PLANT & PETROCHEM CABLES GENERAL CATALOGUE Plant & Petrochem Cables technergy TM INTEGRATED CABLING SOLUTIONS 1 TEPLA Plant & Petrochem Cables technergy TM INTEGRATED CABLING SOLUTIONS Introduction All chemical, petrochemical, power and industrial plants require complex and integrated power, control and instrumentation systems. TechnergyTM is a central provider of power and communication network cabling for harsh and demanding Plant and Petrochemical environments. Due to the extreme environmental conditions they have to withstand, this cables must guarantee: • • • • • Installation in harsh environments Direct contact with chemical agents (oils, greases, strong hydrocarbons) Resistance to fire Low emission of dark smokes Low emission of corrosive gases TechnergyTM Plant and Petrochemical cables ensure outstanding performances with advanced and innovative solutions in terms of materials and design, such as Drylam (chemical and moisture barrier) and Airbag (revolutionary polymeric shock absorption system). A vast experience as a supplier to the hydrocarbon processing industry and in worldwide power plant projects make Prysmian a reliable partner for all key players in the Plant and Petrochemical industry. 1 Index Instrumentation cables TEPLA Plant & Petrochem Cables Identification codes pag. 08 Symbols pag. 10 > according to BS 5308 TEPLA I - 0 (PE/PVC or XLPE/LS0H) pag. 12 TEPLA I - I0 (PE/PVC or XLPE/LS0H) pag. 14 TEPLA I - 0A (PE/SWA/PVC or XLPE/SWA/LS0H) pag. 16 TEPLA I - I0A (PE/SWA/PVC or XLPE/SWA/LS0H) pag. 18 TEPLA I - OLA (PE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) pag. 20 TEPLA I - ODA (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) pag. 22 TEPLA I - 0 (PE/PVC or XLPE/LS0H) pag. 24 TEPLA I - 0 (PVC/PVC) pag. 26 TEPLA I - I0 (PVC/PVC) pag. 28 TEPLA I - OA (PVC/SWA/PVC) pag. 30 TEPLA I - I0A (PVC/SWA/PVC) pag. 32 TEPLA I - FR - 0 (XLPE/LS0H) pag. 34 TEPLA I - FR - 0A 2 (XLPE/SWA/LS0H) pag. 36 technergy TM INTEGRATED CABLING SOLUTIONS Instrumentation cables > according to EN 50288 TEPLA I - 0 (PE/PVC or XLPE/PVC or XLPE/LS0H) pag. 40 TEPLA I - I0 (PE/PVC or XLPE/PVC or XLPE/LS0H) pag. 42 TEPLA I - 0A (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) pag. 44 TEPLA I - I0A (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) pag. 46 TEPLA I - OLA (PE/Pb/SWA/PVC or XLPE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) pag. 48 TEPLA I - ODA (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) pag. 50 TEPLA I - FR - O (XLPE/LS0H) pag. 52 TEPLA I - FR - O (G4/PVC or G4/LS0H) pag. 54 TEPLA I - FR - OA (XLPE/LS0H) pag. 56 TEPLA I - FR - OA (G4/PVC or G4/LS0H) pag. 58 TEPLA I - O (PE/PVC or XLPE/PVC or XLPE/LS0H) pag. 60 TEPLA I - FR - O (XLPE/LS0H) pag. 62 TEPLA I - FR - O (G4/PVC or G4/LS0H) pag. 64 3 Index TEPLA Plant & Petrochem Cables Thermocouple cables Standards of extension & compensating cables for thermocouples Thermocouple cables > pag. 68 according to BS 5308 TEPLA T - IO (PE/PVC or XLPE/LS0H) pag. 72 TEPLA T - IOA (PE/SWA/PVC or XLPE/SWA/LS0H) Thermocouple cables > pag. 74 according to EN 50288 TEPLA T - I0 (PE/PVC or XLPE/LS0H) pag. 78 TEPLA T - I0A (PE/SWA/PVC or XLPE/SWA//LS0H) Control cables > pag. 80 according to BS 5308 TEPLA C - S (PVC/PVC or XLPE/LS0H) pag. 84 TEPLA C - SA (PVC/SWA/PVC or XLPE/SWA/LS0H) pag. 86 TEPLA C (XLPE/PVC or XLPE/LS0H) pag. 88 TEPLA C - A (XLPE/SWA/PVC or XLPE/SWA/LS0H) pag. 90 TEPLA C - FR (XLPE/LS0H) pag. 92 TEPLA C - FR - A (XLPE/SWA/LS0H) Control cables > pag. 94 according to EN 50288 TEPLA C - S (PVC/PVC or XLPE/LS0H) pag. 98 TEPLA C - SA 4 (PVC/SWA/PVC or XLPE/SWA/LS0H) pag. 100 technergy TM INTEGRATED CABLING SOLUTIONS Communication cables TEPLA COM - S IBM STANDARD Power cables > pag. 104 Low Voltage & Earthing cables TEPLA E (PVC) pag. 108 TEPLA L (XLPE/PVC or XLPE/LS0H) - single core pag. 110 TEPLA L - A (XLPE/AWA/PVC OR XLPE/AWA/LS0H) - single core pag. 112 TEPLA L (XLPE/PVC or XLPE/LS0H) - multi-core pag. 114 TEPLA L - A (XLPE/SWA/PVC or XLPE/SWA/LS0H) - multi-core pag. 116 TEPLA L - (AR) (XLPE/PSA/PVC) - single core pag. 118 TEPLA L - (AR) (XLPE/PSA/PVC) - multi-core pag. 120 TEPLA L - L (XLPE/Pb/PVC) - single core pag. 122 TEPLA L - L (XLPE/Pb/PVC) - multi-core pag. 124 TEPLA L - LA (XLPE/Pb/AWA/PVC) - single core pag. 126 TEPLA L - LA (XLPE/Pb/PVC/SWA/PVC) - multi-core pag. 128 TEPLA L - D (XLPE/DRYLAM/PVC) - single core pag. 130 TEPLA L - D (XLPE/DRYLAM/PVC) - multi-core pag. 132 5 TEPLA Plant & Petrochem Cables Power cables > Medium Voltage cables TEPLA M - S (XLPE/CuT/PVC or XLPE/CuT/LS0H) - single core pag. 136 TEPLA M - S (XLPE/CuT/PVC or XLPE/CuT/LS0H) - multi-core pag. 138 TEPLA M - SA (XLPE/CuT/AWA/PVC or XLPE/CuT/AWA/LS0H ) - single core pag.140 TEPLA M - SA (XLPE/CuT/SWA/PVC or XLPE/CuT/SWA/LS0H ) - multi-core pag.142 TEPLA M - S(AR) (XLPE/CuW/PSA/PVC) - single core pag. 144 TEPLA M - S(AR) (XLPE/CuW/PSA/PVC) - multi-core pag. 146 TEPLA M - L (XLPE/Pb/PVC) - single core pag. 148 TEPLA M - SL (XLPE/CuT/Pb/PVC) - multi-core pag. 150 TEPLA M - D (XLPE/DRYLAM/PVC) - single core pag. 152 TEPLA M - SD (XLPE/CuT/DRYLAM/PVC) - multi-core 6 pag. 154 technergy TM INTEGRATED CABLING SOLUTIONS 7 Identification codes Conductor Insulation Assembly Metallic screen Armour/metallic sheath Separation sheath/outer sheath 8 TEPLA Plant & Petrochem Cables A round aluminium conductor F round flexible conductor R round rigid conductor U round solid conductor T mica glass tape E polyethylene insulation E4 XLPE insulation R PVC insulation G4 silicon O laid-up cores X twisted pairs/triads/quads H aluminium tape screen H1 copper tape/wire screen H5 aluminium/polyethylene longitudinally bonded tape screen F steel wires armour L lead alloy sheath N steel tapes armour (AR) PSA (AIR BAG™) R PVC sheath R4 polyamide M1 LS0H thermoplastic sheath technergy TM INTEGRATED CABLING SOLUTIONS 9 Symbols TEPLA Plant & Petrochem Cables Fire behaviour ACCORDING TO IEC 60332-1 flame retardant IEC 60332-3 cat A fire retardant IEC 60332-3 cat C fire retardant IEC 60331 fire resistant Chemicals resistance Outer sheath resistance to chemicals Impacts Cable mechanical resistance to impacts Smoke density, corrosivity and toxicity low Low emission of smoke, acid and toxic gases IEC 61034 (smoke) IEC 60754 (acid and toxic gases) Temperature Permissible minimum ambient temperature during laying Lead free Pb Bending radius r Minimum bending radius during installation 10 Note: in case of laying operation with controlled bending (bending over a shape, careful bending at terminations) at a temperature not lower than 15 °C, the specified bending radius may be halved. technergy TM INTEGRATED CABLING SOLUTIONS Instrumentation cables according to BS 5308 11 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - O (PE/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 12 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - O 300/500 V (PE/PVC or XLPE/LS0H) Type* UEXHR UEXOHR FEXHR FEXOHR FEXHR FEXOHR UEXHR UEXOHR REXHR REXOHR (mm2) (mm) (Ω/km) (mm) Diameter over assembly plastic tape (mm) 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 36,0 36,0 36,0 36,0 36,0 36,0 36,0 1,8 1,8 1,8 1,8 1,8 1,8 1,8 3,7 4,4 9,7 12,0 14,2 16,3 19,9 5,4 6,1 12,0 14,5 16,7 19,0 22,6 39 56 138 226 308 400 561 65 73 144 174 200 228 271 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 4,2 5,0 11,0 13,7 16,2 18,6 22,7 5,9 6,7 13,3 16,2 18,9 21,2 24,6 42 59 149 244 341 428 616 71 80 160 194 227 254 295 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,75 2x2x0,75 Q 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,0 1,0 1,0 1,0 1,0 1,0 1,0 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,6 5,5 12,1 15,0 17,8 20,4 24,9 6,3 7,2 14,6 17,7 20,4 23,5 28,4 53 81 212 360 500 665 969 76 86 175 212 245 282 341 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1 2x2x1 Q 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 18,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,7 5,7 12,4 15,5 18,3 21,0 25,7 6,4 7,4 14,9 17,9 20,9 24,0 28,7 55 84 218 362 515 685 971 77 89 179 215 251 288 344 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1,5 2x2x1,5 Q 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,8 14,9 18,5 21,9 25,1 30,7 7,4 8,7 17,4 21,2 24,9 28,2 34,1 71 118 297 517 754 970 1420 89 104 209 254 299 338 409 115 115 85 85 85 85 85 40 40 40 40 40 40 40 Cross section Diameter of Maximum DC resistance conductor at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) (kg/km) (mm) (pF/m) (µH/Ω) * Refers only to PE/PVC construction 13 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IO (PE/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Identification pairs blue, black numbered Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 14 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - IO 300/500 V (PE/PVC or XLPE/LS0H) (mm2) (mm) (Ω/km) (mm) Diameter over assembly plastic tape (mm) FEXHOHR 2x2x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 7,9 11,4 14,2 16,8 19,2 23,5 10,2 13,9 16,9 19,8 22,3 27,0 100 190 319 460 584 848 122 167 203 238 268 324 115 115 115 115 115 115 25 25 25 25 25 25 FEXHOHR 2x2x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 8,6 12,5 15,5 18,3 21,0 25,7 10,9 14,9 18,2 21,4 24,5 29,8 124 245 426 620 821 1212 131 179 218 257 294 358 115 115 115 115 115 115 25 25 25 25 25 25 UEXHOHR 2x2x1 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 2,3 2,3 2,3 2,3 2,3 2,3 8,9 12,8 15,9 18,8 21,7 26,5 11,1 15,3 18,6 21,9 25,2 29,1 127 253 438 638 851 1230 133 184 223 263 302 349 115 115 115 115 115 115 25 25 25 25 25 25 REXHOHR 2x2x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 10,5 15,2 18,9 22,3 25,7 31,8 13,0 17,9 22,0 25,8 29,1 33,8 170 342 612 886 1139 1667 156 215 264 310 349 406 115 115 115 115 115 115 40 40 40 40 40 40 Type* Cross section Diameter of Maximum DC resistance conductor at 20 °C Diameter over insulation Min bending Capacitance radius L/R Outer diameter approx Weight of cable approx (mm) (kg/km) (mm) (pF/m) (µH/Ω) * Refers only to PE/PVC construction 15 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - OA (PE/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding polyethylene type 03 according to BS 6234 or LS0H thermoplastic compound Armour galvanized steel wire Outer sheath PVC type TM1 in accordance with BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 16 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - OA 300/500 V (PE/SWA/PVC or XLPE/SWA/LS0H) Type* Cross section (mm2) UEXHEFR UEXOHEFR FEXHEFR FEXOHEFR FEXHEFR FEXOHEFR UEXHEFR UEXOHEFR REXHEFR REXOHEFR Diameter Diameter Diameter Outer Weight of Min Diameter Maximum Diameter Diameter Diameter Capacitance over of armour over over DC of over cable bending diameter conductor resistance insulation assembly armour wires approx approx radius inner innr at 20 °C plastic tape sheath sheath (Ω/km) (mm) (mm) (kg/km) (pF/m) (mm) (mm) (mm) (mm) (mm) (mm) L/R (µH/Ω) 2x0,5 4x0,5 15x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 36,0 36,0 36,0 36,0 36,0 36,0 36,0 1,8 1,8 1,8 1,8 1,8 1,8 1,8 3,7 4,4 9,6 12,0 14,2 16,3 19,9 5,4 6,1 12,0 14,5 16,7 19,0 22,6 0,9 0,9 0,9 1,3 1,3 1,6 1,6 7,2 7,9 13,8 17,0 19,2 22,2 25,8 9,8 10,5 16,8 20,2 22,4 25,6 29,4 193 228 447 718 858 1170 1494 137 147 235 283 314 358 412 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,5 4x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 4,2 5,0 11,0 13,7 16,2 18,6 22,6 5,8 6,7 13,3 16,2 18,9 21,2 25,6 0,9 0,9 1,3 1,3 1,6 1,6 1,6 7,7 8,5 15,8 18,7 22,1 24,4 28,8 10,3 11,1 18,8 21,9 25,5 28,0 32,6 209 240 582 780 1111 1300 1629 144 155 263 307 357 392 456 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,75 4x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,6 5,5 12,1 15,0 17,8 20,4 24,9 6,3 7,2 14,6 17,7 20,4 23,5 28,4 0,9 0,9 1,3 1,6 1,6 1,6 2,0 8,1 9,0 17,1 20,9 23,6 26,7 32,4 10,7 11,8 20,1 24,3 27,2 30,3 36,4 233 289 714 1112 1374 1651 2425 150 165 281 340 381 424 510 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1 4x1 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 18,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,7 5,7 12,4 15,5 18,3 21,0 25,7 6,4 7,4 14,9 17,9 20,9 24,0 28,7 0,9 0,9 1,3 1,6 1,6 1,6 2,0 8,2 9,2 17,4 21,1 24,1 27,2 32,7 10,8 12,0 20,4 24,5 27,7 30,8 36,7 236 286 715 1113 1386 1658 2395 151 168 286 343 388 431 514 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1,5 4x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,8 14,9 18,5 21,9 25,1 30,7 7,4 9,1 17,4 21,2 24,9 28,2 34,1 0,9 0,9 1,3 1,6 1,6 2,0 2,0 9,2 10,9 19,9 24,4 28,1 32,2 38,1 12,0 13,7 23,1 28,0 31,9 36,2 42,3 277 362 876 517 1771 2364 3123 168 192 323 392 447 507 592 115 115 85 85 85 85 85 40 40 40 40 40 40 40 * Refers only to PE/SWA/PVC construction 17 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IOA (PE/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding polyethylene type 03 according to BS 6234 or LS0H thermoplastic compound Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 