 51 100 517 7220 51 100 Interruptores Uscite Salidas Spie di segnalazione Indication lamps Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia Schema elettrico/ Esquema de conexiones 19 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7430 KLR-E 7434 Caratteristiche/Características KLR-E 7430 KLR-E 7434 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti Ventilatori continui/automatici Riscaldamento/Ventilare/Raffredam. ON / O FF Velocidad ventilador high / med / low Ventilación continua/automática Calefacción/Ventilación/Refrigeración Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Compressore Calefacción Refrigeración Velocidad ventilador high / med / low Compresora Rete ON/OFF Ventilatori veloci/medi/lenti Ventilatori continui/automatici Riscaldamento/Ventilare/Raffreddamento ON / OFF Velocidad ventilador high / med / low Ventilación continua/automática Calefacción/Ventilación/Refrigeración Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Compressore Calefacción Refrigeración Velocidad ventilador high / med / low Compresora AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 6 A cosϕ = 1 / 3 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7434 KLR-E 7434 111 7754 51 100 111 7754 51 100 Interruptores Uscite Salidas Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia ~ 0,5 K ~ 0.5 K bimetallica bimetal IP 30 / isolato IP 30 / aislado KLR-E 7430 KLR-E 7430 111 7730 51 100 111 7730 51 100 Schema elettrico/ Esquema de conexiones 20 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7603 KLR-E 7611 Caratteristiche/Características KLR-E 7603 KLR-E 7611 Interruttore Interruptores Uscite Rete ON/OFF ON / OFF Compressore Compressore Valvola di inversione (per riscaldamento ON) Valvola di inversione (per risc. ON) Compresora Compresora Válv. reversible (pos. ON para calef.) Válvula reversible (pos. ON para calefacción) Salidas Dati tecnici / Datos técnicos Tensione di funzionamento Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 10 A cosϕ = 1 / 4 A cosϕ = 0,6 10 A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7603 hp KLR-E 7603 hp 517 7241 51 100 517 7241 51 100 Schema elettrico / Esquema de conexiones AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 10 A cosϕ = 1 / 4 A cosϕ = 0,6 10 A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~2 K ~2 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 7611 KLR-E 7611 517 7243 51 100 517 7243 51 100 21 Invensys K Controllori di temperatura per ambienti Regulador de aire acondicionado para residencias y oficinas KLR-E 52 5 52 4p KLR-E 52 5 52 hp Caratteristiche/Características KLR-E 525 52 4p KLR-E 525 52 hp Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Sonda a distanza Sensor a distancia Riscaldamento Raffreddamento Rete ON/OFF Calefacción Refrigeración ON / OFF Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Compressore Valvola di inversione (pos. ON per riscaldamento) Ventilatori veloci/medi/lenti Compresora Válvula reversible (pos. ON para calefacción) Velocidad ventilador high / med / low Sonda a distanza Sensor a distancia Rete ON/OFF AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 10A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5…30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~ 0,5…8 ,5 K ~ 0.5…8 .5 K NTC interno NTC interno F 193 720 o F 190 021 optional F 193 720 u opcionalmente F 190 021 KLR-E 525 52 4p KLR-E 525 52 4p 517 7210 51 100 517 7210 51 100 AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 î / ï 10A cosϕ = 1 / 4 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 î / ï 10A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore con zona neutrale inversor, con zona neutral 5…30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~ 0,5…8 ,5 K ~ 0.5…8 .5 K NTC interno NTC interno F 193 720 o F 190 021 optional F 193 720 u opcionalmente F 190 021 KLR-E 525 52 hp KLR-E 525 52 hp 517 7240 51 100 517 7240 51 100 Interruptores Uscite Salidas Entrate Entradas Spie di segnalazione Lámparas de señalización ON / OFF Dati tecnici / Datos técnicos Tensione di esercizio Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Sonda a distanza Sensor a distancia Tipo Tipo N° art. Referencia Schema elettrico / Esquema de conexiones 22 Invensys K Controllori di temperatura per ambienti con uscita analogica Regulador de aire acondicionado para residencias y oficinas con salida analógica KLR-E 525 55 KLR-E 525 56 Caratteristiche/Características KLR-E 525 55 KLR-E 525 56 Interruttore – Interruptores – Uscita proporzionale Riscaldamento 0 … 10 V DC, 3 mA Raffreddamento 0 … 10 V DC, 3 mA Salidas proporcionales Calefacción 0 … 10 V DC, 3 mA Refrigeración 0 … 10 V DC, 3 mA Rete ON/ Ventilatore/OFF Ventilatori veloci/medi/lenti ON / Ventilación/ OFF Velocidad ventilador high / med / low Riscaldamento 0 … 10 V DC, 3 mA Raffreddamento 0 … 10 V DC, 3 mA Ventilatori veloci/medi/lenti Calefacción 0 … 10 V DC, 3 mA Refrigeración 0 … 10 V DC, 3 mA Velocidad ventilador high/med/low