Technical data: from 1,6 KWe to 10 KWe Continuous power duty C.O.P; 220/400 V, 50 Hz
Design
°C / %
25 / 60
Comb. air temperature / rel. Humidity:
Altitude S.L.M. :
Operating Temperature Range :
NOx Emission (tolerance - 8%):
mt.
°C
mg/Nm3 @ 5% O2
CO2 Emission (tolerance - 8%):
mg/Nm3 @ 5% O2
1000
100
5 to 35
3 Way Dry Catalist
80
1000
3 Way Dry Catalist
80
Fuel Gas Data
Methane number:
Lower calorific value:
Standard gas:
[-]
KWh/Nm3
Natural Gas MN=
80,00
10,17
80,00
Kg/Nm3
0,79
Gas density:
C.H.P. Data
Modello/Model
entalpica
Motore/engine
entalpica
Alternatore/ generator
Temperatura di progetto / Operating temperature
range
Classificazione dell’area / Area Classification
Potenza / Power (C.O.P.) (ISO8528 e ISO3046) at
generator terminal at power factor 0,8
Potenza / Power (C.O.P.) (ISO8528 e ISO3046) at
generator terminal at power factor 1,0 :
Sovraccarico/ Overload
Power factor:
Frequenza / Frequency
Velocità /Speed
Tensione (trifase) / Voltage
Variazione tensione da 0% a pieno carico in cond. statiche
p.f. 0,8
Variazione della frequenza da 0% a pieno carico in cond.
statiche:
Peso totale (+/-10%) – Preliminare / Weight
Dimensioni generali del gruppo in container (+/-10%)
Preliminary general overall dimensions (+/-10%)
Noise level
GEZF2-NG
EEZF2-NG
GEZF4-NG
GEZF8-NG
GEZF10-NG
EEZF4-NG
EEZF8-NG
EEZF10-NG
Meccalte/Leroy Somer / Marelli
°C
GEZF12-NG
EEZF12-NG
From 0 to 35
Sicura / Safe
KVA
2,0
4,0
8,0
10,0
12,5
KVA
1,6
3,2
6,4
8,0
10,0
Hz
rpm
V
%
non ammesso / not allowed
0,8
50
3000/1500
220/400
+/- 1,5%
%
+/- 1,5%
Kg
mm
350
400
450
1200 h x 1200 w x 1200
dB(A)
500
700
1500 h x 1200 w x 2000 l
55 @ 7 mt
Energy Balance
Potenza Elettrica / Electrical Power
Potenza Termica acqua motore /J/W Thermal Power
Potenza Termica Intercooler / Intercooler Thermal Power
Potenza Termica Olio motore / Lube Oil Thermal Power
Potenza Termica gas di scarico raffreddati a 120°C
Potenza termica irraggiata / Total Radiation heat
Potenza Termica Totale (escluso Intecooler) /
KWe
KWt
1,6
1,3
KWt
KWt
KWt/
2,7
0,13
4,0
3,2
2,6
6,4
8,0
5,2
6,5
n.a.
Incorporato nel sistema acqua motore
5,4
10,8
13,5
0,26
0,51
0,64
8,0
16,0
20
10,0
8,1
17,0
0,8
25,0
ENTALPICA S.P.A
SEDE LEGALE: VIA LISSONI , 5 – 20900 MONZA (MB) - SEDE OPERATIVA : VIA SAN ROCCO N.65 , 20874 BUSNAGO (MB)
C.F. E P.IVA IT06955390965 - R.E.A. - MB - 1868865
CAPITALE SOCIALE € 1.000.000,00 I.V.
www.entalpica.eu
[email protected]
Total Thermal Power
Potenza Frigorifera /
Cold Power
Energia introdotta / Fuel Consuption
Rendimento Totale (el. + term.) / Total Efficency
Rendimento Elettrico / Electrical Efficency
Rendimento Termico acqua motore / Thermal Efficency
Rendimento Termico gas di scarico/ Thermal Efficency
Kcal
KWf/
Kcal
KW
%
%
%
%
Portata acqua motore / Jachet Water Volume Flow
Portata olio lubrificante / Lube Oil volume Flow
Portata acqua Intercooler / Intercooler Volume flow
m3/h
m3/h
m3/h
Glycol content engine jacket water / intercooler
% Vol.