18 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - IOA 300/500 V (PE/SWA/PVC or XLPE/SWA/LS0H) Type* Cross section (mm2) Diameter Maximum Diameter Diameter Diameter Diameter Diameter Outer Weight of Min Capacitance over of armour over over DC of over diameter cable bending conductor resistance insulation assembly armour approx approx radius wires inner at 20 °C plastic tape sheath (Ω/km) (mm) (mm) (mm) (kg/km) (pF/m) (mm) (mm) (mm) (mm) (mm) L/R (µH/Ω) FEXHOHEFR 2x2x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 7,9 11,4 14,2 16,8 19,2 23,5 10,2 13,9 16,9 19,8 22,3 27,0 0,9 1,3 1,6 1,6 1,6 2,0 12,0 16,4 20,1 23,0 25,5 31,0 15,0 19,6 23,7 26,6 29,3 35,2 364 644 1017 1254 1476 2166 210 274 332 372 410 493 115 115 115 115 115 115 25 25 25 25 25 25 FEXHOHEFR 2x2x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 8,6 12,5 15,5 18,3 21,0 25,7 10,9 14,9 18,2 21,4 24,5 29,8 0,9 1,3 1,6 1,6 2,0 2,0 12,7 17,4 21,4 24,6 28,5 33,8 15,7 20,6 25,0 28,4 32,5 38,2 425 771 1212 1534 2079 2774 220 288 350 398 455 535 115 115 115 115 115 115 25 25 25 25 25 25 UEXHOHEFR 2x2x1 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 2,3 2,3 2,3 2,3 2,3 2,3 8,9 12,8 15,9 18,8 21,7 26,0 11,1 15,3 18,6 21,9 25,1 30,0 0,9 1,3 1,6 1,6 2,0 2,0 12,9 17,8 21,8 25,1 29,1 34,0 15,9 21,0 25,4 28,9 33,1 38,4 412 746 1198 1510 2150 2645 223 294 356 405 463 538 115 115 115 115 115 115 25 25 25 25 25 25 REXHOHEFR 2x2x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 10,5 15,2 18,9 22,3 25,7 31,3 13,0 17,9 22,0 25,8 29,1 35,4 1,3 1,6 1,6 2,0 2,0 2,0 15,5 21,1 25,2 29,8 33,1 39,4 18,7 24,5 29,0 33,8 37,3 44,2 599 1067 1502 2125 2552 3402 262 343 406 473 522 619 115 115 115 115 115 115 40 40 40 40 40 40 * Refers only to PE/SWA/PVC construction 19 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - OLA (PE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) 300/500 V Construction > > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC Lead sheath inner sheath Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) r IEC 60332-1 IEC 60332-3C EXELLENT EXCELLENT 0 °C 16 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 20 EXELLENT EXCELLENT LS0H -5 °C 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - OLA 300/500 V (PE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) Type* UEXHRLRFR UEXOHRLRFR FEXHRLRFR FEXOHRLRFR FEXHRLRFR FEXOHRLRFR UEXHRLRFR UEXOHRLRFR REXHRLRFR REXOHRLRFR Cross Diameter Maximu Diameter Diameter Diameter Diameter Diameter Diameter Outer Weight Min Capacitance L/R over inner over lead of over diameter of cable bending DC section under of over armour armour armour approx approx radius sheath conductor resistance insulation sheath at 20 °C wires 2 (µH/Ω) (Ω/km) (mm ) (mm) (mm) (mm) (mm) (kg/km) (mm) (pF/m) (mm) (mm) (mm) (mm) 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 36,0 36,0 36,0 36,0 36,0 36,0 36,0 1,8 1,8 1,8 1,8 1,8 1,8 1,8 5,3 6,0 11,8 14,4 16,6 18,9 22,5 7,5 8,2 14,0 16,6 19,0 21,5 25,3 9,1 9,8 15,6 18,6 21,0 23,5 27,3 0,9 0,9 0,9 1,3 1,3 1,6 1,6 10,9 11,6 17,4 21,1 23,5 26,7 30,5 13,7 14,4 20,6 24,5 27,1 30,3 34,3 580 640 1140 1580 1920 2460 3060 219 231 330 392 434 485 549 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 5,8 6,6 13,2 16,1 18,8 21,2 25,6 8,0 8,8 15,4 18,5 21,4 23,8 28,6 9,6 10,4 17,0 20,5 23,4 25,8 31,0 0,9 0,9 1,3 1,6 1,6 1,6 2,0 11,4 12,2 19,5 23,7 26,6 29,0 35,0 14,2 15,0 22,7 27,3 30,2 32,8 39,2 620 690 1240 170 2140 2710 3430 227 240 363 437 483 525 627 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,75 2x2x0,75 Q 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 6,2 7,1 14,5 17,4 20,4 23,4 27,9 8,4 9,3 16,7 19,8 23,0 26,2 30,9 10,0 10,9 18,7 21,8 25,0 28,6 33,3 0,9 0,9 1,6 1,6 1,6 2,0 2,0 11,8 12,7 21,9 25,0 28,2 32,6 37,3 14,6 15,7 25,3 28,6 32,0 36,6 41,5 660 750 1540 2220 2710 3160 4500 234 252 405 458 512 586 664 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1 2x2x1 Q 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 18,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 6,3 7,3 14,8 17,9 20,9 24,0 28,7 8,5 9,5 17,0 20,3 23,5 26,8 31,7 10,1 11,1 19,0 22,3 25,5 29,2 34,1 0,9 0,9 1,6 1,6 1,6 2,0 2,0 11,9 12,9 22,2 25,5 28,7 33,2 38,1 14,7 15,9 25,6 29,1 32,5 37,2 42,3 670 770 1760 2260 2780 3660 4590 236 254 410 466 520 595 677 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1,5 2x2x1,5 Q 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 7,3 8,6 17,3 21,1 24,9 28,1 34,1 9,5 10,8 19,7 23,7 27,7 31,1 37,5 11,1 12,4 21,7 25,7 30,1 33,5 40,3 0,9 1,3 1,6 1,6 2,0 2,0 2,5 12,9 14,9 24,9 28,9 34,1 37,5 45,3 15,9 17,9 28,3 32,7 38,1 41,7 49,9 750 890 2050 2690 3400 4380 5620 254 286 453 523 610 667 798 115 115 85 85 85 85 85 40 40 40 40 40 40 40 * Refers only to PE/LEAD/SWA/PVC construction 21 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - ODA (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) 300/500 V Construction > > > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C EXELLENT EXCELLENT 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC Chemical moisture barrier longitudinally applied AI tape bonded with extruded chemical resistant polymeric layer Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 22 EXELLENT EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - ODA 300/500 V (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) Type* Cross section (mm2) Diameter Maximum DC of conductor resistance at 20 °C (Ω/km) (mm) Diameter over insulation (mm) Diameter Diameter of Diameter over armour over inner wires armour sheath (mm) (mm) (mm) Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) (kg/km) (mm) (pF/m) (µH/Ω) RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 8,77 12,45 14,11 15,95 16,26 18,94 19,85 21,73 24,41 26,25 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 10,57 14,24 15,91 17,75 18,06 20,74 21,65 23,53 26,91 28,75 13,3 17,1 18,8 20,6 21,0 23,8 24,7 26,8 30,1 32,2 324,4 490,6 569,1 645,9 679,2 852,6 925,6 1057,2 1412,9 1584,8 186 240 263 289 293 334 346 376 422 450 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 8,99 12,86 14,62 16,61 16,93 19,95 20,66 22,65 25,49 27,62 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 10,79 14,66 16,42 18,41 18,73 21,75 22,45 25,15 27,99 30,12 13,5 17,6 19,3 21,3 21,8 24,8 25,6 28,4 31,2 33,5 336,6 511,7 602,4 686,8 733,7 929,3 991,4 1295,4 1533,3 1735,9 189 246 270 298 306 348 358 397 437 469 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 9,37 13,65 15,76 17,87 18,02 21,33 22,11 24,51 27,56 29,67 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 11,17 15,45 17,56 19,67 19,82 23,13 24,61 27,01 30,06 32,17 13,9 18,4 20,5 22,8 22,9 26,4 27,8 30,2 33,5 35,6 354,9 559,4 677,2 778,9 813,9 1055,1 1291,5 1491,6 1781,4 1976,0 194 257 286 319 321 370 389 423 468 498 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 10,11 14,95 17,09 19,69 19,86 23,69 24,59 27,02 30,45 33,2 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 11,91 16,75 18,89 21,49 21,66 26,19 27,09 29,52 32,95 36,4 14,8 19,9 22,0 24,6 25,0 29,6 30,5 33,1 36,6 40,2 403,6 647,1 781,8 913,2 971,2 1459,7 1573,5 1806,5 2163,9 2727,4 207 278 308 344 349 414 427 464 512 563 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 10,92 16,56 19,2 21,93 22,32 26,66 27,68 30,65 34,75 37,62 0,9 0,9 1,25 1,25 1,25 1,25 1,25 1,6 1,6 1,6 12,72 18,36 21,7 24,43 24,82 29,16 30,18 33,85 37,95 40,82 15,6 21,5 25,0 27,9 28,3 32,9 34,1 38,0 42,3 45,3 448,5 754,5 1095,5 1283,6 1365,8 1815,8 1983,5 2537,5 3090,5 3509,7 219 300 350 391 396 460 477 531 592 634 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 * Refers only to PE/DRYLAM/SWA/PVC construction 23 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - O (PE/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of IEC 60228 Insulation polyethylene type 03 according to BS 6234 or XLPE Triples twisted Identification triples blue, brown, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 24 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - O 300/500 V (PE/PVC or XLPE/LS0H) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation (mm2) (mm) (Ω/km) UEXHR UEXOHR 3x0,5 2x3x0,5 5x3x0,5 10x3x0,5 15x3x0,5 20x3x0,5 30x3x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 FEXHR FEXOHR 3x0,5 2x3x0,5 5x3x0,5 10x3x0,5 15x3x0,5 20x3x0,5 30x3x0,5 FEXHR FEXOHR Outer diameter approx Weight of cable approx Min bending radius (mm) Diameter over assembly plastic tape (mm) (mm) (kg/km) (mm) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 1,8 1,8 1,8 1,8 1,8 1,8 1,8 3,9 7,4 10,3 13,5 16,6 19,0 23,5 5,5 9,6 12,7 16,1 19,6 22,0 26,9 40 90 170 290 420 540 790 66 115 153 193 235 264 323 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 4,4 8,4 11,7 15,4 18,9 21,6 26,8 6,0 10,6 14,1 18,0 21,9 24,6 30,2 50 100 190 320 470 600 880 72 127 170 216 262 29 362 3x0,75 2x3x0,75 5x3x0,75 10x3x0,75 15x3x0,75 20x3x0,75 30x3x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,9 9,3 12,9 16,9 20,8 23,8 29,5 6,5 11,5 15,3 19,5 23,8 27,2 33,5 60 115 220 395 580 765 1135 78 138 184 234 285 327 402 UEXHR UEXOHR 3x1 2x3x1 5x3x1 10x3x1 15x3x1 20x3x1 30x3x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,0 18,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 5,0 9,5 13,3 17,4 21,3 24,4 30,3 6,6 11,7 15,7 20,0 24,3 27,8 34,3 65 130 260 470 690 915 1360 79 141 188 240 292 334 412 REXHR REXOHR 3x1,5 2x3x1,5 5x3x1,5 10x3x1,5 15x3x1,5 20x3x1,5 30x3x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 6,0 11,4 15,9 20,8 25,6 29,3 36,3 8,2 13,8 18,5 23,8 29,0 32,7 40,3 95 185 380 700 1030 1330 1990 98 166 222 286 347 392 483 Type* * Refers only to PE/PVC construction 25 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - O (PVC/PVC) 300/500 V Construction > > > > > > > > Applicable standards BS 5308-2 Design guidelines IEC 60332-1 Flame retardant IEC 60332-3C Fire retardant on bunched cables (if required) r IEC 60332-1 IEC 60332-3C 26 STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - O 300/500 V (PVC/PVC) Type FRXHR FRXOHR FRXHR FRXOHR RRXHR RRXOHR Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Diameter over assembly plastic tape Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (Ω/km) (mm) (mm) (mm) (kg/km) (mm) 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 4,2 5,0 11,0 13,7 16,2 18,6 22,7 5,9 6,7 13,3 16,2 18,9 21,2 25,8 52 72 169 284 401 508 745 70 80 160 195 230 250 310 2x0,75 2x2x0,75 Q 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,6 5,5 12,1 15,0 17,8 20,4 24,9 6,3 7,2 14,6 17,7 20,4 23,5 28,4 53 81 212 360 500 665 969 80 90 180 210 250 280 340 2x1,5 2x2x1,5 Q 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,9 14,9 18,5 21,9 25,1 30,7 7,6 9,1 17,4 21,2 24,9 28,2 34,1 94 150 328 581 850 1097 1612 90 110 210 255 300 340 410 27 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IO (PVC/PVC) 300/500 V Construction > > > > > > > > > Applicable standards BS 5308-2 Design guidelines IEC 60332-1 Flame retardant IEC 60332-3C Fire retardant on bunched cables (if required) r IEC 60332-1 IEC 60332-3C 28 STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 Pairs twisted Identification pairs blue, black numbered Individul screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - IO 300/500 V (PVC/PVC) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Diameter over assembly plastic tape Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (Ω/km) (mm) (mm) (mm) (kg/km) (mm) FRXHOHR 2x2x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 7,9 11,4 14,2 16,8 19,2 23,5 10,2 13,9 16,9 19,8 22,3 27,0 108 210 359 519 664 968 120 170 200 240 270 320 FRXHOHR 2x2x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 8,6 12,5 15,5 18,3 21,0 25,7 10,9 14,9 18,2 21,4 24,5 29,8 124 245 426 620 821 1212 130 180 220 260 295 360 RRXHOHR 2x2x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 10,6 15,2 18,9 22,3 25,7 31,4 13,3 17,9 22,0 25,8 29,1 35,4 230 373 676 982 1267 1877 160 215 260 310 350 430 Type 29 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - OA (PVC/SWA/PVC) 300/500 V Construction > > > > > > > > > Applicable standards BS 5308-2 Design guidelines IEC 60332-1 Flame retardant IEC 60332-3C Fire retardant on bunched cables (if required) r IEC 60332-1 IEC 60332-3C 30 STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 Pairs twisted Identification pairs blue, black numbered Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC type TM1 according to BS 6746 Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - OA 300/500 V (PVC/SWA/PVC) Type FRXHRFR FRXOHRFR FRXHRFR FRXOHRFR RRXHRFR RRXOHRFR Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation (mm2) (mm) (Ω/km) 2x0,5 4x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 2x0,75 4x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 2x1,5 4x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 Diameter over inner sheath (mm) Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius (mm) Diameter over assembly plastic tape (mm) (mm) (mm) (mm) (kg/km) (mm) 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 