Dati tecnici / Datos técnicos Tensione di esercizio Regler Tensión de servicio controlador Tensione di esercizio interr. ventilat. Tensión de servicio interr. ventilador Corrente di commutazione Corriente de conmutación Uscita analogica per risc. e raff. Salida proporcional calef. y refriger. Carico Carga Temperatura ambiente Rango de temperaturas Zona neutrale Zona neutral Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Sonda remoto Sensor a distancia Montaggio Montaje Tipo Tipo N° art. Referencia AC 24 V / 50 / 60 Hz (20…30 V) AC 24 V / 50 / 60 Hz (20…30 V) – – – – 0…10 V DC 0…10 V DC max. 3 mA máx. 3 mA 5...30 °C 5…30 °C ~ 0,5…7,5 K (regolabile) ~ 0,5…7,5 K (ajustable) NTC interno NTC interno IP 30 / isolato IP 30 / aislado F 193 720 o F 190 021 opzionale F 193 720 u opcionalmente F 190 021 a parete o con quadro adapter su scatola UP en pared o con adaptador en caja de distribución KLR-E 525 55 KLR-E 525 55 515 7801 21 100 515 7801 21 100 Schema elettrico/ Esquema de conexiones AC 24 V / 50 / 60 Hz AC 24 V / 50 / 60 Hz AC 24 V…240 V 50/60 Hz (20…240 V) AC 24 V…240 V 50/60 Hz (20…240 V) 6 (3) A 6 (3) A 0…10 V DC 0…10 V DC max. 3 mA máx. 3 mA 5...30 °C 5…30 °C ~ 0,5…7,5 K (regolabile) ~ 0,5…7,5 K (ajustable) NTC interno NTC interno IP 30 / isolato IP 30 / aislado F 193 720 o F 190 021 opzionale F 193 720 u opcionalmente F 190 021 a parete o con quadro adapter su scatola UP en pared o con adaptador en caja de distribución KLR-E 525 56 KLR-E 525 56 515 7811 21 100 515 7811 21 100 23 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 527 21 KLR-E 527 22 Caratteristiche/Características KLR-E 527 21 KLR-E 527 22 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Sonda a distanza Comm. riscaldamento/ raffredd. Sensor a distancia Inversor calefacción/refrigeración Ventilatori veloci/medi/lenti Riscaldamento/Off/ raffr./ventilazione Velocidad ventilador high / med / low Calefacción/Off/Refrigeración/Ventilación Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Sonda remota AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado F 193 720 o F 190 021 opzionale F 193 720 u opcionalmente F 190 021 KLR-E 527 21 KLR-E 527 21 515 7701 51 100 515 7701 51 100 AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0.6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0.6 commutatore inversor 5...30 °C 5…30 °C ~ 0,5 K ~ 0.5 K NTC interno NTC interno IP 30 / isolato IP 30 / aislado F 193 720 o F 190 021 opzionale F 193 720 u opcionalmente F 190 021 KLR-E 527 22 KLR-E 527 22 515 7706 51 100 515 7706 51 100 Interruptores Uscite Salidas Entrate Entradas Sensor a distancia Dati tecnici / Datos técnicos Tensione di esercizio Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Sonda remoto Sensor a distancia Tipo Tipo N° art. Referencia Schema elettrico/ Esquema de conexiones 24 Invensys K Gamma di Controlli modulanti con Display Digitale Gama de Controles Modulates con Display Digital KLR-E 517 7801 KLR-E 517 7805 KLR-E 517 7810 Caratteristiche/Características KLR-E 517 7801 KLR-E 517 7805 KLR-E 7810 Interruttore – Rete ON/OFF Interruptores – ON/OFF Rete ON/OFF Velocità Vent. Alta/Media/Bassa ON/OFF Velocidad Vent. Alta/Media/Baja Uscite (Controllo Proporzionale) Freddo 0…10 V DC, 3 mA Caldo 0…10 V DC, 3 mA Caldo ON/OFF (Resistenze Elettriche) Frío 0…10 V DC, 3 mA Calor 0…10 V DC, 3 mA Calor ON/OFF (Resistenzias Eléctricas) Freddo 0…10 V DC, 3 mA Caldo 0…10 V DC, 3 mA Caldo ON/OFF (Res. Elettriche) Singola Velocità Ventilatore Frío 0…10 V DC, 3 mA Calor 0…10 V DC, 3 mA Calor ON/OFF (Res. Eléctricas) Velocidad Ventilador Singula Salidas (Control Proporcional) Ingressi Entradas Freddo 0…10 V DC, 3 mA Caldo 0…10 V DC, 3 mA Caldo ON/OFF (Res. Elettriche) Velocità Vent. Alta/Media/Bassa Frío 0…10 V DC, 3 mA Calor 0…10 V DC, 3 mA Calor ON/OFF (Res. Eléctricas) Velocidad Vent. Alta/Media/Baja Sonda di Temperatura Remota Sonda di Temperatura Remota Sonda di Temperatura Remota Sonda de Temperatura Remota Sonda de Temperatura Remota Sonda de Temperatura Remota Dati tecnici / Datos técnicos Tensione d’Alimentazione Voltaje de Alimentación AC/DC 24 V 50/60 Hz AC/DC 24 V 50/60 Hz – Tensione d’Alimentazione Ventole Voltaje de Alimentación Ventiladores – AC/DC 24 V 50/60 Hz AC/DC 24 V 50/60 Hz AC/DC 24 V 50/60 Hz AC/DC 24 V 50/60 Hz AC 24…240 V / 50/60 Hz AC 24…240 V / 50/60 Hz AC 24…240 V / 50/60 Hz AC 24…240 V / 50/60 Hz Corrente di commutazione Corriente de conmutación f 6 A cosϕ = 1/3 A / cosϕ= 0,6 f 6 A cosϕ = 1/3 A / cosϕ= 0,6 f 6 A cosϕ = 1/3 A / cosϕ= 0,6 f 6 A cosϕ = 1/3 A / cosϕ= 0.6 f 6 A cosϕ = 1/3 A / cosϕ= 0.6 f 6 A cosϕ = 1/3 A / cosϕ= 0.6 Carico max 3 mA Carga max 3 mA Caldo 24 V AC/DC / 24 V 3(2)A Caldo 24 V AC/DC / 24 V 3(2)A Caldo 24 V AC/DC / 24 V 3(2)A Calor 24 V AC/DC / 24 V 3(2)A Calor 24 V AC/DC / 24 V 3(2)A Calor 24 V AC/DC / 24 V 3(2)A Intervallo di Temperatura Campo de temperatura 5…30 °C 5…30 °C 5…30 °C 5…30 °C 5…30 °C 5…30 °C Banda Proporzionale Banda Proporcional 1,5 K fissa 1.5 