Allegato B Pagina 2: Pianta Cancello Roof (Ingresso Scale) Pagina 3: Disegno Cancello Roof Pagina 4: Pianta Cancellata Roof (Piano Superiore) Pagina 5: Disegno Cancellata Roof Pagina 6: Pianta Accesso AB1 Pagina 7: Disegno Cancello scorrevole AB1 (accesso interno) Pagina 8: Pianta Accesso AB2 Pagina 9: Disegno Cancello scorrevole AB2 (accesso interno) ES GENERAL ACCESS AREA m² (din care 28.2 m² chepeng-uri acces subsol tehnic) 105 100 15 100 15 H: 2,2 m H: 4,0 m 15 100 15 100 15 100 15 15 762 H: 1,2 m 4 100 51.5 110 SCARA MOBILA S4 STAIR S4 h=6.51m 100 15 100 8 7 6 5 4 3 2 REV ZONE 1 DESCRIPTION DATE APPROVED F F 960 A E E 2280 2200 D D 15 A OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996) <= 3(mm) <6 >6 0.2 0.5 1 > 2000 2 B C B OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996) <= 3 (mm) >3 >6 > 30 > 120 > 400 > 1000 0.1 0.1 0.2 0.3 0.5 0.8 1.2 C A-A ( 1:8 ) A NB1 - PER INFORMAZIONI VEDERE PIANTA DIS. LS_F12LRA01B - CANCELLO ROOF PROJECT: ASSEMBLY: INFN - LNF SUB-ASSEMBLY: Q.TY: MATERIAL: Ra: TREATMENT: GENERAL TOLERANCES UNI EN 22768-1-1996 National Institute of Nuclear Physics Frascati National Laboratories DESCRIPTION: DRAWN: DATE: CAD FILE NAME: APPROVED: DATE: MASS(kg): SCALE: REALEASED: DATE: SIZE: SHEET N : CANCELLO ROOF DRAWING N : 8 7 6 5 4 3 2 A ELI-070-01-00 1 REV: 00 15 100 100 15 100 100 95 70 15 17.5 15 15 42.5 60 100 100 137.5 172.5 100 15 100 150 15 259.4 H: 1,50 m 100 259.4 H: 1,50 m 15 100 15 100 15 100 15 100 15 100 15 100 15 11855 100 15 100 15 8 7 6 5 4 3 2 REV ZONE 1 DESCRIPTION DATE APPROVED F F 9830 3020 840 E E 2280 2200 (1870) A 4000 > 2000 2 B C B OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996) <= 3 (mm) >3 >6 > 30 > 120 > 400 > 1000 0.1 0.1 0.2 0.3 0.5 0.8 1.2 C D OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996) <= 3(mm) <6 >6 0.2 0.5 1 D NB1 - PER INFORMAZIONI VEDERE PIANTA DIS. LS_F12LRA01B - CANCELLATA ROOF PROJECT: ASSEMBLY: INFN - LNF SUB-ASSEMBLY: Q.TY: MATERIAL: Ra: TREATMENT: GENERAL TOLERANCES UNI EN 22768-1-1996 National Institute of Nuclear Physics Frascati National Laboratories DESCRIPTION: DRAWN: DATE: CAD FILE NAME: APPROVED: DATE: MASS(kg): SCALE: REALEASED: DATE: SIZE: SHEET N : CANCELLATA ROOF DRAWING N : 8 7 6 5 4 3 2 A ELI-070-02-00 1 REV: 00 8 7 6 5 4 3 2 REV ZONE 1 DESCRIPTION DATE APPROVED F F GUIDA DI SCORRIMENTO ( ROLLON ) E E 5360 2720 A D D 800 800 A C A-A ( 1 : 10 ) A > 2000 2 B 2210 B OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996) <= 3 (mm) >3 >6 > 30 > 120 > 400 > 1000 0.1 0.1 0.2 0.3 0.5 0.8 1.2 C OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996) <= 3(mm) <6 >6 0.2 0.5 1 2370 250 PROJECT: ASSEMBLY: SUB-ASSEMBLY: Ra: ELI INFN - LNF Q.TY: MATERIAL: GENERAL TOLERANCES UNI EN 22768-1-1996 DESCRIPTION: CAD FILE NAME: LOLLO V. DATE: 27.04.2016 APPROVED: DATE: MASS(kg): SCALE: REALEASED: PIOLI S. DATE: 27.04.2016 SIZE: SHEET N : DRAWING N : 8 7 6 5 4 3 2 A 1 National Institute of Nuclear Physics Frascati National Laboratories DRAWN: TREATMENT: ELI-070-06-00 1 REV: 00 8 7 6 5 4 3 2 REV ZONE 1 DESCRIPTION DATE APPROVED F F E E GUIDA DI SCORRIMENTO ( ROLLON ) 5360 2720 960 880 A D D A 2210 C A-A ( 1 : 10 ) A > 2000 2 B 2370 B OFFSET SIZE LIMIT FOR LINEAR DIMENSIONS (UNI EN 22768-1:1996) <= 3 (mm) >3 >6 > 30 > 120 > 400 > 1000 0.1 0.1 0.2 0.3 0.5 0.8 1.2 C OFFSET SIZE LIMIT FOR CHAMFERS-FILLETS (UNI EN 22768-1:1996) <= 3(mm) <6 >6 0.2 0.5 1 2280 250 PROJECT: ASSEMBLY: SUB-ASSEMBLY: Ra: ELI INFN - LNF Q.TY: MATERIAL: GENERAL TOLERANCES UNI EN 22768-1-1996 DESCRIPTION: CAD FILE NAME: LOLLO V. DATE: 27.04.2016 APPROVED: DATE: MASS(kg): SCALE: REALEASED: PIOLI S. DATE: 27.04.2016 SIZE: SHEET N : DRAWING N : 8 7 6 5 4 3 2 A 1 National Institute of Nuclear Physics Frascati National Laboratories DRAWN: TREATMENT: ELI-070-03-00 1 REV: 00