4,2 5,1 11,0 13,7 16,2 18,6 23,1 5,9 6,8 13,3 16,2 18,9 21,2 26,2 0,9 0,9 1,3 1,3 1,6 1,6 1,6 7,7 8,6 15,8 18,7 22,1 24,4 29,4 10,3 11,2 18,8 21,9 25,5 28,0 33,2 218 267 630 840 1196 1406 1882 144 157 263 307 357 392 465 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,6 5,5 12,1 15,0 17,8 20,4 24,9 6,3 7,2 14,6 17,7 20,4 23,5 28,4 0,9 0,9 1,3 1,6 1,6 1,6 2,0 8,1 9,0 17,1 20,9 23,6 26,7 32,4 10,7 11,8 20,1 24,3 27,2 30,3 36,4 233 289 714 1112 1374 1651 2425 150 165 281 340 381 424 510 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,8 12,3 18,5 21,9 25,1 30,7 7,4 8,7 14,8 21,2 24,9 28,2 34,1 0,9 0,9 1,3 1,6 1,6 2,0 2,0 9,2 10,5 17,3 24,4 28,1 32,2 38,1 12,0 13,3 20,5 28,0 31,9 36,2 42,3 299 370 826 1478 1899 2525 3358 168 186 287 392 447 507 595 31 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IOA (PVC/SWA/PVC) 300/500 V Construction > > > > > > > > > > Applicable standards BS 5308-2 Design guidelines IEC 60332-1 Flame retardant IEC 60332-3C Fire retardant on bunched cables (if required) r IEC 60332-1 IEC 60332-3C 32 STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 Pairs twisted Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC type TM1 according to BS 6746 Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V BS 5308” 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA I - IOA 300/500 V (PVC/SWA/PVC) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation (mm2) (mm) (Ω/km) FRXHOHRFR 2x2x0,5 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 FRXHOHRFR 2x2x0,75 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 RRXHOHRFR 2x2x1,5 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 Type Diameter over inner sheath (mm) Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius (mm) Diameter over assembly plastic tape (mm) (mm) (mm) (mm) (kg/km) (mm) 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,1 2,1 2,1 2,1 2,1 2,1 2,1 7,9 11,4 14,2 16,8 19,2 19,2 23,5 10,2 13,9 16,9 19,8 22,3 22,3 27,0 0,9 1,3 1,6 1,6 1,6 1,6 2,0 12,0 16,4 20,1 23,0 25,5 25,5 31,0 15,0 19,6 23,7 26,6 29,3 29,3 35,2 393 696 1129 1411 1621 1621 2375 210 274 332 372 410 410 493 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 2,3 2,3 2,3 2,3 2,3 2,3 8,6 12,5 15,5 18,3 21,0 25,7 10,9 14,9 18,2 21,4 24,5 29,8 0,9 1,3 1,6 1,6 2,0 2,0 12,7 17,4 21,4 24,6 28,5 33,8 15,7 20,6 25,0 28,4 32,5 38,2 425 771 1212 1534 2079 2774 220 288 350 398 455 535 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 2,8 2,8 2,8 2,8 2,8 2,8 10,5 15,2 18,9 22,3 25,7 31,4 13,0 17,9 22,0 25,8 29,1 35,4 1,3 1,6 1,6 2,0 2,0 2,0 15,5 21,1 25,2 29,8 33,1 39,4 18,7 24,5 29,0 33,8 37,3 44,2 641 1144 1630 2306 2776 3732 262 343 406 473 522 619 33 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - O (XLPE/LS0H) 300/500 V Construction > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 1 or 2 or 5 of IEC 60228 Fire barrier mica/glass tape Insulation XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath LS0H compound Marking e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V IEC 60331” BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60331 IEC 60754 IEC 61034 Design guideline Flame retardant Fire retardant on bunched cables (if required) Fire resistant test Halogen free properties Low smoke emission low r 34 IEC 60332-1 IEC 60332-3C IEC 60331 GOOD GOOD LS0H 0 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C > Fire resistant cables according to IEC 60331 TEPLA I - FR - O 300/500 V (XLPE/LS0H) Type UTE4XHM1 UTE4XOHM1 FTE4XHM1 FTE4XOHM1 FTE4XHM1 FTE4XOHM1 UTE4XHM1 UTE4XOHM1 RTE4XHM1 RTE4XOHM1 Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) Diameter over assembly plastic tape (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,8 5,7 12,4 15,4 18,2 20,9 25,6 6,4 7,3 14,6 17,8 20,6 23,5 28,2 45 65 165 275 380 490 640 76 88 175 214 247 282 338 115 115 75 75 75 75 75 25 25 25 25 25 25 25 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,6 2,6 2,6 2,6 2,6 2,6 2,6 5,2 6,2 13,6 17,0 20,1 23,0 28,1 6,8 7,8 15,8 19,4 22,7 25,6 31,1 50 70 175 290 410 520 680 82 94 190 232 272 307 373 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x0,75 2x2x0,75 Q 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 3,3 3,3 3,3 3,3 3,3 3,3 3,3 6,6 8,0 17,5 21,7 25,7 29,5 35,9 8,2 9,6 19,9 24,3 28,3 32,5 39,3 55 83 210 360 500 550 700 99 115 238 291 340 389 472 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1 2x2x1 Q 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 18,4 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,9 15,1 18,8 22,2 25,5 31,2 7,3 8,5 17,5 21,2 24,8 28,5 34,2 60 95 250 420 600 790 850 88 102 210 255 298 342 411 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2x1,5 2x2x1,5 Q 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 3,3 3,3 3,3 3,3 3,3 3,3 6,8 8,1 17,7 22,0 26,1 29,9 8,4 9,9 20,1 24,6 29,1 32,9 78 130 330 580 850 1090 101 119 242 295 349 394 115 115 85 85 85 85 40 40 40 40 40 40 Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation (mm2) (mm) (Ω/km) 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 35 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - OA (XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 1 or 2 or 5 of IEC 60228 Fire barrier mica /glass tape Insulation XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding LS0H compound Armour galvanized steel wire Outer sheath LS0H compound Marking e. g. : “PRYSMIAN Afumex year - n x m x csa 300/500 V IEC 60331” BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties Low smoke emission low r 36 IEC 60332-1 IEC 60332-3C IEC 60331 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C > Fire resistant cables according to IEC 60331 TEPLA I - FR - OA 300/500 V (XLPE/SWA/LS0H) Type UTE4XHM1FM1 UTE4XOHM1FM1 FTE4XHM1FM1 FTE4XOHM1FM1 FTE4XHM1FM1 FTE4XOHM1FM1 UTE4XHM1FM1 UTE4XOHM1FM1 RTE4XHM1FM1 RTE4XOHM1FM1 Cross section Diameter Maximu DC Diameter resistance of over conductor at 20 °C insulation Diameter Diameter Diameter over inner of armour over assembly sheath wires plastic tape (mm) (mm) (mm) (mm2) (mm) (Ω/km) (mm) 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,8 0,8 0,8 0,8 0,8 0,8 0,8 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,3 2,3 2,3 2,3 2,3 2,3 2,3 4,8 5,7 12,4 15,4 18,2 20,9 25,6 6,4 7,3 14,6 17,8 20,6 23,5 28,2 2x0,5 2x2x0,5 Q 5x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 30x2x0,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 39,0 39,0 39,0 39,0 39,0 39,0 39,0 2,6 2,6 2,6 2,6 2,6 2,6 2,6 5,2 6,2 13,6 17,0 20,1 23,0 28,1 2x0,75 2x2x0,75 Q 5x2x0,75 10x2x0,75 15x2x0,75 20x2x0,75 30x2x0,75 1,1 1,1 1,1 1,1 1,1 1,1 1,1 26,0 26,0 26,0 26,0 26,0 26,0 26,0 3,3 3,3 3,3 3,3 3,3 3,3 3,3 2x1 2x2x1 Q 5x2x1 10x2x1 15x2x1 20x2x1 30x2x1 1,1 1,1 1,1 1,1 1,1 1,1 1,1 18,4 18,4 18,4 18,4 18,4 18,4 18,4 2x1,5 2x2x1,5 Q 5x2x1,5 10x2x1,5 15x2x1,5 20x2x1,5 30x2x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 Diameter Capacitance Outer Weight of Min over cable diameter bending approx armour approx radius L/R (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) 0,9 0,9 0,9 1,3 1,3 1,6 1,6 8,2 9,1 16,4 20,3 23,1 26,7 31,4 10,8 11,7 19,4 23,5 26,3 30,1 35,0 215 270 670 960 1240 1490 1860 89 102 204 249 288 329 394 115 115 75 75 75 75 75 25 25 25 25 25 25 25 6,8 7,8 15,8 19,4 22,7 25,6 31,1 0,9 0,9 1,3 1,3 1,6 1,6 1,6 8,6 9,6 18,3 21,9 25,9 28,8 34,3 11,2 12,2 21,3 25,1 29,3 32,4 38,1 240 290 620 1100 1380 1620 2025 95 110 221 271 317 359 435 115 115 75 75 75 75 75 25 25 25 25 25 25 25 6,6 8,0 17,5 21,7 25,7 29,5 35,9 8,2 9,6 19,9 24,3 28,3 32,5 39,3 0,9 0,9 1,3 1,6 1,6 1,6 2,0 10,0 11,4 22,4 27,5 31,5 35,7 43,3 12,6 14,2 25,4 30,9 35,1 39,3 47,3 255 310 735 1200 1520 1935 2420 115 134 278 340 396 454 551 115 115 75 75 75 75 75 25 25 25 25 25 25 25 2,8 2,8 2,8 2,8 2,8 2,8 2,8 5,7 6,9 15,1 18,8 22,2 25,5 31,2 7,3 8,5 17,5 21,2 24,8 28,5 34,2 0,9 0,9 1,3 1,6 1,6 1,6 2,0 9,1 10,3 20,0 24,4 28,0 31,7 38,2 11,7 13,1 23,0 27,8 31,6 35,3 42,2 270 330 850 1300 1660 2250 2800 103 119 244 297 348 399 479 115 115 75 75 75 75 75 25 25 25 25 25 25 25 3,3 3,3 3,3 3,3 3,3 3,3 3,3 6,8 8,1 17,7 22,0 26,1 29,9 36,5 8,4 9,9 20,1 24,6 29,1 32,9 39,9 0,9 0,9 1,3 1,6 1,6 2,0 2,0 10,2 11,7 22,6 27,8 32,3 36,9 43,9 13,0 14,5 25,8 31,4 36,1 40,9 48,1 320 400 1175 1640 2360 2800 3500 117 138 282 345 407 460 559 115 115 85 85 85 85 85 40 40 40 40 40 40 40 37 TEPLA Plant & Petrochem Cables 38 technergy TM INTEGRATED CABLING SOLUTIONS Instrumentation cables according to EN 50288 39 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - O (PE/PVC or XLPE/PVC or XLPE/LS0H) 300 or 500 V Construction > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 40 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - O 300 V (PE/PVC or XLPE/PVC or XLPE/LS0H) Cross section Diameter of conductor (mm2) (mm) RE4OHR RE4XOHR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RE4OHR RE4XOHR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RE4OHR RE4XOHR RE4OHR RE4XOHR Type* Min bending radius Capacitance L/R (mm) (pF/m) (µH/Ω) 44 81 121 152 168 254 290 349 454 530 74 120 140 164 166 201 209 232 264 286 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 6,4 10,4 12,2 14,3 14,5 17,5 18,2 20,4 23,1 25,2 48 89 136 171 191 291 338 412 525 626 77 125 146 172 174 210 219 245 277 302 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 11,2 13,3 15,5 15,6 18,9 19,9 22,1 25,2 27,3 57 105 171 208 234 361 425 516 672 789 83 134 160 185 187 227 239 265 302 327 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,7 12,5 14,8 17,2 17,4 21,3 22,2 24,8 28,3 30,6 74 138 229 280 317 502 581 718 937 1102 92 150 178 207 209 255 266 298 339 367 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 8,4 14,1 16,8 19,5 19,9 24,2 25,3 28,3 32,2 35,2 95 186 315 386 449 712 827 1022 1334 1604 101 169 201 234 239 291 303 339 386 423 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Diameter over insulation Outer diameter approx (mm) (mm) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 10,0 11,7 13,7 13,8 16,7 17,4 19,3 22,0 23,8 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 Maximum DC resistance at 20 °C (Ω/km) Weight of cable approx (kg/km) TEPLA I - O 500 V (PE/PVC or XLPE/PVC or XLPE/LS0H) RE4OHR RE4XOHR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 * Refers only to XLPE/PVC construction 41 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IO (PE/PVC or XLPE/PVC or XLPE/LS0H) 300 or 500 V Construction > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Individual screen aluminium/polyester tape 0.024 mm in electrical contact with tinned annealed copper wires of a total section of 0.5 mm2 polyester tape 0.023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 42 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - IO 300 V (PE/PVC or XLPE/PVC or XLPE/LS0H) Type* Cross section Diameter of conductor (mm2) (mm) RE4OHR RE4XHOHR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 12x2x0,5 10x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RE4OHR RE4XHOHR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RE4OHR RE4XHOHR RE4OHR RE4XHOHR Min bending radius Mutual capacitance maximum L/R maximum (mm) (pF/m) (µH/Ω) 44 98 159 193 217 394 334 477 622 741 74 125 149 173 174 222 211 246 280 306 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 6,4 10,9 13,0 15,0 15,4 18,6 19,3 21,6 24,4 26,7 48,1 106 174 212 246 379 437 541 693 826 77 131 155 180 184 223 232 260 293 320 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 11,9 13,9 16,3 16,5 19,9 21,0 23,3 26,5 28,9 57 131 209 262 297 461 544 661 864 1030 83 142 167 196 198 239 252 279 318 347 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,7 12,9 15,4 18,1 18,3 22,3 23,3 26,0 29,6 32,3 74 158 267 335 381 604 700 866 1130 1346 92 155 185 217 220 268 279 312 355 387 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 8,4 14,8 17,5 20,4 20,8 25,3 26,4 29,7 33,7 36,7 95 213 363 445 518 821 955 1193 1556 1852 101 177 210 245 249 303 316 356 404 440 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Diameter over insulation Outer diameter approx (mm) (mm) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 10,5 12,4 14,4 14,5 18,5 17,6 20,5 23,4 25,5 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 Maximum DC resistance at 20 °C (Ω/km) Weight of cable approx (kg/km) TEPLA I - IO 500 V (PE/PVC or XLPE/PVC or XLPE/LS0H) RE4OHR RE4XHOHR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 * Refers only to XLPE/PVC construction 43 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - OA (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) 300 or 500 V Construction > > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Inner sheath PVC or LS0H Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 44 GOOD EXCELLENT LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - OA 300 V (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) Diameter over insulation (mm) Maximum DC resistance at 20 °C (Ω/km) 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RE4OHRFR