K fija 1,5 K fissa 1.5 K fija 1,5 K fissa 1.5 K fija Sonda di Temperatura Sonda de Temperatura NTC interna NTC interna NTC interna NTC interna NTC interna NTC interna Zona Neutra Zona Neutra 0,5…7,5 K regolabile 0.5…7.5 K ajustable 0,5…7,5 K regolabile 0.5…7.5 K ajustable 0,5…7,5 K regolabile 0.5…7.5 K ajustable Classe di protezione alloggiamento Clase de protección caja IP 30 / isolato IP 30 / aislado IP 30 / isolato IP 30 / aislado IP 30 / isolato IP 30 / aislado Sonda Remota Sonda Remota F 193 720 (vedere pag. 35) F 193 720 (vea la pág. 35) F 193 720 (vedere pag. 35) F 193 720 (vea la pág. 35) F 193 720 (vedere pag. 35) F 193 720 (vea la pág. 35) Tipo / Tipo 517 7801 517 7810 N° art. / Referencia 517 7801 21 100 517 7805 517 7805 21 100 Schema elettrico / Esquema de conexiones Applicazione/Aplicación • • • • Centrale Trattamento Aria Sistemi de Condizionamento canalizzati Unità Fan Coil – Ventole 3 velocità Unità Fan Coil – a Controllo Proporzionale • • • • Central de tratamiento aire Sistemas canalización aire acondicionado Fan-Coil Unidads – Ventilator 3 velocidades Fan-Coil Unidad – Vent. Control Proporcional 517 7810 21 100 25 Invensys K Controllori di temperatura per ambienti Regulador de aire acondicionado para residencias y oficinas KLR-E 527 23 KLR-E 527 24 Caratteristiche/Características KLR-E 527 23 KLR-E 527 24 Interruttore Rete ON/OFF Ventilatori veloci/medi/lenti ON / OFF Velocidad ventilador high / med / low Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Sonda remota Commutazione riscald./raffredd. Sensor a distancia Inversor calefacción/refrigeración Ventilatori veloci/medi/lenti Riscaldamento/Off/Raffredd./ Ventilare Velocidad ventilador high / med / low Calefacción/Off/Refrigeración/Ventilación Riscaldamento Raffreddamento Ventilatori veloci/medi/lenti Calefacción Refrigeración Velocidad ventilador high / med / low Sonda remota Interruptores Uscite Salidas Entrate Entradas Sensor a distancia Dati tecnici / Datos técnicos Tensione di esercizio Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Temperatura ambiente Rango de temperaturas Isteresi Histéresis Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Sonda remota Sensor a distancia Tipo Tipo N° art. Referencia AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz f 6 A cosϕ = 1 / U / P 3 A cosϕ = 1 / f 6 A cosϕ = 1 / U / P 3 A cosϕ = 1 / commutatore inversor 5...30 °C 5…30 °C AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 3 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 2 A cosϕ = 0,6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0,6 3 A cosϕ = 0,6 f 6 A cosϕ = 1 / 3 A cosϕ = 0,6 2 A cosϕ = 0,6 U / P 3 A cosϕ = 1 / 2 A cosϕ = 0,6 commutatore inversor 5…30 °C 5…30 °C ~ 0,5 K ~ 0,5 K ~ 0,5 K ~ 0,5 K NTC interno NTC interno NTC interno NTC interno IP 30 / isolato IP 30 / isolato IP 30 / aislado IP 30 / aislado F 193 720 o F 190 021 optional F 193 720 o F 190 021 optional F 193 720 u opcionalmente F 190 021 F 193 720 u opcionalmente F 190 021 KLR-E 527 23 KLR-E 527 24 KLR-E 527 23 KLR-E 527 24 517 7701 51 100 517 7706 51 100 517 7701 51 100 517 7706 51 100 Schema elettrico / Esquema de conexiones 26 Invensys K Controllori di raffreddamento a soffitto per ambienti / Regulador de sistemas de refrigeración de techo para residencias y oficinas KLR-E 525 58 Caratteristiche/Características KLR-E 525 58 Uscite Riscaldamento Raffreddamento Calefacción Refrigeración Condensazione Raffreddamento Riscaldamento Condensación Refrigeración Calefacción Sonda di condensazione Sensor de condensación Salidas Spie di segnalazione Lámparas de señalización Entrate Entradas Dati tecnici / Datos técnicos Tensione di esercizio Tensión de servicio Corrente di commutazione Corriente de conmutación Contatto Contacto Intervallo di temperatura Rango de temperaturas Isteresi Histéresis Zona neutrale Zona neutral Intervallo stadi Escalones Sonda temperatura Sensor de temperatura Classe di protezione alloggiamento Clase de protección caja Tipo Tipo N° art. Referencia Sonda di condensazione Sensor de condensación N° art. Referencia AC 24 V / 50 / 60 Hz AC 24 V / 50 / 60 Hz 10 A cosϕ = 1 / 4 A cosϕ = 0,6 10 A cosϕ = 1 / 4 A cosϕ = 0.6 commutatore inversor 5…30 °C 5…30 °C ~ 0,5 K ~ 0.5 K ~ 0,5…8,5 K ~ 0.5…8.5 K — — NTC interno NTC interno IP 30 / isolato IP 30 / aislado KLR-E 525 58 KLR-E 525 58 517 7230 21 100 517 7230 21 100 TS 193 683 (cavo di PVC, di 10 m) TS 193 683 (cable de PVC, de 10 m) 000 193 683 000 000 193 683 000 Schema elettrico / Esquema de conexiones 27 Invensys K Controllori di temperatura per ambienti – Serie KLR-E 7000 Regulador de aire acondicionado para residencias y oficinas – Serie KLR-E 7000 KLR-E 7037 SST-E 6990 KLR-E 7037 Controllo remoto / Estación de control remoto Per il controllo di finestre o di impianti per ombra Para el control de ventanas o sistemas de sobreado APERTO/ CHIUSO Auto/Manuale Abrir/Cerrar Auto/Manual Aperto Chiuso Abrir Cerrar Per il controllo remoto di ventilatori Tensione