Pagina 2: Pianta Cancello Roof (Ingresso Scale) Pagina 3: Disegno

Allegato B
Pagina 2:
Pianta Cancello Roof (Ingresso Scale)
Pagina 3:
Disegno Cancello Roof
Pagina 4:
Pianta Cancellata Roof (Piano Superiore)
Pagina 5:
Disegno Cancellata Roof
Pagina 6:
Pianta Accesso AB1
Pagina 7:
Disegno Cancello scorrevole AB1 (accesso interno)
Pagina 8:
Pianta Accesso AB2
Pagina 9:
Disegno Cancello scorrevole AB2 (accesso interno)
ES GENERAL
ACCESS AREA
m² (din care 28.2 m² chepeng-uri acces subsol tehnic)
105
100
15
100
15
H: 2,2 m
H: 4,0 m
15
100
15
100
15
100
15
15
762
H: 1,2 m
4
100
51.5
110
SCARA MOBILA S4
STAIR S4
h=6.51m
100
15
100
8
7
6
5
4
3
2
REV ZONE
1
DESCRIPTION
DATE
APPROVED
F
F
960
A
E
E
2280
2200
D
D
15
A
OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996)
<= 3(mm)
<6
>6
0.2
0.5
1
> 2000
2
B
C
B
OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996)
<= 3 (mm)
>3
>6
> 30
> 120
> 400
> 1000
0.1
0.1
0.2
0.3
0.5
0.8
1.2
C
A-A ( 1:8 )
A
NB1 - PER INFORMAZIONI VEDERE PIANTA DIS. LS_F12LRA01B - CANCELLO ROOF
PROJECT:
ASSEMBLY:
INFN - LNF
SUB-ASSEMBLY:
Q.TY:
MATERIAL:
Ra:
TREATMENT:
GENERAL TOLERANCES UNI EN 22768-1-1996
National Institute of Nuclear Physics
Frascati National Laboratories
DESCRIPTION:
DRAWN:
DATE:
CAD FILE NAME:
APPROVED:
DATE:
MASS(kg):
SCALE:
REALEASED:
DATE:
SIZE:
SHEET N :
CANCELLO ROOF
DRAWING N :
8
7
6
5
4
3
2
A
ELI-070-01-00
1
REV:
00
15
100
100
15
100
100
95
70
15
17.5
15
15
42.5
60
100
100
137.5
172.5
100
15
100
150
15
259.4
H: 1,50 m
100
259.4
H: 1,50 m
15
100
15
100
15
100
15
100
15
100
15
100
15
11855
100
15
100
15
8
7
6
5
4
3
2
REV ZONE
1
DESCRIPTION
DATE
APPROVED
F
F
9830
3020
840
E
E
2280
2200
(1870)
A
4000
> 2000
2
B
C
B
OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996)
<= 3 (mm)
>3
>6
> 30
> 120
> 400
> 1000
0.1
0.1
0.2
0.3
0.5
0.8
1.2
C
D
OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996)
<= 3(mm)
<6
>6
0.2
0.5
1
D
NB1 - PER INFORMAZIONI VEDERE PIANTA DIS. LS_F12LRA01B - CANCELLATA ROOF
PROJECT:
ASSEMBLY:
INFN - LNF
SUB-ASSEMBLY:
Q.TY:
MATERIAL:
Ra:
TREATMENT:
GENERAL TOLERANCES UNI EN 22768-1-1996
National Institute of Nuclear Physics
Frascati National Laboratories
DESCRIPTION:
DRAWN:
DATE:
CAD FILE NAME:
APPROVED:
DATE:
MASS(kg):
SCALE:
REALEASED:
DATE:
SIZE:
SHEET N :
CANCELLATA ROOF
DRAWING N :
8
7
6
5
4
3
2
A
ELI-070-02-00
1
REV:
00
8
7
6
5
4
3
2
REV ZONE
1
DESCRIPTION
DATE
APPROVED
F
F
GUIDA DI SCORRIMENTO
( ROLLON )
E
E
5360
2720
A
D
D
800
800
A
C
A-A ( 1 : 10 )
A
> 2000
2
B
2210
B
OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996)
<= 3 (mm)
>3
>6
> 30
> 120
> 400
> 1000
0.1
0.1
0.2
0.3
0.5
0.8
1.2
C
OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996)
<= 3(mm)
<6
>6
0.2
0.5
1
2370
250
PROJECT:
ASSEMBLY:
SUB-ASSEMBLY:
Ra:
ELI
INFN - LNF
Q.TY:
MATERIAL:
GENERAL TOLERANCES UNI EN 22768-1-1996
DESCRIPTION:
CAD FILE NAME:
LOLLO V.
DATE:
27.04.2016
APPROVED:
DATE:
MASS(kg):
SCALE:
REALEASED:
PIOLI S.
DATE:
27.04.2016
SIZE:
SHEET N :
DRAWING N :
8
7
6
5
4
3
2
A
1
National Institute of Nuclear Physics
Frascati National Laboratories
DRAWN:
TREATMENT:
ELI-070-06-00
1
REV:
00
8
7
6
5
4
3
2
REV ZONE
1
DESCRIPTION
DATE
APPROVED
F
F
E
E
GUIDA DI SCORRIMENTO
( ROLLON )
5360
2720
960
880
A
D
D
A
2210
C
A-A ( 1 : 10 )
A
> 2000
2
B
2370
B
OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996)
<= 3 (mm)
>3
>6
> 30
> 120
> 400
> 1000
0.1
0.1
0.2
0.3
0.5
0.8
1.2
C
OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996)
<= 3(mm)
<6
>6
0.2
0.5
1
2280
250
PROJECT:
ASSEMBLY:
SUB-ASSEMBLY:
Ra:
ELI
INFN - LNF
Q.TY:
MATERIAL:
GENERAL TOLERANCES UNI EN 22768-1-1996
DESCRIPTION:
CAD FILE NAME:
LOLLO V.
DATE:
27.04.2016
APPROVED:
DATE:
MASS(kg):
SCALE:
REALEASED:
PIOLI S.
DATE:
27.04.2016
SIZE:
SHEET N :
DRAWING N :
8
7
6
5
4
3
2
A
1
National Institute of Nuclear Physics
Frascati National Laboratories
DRAWN:
TREATMENT:
ELI-070-03-00
1
REV:
00