3.440
2,8/
2.408
6,4
87,5
25,0
20,3
42,2
6.880
5,6/
4.816
12,8
87,5
25,0
20,3
42,2
13.760
11,2/
9.632
25,6
87,5
25,0
20,3
42,2
17.200
14/
12.040
32
87,5
25,0
20,3
42,2
21.500
17,5/
15.050
40
87,5
25,0
20,3
42,2
System Parameters
0,6
0,6
0,8
1,0
Incorporato nel sistema acqua motore / integrate with J/W
N.A.
35
1,0
Water volume engine jacket / intercooler
dm3
1/0
1,5/0
2/0
3/0
4/0
Water pressure loss engine jacket water / intercooler:
Temp. esercizio acqua motore / j/w Temperature
Temp. esercizio Olio / Lube oil Temperature
Temp. esercizio intercooler / Intercooler temperature
Temp. esercizio Freddo / Cold Power Oper. Temp. Range
Temp. Gas di scarico / Exhaust Gas temperature
Portata gas di scarico / Exhaust Gas Volume Flow
Portata aria di combustion / Combustion air volume Flow
Ventilation air flow(comb. air incl.) with ΔT = 15K
Bar
0,2/0,15
0,3/0,2
0,4/0,3
0,5/0,4
0,6/0,5
°C
°C
°C
°C
°C
Kg/h
Kg/h
Kg/h
Exhaust back pressure from / to
mBar
Maximum pressure loss in front of air cleaner
mBar
5
Zero-pressure gas control unit selectable from / to
mBar
10/100
Bar
0,5/10
Pre-pressure gas control unit selectable from / to
dm3
Ah
kWe/[
VDC
Lube oil content engine / external lube oil tank
Starter battery 12/24V, capacity required
Starter motor
80/90
Incorporato nel sistema acqua motore / integrate with J/W
N.A.
7/12
457
455
414
423
3.257
4.312
6.407
8.422
3.152
4.172
6.200
8.155
500
800
800
800
30/50
440
2.159
2.089
500
3/30
6/30
9/30
12/50
15/50
10
0,5/12
10
0,5/12
15
0,5/12
20
1/24
20
1/24
Engine data / Dati Motore
N° Cilindri / Configurazione / Configuration / Number
of cylinders:
Alesaggio x Corsa / Bore and Stroke
Cilindrata
/Displacement
Air Ratio
mm
dm3
1 wankel
2 wankel
3 wankel
5 wankel
6 wankel
0,5
0,6
0,8
1,0
1,2
1
Rotazione / rotation
Rapporto di compressione : compression ratio
Velocità media del pistone / Mean Piston speed
Pressione Media Effettiva
/ P.M.E.
Combustibile / Fueled by
m/s
MPa
-
1,72 MPa
Antioraria lato volano / A.C.W.
13 : 1
6,3
1,79 MPa
1,93 MPa
18,6 Bar
Gas Metano
18,1 Bar
Noise level Octave band
Frequency band f [Hz]
25
31,5
40
50
63
80
100
125
160
200
250
315
400
500
630
Air-borne noise 4)LW ,Terz
[dB(lin)]
Exhaust noise 5) LW ,Octave
84
85
90
93
106
101
114
102
103
112
108
111
106
105
103
-
[dB(lin)]
Frequency band f [Hz]
Air-borne noise 4) LW ,Terz
[dB(lin)]
Exhaust noise 5) LW ,Octave
[dB(lin)]
4) DIN EN ISO 3746
119
129
135
130
800
1k
1.25
k
1.6
k
2k
2.5
k
3.15
k
4k
5k
6.3
k
8k
10k
LWA
[dB(A
)]
102
103
103
102
103
103
102
105
106
109
105
103
117
83
134
15,2
128
129
5) DIN 45635-11 Appendix A (±3 dB)
123
116
S
[m2]
LW: Sound power level
ENTALPICA S.P.A
SEDE LEGALE: VIA LISSONI , 5 – 20900 MONZA (MB) - SEDE OPERATIVA : VIA SAN ROCCO N.65 , 20874 BUSNAGO (MB)
C.F. E P.IVA IT06955390965 - R.E.A. - MB - 1868865
CAPITALE SOCIALE € 1.000.000,00 I.V.
www.entalpica.eu
[email protected]
Scarica