RE4XOHRFR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RE4OHRFR RE4XOHRFR RE4OHRFR RE4XOHRFR Type* Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) Diameter over inner sheath (mm) (mm) (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 10,0 11,7 13,7 13,8 16,7 17,4 19,3 22,0 23,8 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 8,0 11,8 13,5 15,5 15,6 18,5 19,2 21,1 23,8 26,3 10,7 14,5 16,3 18,4 18,5 21,6 22,3 24,2 27,1 29,5 229 374 458 534 553 728 781 893 1082 1380 149 202 229 258 259 303 312 339 380 413 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 6,4 10,4 12,2 14,3 14,5 17,5 18,2 20,4 23,1 25,2 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 8,2 12,2 14,0 16,1 16,3 19,3 20,0 22,2 25,6 27,7 10,9 14,9 16,9 19,0 19,2 22,4 23,1 25,3 28,8 30,9 241 399 483 571 594 785 845 986 1347 1524 153 209 236 267 268 314 324 355 403 433 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 11,2 13,3 15,5 15,6 18,9 19,9 22,1 25,2 27,3 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 8,7 13,0 15,1 17,3 17,4 20,7 21,7 24,6 27,7 29,8 11,3 15,9 18,0 20,2 20,3 23,8 24,8 27,8 30,9 33,2 260 443 552 641 670 897 988 1308 1572 1780 159 222 252 282 284 333 347 389 432 464 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,7 12,5 14,8 17,2 17,4 21,3 22,2 24,8 28,3 30,6 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 9,5 14,3 16,6 19,0 19,2 23,8 24,7 27,3 30,8 33,1 12,1 17,2 19,7 22,1 22,3 27,0 28,1 30,7 34,4 36,7 299 516 664 769 816 1268 1389 1621 1980 2239 170 240 276 310 312 378 393 430 481 514 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 13,1 19,0 21,9 25,2 25,8 30,3 31,4 35,3 39,4 42,6 345 624 817 1094 1186 1615 1762 2296 2798 3221 184 266 306 353 361 425 439 494 551 597 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Cross section Diameter of conductor (mm2) RE4OHRFR RE4XOHRFR TEPLA I - OA 500 V (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) RE4OHRFR RE4XOHRFR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 8,5 14,1 16,8 19,5 19,9 24,2 25,3 28,3 32,2 35,2 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 1,6 1,6 10,3 15,9 18,6 22,0 22,4 26,7 27,8 31,5 35,4 38,4 * Refers only to XLPE/PVC/SWA/PVC construction 45 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - IOA (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) 300 or 500 V Construction > > > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD EXCELLENT 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Inner sheath PVC or LS0H Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 46 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - IOA 300 V (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) Diameter over insulation (mm) Maximum DC resistance at 20 °C (Ω/km) 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RE4OHRFR RE4XHOHRFR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RE4OHRFR RE4XHOHRFR RE4OHRFR RE4XHOHRFR Type* Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) Diameter over inner sheath (mm) (mm) (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 10,5 12,5 14,4 14,6 17,6 18,6 20,6 23,4 25,6 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 8,0 12,3 14,3 16,2 16,4 19,4 20,4 23,1 25,9 28,1 10,7 15,1 17,1 19,1 19,2 22,5 23,4 26,2 29,3 31,4 229 416 514 594 626 835 914 1220 1472 1668 149 212 240 267 269 314 327 367 410 439 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 6,4 10,9 13,0 15,0 15,4 18,6 19,3 21,7 24,5 26,7 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 8,2 12,7 14,8 16,8 17,2 20,4 21,1 24,2 27,0 29,2 10,9 15,6 17,6 19,7 20,3 23,7 24,4 27,3 30,3 32,6 241 435 546 630 684 917 994 1318 1577 1799 153 218 247 276 284 331 342 383 425 456 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 12,0 14,0 16,5 16,6 20,1 21,2 23,5 26,8 29,2 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 8,7 13,8 15,8 18,3 18,4 22,6 23,7 26,0 29,3 31,7 11,3 16,5 18,6 21,2 21,4 25,6 26,7 29,2 32,4 35,0 260 496 609 732 771 1192 1306 1516 1840 2106 159 231 260 297 299 359 373 409 454 490 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,7 13,0 15,5 18,2 18,4 22,4 23,3 26,1 29,7 32,4 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 1,6 9,5 14,8 17,3 20,0 20,9 24,9 25,8 28,6 32,9 35,6 12,1 17,8 20,3 23,0 24,0 28,2 29,2 32,1 36,6 39,5 299 562 721 852 1056 1427 1554 1832 2472 2812 170 250 284 322 336 395 408 450 512 552 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 13,1 19,7 23,2 26,3 26,7 32,3 33,4 36,9 41,1 45,3 345 679 1021 1198 1289 1974 2154 2558 3118 3896 184 275 325 368 374 452 467 516 575 634 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Cross section Diameter of conductor (mm2) RE4OHRFR RE4XHOHRFR TEPLA I - IOA 500 V (PE/SWA/PVC or XLPE/SWA/LS0H or XLPE/SWA/PVC) RE4OHRFR RE4XHOHRFR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 8,4 14,8 17,6 20,5 20,9 25,4 26,5 29,9 33,8 36,8 0,9 0,9 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2 10,2 16,6 20,1 23,0 23,4 28,6 29,7 33,0 37,0 40,8 * Refers only to XLPE/PVC/SWA/PVC construction 47 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - OLA (PE/Pb/SWA/PVC or XLPE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) 300 or 500 V Construction > > > > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC or LS0H Lead sheath Inner sheath PVC or LS0H Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) r IEC 60332-1 IEC 60332-3A EXELLENT √EXCELLENT 0 °C 16 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 48 EXELLENT EXCELLENT LS0H -5 °C 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - OLA 300 V (PE/Pb/SWA/PVC or XLPE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) Diameter over insulation (mm) Maximum DC resistance at 20 °C (Ω/km) 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RE4OHRLRFR RE4XOHRLRFR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RE4OHRLRFR RE4XOHRLRFR RE4OHRLRFR RE4XOHRLRFR Type* Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) Diameter over inner sheath (mm) (mm) (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 9,9 13,8 15,5 17,6 17,9 20,8 21,5 23,6 26,3 28,3 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 11,7 15,6 17,3 19,4 19,7 23,3 24 26,1 28,8 30,8 14,6 18,6 20,4 22,5 22,8 26,5 27,2 29,3 32,2 34,2 566 889 1033 1186 1274 1716 1807 2094 2424 2739 233 297 327 360 365 424 435 469 515 548 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 10,1 14,3 16,0 18,4 18,5 21,8 22,5 24,7 27,5 29,7 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 11,9 16,1 17,8 20,2 20,3 24,3 25,0 27,2 30,0 32,2 14,8 19,2 21,0 23,3 23,5 27,5 28,2 30,6 33,5 35,8 585 934 1083 1312 1346 1887 1989 2255 2680 2966 237 307 336 373 376 440 452 490 536 573 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 10,8 15,0 17,4 19,5 19,7 23,1 24,1 26,5 29,6 31,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 12,6 16,8 19,2 21,3 21,5 25,6 26,6 29,0 32,1 34,4 15,4 20,0 22,3 24,5 24,8 29,1 30,1 32,5 35,8 38,1 659 1000 1252 1429 1475 2088 2228 2583 3012 3426 247 320 357 391 397 465 481 520 572 609 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 11,5 16,5 18,9 21,5 21,7 25,7 26,6 29,5 33,1 35,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 1,6 1,6 13,3 18,3 20,7 24,0 24,2 28,2 29,1 32,0 36,3 39,1 16,2 21,5 24,0 27,2 27,6 31,9 32,8 35,6 40,2 43,1 722 1182 1428 1865 1926 2518 2679 3141 4041 4510 260 343 385 436 442 510 524 570 642 690 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 804 1561 1889 2244 2358 3477 3695 4335 5204 6386 275 385 432 479 488 588 604 659 727 802 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Cross section Diameter of conductor (mm2) RE4OHRLRFR RE4XOHRLRFR TEPLA I - OLA 500 V (PE/Pb/SWA/PVC or XLPE/Pb/SWA/PVC or XLPE/Pb/SWA/LS0H) RE4OHRLRFR RE4XOHRLRFR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 12,3 18,4 21,0 24,0 24,4 29,5 30,5 33,7 37,8 41,5 0,9 1,25 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2 14,1 20,9 23,5 26,5 26, 32,7 33,7 36,9 41,0 45,5 17,2 24,1 27,0 29,9 30,5 36,7 37,8 41,2 45,5 50,1 * Refers only to XLPE/LS/SWA/PVC construction 49 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - ODA (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) 300 or 500 V Construction > > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A EXELLENT EXCELLENT 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Chemical moisture barrier longitudinally applied AI tape bonded with extruded chemical resistant polymeric layer Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 50 EXELLENT EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - ODA 300 V (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) Type* Cross section (mm2) Diameter Maximum DC of conductor resistance at 20 °C (Ω/km) (mm) Diameter over insulation (mm) Diameter Diameter of Diameter over armour over inner wires armour sheath (mm) (mm) (mm) Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) (kg/km) (mm) (pF/m) (µH/Ω) RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 8,7 12,4 14,1 15,9 16,2 18,9 19,8 21,7 24,4 26,2 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 10,5 14,2 15,9 17,7 18,0 20,7 21,6 23,5 26,9 28,7 13,3 17,1 18,8 20,6 21,0 23,8 24,7 26,8 30,1 32,2 324 491 569 646 679 853 926 1057 1413 1585 186 240 263 289 293 334 346 376 422 450 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 8,9 12,8 14,6 16,6 16,9 19,9 20,6 22,6 25,4 27,6 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 10,7 14,6 16,4 18,4 18,7 21,7 22,4 25,1 27,9 30,1 13,5 17,6 19,3 21,3 21,8 24,8 25,6 28,4 31,2 33,5 337 512 602 687 734 929 991 1295 1533 1736 189 246 270 298 306 348 358 397 437 469 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 9,3 13,6 15,7 17,8 18,0 21,3 22,1 24,5 27,5 29,6 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 11,1 15,4 17,5 19,6 19,8 23,1 24,6 27,0 30,0 32,1 13,9 18,4 20,5 22,8 22,9 26,4 27,8 30,2 33,5 35,6 355 559 677 779 814 1055 1291 1492 1781 1976 194 257 286 319 321 370 389 423 468 498 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 10,1 14,9 17,0 19,6 19,8 23,6 24,5 27,0 30,4 33,2 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 11,9 16,7 18,8 21,4 21,6 26,1 27,0 29,5 32,9 36,4 14,8 19,9 22,0 24,6 25,0 29,6 30,5 33,1 36,6 40,2 404 647 782 913 971 1460 1573 1806 2164 2727 207 278 308 344 349 414 427 464 512 563 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 TEPLA I - ODA 500 V (PE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/PVC or XLPE/DRYLAM/SWA/LS0H) RE4OHRH5R4FR RE4XOHRH5R4FR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 10,9 16,5 19,2 21,9 22,3 26,6 27,6 30,6 34,7 37,6 0,9 0,9 1,25 1,25 1,25 1,25 1,25 1,6 1,6 1,6 12,7 18,3 21,7 24,4 24,8 29,1 30,1 33,8 37,9 40,8 15,6 21,5 25,0 27,9 28,3 32,9 34,1 38,0 42,3 45,3 448 754 1095 1284 1366 1816 1983 2537 3090 3510 219 300 350 391 396 460 477 531 592 634 * Refers only to XLPE/PVC/DRYLAM/SWA/PVC construction 51 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - O (XLPE/LS0H) 300 or 500 V Construction > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 2 Fire barrier mica/glass tape Insulation XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties Low smoke emission low r 52 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD GOOD LS0H 0 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331-23 TEPLA I - FR - O 300 V (XLPE/LS0H) Cross section Diameter of conductor (mm2) (mm) RTE4OHM1 RTE4XOHM1 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RTE4OHM1 RTE4XOHM1 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RTE4OHM1 RTE4XOHM1 RTE4OHM1 RTE4XOHM1 Type Min bending radius Capacitance L/R (mm) (pF/m) (µH/Ω) 57 105 165 200 230 346 394 473 614 730 90 148 176 205 210 254 265 294 336 366 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 7,8 12,8 15,1 17,5 17,9 21,7 22,6 25,3 28,7 31,3 64 118 179 218 251 380 434 535 680 809 94 154 181 210 215 260 271 304 344 376 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 8,3 13,6 16,0 18,9 19,0 23,1 24,3 27,0 30,8 33,6 73 136 211 266 297 455 534 646 839 999 99 163 192 226 228 277 291 324 369 403 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 8,9 14,7 17,5 20,6 20,8 25,4 26,5 33,8 29,7 36,9 87 165 272 342 386 606 699 1121 862 1333 106 176 210 248 250 305 318 406 356 443 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 9,9 16,5 19,5 22,9 23,3 28,4 29,7 33,2 38,0 41,4 114 224 363 455 527 829 959 1183 1558 1850 118 198 234 275 280 341 356 398 456 496 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 Diameter over insulation Outer diameter approx (mm) (mm) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 7,5 12,3 14,7 17,1 17,5 21,2 22,1 24,5 28,0 30,5 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 20x2x1,5 15x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 Maximum DC resistance at 20 °C (Ω/km) Weight of cable approx (kg/km) TEPLA I - FR - O 500 V (XLPE/LS0H) RTE4OHM1 RTE4XOHM1 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 53 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - O (G4/PVC or G4/LS0H) 300 or 500 V Construction > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A