di esercizio Tensión de servicio Corrente di commutazione AC 230 V / 50 / 60 Hz AC 230 V / 50 / 60 Hz 6 A cosϕ = 1 / 3 A cosϕ = 0,6 Corriente de conmutación 6 A cosϕ = 1 / 3 A cosϕ = 0.6 Contatto Contacto Isteresi Histéresis Temperatura di intervallo Rango de temperaturas Sonda temperatura Sensor de temperatura Classe di protezione Clase de protección caja Tipo Tipo N° art. Referencia commutatore inversor ~3 K /~7 K ~3 K /~7 K 5...30 °C 5…30 °C bimetallico bimetal IP 30 / isolato IP 30 / aislado KLR-E 7037 KLR-E 7037 111 7737 51 102 111 7737 51 102 12…250 V ~ 12…250 V ~ on/off switch 16 (5) A Velocidad ventilador switch conmutador ON/OFF conmutador velocidad ventilador – – – – – – – – IP 30 IP 30 SST-E 6990 SST-E 6990 110 1901 90 100 110 1901 90 100 Caratteristiche/Características Interruttore Interruptores Uscite Salidas Para el control remoto de ventiladores Rete ON/OFF Ventilatori veloci/medi/lenti ON/OFF Velocidad ventilador high / med ium/ low Rete ON/OFF Ventilatori ON/OFF Velocidad ventilador Dati tecnici/ Datos técnicos Schema elettrico elettrico//Wiring Esquema diagram de conexiones 6 (3) A 16 (5) A 6 (3) A 28 Invensys K Controllore universale per Fancoils – FC BASIC Regulador universal para sistemas de ventilación – FC BASIC FC BASIC Caratteristiche: Características FC BASIC è la soluzione ideale per le installazioni che richiedono funzionalità, bassi costi e innovazione tecnologica. Il design moderno ed ergonomico, unito alle specifiche caratteristiche elettroniche fanno del FC BASIC un prodotto innovativo capace di offrire un elevato comfort Oltre a modelli specifici per i diversi tipi di installazione, FC BASIC offre modelli Universali che consentono di coprire molteplici applicazioni limitandone così il numero di prodotti nel magazzino clienti. Per gli installatori FC BASIC presenta il vantaggio della facilità di installazione ed un ridotto rischio di danneggiare il controllore durante l'installazione stessa. FC BASIC garantisce un elevato livello di comfort e una drastica riduzione nei consumi energetici grazie alle 2 speciali funzioni di »Energy Saving«. FC BASIC es la solución ideal para las instalaciones de altos requerimientos en cuanto a la funcionalidad, economicidad y tecnología. Gracias a su diseño ergonómico y las funciones electrónicas orientadas al futuro, el FC BASIC es un producto innovador que garantiza una cómodidad óptima de servicio. Los mayoristas pueden suministrar un regulador universal de aire acondicionado que reúne en sí toda la gama de aplicaciones de ventilación posibles, disminuyendo de esta manera notablemente los stocks en general. La instalación del FC BASIC se puede realizar fácilmente y con menor riesgo de destrucción por el personal de servicio durante los trabajos de montaje, y el usuario final dispone de un producto confortable que ofrece dos funciones de ahorro de energía. Además, el FC BASIC permite el control perfecto de las instalaciones de aire acondicionado en hoteles. Datos técnicos / Datos técnicos Intervallo di temperatura Rango de temperaturas Tensione di alimentazione Tensión de alimentación Corrente di commutazione Corriente de conmutación Interruttore 5…35 °C 5…35 °C 230 V AC, 50/60 Hz 230 V AC, 50/60 Hz 2 A cos ϕ = 0,4 2 A cos ϕ = 0,4 velocità del ventilatore (3 fasi) selezionatore modo di funzionamento (riscaldamento/ Off/ raffredd.) o interruttore ON/ OFF Interruptores control de la velocidad del ventilador (low / medium / high) selecionador del modo de servicio (Calefacción/ OFF / Refrigeración) o interruptor ON / OFF LED-Spie di segnalazione per riscaldamento (rosso), raffreddamento (verde), On/Economy (giallo) Indicadores LED para calefacción (rojo), refrigeración (verde), ON/Economy (amarillo) Entrate 2 entrate analogiche per sonda NTC (temperatura ambiente e acqua) Entradas 2 entradas analógicas, como máximo, para sensores NTC (temperatura ambiental y agua) Uscite 3 uscite relè Salidas 3 relés, como máximo Isteresi ~1 K o 2 K (selezionabile via DIP-switch) Histéresis ~1 K o 2 K (seleccionable vía conmutador DIP) Zona neutra ~2 K o 5 K (selezionabile via DIP-switch) Zona neutral ~2 K o 5 K (seleccionable vía conmutador DIP) Contatto SPDT Contacto inversor Connessioni (max. fili per Ø 2,5 mm) morsetti a vite Conexiones regleta de terminales roscados para hilos de Ø 2,5 mm, como máximo Colore alloggiamento pannello frontale bianco, piastra di base grigia Color caja panel frontal de color blanco, placa de base de color gris Classe di protezione alloggiamento IP 30 / isolato Clase de protección caja IP 30 / aislado Dimensioni 120 x 80 x 40 mm Dimensiones 120 x 80 x 40 mm Opzioni interruttore Eco per abbassamento temperatura, sonda a distanza e di temperatura acqua sonda NTC 6 x 40 1,5 m cappuccio metallico, sonda NTC 103AT-2 1.5 m cappuccio plastico (lung. varie) Opciones conmutador “Economy” para corrección de exceso de temp., sensor a distancia y de temp. agua sensor NTC 6 x 40 1,5 m, tapa metal; sensor NTC 103AT-2 de 1,5 m, tapa plástico (varias long.) 29 K Controllore di temperatura elettronico per Fancoils (2 e 4 impianti tubo) Reguladores electrónicos para Fancoils (sistemas de 2 y 4 tubos) Entrate / Intputs Interr. / Interr. Functions ■ ■ ■ ■ U12/L U22/W U22/R ■ ■ ■ ■ ■ ■ ■ ■ ■ FB60R0000200 FB80R0000200 FB40R0000200 ■ 420/W 420/R FB80W0000200 FB40W0000200 ■ 410/L Universale (tutte applicazioni) Universal (todas las aplicaciones) FB70L0000200 FB20L0000200 221/W 221/R FB30R0000200 211/L Uscite / Salidas Codice articolo Referencia Ventola riscald. o raffr. Válvula calef. o refrig. Riscaldamento elettrico Calefacción eléctrica Ventola riscald. e raffr. Válvula calef. o refrig. Velocità ventilatore Velocidad ventilador Sonda remota (aria) Sensor a distancia aire Entrata per sonda acqua Entrada sensor agua Entrata contatto finestra Entrada contacto ventana Sonda remota riscald./raff. Entrada calefac./refr. dist. 3 Velocità ventilatore Ventilador 3 velocidades On/Off On/Off Riscald./OFF/Raffredd. Calefac./OFF/Refrig. Eco-Interruttore* Conmutador Economy* Commutazione automatica Conmutador automático Commutazione manuale Conmutador manual Apertura valvole periodica Abertura válvula periodica Antigelo Anti-congelación Avviamento a caldo (timer) Arranque caliente (timer) Avviamento a caldo (temp) Arranque caliente (temp.) Ventilazione periodica Ventilación periodica Protezione valvola Protección válvula Limite di set point Limitación del rango LED (Riscald./Raffr./ON) LED (calefac./refrig./ON) 220/W 220/R FB30W0000200 210/L FB10L0000200 Modell o/ Modelo fan coils 4-tubi Fancoil de 4 tubos fan coils 2-tubi + Risc. elettr. Fancoil 2 tubos + calef. eléctrica FB60W0000200 fan coils 2-tubi Fancoil de 2 tubos FB50L0000200 Invensys ■ ■ ■ ■ ■ ■ 3 3 3 3 3 3 3 3 3 3 3 3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ * Tutti i modelli possono essere consegnati con Eco-Interruttore, il 4° posto del codice articolo cambia da „0“ a „E“. * Se pueden suministrar todos los modelos con conmutador “Economy”. Cambie la posición nº 4 de la referencia de ”0“ a ”E“. Schema elettrico / Esquema de conexiones N N 1 2 3 4 5 Air FAN L H2 O L 13 14 15 16 17 18 19 OUT 1 OUT 2 sólo 2 tubos OUT 1 fuera de servicio OUT 2 calef./refrg. válvula solo 2 tubi OUT 1 fuori servizio OUT 2 riscald./raffr. valvola 2 tubos, con calef. eléctrica OUT 1 calef./refrg. válvula OUT 2 calef. eléctrica 2 tubi, con riscald. elettrico OUT 1 riscald./raffr. valvola OUT 2 riscald. elettrico 4 tubos OUT 1 válvula refrigeración OUT 2 válvula calefacción 4 tubi OUT 1 valvola raffreddamento OUT 2 valvola riscaldamento 1 Veloce High speed 2 Medio Med. Speed 3 Lento Low Speed 4 Fase Fase 5 Neutro Neutro 13-15 Uscite relè Salidas relé 16-17 Sonda acqua Sonda remota Riscald./Raffr. Contatto finestra Sensor agua Calefac./refrig./contacto ventana a distancia 18-19 Sonda remota (aria) Sensor aire ST3 ST2 30 Invensys K Controllori di temperatura elettronici Instat 7 Regulador electrónico de aire acondicionado Instat 7 Instat 7 Campi di applicazione: Aplicaciones • • • • • • • • Convettori a ventilazione 2-tubi/4-tubi (fan coils) Pompe di riscaldamento (valvola di inversione) Climatizzazione reversibile Aria condizionata con/senza riscaldamento elettrico Fancoils de 2/4 tubos Bombas de calor (válvula reversible) Sistemas de climatización reversible Equipos de aire acondicionado con o sin calefacción eléctrica Caratteristiche: Características • Regolatore ON/OFF • Spia LCD chiara con spia contemporanea di temperatura ambiente, funzione e scelta ventilazione • Spia permanente della temperatura reale • Attuatori: 4 tasti (Mode/+/-/OK) • Comando per menu • Max. 5 uscite relè • Stand By (attesa) • Commutare automatics tra riscald. e raffr. • Zone neutre regolabili • Comando ventilazione man. in 3 fasi • Ventilazione automatica (utilizzabile per riscaldamento e raffreddamento, 3 numero giri in dipendenza di differenza di temperatura) • Ritardo compressore in caso di mancanza di tensione un esercizio e in commutazione di funzione • Tempo di utilizzazione ventilazione (in riscaldam OFF): 1 min. • Commutazione automatica tra sonda temperatura interna e esterna • Sicurezza dei dati durevole dopo perdita di corrente • Control ON/OFF • LCD de grandes dimensiones para la visualización de temperatura, modo de servicio y selección de ventilador • Visualización continua de la temperatura actual • 4 teclas de servicio (Mode/+/-/OK) • Guía de menús • 5 salidas de relés, como máximo • Función “Stand-by” • Cambio automático entre calefacción/refrigeración • Zona neutral ajustable • Control manual de ventiladores, 3 velocidades • Ventilación automática (ventilación en modos calefacción y refrigeración, 3 velocidades en función de la diferencia de temperatura) • Retardo de compresión en caso de rearranque, servicio normal y cambio de funciones • Marcha en inercia del ventilador: 1 minuto (calefacción OFF) • Cambio automáticico entre sensor de temperatura interno y externo • Memorización