IEC 60331 STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation silicon Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r 54 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331 TEPLA I - FR - O 300 V (G4/PVC or G4/LS0H) Type* Cross section Diameter of conductor (mm2) (mm) RG4OHM1-FR RG4XOHM1-FR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 RG4OHM1-FR RG4XOHM1-FR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 RG4OHM1-FR RG4XOHM1-FR RG4OHM1-FR RG4XOHM1-FR Min bending radius Capacitance L/R (mm) (pF/m) (µH/Ω) 55 116 157 192 213 319 363 439 569 666 74 120 140 164 166 201 209 232 264 286 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 6,4 10,4 12,2 14,3 14,5 17,5 18,2 20,4 23,1 25,2 60 128 175 215 240 362 413 511 651 775 77 125 146 172 174 210 219 245 277 302 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 11,2 13,3 15,5 15,6 18,9 19,9 22,1 25,2 27,3 71 151 217 259 291 443 518 630 819 961 83 134 160 185 187 227 239 265 302 327 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,7 12,5 14,8 17,2 17,4 21,3 22,2 24,8 28,3 30,6 91 195 286 345 387 603 694 858 1116 1312 92 150 178 207 209 255 266 298 339 367 250 250 250 250 250 250 250 250 250 250 40 40 40 40 40 40 40 40 40 40 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 8,4 14,1 16,8 19,5 19,9 24,2 25,3 28,3 32,2 35,2 116 259 387 465 538 839 968 1197 1558 1870 101 169 201 234 239 291 303 339 386 423 250 250 250 250 250 250 250 250 250 250 60 60 60 60 60 60 60 60 60 60 Diameter over insulation Outer diameter approx (mm) (mm) 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 10,0 11,7 13,7 13,8 16,7 17,4 19,3 22,0 23,8 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 Maximum DC resistance at 20 °C (Ω/km) Weight of cable approx (kg/km) TEPLA I - FR - O 500 V (G4/PVC or G4/LS0H) RG4OHM1-FR RG4XOHM1-FR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 * Refers only to G4/LS0H construction 55 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - OA (XLPE/SWA/LS0H) 300 or 500 V Construction > > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 2 Fire barrier mica/glass tape Insulation XLPE Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Armour galvanized steel wire Outer sheath LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties Low smoke emission low r 56 EC 60332-1 IEC 60332-3A IEC 60331 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331-23 TEPLA I - FR - OA 300 V (XLPE/SWA/LS0H) Type Cross section (mm2) Diameter Maximum DC of conductor resistance at 20 °C (Ω/km) (mm) Diameter over insulation (mm) Diameter Diameter of Diameter over armour over inner wires armour sheath (mm) (mm) (mm) Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) (kg/km) (mm) (pF/m) (µH/Ω) RTE4OHM1FM1 RTE4XOHM1FM1 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 7,4 12,3 14,7 17,1 17,4 21,1 22,0 24,5 27,9 30,5 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 9,2 14,1 16,5 18,9 19,2 22,9 23,8 27,0 30,4 33,0 12,0 17,0 19,4 21,8 22,4 26,1 27,2 30,2 33,9 36,4 276 480 582 675 727 942 1027 1352 1629 1828 167 238 272 305 313 365 380 423 474 510 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RTE4OHM1FM1 RTE4XOHM1FM1 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 7,84 12,8 15,0 17,5 17,9 21,6 22,6 25,3 28,6 31,3 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 9,6 14,6 16,8 19,3 19,7 23,4 25,1 27,8 31,1 33,8 12,3 17,5 19,8 22,2 22,8 26,8 28,3 31,0 34,6 37,4 292 504 606 703 758 1000 1240 1434 1715 1957 172 245 277 311 319 375 396 435 484 524 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RTE4OHM1FM1 RTE4XOHM1FM1 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 8,28 13,5 15,9 18,8 19,0 23,0 24,2 26,9 30,7 33,5 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 10,0 15,3 17,7 20,6 20,8 25,5 26,7 29,4 33,2 36,0 12,7 18,3 20,7 23,7 23,9 28,8 30,0 32,9 36,9 39,7 316 549 665 798 839 1279 1400 1622 1971 2230 178 256 290 332 335 403 419 460 516 555 150 150 150 150 150 150 150 150 150 150 25 25 25 25 25 25 25 25 25 25 RTE4OHM1FM1 RTE4XOHM1FM1 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 8,85 14,6 17,5 20,6 20,8 25,4 26,5 29,7 33,8 36,8 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 1,6 10,6 16,4 19,3 22,4 23,3 27,9 29,0 32,2 37,0 40,0 13,3 19,6 22,4 25,5 26,5 31,3 32,4 35,8 40,8 44,1 346 622 782 927 1140 1535 1660 1954 2631 2999 187 274 314 357 371 439 454 501 572 617 150 150 150 150 150 150 150 150 150 150 40 40 40 40 40 40 40 40 40 40 9,8 16,5 19,4 22,9 23,3 28,4 29,6 33,1 37,9 41,3 0,9 0,9 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2 11,6 18,3 21,9 25,4 25,8 31,6 32,8 36,3 41,1 45,3 14,5 21,4 25,3 28,8 29,2 35,4 36,7 40,4 45,4 49,8 406 741 1090 1297 1388 2103 2281 2691 3291 4118 203 300 354 403 409 496 513 565 635 697 150 150 150 150 150 150 150 150 150 150 60 60 60 60 60 60 60 60 60 60 TEPLA I - FR - OA 300 V (XLPE/SWA/LS0H) RTE4OHM1FM1 RTE4XOHM1FM1 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 57 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - OA (G4/SWA/PVC or G4/SWA/LS0H) 300 or 500 V Construction > > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A IEC 60331 STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation silicon Pairs twisted Identification pairs blue, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Inner sheath PVC or LS0H Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r 58 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD EXCELLENT LS0H -5 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331 TEPLA I - FR - OA 300 V (G4/SWA/PVC or G4/SWA/LS0H) Type* Cross section (mm2) Diameter Maximum Diameter DC of over conductor resistance insulation at 20 °C (Ω/km) (mm) (mm) Diameter over inner sheath (mm) Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius Capacitance L/R (mm) (mm) (mm) (kg/km) (mm) (pF/m) (µH/Ω) RG4OHM1FM1-FR RG4XOHM1FM1-FR 1x2x0,5 2x2x0,5 4x2x0,5 5x2x0,5 6x2x0,5 10x2x0,5 12x2x0,5 15x2x0,5 20x2x0,5 24x2x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,2 9,9 11,6 13,7 13,8 16,7 17,4 19,3 22,0 23,8 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 8 11,7 13,4 15,5 15,6 18,5 19,2 21,1 23,8 26,3 10,7 14,5 16,3 18,4 18,5 21,6 22,3 24,2 27,1 29,5 234 381 472 551 574 761 820 941 1146 1457 149 202 229 257 259 302 312 339 379 413 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 RG4OHM1FM1-FR RG4XOHM1FM1-FR 1x2x0,75 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 10x2x0,75 12x2x0,75 15x2x0,75 20x2x0,75 24x2x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 6,42 10,4 12,1 14,3 14,4 17,5 18,2 20,4 23,0 25,2 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 8,2 12,2 13,9 16,1 16,2 19,3 20,0 22,2 25,5 27,7 10,9 14,9 16,9 19,0 19,2 22,4 23,1 25,3 28,8 30,9 246 406 499 589 617 820 887 1037 1416 1606 153 208 236 266 268 313 324 354 403 433 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 RG4OHM1FM1-FR RG4XOHM1FM1-FR 1x2x1 2x2x1 4x2x1 5x2x1 6x2x1 10x2x1 12x2x1 15x2x1 20x2x1 24x2x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 6,9 11,1 13,3 15,4 15,6 18,8 19,8 22,0 25,1 27,2 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 8,7 12,9 15,1 17,2 17,4 20,6 21,6 24,5 27,6 29,7 11,3 15,9 18,0 20,1 20,3 23,8 24,8 27,8 30,9 33,2 265 452 569 662 695 937 1035 1368 1650 1879 158 222 252 282 284 333 347 389 432 464 250 250 250 250 250 250 250 250 250 250 25 25 25 25 25 25 25 25 25 25 RG4OHM1FM1-FR RG4XOHM1FM1-FR 1x2x1,5 2x2x1,5 4x2x1,5 5x2x1,5 6x2x1,5 10x2x1,5 12x2x1,5 15x2x1,5 20x2x1,5 24x2x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 7,67 12,4 14,8 17,2 17,4 21,2 22,1 24,8 28,2 30,6 0,9 0,9 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,25 9,4 14,2 16,6 19,0 19,2 23,7 24,6 27,3 30,7 33,1 12,1 17,2 19,7 22,1 22,3 27,0 28,1 30,7 34,4 36,7 305 526 683 794 844 1315 1446 1691 2072 2349 170 240 276 310 312 378 393 430 481 514 250 250 250 250 250 250 250 250 250 250 40 40 40 40 40 40 40 40 40 40 0,9 0,9 0,9 1,25 1,25 1,25 1,25 1,6 1,6 1,6 10,2 15,9 18,5 22,0 22,4 26,7 27,7 31,4 35,3 38,4 13,1 19,0 21,9 25,2 25,8 30,3 31,4 35,3 39,4 42,6 352 635 840 1124 1222 1672 1830 2380 2909 3353 183 266 306 353 361 425 439 494 551 597 250 250 250 250 250 250 250 250 250 250 60 60 60 60 60 60 60 60 60 60 TEPLA I - FR - OA 500 V (G4/SWA/PVC or G4/SWA/LS0H) RG4OHM1FM1-FR RG4XOHM1FM1-FR 1x2x2,5 2x2x2,5 4x2x2,5 5x2x2,5 6x2x2,5 10x2x2,5 12x2x2,5 15x2x2,5 20x2x2,5 24x2x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 8,4 14,1 16,7 19,5 19,9 24,2 25,2 28,2 32,1 35,2 * Refers only to G4/LS0H/SWA/LS0H construction 59 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - O (PE/PVC or XLPE/PVC or XLPE/LS0H) 300 or 500 V Construction > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation polyethylene or XLPE Triples twisted Identification triples blue, brown, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 60 GOOD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA I - O 300 V (PE/PVC or XLPE/PVC or XLPE/LS0H) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) RE4OHR RE4XOHR 1x3x0,5 2x3x0,5 6x3x0,5 10x3x0,5 12x3x0,5 15x3x0,5 20x3x0,5 24x3x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,5 10,9 15,7 18,6 20,2 22,4 25,5 27,9 54 101 226 345 402 497 636 760 78 131 189 223 242 269 306 335 RE4OHR RE4XOHR 1x3x0,75 2x3x0,75 6x3x0,75 10x3x0,75 12x3x0,75 15x3x0,75 20x3x0,75 24x3x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 6,8 11,4 16,5 19,5 21,3 23,5 27,0 29,3 60 113 259 399 476 576 753 885 82 136 198 234 256 282 324 352 RE4OHR RE4XOHR 1x3x1 2x3x1 6x3x1 10x3x1 12x3x1 15x3x1 20x3x1 24x3x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 7,4 12,4 18,0 21,2 23,1 25,7 29,4 32,2 74 142 330 510 598 739 967 1154 89 149 216 255 277 308 353 386 RE4OHR RE4XOHR 1x3x1,5 2x3x1,5 6x3x1,5 10x3x1,5 12x3x1,5 15x3x1,5 20x3x1,5 24x3x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 8,1 13,7 20,1 23,7 25,9 28,8 33,0 36,1 94 180 450 701 836 1033 1352 1612 97 164 241 284 311 346 396 433 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 9,1 15,7 22,9 27,2 29,5 33,0 37,7 41,2 127 254 639 1013 1192 1488 1949 2322 109 188 275 326 354 396 452 494 Type* TEPLA I - O 500 V (PE/PVC or XLPE/PVC or XLPE/LS0H) RE4OHR RE4XOHR 1x3x2,5 2x3x2,5 6x3x2,5 10x3x2,5 12x3x2,5 15x3x2,5 20x3x2,5 24x3x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 * Refers only to XLPE/PVC construction 61 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - O (XLPE/LS0H) 300 or 500 V Construction > > > > > > > > > Applicable standards Conductor annealed copper wires according to class 2 Fire barrier mica/glass tape Insulation XLPE Triples twisted Identification triples blue, brown, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) low r 62 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD GOOD LS0H 0 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331 TEPLA I - FR - O 300 V (XLPE/LS0H) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) RTE4OHM1 RTE4XOHM1 1x3x0,5 2x3x0,5 6x3x0,5 10x3x0,5 12x3x0,5 15x3x0,5 20x3x0,5 24x3x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 2,80 2,80 2,80 2,80 2,80 2,80 2,80 2,80 8,1 13,7 19,9 23,6 25,8 28,5 32,7 35,8 73 138 308 467 556 670 872 1039 97 165 239 283 310 342 393 430 RTE4OHM1 RTE4XOHM1 1x3x0,75 2x3x0,75 6x3x0,75 10x3x0,75 12x3x0,75 15x3x0,75 20x3x0,75 24x3x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,90 2,90 2,90 2,90 2,90 2,90 2,90 2,90 8,3 14,0 20,4 24,4 26,5 29,5 33,5 36,7 79 149 339 529 616 758 970 1156 99 168 245 292 318 353 402 441 RTE4OHM1 RTE4XOHM1 1x3x1 2x3x1 6x3x1 10x3x1 12x3x1 15x3x1 20x3x1 24x3x1 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 3,10 3,10 3,10 3,10 3,10 3,10 3,10 3,10 8,7 14,9 21,9 25,9 28,2 31,4 36,0 39,4 90 174 416 638 746 921 1202 1432 105 179 263 311 338 377 432 472 RTE4OHM1 RTE4XOHM1 1x3x1,5 2x3x1,5 6x3x1,5 10x3x1,5 12x3x1,5 15x3x1,5 20x3x1,5 24x3x1,5 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12, 12,1 12,1 12,1 12,1 12,1 12,1 12,1 3,40 3,40 3,40 3,40 3,40 3,40 3,40 3,40 9,4 16,3 24,0 28,6 31,0 34,5 39,5 43,2 111 223 543 853 1000 1232 1610 1916 113 196 288 343 372 414 474 519 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,80 3,80 3,80 3,80 3,80 3,80 3,80 3,80 10,4 18,1 26,9 31,9 34,7 38,7 44,3 48,6 147 294 744 1171 1375 1716 2240 2687 125 217 322 383 416 465 531 583 Type TEPLA I - FR - O 500 V (XLPE/LS0H) RTE4OHM1 RTE4XOHM1 1x3x2,5 2x3x2,5 6x3x2,5 10x3x2,5 12x3x2,5 15x3x2,5 20x3x2,5 24x3x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 63 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA I - FR - O (G4/PVC or G4/LS0H) 300 or 500 V Construction > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60331 IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A IEC 60331 STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation silicon Triples twisted Identification triples blue, brown, black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300 V EN 50288-7” or e. g. : “PRYSMIAN year - n x m x csa 500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Fire resistant Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r 64 