de datos continua en caso de fallar la alimentación de red Opzioni: • 2 x riscald. e 2 x raffr. (zona neutra regolabile) • Uscita per valvola di inversione • Funzione disgelo • elettr. riscaldamento supplementare per pompe di riscald. • Regolazione esterna in funzionamento a freddo • Sonda remota • Contatto finestra • Air-Sweep On/Off • ON-Timer, OFF-Timer (regolabile: 10 min. fino a 99 h 50 min.) • funzione Master/Slave (spegnere slaves, se master spento) • Hotel Version • Interruttore On/Off (arresto unipolare della tensione rete) • Tensione di esercizio AC 230 V o AC 24 V Opciones • • • • • • • • • • • 2 escalones de calefacción y refrigeración, resp. (ajustables) Salida de válvula reversible Función anti-congelación Calefacción eléctrica adicional para bombas de calor Control de temperatura externa en servicio de refrigeración Sensor a distancia • Contacto de ventana • Air sweep ON/OFF Timer ON/OFF (de 10 min a 99h 50 min) Función maestro-esclavo Versión para hoteles (limitada en funciones) Interruptor ON/OFF Tensión de servicio opcionalmente AC 230 V o AC 24 V Schema elettrico/ Esquema de conexiones Instat 7 527 31 – per 4-tubi Fancoils Instat 7 527 31 – para Fancoils de 4 tubos Instat 7 527 49 – per 2-tubi Fancoils Instat 7 527 49 – para Fancoils de 2 tubos Instat 7 527 55 – per pompa risc. c. valvola di inversione Instat 7 527 55 – para bomba de calor con válvula revers. 31 Invensys K Controllore di temperatura elettronico Instat 7 Regulador electrónico de aire acondicionado Instat 7 Datos técnicos / Datos técnicos Display temperatura richiesta Indicación temperatura ajustada 15…30 °C (risoluzione 0,5 K) 15…30 °C (resolución 0,5 K) Display temperatura reale Indicación temperatura actual 0...40 °C (risoluzione 0,1 K) 0…40 °C (resolución 0,1 K) Tensione di esercizio Tensión de servicio AC 230 V 50 Hz, AC 24 V AC 230 V 50 Hz, AC 24 V Consumo di energia Consumo de energía _ < 8 VA _ < 8 VA Display Display LCD-Display con contemporaneo display temperatura ambiente, funzione e selezione vent. LCD, indicación de la temperatura ambiental, modo de servicio y selección de ventilador Temperatura di esercizio Temperatura de servicio 0...40 °C 0…40 °C Temperatura ambiente Temperatura de almacenamiento –20...70 °C –20…70 °C Modo di regolazione Modo de regulación ON/OFF ON/OFF Intervallo di misurazione Intervalos de medición 15...45 sec. 15…45 sec. Timer 10 min fino a 99 h. 50 min – risoluzione 1min, precisione < 1 min/giorno(a 20 °C) risoluzione tempo di commutazione 10 min de 10min a 99 h 50 min; resolución: 1 min, precisión: < 1 min/día (a 20 °C); resolución tiempo de conmuatción: 10 min Timer Relè (max 5 pezzi a seconda variante) Relés (según versión, hasta 5 unidades) 5 A (cosϕ = 1, AC 250 V) / 2 A (cosϕ = 0,6, AC 250 V) max. corrente per collegamento L: < _ 10 A 5 A (cosϕ = 1, AC 250 V) / 2 A (cosϕ = 0,6, AC 250 V) corriente máxima por terminal L: < _ 10 A Isteresi Histéresis per riscaldamento: 1,1 K calefacción: 1,1 K Zona Zona Zona Zona Zona Zona neutrale „Riscaldamento/Raffreddamento“ neutrale „Riscaldamento 1/Riscaldamento 2“ neutrale „Raffreddamento 1/Raffreddamento 2“ neutral “Calefacción/Refrigeración” neutral “Calefacción 1/Calefacción 2” neutral “Refrigeración 1/Refrigeración 2” per raffreddamento: 1,3 K refrigeración: 1,3 K 0 K…5 K 0 K…5 K 0 K…5 K 0 K…5 K 0 K…5 K 0 K…5 K (risoluzione 0,5 K) regolabile (risoluzione 0,5 K) regolabile (risoluzione 0,5 K) regolabile (resolución: 0,5 K) ajustable (resolución: 0,5 K) ajustable (resolución: 0,5 K) ajustable Ritardo compressore Retardo compresora ~ 4 min ~ 4 min Ritardo ventilatore Retardo ventilador ~ 1 min ~ 1 min Contatto finestra Contacto ventana usare solo contatto per classe protezione II (AC 230 V), con finestra aperta contatto chiuso sólo contactos de clase de protección II (AC 230 V), cierre de contact con ventana abierta Classe protezione alloggiamento Clase de protección caja IP 40 IP 40 Protezione umidità Protección contra humedad senza condensa sin condensación Montaggio Montaje montaggio a parete o direttamente su scatola UP a incastro en pared o caja de distribución Temperatura sonda Sensor de temperatura NTC (in alloggiamento) NTC (integrado en la caja) Sonda remoto (opzionale) Sensor a distancia (opción) Tipo F 193 720, possibile estensione fino max. 10 m Tipo F 193 720, prolongación de hasta 10 m, como máximo Colore alloggiamento Color de caja bianco puro, simile RAL 9010 blanco puro, semejante a RAL 9010 Peso Peso 175 g 175 g Nr. articolo. Referencia vedi matrice delle varianti nella pagina successiva ver cuadro de aplicaciones en página 31 32 Invensys K Controllore di temperatura elettronico Instat 7 Regulador electrónico de aire acondicionado Instat 7 Matrix varianti 2-tubi Fan Coils 0527 40 0527 41 0527 42 0527 43 0527 44 0527 45 0527 46 0527 47 0527 48 0527 49 0527 50 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 3 3 2 2 ■ ■ 3 3 3 3 3 3 1 1 3 2 1 1 1 1 3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 