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD GOOD LS0H 0 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331-23 TEPLA I - FR - O 300 V (G4/PVC or G4/LS0H) Type* Cross section Diameter of conductor (mm2) (mm) RG4OHM1-FR RG4XOHM1-FR 1x3x0,5 2x3x0,5 6x3x0,5 10x3x0,5 12x3x0,5 15x3x0,5 20x3x0,5 24x3x0,5 0,96 0,96 0,96 0,96 0,96 0,96 0,96 0,96 36,0 36,0 36,0 36,0 36,0 36,0 36,0 36,0 RG4OHM1-FR RG4XOHM1-FR 1x3x0,75 2x3x0,75 6x3x0,75 10x3x0,75 12x3x0,75 15x3x0,75 20x3x0,75 24x3x0,75 1,08 1,08 1,08 1,08 1,08 1,08 1,08 1,08 RG4OHM1-FR RG4XOHM1-FR 1x3x1 2x3x1 6x3x1 10x3x1 12x3x1 15x3x1 20x3x1 24x3x1 RG4OHM1-FR RG4XOHM1-FR 1x3x1,5 2x3x1,5 6x3x1,5 10x3x1,5 12x3x1,5 15x3x1,5 20x3x1,5 24x3x1,5 Maximum DC resistance at 20 °C (Ω/km) Diameter over insulation Min bending radius Outer diameter approx Weight of cable approx (mm) (kg/km) 2,16 2,16 2,16 2,16 2,16 2,16 2,16 2,16 6,5 10,9 15,7 18,6 20,2 22,4 25,5 27,9 64,8 143,8 284,8 430,6 501,2 617,1 790,8 943,1 78 131 189 223 242 269 306 335 24,5 24,5 24,5 24,5 24,5 24,5 24,5 24,5 2,28 2,28 2,28 2,28 2,28 2,28 2,28 2,28 6,8 11,4 16,5 19,5 21,3 23,5 27,0 29,3 72,5 159,9 323,2 492,0 584,1 707,5 922,4 1085,4 82 136 198 234 256 282 324 352 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 18,1 18,1 18,1 18,1 18,1 18,1 18,1 18,1 2,49 2,49 2,49 2,49 2,49 2,49 2,49 2,49 7,4 12,4 18,0 21,2 23,1 25,7 29,4 32,2 88,8 197,3 404,7 618,8 723,4 891,6 1163,5 1386,8 89 149 216 255 277 308 353 386 1,59 1,59 1,59 1,59 1,59 1,59 1,59 1,59 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 2,79 2,79 2,79 2,79 2,79 2,79 2,79 2,79 8,1 13,7 20,1 23,7 25,9 28,8 33,0 36,1 111,3 249,2 540,4 832,9 988,7 1218,2 1590,4 1894,9 97 164 241 284 311 346 396 433 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,18 3,18 3,18 3,18 3,18 3,18 3,18 3,18 9,1 15,7 22,9 27,2 29,5 33,0 25,6 27,9 149,1 342,2 753,3 1179,0 1383,7 1721,0 1656,7 1972,7 109 188 275 326 354 396 308 335 (mm) (mm) TEPLA I - FR - O 500 V (G4/PVC or G4/LS0H) RG4OHM1-FR RG4XOHM1-FR 1x3x2,5 2x3x2,5 6x3x2,5 10x3x2,5 12x3x2,5 15x3x2,5 20x3x2,5 24x3x2,5 1,98 1,98 1,98 1,98 1,98 1,98 1,98 1,98 * Refers only to G4/LS0H construction 65 TEPLA Plant & Petrochem Cables 66 technergy TM INTEGRATED CABLING SOLUTIONS Thermocouple cables 67 Thermocouple cables TEPLA Plant & Petrochem Cables Standards of extension & compensating cables for thermocouples (temperature ranges and tolerances of conductors, colour codes of insulations and outer sheaths) - platinum-10% rhodium platinum platinum-30% rhodium platinum-6% rhodium iron copper-nickel copper copper-nickel nickel-chromium copper-nickel nickel-chromium nickel > RCA/SCA copper/copper-nickel 0 °C up to +100 °C (class 2: ±30 µV / ±2,5 °C) > RCB/SCB copper/copper-nickel 0 °C up to +200 °C (class 2: ±60 µV / ±5 °C) + - > BC copper/copper 0 °C up to +100 °C (±40 µV / ±3,5 °C) + - > JX iron/copper-nickel -25 °C up to +200 °C (class 1: ±85 µV / ±1,5 °C) (class 2: ±140 µV / ±2,5 °C) > SX copper/copper-nickel 0 °C up to +200 C (±57 µV / ±5 °C) + - > BX copper-alloy/copper (copper/copper) 0 °C up to +100 °C (+0,0 µV / +0 °C) (-33 V / -3,7 °C) + - > JX iron/copper-nickel 0 °C up to +200 °C (special: ±1,1 °C) (standard: ±2,2 °C) + - > TX copper/copper-nickel -25 °C up to +100 °C (class 1: ±30 µV / ±0,5 °C) (class 2: ±60 µV / ±1,0 °C) + - > TX copper/copper-nickel 0 °C up to +100 °C (special: ±0,5 °C) (standard: ±1,0 °C) + - > EX nickel-chromium/copper-nickel -25 °C up to +200 °C (class 1: ±120 µV / ±1,5 °C) (class 2: ±200 µV / ±2,5 °C) + - > EX nickel-chromium/copper-nickel 0 °C up to +200 C (±17 °C) + - > KX nickel-chromium/nickel -25 °C up to +200 °C (class 1: ±60 µV / ±1,5 °C) (class 2: ±100 µV / ±2,5 °C) + - > KX nickel-chromium/nickel 0 °C up to +200 °C (±2,2 °C) + - > KCB copper/copper-nickel 0 °C up to +100 °C (class 2: ±100 µV / ±2,5 °C) > KCA iron/copper-nickel 0 °C up to +150 °C (class 2: ±100 µV / ±2,5 °C) + - + N - nickel-chromium-silicon nickel-silicon > NX nickel-chromium-silicon and nickel-silicon -25 °C up to +200 °C (class 1: ±60 µV / ±1,5 °C) (class 2: ±100 µV / ±2,5 °C) > NC copper/copper-nickel 0 °C up to +150 °C (class 2: ±100 µV / ±2,5 °C) 68 ANSI MC 96.1 ANSI MC 96.1 platinum-13% rhodium platinum IEC 60584 DIN IEC 60584 - + K - + E - + T - + J - + B + R S + Thermocouple type and material IEC 60584 DIN IEC 60584 + - > VX copper/copper-nickel ISARP 1.1 0 °C up to +100 °C (±2,2 °C) + - technergy TM INTEGRATED CABLING SOLUTIONS BPC BPX BNC BNX J IEC ANSI JPX JPX JNX JNX T IEC ANSI TPC TPX TNC TNX E IEC ANSI EPX EPX ENX ENX K IEC IEC IEC ANSI ISA KPX KPCA KPCB KPX VPX KNX KNCA KNCB KNX VNX N IEC IEC ANSI NPX NPC NPX NNX NNC NNX B IEC IEC ANSI Loop inductance (mH/km) (+) leg (-) leg 0,017 0,017 0,017 0,12 0,12 0,12 0,017 0,125 0,017 0,017 0,13 0,13 0,49 0,49 0,017 0,017 0,49 0,49 0,71 0,71 0,49 0,49 0,71 0,017 0,13 0,71 0,017 0,29 0,49 0,52 0,29 0,49 0,98 0,017 0,98 0,36 0,52 0,36 Loop inductance (mH/km) IEC ANSI R S Volume resistivity (Ω mm2/m) (-) leg RNCA/SNCA RNCA/SNCA SNX Code (+) leg RPCA/SPCA RPCB/SPCB SPX Standard Electrical characteristics (approx values) Volume resistivity (Ω•mm2 /m) Code Standard 1 1 1 1 1 8 8 1 1 3 3 3 1 8 3 1 3 1 3 69 TEPLA Plant & Petrochem cables 70 technergy TM INTEGRATED CABLING SOLUTIONS Thermocouple cables according to BS 5308 71 Thermocouple cables TEPLA Plant & Petrochem Cables TEPLA T - IO (PE/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor solid alloy conductor Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Identification pairs numbered pairs and colour code according to ANSI MC 96.1 or IEC 60584 Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x AWG 300/500 V thermocouple type” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 72 STANDARD GOOD LS0H -5 °C 12 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Thermocouple cables generally according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA T - IO 300/500 V (PE/PVC or XLPE/LS0H) Cross section Diameter of conductor Diameter over insulation Diameter over lay up Outer diameter approx Weight of cable approx Min bending radius (AWG) (mm) (mm) (mm) (mm) (kg/km) (mm) UEXHOHR 2x2x20 4x2x20 6x2x20 8x2x20 10x2x20 12x2x20 16x2x20 20x2x20 24x2x20 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,7 9,3 11,3 12,2 13,9 14,5 16,8 18,8 20,6 10,0 11,0 13,0 14,0 16,0 17,0 19,0 21,0 23,0 90 140 200 250 300 350 440 550 650 120 132 156 168 192 204 228 252 276 UEXHOHR 2x2x18 4x2x18 6x2x18 8x2x18 10x2x18 12x2x18 16x2x18 20x2x18 24x2x18 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 2,2 2,2 2,2 2,2 2,2 2,2 2,2 2,2 2,2 8,5 10,3 12,4 13,4 15,2 16,0 18,5 20,7 22,6 11,0 12,0 14,0 16,0 18,0 19,0 22,0 24,0 27,0 120 190 260 320 390 450 600 720 870 132 144 168 192 216 228 264 288 324 UEXHOHR 2x2x16 4x2x16 6x2x16 8x2x16 10x2x16 12x2x16 16x2x16 20x2x16 24x2x16 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 9,3 11,3 13,7 14,8 16,8 17,6 20,4 22,8 25,0 12,0 15,0 17,0 18,0 20,0 21,0 24,0 27,0 29,0 150 240 330 410 500 600 770 960 1120 144 180 204 216 240 252 288 324 348 Type* * Refers only to PE/PVC construction 73 Thermocouple cables TEPLA Plant & Petrochem Cables TEPLA T - IOA (PE/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > > > Applicable standards BS 5308-1 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD EXCELLENT 0 °C Conductor solid alloy conductor Insulation polyethylene type 03 according to BS 6234 or XLPE Pairs twisted Identification pairs numbered pairs and colour code according to ANSI MC 96.1 or IEC 60584 Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding polyethylene type 03 according to BS 6234 or LS0H thermoplastic compound Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 or hydrocarbon resistant or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x m x AWG 300/500 V thermocouple type” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3C 74 STANDARD EXCELLENT LS0H -6 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Thermocouple cables generally according to BS 5308-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA T - IOA 300/500 V (PE/SWA/PVC or XLPE/SWA/LS0H) Diameter of armour wires Diameter over armour Weight of cable approx Weight of cable approx Min bending radius (mm) Diameter over separation sheath (mm) (mm) (mm) (kg/km) (kg/km) (mm) 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,7 9,3 11,3 12,2 13,9 14,5 16,8 18,8 20,6 9,5 11,0 13,0 14,0 15,5 16,2 18,2 20,5 22,0 0,9 0,9 1,3 1,3 1,3 1,3 1,6 1,6 1,6 11,3 12,8 15,5 16,5 18,0 18,7 21,4 23,7 25,2 13,9 15,4 18,5 19,5 21,2 21,9 24,8 27,3 28,8 350 440 640 720 810 890 1200 1400 1550 195 216 259 273 297 307 347 382 403 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 2,2 2,2 2,2 2,2 2,2 2,2 2,2 2,2 2,2 8,5 10,3 12,4 13,4 15,2 16,0 18,5 20,7 22,6 10,8 12,8 15,2 16,2 18,0 18,8 21,7 24,0 26,3 0,9 1,3 1,3 1,3 1,6 1,6 1,6 1,6 1,6 12,6 15,3 17,7 18,7 21,2 22,0 24,9 27,2 29,5 15,2 18,3 20,9 21,9 24,6 21,9 24,8 27,3 33,5 410 630 770 870 1130 1220 1480 1700 1950 213 256 293 307 344 195 195 195 469 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 1,3 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 9,3 11,3 13,7 14,8 16,8 17,6 20,4 22,8 25,0 12,0 14,2 16,6 17,7 19,8 21,0 23,8 26,7 28,8 0,9 1,3 1,3 1,6 1,6 1,6 1,6 1,6 2,0 13,8 16,7 19,1 20,9 23,0 24,2 27,0 29,9 32,8 16,6 19,7 22,3 19,5 26,6 27,8 30,8 33,9 36,8 460 720 890 1130 1310 1450 1750 2030 2530 232 276 312 195 372 389 431 475 515 Cross section Diameter of conductor Diameter over insulation Diameter over lay up (AWG) (mm) (mm) UEXHOHRFR 2x2x20 4x2x20 6x2x20 8x2x20 10x2x20 12x2x20 16x2x20 20x2x20 24x2x20 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 UEXHOHRFR 2x2x18 4x2x18 6x2x18 8x2x18 10x2x18 12x2x18 16x2x18 20x2x18 24x2x18 UEXHOHRFR 2x2x16 4x2x16 6x2x16 8x2x16 10x2x16 12x2x16 16x2x16 20x2x16 24x2x16 Type* * Refers only to PE/SWA/PVC construction 75 TEPLA Plant & Petrochem Cables 76 technergy TM INTEGRATED CABLING SOLUTIONS Thermocouple cables according to EN 50288 77 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA T - IO (PE/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD GOOD 0 °C Conductor solid alloy Insulation polyethylene or XLPE Pairs twisted Identification pairs according to ANSI MC 96.1 or IEC 60584 Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 78 STANDARD GOOD LS0H -5 °C 12 D Pb technergy > Instrumentation cables generally according to EN 50288-7 TM INTEGRATED CABLING SOLUTIONS > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA T - IO 300/500 V (PE/PVC or XLPE/LS0H) Type* Cross section Diameter of conductor Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (mm) (kg/km) (mm) UEOHR UEXHOHR 1x2x20 2x2x20 4x2x20 6x2x20 8x2x20 10x2x20 12x2x20 16x2x20 20x2x20 24x2x20 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 5,1 7,7 8,9 10,6 11,9 13,6 14,0 15,6 17,4 19,4 51 100 150 220 260 320 360 480 580 690 61 93 107 128 143 163 168 187 209 233 UEOHR UEXHOHR 1x2x18 2x2x18 4x2x18 6x2x18 8x2x18 10x2x18 12x2x18 16x2x18 20x2x18 24x2x18 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 5,8 8,9 10,3 12,4 13,9 15,9 16,4 18,3 20,5 22,8 63 140 200 280 350 430 490 630 790 930 69 106 124 148 167 190 197 220 246 274 UEOHR UEXHOHR 1x2x16 2x2x16 4x2x16 6x2x16 8x2x16 10x2x16 12x2x16 16x2x16 20x2x16 24x2x16 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 6,8 10,7 12,6 15,1 17,1 19,5 20,3 22,6 25,4 28,4 60 180 270 360 460 560 640 860 1040 1250 82 129 151 182 205 235 243 272 305 341 * Refers only to PE/PVC construction 79 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA T - IOA (PE/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3A STANDARD EXCELLENT 0 °C Conductor solid alloy Insulation polyethylene or XLPE Pairs twisted Identification pairs according to ANSI MC 96.1 or IEC 60584 Individual screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Inner sheath PVC or LS0H Armour galvanized steel wire Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D PVC LS0H low r IEC 60332-1 IEC 60332-3A 80 STANDARD EXCELLENT LS0H -6 °C 14 D Pb technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA T - IOA 300/500 V (PE/SWA/PVC or XLPE/SWA/LS0H) Cross section Diameter of conductor (mm2) (mm) Diameter over inner sheath (mm) UEOHRFR UEXHOHRFR 1x2x20 2x2x20 4x2x20 6x2x20 8x2x20 10x2x20 12x2x20 16x2x20 20x2x20 24x2x20 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 0,81 5,1 7,7 8,9 10,6 11,9 13,6 14,0 15,6 17,4 19,4 UEOHRFR UEXHOHRFR 1x2x18 2x2x18 4x2x18 6x2x18 8x2x18 10x2x18 12x2x18 16x2x18 20x2x18 24x2x18 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 1,02 UEOHRFR UEXHOHRFR 1x2x16 2x2x16 4x2x16 6x2x16 8x2x16 10x2x16 12x2x16 16x2x16 20x2x16 24x2x16 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 1,29 Type* Diameter over armour Outer diameter approx (mm) (mm) 0,90 0,90 0,90 0,90 0,90 0,90 0,90 1,25 1,25 1,25 6,92 9,52 10,74 12,44 13,75 15,36 15,82 18,10 19,94 21,89 9,5 12,3 13,5 15,3 16,7 18,4 18,9 21,3 23,3 25,3 217 369 451 666 739 841 901 1302 1482 1647 133 172 190 215 234 258 265 298 326 354 5,8 8,9 10,3 12,4 13,9 