3 3 2 2 3 2 2 3 2 3 ■ ■ 1 1 ■ ■ ■ ■ ■ ■ ■ P ■ ■ ■ ■ ■ O 1 ■ ■ ■ 3 0527 60 0527 39 1 1 0527 59 0527 38 1 1 0527 58 0527 37 1 1 0527 57 0527 36 1 1 0527 54 0527 35 1 1 0527 53 0527 34 1 1 0527 52 0527 33 1 1 0527 51 0527 32 T ■ ■ ■ ■ ■ ■ ■ I O N A L ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 0527 60 Riscald. (livello) Raffr. (livello) Compressore Valvola di inver. Livelli ventilatore Air sweep Risc. suppl. Ventilazione ester. Versione Hotel1) Timer On/Off Manuale Riscald./raffredd. solo ventilatore/ solo raffr. Interrut. On/Off Commutazione Riscald./raffredd. Contatto finestra Master/Slave Sonda ambiente Defrost Sonda esterna L 0527 59 Sonda remoto Entrate Funzioni Uscita relè Tipo ordine Variante Instat 7 L 0527 31 L Per pompe di riscaldamento 0527 56 2 x riscald. 2 x raffr. 0527 55 solo raffr. per 4-tubi Fan Coils ■ „L“ = in magazzino. Tute le altre varianti a richiesta! Tutti e 3 gli apparecchi a magazzino funzionano a scelta con sonda remota tipo F 193 720 . 1) Le funzioni „solo riscaldamento, „solo raffreddamento“ e „solo ventilazione“ non sono possibili con la „versione Hotel“. sólo 2 x calefacción Fancoils refrig. 2 x refrigeración 2 tubos Remote sensor Entradas Functions Relay salidas 0527 40 0527 41 0527 42 0527 43 0527 44 0527 45 0527 46 0527 47 0527 48 0527 49 0527 50 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 3 3 2 2 ■ ■ 3 3 3 3 3 3 1 1 3 2 1 1 1 1 3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 3 3 2 2 3 2 2 3 2 3 ■ ■ 1 1 ■ ■ ■ ■ ■ ■ ■ P ■ ■ ■ ■ ■ O 1 ■ ■ ■ 3 0527 58 0527 39 1 1 0527 57 0527 38 1 1 0527 56 0527 37 1 1 0527 54 0527 36 1 1 0527 53 0527 35 1 1 0527 52 0527 34 1 1 0527 51 0527 33 L 0527 32 Calefacción (escal.) Refrig. (escal.) Compresora Válvula reversible Veloc. ventilador Air sweep Calefacción adic. Ventilador externo Versión ‘Hotel’ Timer ON/OFF Calef./Refriger. manual Sólo ventilación/ Sólo refrigeración Interr. ON/OFF Conmutación calef./refriger. Contacto ventana Maestro/esclavo Sensor ambiente Anti-congelación Sensor externo L 0527 31 L Para bombas de calor 0527 55 Para Fancoils de 4 tubos T ■ ■ ■ ■ ■ ■ ■ I O N A L ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ‘L’ = en almacén. Otras variantes sobre demanda. 1) Las funciones ”Sólo calefacción“ y ”Sólo ventilación“ no están disponibles para la versión ”Hotel“. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 33 Invensys K Cronotermostato elettronico per la climatizzazione Termostato con reloj electrónico para sistemas de aire acondicionado easy klima-S Schema elettrico/ Esquema de conexiones Caratteristiche: Características • facile funzionamento • commutazione caldo freddo tramite interruttore • con caduta o aumento di temperatura (eco) • 3 modalità di funzionamento per: temperatura continua comfort, temperatura continua „eco“, timer (automatico) • spie di segnalazione per display richiesta energia, esercizio „eco“ • disponibile con orologio di programmazione giornaliera o settimanale • sonda remota collegabile (con controllo sonda) • entrata poss. per comm. telefonica • tensione di esercizio 230 V, possibile variante 24 V • modulazione durata impulsi (PWM) o On/Off • varianti con commutazione H/K per morsetto collegamento su richiesta • Manejo sencillo • Conmutador calef./refrig. • Bajar y aumentar temperatura (eco) • 3 modos de servicio selecionables: temp. agradable permanente, temp. económica permanente, modo Timer (servicio automático) • Lámparas de señalización para: requerimiento de energía, modo económico • Timer de 24 horas o 7 días • Terminal para sensor a distancia (con control de rotura de sensor) • Opcionalmente conmutador a distancia vía línea telefónica • Tensión de servicio: 230 V, opcionalmente: 24 V • Característica de control: modulación de duración impulsos o ON/OFF • Versión con conmutación calef./refrig. vía terminal sobre demanda Dati tecnici generali / Información técnica general No. ordine/Tipo / Ref./tipo easy klima-S t (oro. giornaliero / día) Tensione di alimentazione Tensión de alimentación Ambito intervallo di temperatura: temperatura ambiente temperatura „eco“ Rango de ajuste de temperaturas: temperatura ambiental temperatura ‘eco’ Interruttore Interruptor Spia di segnalazione rossa/verde Lámpara de señalización rojo/verde Caratteristica controllore Durata ciclo Característica de control Duración de ciclos Sonda temperatura Sonda remota optional easy Klima-S w (oro. settimanale / semana) 230 V AC (195…253 V) 50/60 Hz; 24 V AC (20 … 30 V) (come variante) 230 V AC (195…253 V) 50/60 Hz; 24 V AC (20 … 30 V) (opcionalmente) 5 a 0 °C 5 a 30 °C (aumento/abbassamento, regolazione sotto il coperchio) 5…30 °C 5…30 °C (aumento/disminución, mando de ajuste debajo de la tapa) comfort / automatico/ Eco (regolazione sotto il coperchio) e riscald./raffredd./ Off comfort/auto/eco (mando de ajuste debajo de la tapa), calefacción/refrigeración/ off controllore richiede raffreddamento / funzionamento „eco“ suministro de energía / modo ‘eco’ controllore