15,9 16,4 18,3 20,5 22,8 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 8,26 11,37 12,84 14,86 16,44 18,36 18,92 20,81 23,01 25,35 10,9 14,2 15,8 17,9 19,6 21,6 22,2 24,2 26,5 29,0 252 423 652 787 876 1230 1327 1572 1852 2074 153 199 221 251 274 302 310 338 371 406 6,8 10,7 12,6 15,1 17,1 19,5 20,3 22,6 25,4 28,4 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,60 1,60 9,30 13,21 15,07 17,63 19,62 22,05 22,75 25,14 28,62 31,58 12,0 16,2 18,1 20,8 22,9 25,5 26,2 28,7 32,4 35,5 283 473 742 911 1189 1452 1496 1915 2092 2663 168 226 254 291 321 357 367 402 454 498 Diameter of armour wires (mm) Weight of cable approx (kg/km) Min bending radius (mm) * Refers only to PE/SWA/PVC construction 81 TEPLA Plant & Petrochem Cables 82 technergy TM INTEGRATED CABLING SOLUTIONS Control cables according to BS 5308 83 Control cables TEPLA Plant & Petrochem Cables TEPLA C - S (PVC/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > Applicable standards BS 5308 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 or XLPE Identification cores black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D low r IEC 60332-1 IEC 60332-3C 84 STANDARD GOOD LS0H -5 °C 12 D 70°C 160°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Control cables generally according to BS 5308 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA C - S 300/500 V (PVC/PVC or XLPE/LS0H) Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius (AWG) (mm) (mm) (mm) (mm) (kg/km) (mm) FROHR 2x0,5 3x0,5 4x0,5 6x0,5 10x0,5 20x0,5 0,9 0,9 0,9 0,9 0,9 0,9 39,00 39,00 39,00 39,00 39,00 39,00 2,1 2,1 2,1 2,1 2,1 2,1 5,9 6,2 6,7 8,1 10,6 13,5 46 56 67 100 152 276 71 74 80 97 127 162 FROHR 2x0,75 3x0,75 4x0,75 6x0,75 10x0,75 20x0,75 1,1 1,1 1,1 1,1 1,1 1,1 26,00 26,00 26,00 26,00 26,00 26,00 2,3 2,3 2,3 2,3 2,3 2,3 6,3 6,6 7,2 8,8 11,4 14,6 53 66 81 123 186 341 76 79 86 106 137 175 RROHR 2x1,5 3x1,5 4x1,5 6x1,5 10x1,5 20x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,10 12,10 12,10 12,10 12,10 12,10 2,8 2,8 2,8 2,8 2,8 2,8 7,3 8,0 8,7 10,7 13,7 17,6 77 105 130 204 303 569 88 96 104 128 164 211 Type* * Refers only to PVC/PVC construction 85 Control cables TEPLA Plant & Petrochem Cables TEPLA C - SA (PVC/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > Applicable standards BS 5308 IEC 60332-1 IEC 60332-3C IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 1 or 2 or 5 of BS 6360 Insulation PVC type TI1 according to BS 6746 or XLPE Identification cores black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Bedding PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Armour galvanized steel wire Outer sheath PVC type TM1 according to BS 6746 or LS0H thermoplastic compound Marking e. g. : “PRYSMIAN year - n x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN Afumex year - n x csa 300/500 V BS 5308” Design guidelines Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 86 STANDARD GOOD LS0H -5 °C 14 D 70°C 160°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Control cables generally according to BS 5308 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA C - SA 300/500 V (PVC/SWA/PVC or XLPE/SWA/LS0H) Type* Cross section Diameter of Maximum DC conductor resistance at 20 °C Diameter over insulation Diameter over inner sheath Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) FROHRFR 2x0,5 3x0,5 4x0,5 6x0,5 10x0,5 20x0,5 0,9 0,9 0,9 0,9 0,9 0,9 39,00 39,00 39,00 39,00 39,00 39,00 2,1 2,1 2,1 2,1 2,1 2,1 5,9 6,2 6,7 8,1 10,6 13,5 0,9 0,9 0,9 0,9 0,9 1,3 7,7 8,0 8,5 9,9 12,4 16,0 10,3 10,6 11,1 12,7 15,4 19,2 217 235 255 330 446 759 144 148 155 178 216 269 FROHRFR 2x0,75 3x0,75 4x0,75 6x0,75 10x0,75 20x0,75 1,1 1,1 1,1 1,1 1,1 1,1 26,00 26,00 26,00 26,00 26,00 26,00 2,3 2,3 2,3 2,3 2,3 2,3 6,3 6,6 7,2 8,8 11,4 14,6 0,9 0,9 0,9 0,9 0,9 1,3 8,1 8,4 9,0 10,6 13,2 17,1 10,7 11,0 11,8 13,4 16,2 20,3 233 254 289 369 502 854 150 154 165 188 227 284 RROHRFR 2x1,5 3x1,5 4x1,5 6x1,5 10x1,5 20x1,5 1,6 1,6 1,6 1,6 1,6 1,6 12,10 12,10 12,10 12,10 12,10 12,10 2,8 2,8 2,8 2,8 2,8 2,8 7,3 8,0 8,7 10,7 13,7 17,6 0,9 0,9 0,9 0,9 1,3 1,6 9,1 9,8 10,5 12,5 16,2 20,8 11,9 12,6 13,3 15,3 19,4 24,2 286 329 369 496 788 1320 167 176 186 214 272 339 * Refers only to PVC/SWA/PVC construction 87 Control cables TEPLA Plant & Petrochem Cables TEPLA C (XLPE/PVC or XLPE/LS0H) 0,6/1 kV Construction > > > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD GOOD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Identification cores black numbered Assembly concentric layers Penetrant. sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 0,6/1 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables(if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D low r IEC 60332-1 IEC 60332-3C 88 GOOD GOOD LS0H -5 °C 12 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Control cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA C 0,6/1 kV (XLPE/PVC or XLPE/LS0H) Type* RE4OR/RE4OM1 RE4OR/RE4OM1 RE4OR/RE4OM1 Voltage Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius Phase reactance at 50 Hz approx (*) Conductor short circuit current for 1 sec Current rating in air at 30 °C (kV) (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr. therm.res. 1 Km/W; depth of laying 0,8 m) (A) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 33x1,5 37x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 12,6 15,6 16,1 16,8 17,7 18,6 21,6 22,0 22,8 23,7 24,6 250 340 380 430 480 550 660 730 790 880 970 150 185 195 200 210 225 260 265 275 285 295 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,25 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 17 16 15 14 13 12 12 11 10 9,0 8,0 22 20 18 17 16 15 13 12 11 10 9 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 33x2,5 37x2,5 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 13,8 17,2 17,7 18,6 19,5 20,5 23,9 24,4 25,3 26,3 27,3 330 440 500 570 640 740 900 990 1080 1200 1320 165 205 210 225 235 245 285 295 305 315 330 0,094 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,41 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 23 21 20 18 18 17 16 15 14 13 12 29 26 24 22 21 19 18 17 16 15 14 ( ) * two adiacent cores 89 Control cables TEPLA Plant & Petrochem Cables TEPLA C - A (XLPE/SWA/PVC or XLPE/SWA/LS0H) 0,6/1 kV Construction > > > > > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Identification cores black numbered Assembly concentric layers Fillers non hygroscopic compound or LS0H non hygroscopic compound Armour galvanized steel wire Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 0,6/1 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables(if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 90 GOOD EXCELLENT LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Control cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA C - A 0,6/1 kV (XLPE/SWA/PVC or XLPE/SWA/LS0H) Type* RE4OFR/RE4OFM1 Phase Conductor Current Current Min rating in rating bending reactance short ground at at 50 Hz circuit in air radius 20 °C approx (*) current at 30 °C (gr.therm. for 1 sec res. 1 Km/W; depth of laying 0,8 m) (A) (Ω/km) (kA) (A) (kg/km) (mm) Voltage Cross Diameter Maximum Diameter Diameter Diameter Diameter Outer Weight DC of section over of over diameter of over conductor resistance insulation extruded armour armour approx cable at 20 °C approx inner wires covering/ taping (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 33x1,5 37x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0 11,0 14,0 14,5 15,2 16,1 17,0 20,0 20,4 21,2 22,1 23,0 0,8 1,25 1,25 1,25 1,25 1,25 1,6 1,6 1,6 1,6 1,6 12,6 16,5 17,0 17,7 18,6 19,5 23,2 23,6 24,4 25,3 26,2 16,2 20,1 20,6 21,3 22,2 23,1 26,8 27,2 28,0 28,9 29,8 490 770 830 890 970 1050 1400 1480 1560 1690 1790 225 280 290 300 310 325 375 380 390 405 415 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 17 16 15 14 13 12 12 11 10 9 8 22 20 18 17 16 15 13 12 11 10 9 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 33x2,5 37x2,5 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 3,4 12,2 15,6 16,1 17,0 17,9 18,9 22,3 22,8 23,7 24,7 25,7 1,25 1,25 1,25 1,25 1,6 1,6 1,6 1,6 1,6 1,6 1,6 14,7 18,1 18,6 19,5 21,1 22,1 25,5 26,0 26,9 27,9 28,9 18,3 21,7 22,2 23,1 24,7 25,7 29,1 29,6 30,7 31,7 32,7 710 910 990 1070 1320 1430 1710 1820 1960 2100 2250 255 305 310 325 345 360 405 415 430 445 460 0,094 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,09 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 23 21 20 18 18 17 16 15 14 13 12 29 26 24 22 21 19 18 17 16 15 14 ( ) * two adiacent cores 91 Control cables TEPLA Plant & Petrochem Cables TEPLA C - FR (XLPE/LS0H) 0,6/1 kV Construction > > > > > > > > > Applicable standards IEC IEC IEC IEC IEC IEC Conductor annealed copper wires according to class 2 of IEC 60228 Fire barrier mica/glass tape Insulation XLPE according to IEC 60502 Identification cores black numbered Assembly concentric layers Identification cores black numbered Assembly concentric layers Outer sheath LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN Afumex year - n x csa 0,6/ 1 kV IEC 60331” 60502 60332-1 60332-3A 60331 60754 61034 Design guidelines Flame retardant Fire retardant on bunched cables (if required) Fire resistant test Halogen free properties Low smoke emission low r 92 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD GOOD LS0H -5 °C 12 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Control fire resistant cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331 TEPLA C - FR 0,6/1 kV (XLPE/LS0H) Cross section Type* Diameter Maximum DC of conductor resistance at 20 °C Diameter over insulation Nominal thickness of outer sheath Outer diameter approx Diameter over armour Weight of cable approx Min bending radius Phase reactance at 50 Hz approx (*) Conductor short circuit current for 1 sec Current rating in air at 30 °C (mm) (Ω/km) (mm) (mm) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 16x1,5 19x1,5 RTE4OM1-FR 24x1,5 27x1,5 30x1,5 33x1,5 37x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 10,7 11,2 12,2 13,2 14,2 17,8 18,3 19,2 20,2 21,2 24,8 25,3 26,2 27,3 28,5 120 150 180 210 260 360 410 460 510 590 730 803 880 950 1060 128 134 146 158 170 214 220 230 242 254 298 304 314 328 342 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 28 23 23 23 17 16 15 14 13 12 12 11 10 9 8 37 31 31 29 22 20 18 17 16 15 13 12 11 10 9 RTE4OM1-FR 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,9 1,9 11,2 11,8 12,8 14,0 15,1 18,9 19,5 20,4 21,6 22,7 26,5 27,1 28,1 29,4 30,5 140 180 220 250 330 450 520 590 660 760 950 1040 1150 1260 1300 135 142 154 168 181 227 233 245 259 272 318 325 337 353 366 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 37 31 31 31 23 21 20 18 18 17 16 15 14 13 12 49 41 41 37 29 26 24 22 21 19 18 17 16 15 14 (mm2) RTE4OM1-FR 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 33x2,5 37x2,5 ( ) * two adiacent cores 93 Control cables TEPLA Plant & Petrochem Cables TEPLA C - FR - A (XLPE/SWA/LS0H) 0,6/1 kV Construction > > > > > > > > > Applicable standards IEC IEC IEC IEC IEC IEC Conductor annealed copper wires according to class 2 of IEC 60228 Fire barrier mica/glass tape Insulation XLPE according to IEC 60502 Identification cores black numbered Assembly concentric layers Separation sheath LS0H thermoplastic compound ST8 quality Armour galvanized steel wire Outer sheath LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN Afumex year - n x csa 0,6/ 1 kV IEC 60331” 60502 60332-1 60332-3A 60331 60754 61034 Design guidelines Flame retardant Fire retardant on bunched cables (if required) Fire resistant test Halogen free properties Low smoke emission low r 94 IEC 60332-1 IEC 60332-3A IEC 60331 GOOD EXCELLENT LS0H -5 °C 14 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Control fire resistant cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A > Fire resistant cables according to IEC 60331 TEPLA C - FR - A 0,6/1 kV (XLPE/SWA/LS0H) Phase Conductor Current Current Cross Diameter Maximum Nominal Diameter Inner Diameter Diameter Diameter Nominal Outer Weight Min DC insulation over sheath over of over thickness diameter of cable bending reactance short rating rating in section of armour armour of approx approx radius at 50 Hz circuit in air ground at conductor resistance thickness insulation thickness inner at 20 °C approx (*) current at 30 °C 20 °C (gr. sheath wires outer sheath for 1 sec therm.res. 1 Km/W; depth of laying 0,8 m) 2 (Ω/km) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) (mm ) (mm) (A) Type* RTE4OFM1-FR 2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 12x1,5 14x1,5 RTE4OFM1-FR16x1,5 19x1,5 24x1,5 27x1,5 30x1,5 33x1,5 37x1,5 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 12,1 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 9,0 9,6 10,5 11,6 12,6 16,1 16,6 17,5 18,5 19,6 23,1 23,6 24,6 25,6 26,6 0,8 0,8 0,8 1,3 1,3 1,6 1,6 1,6 1,6 1,6 1,6 1,6 1,6 2,0 2,0 10,6 11,2 12,1 14,1 15,1 19,3 19,8 20,7 21,7 22,8 26,3 26,8 27,8 29,6 30,6 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,9 