proporzionale (quasi continuamento dovuto a PWM) o On/Off selezionabile regolabile, 10 o 25 minuti (somma del tempo On/Off di PWM) controlador proporcional (cuasi continuo por mod. duración de impulsos) o ON/OFF selec. ajustable entre 10 o 25 minutos (suma de tiempos ON/OFF de mod. duración de impulsos) interna F 193 720 / F 193 021, a 50 m allungabile; riconoscimento di guasti sonda; in caso di difetto della sonda remota (rottura/corto ciurcuito): in PWM 30 % riscaldamento, per relè On/Off Sensor de temperatura interno Opcionalmente sensor a distancia F 193 720 / F 193 021, prolongación hasta 50 m; detección de fallo de sensor Uscita relè, 1x commutatore, senza volt Corrente di commutazione 10 mA…10 A cosϕ = 1; max. 4 A cosϕ = 0,6; max. 10 attuatori termici Tensione modo 24…250 V AC Salida Relay, 1 x change over, volt free Corriente de conmutación 10 mA…10 A cosϕ = 1; max. 4 A cosϕ = 0.6; 10 actuadores termo-eléctricos, como máximo Tensión de conmutación 24…250 V AC Telefono remoto optional entrata per 230 V AC (comm. su temperatura giornaliera per apparecchio esterno) Opcion conmutador distancia/teléf. entrada de 230 V AC (vía dispositivo externo, se activa temperatura agradable) Limite ambito in pomello di regolazione Limitación rango de ajuste vía mando de ajuste Orologio di precisione/ riserva marca < 10 min / anno / ~ 100 h regol. tempo di comm. ogni 15 min. con orologio giornaliero; ogni 1 h con orologio settimanale Timer Precisión/reserva <10min/año / ~ 100 h Ajuste hora conmutación cada 15 min, timer de 24 h; una vez la hora, timer de 7 días Dimensioni / Dimensiones 160 x 80 x 36 mm N° articolo./Referencia 517 2709 51 100 517 2710 51 100 34 Invensys K Accessori Accesorios Alloggiamento di protezione a muro / Caja de protección Con ferritoie per la ventilazione, chiudibile, per montaggio in uffici, edifici pubblici, etc. SGH 473 Montaje en pared, cerradura, con rejillas de ventilación para el montaje de controladores en oficinas, talleres etc. Numero ordine / Tipo N° art./Referencia SGH 473 47305 1000 006 Dimensioni esterne: Dimensiones exteriores: Dimensioni interne: Dimensiones interiores: 194 194 160 160 x x x x 120 x 85 mm 120 x 85 mm 92 mm 92 mm Quadro adapter in materiale plastico / Marcos de adaptador de plástico • Per il montaggio di controllori su quasi tutte le scato- • Para el montaje de controladores en casi todos los tipos de le UP usate a livello internazionale cajas de distribución • Per coprire tutte le scatole UP non ben intonacate • Para tapar cajas de distribución no completamente integrapiù grandi della base del controllore das en pared y para cajas de distribución de dimensiones superiores a las de la placa de base del controlador ARA 1 E Numero ordine / Tipo N° art./Referencia ARA 1 E 00763 2399 001 ARA 1 E da utilizzare per: + set viti más juego de tornillos RTR-E 3000 / RTR-E 6000 / INSTAT 6-r1/ HYG-E 6001 / INSTAT 6-a1A/a1mA / FR-E 52531 DRe-E 517 18 RTR-E 3000 / RTR-E 6000 / INSTAT 6-r1/ HYG-E 6001 / INSTAT 6-a1A/a1mA / FR-E 52531 DRe-E 517 18 SS 001 (N° art. 007 10 3188 001) SS 001 (referencia 007 10 3188 001) Numero ordine / Nº de pedido N° art./Referencia ARA 1,7 E 00763 2488 001 ARA 1.7 E da utilizzare per: ARA 1.7 E para el uso con: + set viti más juego de tornillos HYG-E 7001 / RTR-E 7000 HYG-E 7001 / RTR-E 7000 SS 001 (N° art. 007 10 3188 001) SS 001 (referencia 007 10 3188 001) Numero ordine / Nº de pedido N° art./Referencia ARA easy 00763 2439 000 ARA easy da utilizzare per: ARA easy para el uso con: + set viti más juego de tornillos easy 3 cronotermostati termostato con reloj tipo easy 3 SS 003 (N° art. 007 10 3188 003) SS 003 (referencia 007 10 3188 003) ARA 1 E para el uso con: ARA 1,7 E ARA easy 35 Invensys K Accessori Accesorios Sonda remoto/Sensor a distancia F 190 021 Numero ordine / Tipo N° art./Referencia F 190 021 007 190 021 000 Dimensioni: Dimensiones: Classe protezione: Clase de protección: 75 x 75 x 25,5 mm 75 x 75 x 25.5 mm IP 30 IP 30 Numero ordine / Tipo N° art./Referencia F 193 720 000 193 720 000 Classe protezione: Clase de protección: Temperatura ambiente: Temperatura ambiental: IP 67 IP 67 –25 … 70°C –25 … 70°C Sonda remoto/Sensor a distancia F 193 720 Dimensioni: Dimensiones: Cavo sonda /Cable de sensor Il cavo della sonda può essere allungato fino a 50 m se posato con un cavo a doppio conduttore, con una sezione di1,5 mm2, posata per tensione rete, (10 m in caso Instat 6 / Instat 8). Si deve utilizzare un cavo schermato nella posa di canali per cavi o nelle vicinanze di cavi di alimentazione. Es posible prolongar hasta un máximo de 50 metros de longitud el cable del sensor por medio de un cable de dos hilos con diámetro de 1,5 m2, apto para la tensión de red (para Instat 6/Instat 8: 10 metros). Utilícese cables apantallados para la colocación en canales de cables o cerca de cables de alta tensión. Sonda per FC BASIC / Sensores para FC BASIC Dimensioni / Dimensiones de controladores de aire acondicionado tipo KLR-E y RTR-E