1,9 2,0 2,0 2,0 14,2 14,8 15,7 17,7 18,7 22,9 23,4 24,3 25,3 26,4 30,1 30,6 31,8 33,6 34,6 350 380 510 590 680 1000 1080 1150 1250 1360 1630 1720 1830 2180 2350 199 207 220 247 261 320 328 341 355 370 422 429 445 470 485 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,11 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 28 23 23 23 17 16 15 14 13 12 12 11 10 9 8 37 31 31 31 22 20 18 17 16 15 13 12 11 10 9 RTE4OFM1-FR 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 10x2,5 12x2,5 14x2,5 16x2,5 19x2,5 24x2,5 27x2,5 30x2,5 33x2,5 37x2,5 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 7,41 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 0,7 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 3,8 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,2 1,2 9,6 10,2 11,2 12,4 13,5 17,3 17,9 18,8 20,0 21,1 24,9 25,5 26,5 28,0 29,1 0,8 0,8 1,3 1,3 1,3 1,6 1,6 1,6 1,6 1,6 1,6 2,0 2,0 2,0 2,0 11,2 11,8 13,7 14,9 16,0 20,5 21,1 22,0 23,2 24,3 28,1 29,5 30,5 32,0 33,1 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 2,0 2,0 2,0 2,1 2,1 14,8 15,4 17,3 18,5 19,6 24,1 24,7 25,6 26,8 27,9 32,1 33,5 34,5 36,2 37,3 380 520 600 670 780 1140 1230 1310 1430 1580 1920 2250 2400 2600 2750 208 216 242 259 274 337 345 359 375 391 450 469 483 507 523 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 37 31 31 31 23 21 20 18 18 17 16 15 14 13 12 49 41 41 37 29 26 24 22 21 19 18 17 16 15 14 ( ) * two adiacent cores 95 TEPLA Plant & Petrochem Cables 96 technergy TM INTEGRATED CABLING SOLUTIONS Control cables according to EN 50288 97 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA C - S (PVC/PVC or XLPE/LS0H) 300/500 V Construction > > > > > > > Applicable standards EN 50288-7 EN 50290-2 HD 383 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation PVC or XLPE Identification cores black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x csa 300/500 V BS 5308” or e. g. : “PRYSMIAN year - n x csa 300/500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D low r IEC 60332-1 IEC 60332-3C 98 STANDARD GOOD LS0H -5 °C 12 D 70°C 160°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA C - S 300/500 V (PVC/PVC or XLPE/LS0H) Type* RE4OHM1* Diameter over insulation Outer diameter approx (mm) Maximum DC resistance at 20 °C (Ω/km) (mm) (mm) 0,96 0,96 0,96 0,96 0,96 0,96 1,08 1,08 1,08 1,08 1,08 1,08 1,29 1,29 1,29 1,29 1,29 1,29 36,0 36,0 36,0 36,0 36,0 36,0 24,5 24,5 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1 18,1 18,1 2,16 2,16 2,16 2,16 2,16 2,16 2,28 2,28 2,28 2,28 2,28 2,28 2,49 2,49 2,49 2,49 2,49 2,49 6,6 7,0 7,6 9,2 11,9 16,4 6,9 7,2 8,1 9,5 12,6 17,3 8,1 8,5 9,3 11,2 14,9 20,6 Cross section Diameter of conductor (mm2) 2x0,5 3x0,5 4x0,5 7x0,5 12x0,5 24x0,5 2x0,75 3x0,75 4x0,75 7x0,75 12x0,75 24x0,75 2x1,5 3x1,5 4x1,5 7x1,5 12x1,5 24x1,5 Weight of cable approx (kg/km) 57 66 76 114 173 308 62 72 89 128 201 361 92 110 134 205 329 605 Min bending radius (mm) 80 84 91 110 142 197 82 87 97 114 151 208 97 102 112 135 178 247 * or RROHR 99 Instrumentation cables TEPLA Plant & Petrochem Cables TEPLA C - SA (PVC/SWA/PVC or XLPE/SWA/LS0H) 300/500 V Construction > > > > > > > > > Applicable standards EN 50288-7 EN 50290-2 HD 383 IEC 60332-1 IEC 60332-3A IEC 60754 IEC 61034 r IEC 60332-1 IEC 60332-3C STANDARD GOOD 0 °C Conductor annealed copper wires according to class 2 Insulation PVC or XLPE Identification cores black numbered Assembly concentric layers Overall screen aluminium/polyester tape 0,024 mm in electrical contact with tinned annealed copper wires of a total section of 0,5 mm2 polyester tape 0,023 mm Inner sheath PVC or LS0H Armour galvanized steel wire comply with EN 10244 classe D Outer sheath PVC or LS0H Marking e. g. : “PRYSMIAN year - n x m x csa 300/500 V EN 50288-7” Design guidelines Specification for insulation and sheath material Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 100 STANDARD GOOD LS0H -5 °C 14 D 70°C 160°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Instrumentation cables generally according to EN 50288-7 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3A TEPLA C - SA 300/500 V (PVC/SWA/PVC or XLPE/SWA/LS0H) Type* RE4OHM1FM1* Diameter over insulation (mm) Maximum DC resistance at 20 °C (Ω/km) 0,96 0,96 0,96 0,96 0,96 0,96 1,08 1,08 1,08 1,08 1,08 1,08 1,29 1,29 1,29 1,29 1,29 1,29 36,0 36,0 36,0 36,0 36,0 36,0 24,5 24,5 24,5 24,5 24,5 24,5 18,1 18,1 18,1 18,1 18,1 18,1 Cross section Diameter of conductor (mm2) 2x0,5 3x0,5 4x0,5 7x0,5 12x0,5 24x0,5 2x0,75 3x0,75 4x0,75 7x0,75 12x0,75 24x0,75 2x1,5 3x1,5 4x1,5 7x1,5 12x1,5 24x1,5 Diameter of armour wires Diameter over armour Outer diameter approx Weight of cable approx Min bending radius (mm) Diameter over inner sheath (mm) (mm) (mm) (mm) (kg/km) (mm) 2,16 2,16 2,16 2,16 2,16 2,16 2,28 2,28 2,28 2,28 2,28 2,28 2,49 2,49 2,49 2,49 2,49 2,49 6,6 6,9 7,5 9,1 11,8 16,4 6,8 7,2 8,0 9,5 12,5 17,3 8,0 8,5 9,3 11,2 14,8 20,6 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 1,25 8,4 8,7 9,3 10,9 13,6 18,2 8,6 9,0 9,8 11,3 14,3 19,1 9,8 10,3 11,1 13,0 16,6 23,1 10,5 10,8 11,4 13,0 15,9 20,7 10,7 11,1 11,9 13,4 16,6 21,6 11,9 12,4 13,4 15,3 19,2 25,9 229 249 268 344 466 713 240 257 293 366 508 787 296 322 371 484 698 1286 146 151 160 182 223 290 150 155 167 187 233 303 167 173 187 214 268 363 * or RROHRFR 101 TEPLA Plant & Petrochem Cables 102 technergy TM INTEGRATED CABLING SOLUTIONS Communication cables 103 Communication cables TEPLA Plant & Petrochem Cables TEPLA COM - S IBM STANDARD MIL C 17 Construction > > > > > > Applicable standards 104 Conductor solid or stranded plain copper wire according to MIL C 17 Insulation polyethylene or polyethylene/air Outer conductor tinned or plain copper braid Fillers halogen free non hygroscopic compound Sheath non contaminating PVC compound, black colour Marking e. g. : “M17... RG... PRYSMIAN” Coaxial cables with solid insulation or semiair spaced (mose + spiral in polyethylene tube) for data network, used in radio frequency and power transmission technergy TM INTEGRATED CABLING SOLUTIONS > RG coaxial cables > Cable for high frequency and data transmission TEPLA COM - S MIL C 17, IBM STANDARD Type Inner conductor type MG17/155RG58 (RG58C/U) M17/136RG213 (RG213/U) M17/29RG59 (RG59B/U) 2RG59B/U M17/6RG11 (RG11A/U) M17/30RG62 (RG62A/U) RX93 TWINAX P/N IBM 7362211 Legend R: Plain copper RS 19x0,18 R 7x0,7 CW SOLID R SOLID RS 7x0,44 CW SOLID RS R 7x0,3 RS 7x0,3 Insulation Outer conductor type Outer diameter nominal Cable weight Impedance nominal value Max capac. Velocity ratio Attenuation at 400 MHz (mm) (kg/km) (Ω) (pF/m) (%) (max dB/100 m) nominal diameter (mm) type 0,9 PE 3,0 RS 5,0 40 50 100 66 49,2 2,25 PE 7,3 R 10,3 150 50 100 66 6,1 0,58 PE 7,3 R 6,2 54 75 67 66 29,5 0,58 PE 3,7 R 6,2x12,3 110 75 67 66 24,6 1,2 PE 7,3 R 10,3 136 75 67 66 17,0 0,64 PE/A 3,8 R 6,2 53 93 43 83 26,3 0.4 0,97 PE/A PE 2,4 2,2 RS RS 3,9 8,4 24 85 93 100 43 51 83 66 28,0 14,8 RS: Tinned copper nominal diameter (mm) CW: Copperweld 105 TEPLA Plant & Petrochem Cables 106 technergy TM INTEGRATED CABLING SOLUTIONS Power cables Low Voltage & Earthing cables 107 Earthing cables TEPLA Plant & Petrochem Cables TEPLA E (PVC) 0,45/0,75 kV Construction > > > Applicable standards CENELEC HD 21 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant IEC 60332-3A Fire retardant on bunched cables (if required) IEC 60227/03 Design and tests guidelines r IEC 60332-1 IEC 60332-3A 108 STANDARD GOOD 0 °C Conductor bare copper circular flexible, according to class 5 of IEC 60228 Insulation PVC compound Marking e. g. : “PRYSMIAN year - n x csa 0,45/0,75 kV” 4D Pb 70°C 160°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Earthing cables according to CENELEC HD 21 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA E 0,45/0,75 kV (PVC) Type N07V-K Voltage Cross section Diameter of conductor Maximum DC resistance at 20 °C Outer diameter approx Weight of cable approx Min bending radius Current rating in air at 30 °C (kV) (mm2) (mm) (Ω/km) (mm) (kg/km) (mm) (A) 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 0,45/0,75 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 1,3 1,5 1,9 2,5 3,0 3,9 5,0 6,5 7,6 9,3 11,0 12,5 15,4 16,5 18,3 21,5 19,5 13,3 7,98 4,95 3,30 1,91 1,21 0,780 0,554 0,386 0,272 0,206 0,161 0,129 0,106 0,0801 3,2 3,5 4,2 4,8 6,3 7,6 8,8 11,0 12,5 14,5 17,0 19,0 21,0 23,5 26,0 29,5 14 19 30 45 63 100 160 260 350 490 670 890 1200 1400 1800 2400 13 14 17 19 25 30 35 45 50 60 70 80 85 95 100 120 12 16 21 28 36 50 68 89 110 134 171 207 239 275 314 369 109 Power cables TEPLA Plant & Petrochem Cables TEPLA L (XLPE/PVC or XLPE/LS0H) single core 0,6/1 kV Construction > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD GOOD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 0,6/1 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables(if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D low r EC 60332-1 IEC 60332-3C 110 GOOD GOOD LS0H -5 °C 12 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA L 0,6/1 kV (XLPE/PVC or XLPE/LS0H) - single core Type* RE4M1/RE4R Voltage Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter over insulation Outer diameter approx Weight of cable approx Min bending radius Phase reactance at 50 Hz approx (*) Conductor short circuit current for 1 sec Current rating in air at 30 °C (kV) (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr. therm.res. 1 Km/W; depth of laying 0,8 m) (A) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 21,9 24,2 27,0 30,7 34,8 5,8 6,2 6,8 7,3 8,1 9,1 10,7 11,8 13 14,9 16,7 18,5 20,5 22,3 25,5 27,9 31,0 34,8 39,4 50 60 80 110 150 210 310 400 520 720 980 1220 1490 1840 2380 3000 3800 4870 6300 70 75 80 90 100 110 130 140 155 180 200 220 245 270 305 335 370 420 465 0,14 0,13 0,12 0,11 0,11 0,10 0,10 0,09 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 57,8 72,2 90,9 25 33 44 56 77 101 137 167 205 261 323 378 435 504 603 698 811 947 1095 35 46 59 74 97 125 161 192 227 278 333 379 424 478 553 623 703 794 889 ( ) * trefoil formation 111 Power cables TEPLA Plant & Petrochem Cables TEPLA L - A (XLPE/AWA/PVC or XLPE/AWA/LS0H) single core 0,6/1 kV Construction > > > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Bedding non hygroscopic compound or LS0H non hygroscopic compound Armour aluminium wires Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN - n x csa 0,6/1” or e. g. : “PRYSMIAN Afumex year - n x csa 0,6/1 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 112 GOOD EXCELLENT LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA L - A 0,6/1 kV (XLPE/AWA/PVC or XLPE/AWA/LS0H) - single core Type* Voltage (kV) RE4FM1/RE4FR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 Phase Conductor Current Current Cross Diameter Maximum Diameter Diameter Diameter Diameter Outer Weight Min DC section of over over of over diameter of bending reactance short rating rating in conductor resistance insulation extruded armour armour approx cable radius at 50 Hz circuit in air ground at ( ) at 20 °C approx * current at 30 °C 20 °C inner wires approx covering/ for 1 sec (gr.therm. taping res. 1 Km/W; depth of laying 0,8 m) 2 (Ω/km) (Ω/km) (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (kA) (A) (A) 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,1 15,7 18,4 20,5 22,8 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 10,1 12,0 13,6 15,4 17,2 19,0 21,9 24,2 27,0 30,7 34,8 12,1 14,0 15,6 17,4 19,2 21,0 23,9 26,2 29,4 33,1 37,2 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 16,1 18,0 19,6 21,4 23,2 25,0 27,9 30,2 33,4 37,1 41,2 19,7 21,6 23,2 25,0 26,8 28,6 31,7 34,2 37,6 41,5 45,8 850 1080 1360 1630 1940 2320 2920 3580 4490 5630 7140 275 305 325 350 375 400 445 480 530 580 640 0,12 0,11 0,10 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,09 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 57,8 72,2 90,9 230 288 350 404 457 521 611 692 785 889 994 233 284 338 382 424 474 542 600 665 732 796 ( ) * trefoil formation 113 Power cables TEPLA Plant & Petrochem Cables TEPLA L (XLPE/PVC or XLPE/LS0H) multi-core 0,6/1 kV Construction > > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD GOOD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Fillers non hygroscopic compound or LS0H non hygroscopic compound Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” or e. g. : “PRYSMIAN Afumex year n x csa 0,6/1 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 12 D low r IEC 60332-1 IEC 60332-3C 114 GOOD GOOD LS0H -5 °C 12 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA L 0,6/1 kV (XLPE/PVC or XLPE/LS0H) - multi-core Diameter Maximum Diameter DC of over conductor resistance insulation at 20 °C Diameter over extruded inner covering Outer diameter approx Weight of cable approx Min bending radius (mm) (Ω/km) (mm) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 11,4 13,3 16,5 18,6 21,1 24,9 28,1 32,2 35,9 39,6 9,6 10,4 11,5 12,6 15,1 17,0 20,2 22,3 24,8 28,6 32,2 36,6 40,4 44,3 130 160 210 270 420 580 860 1110 1440 1970 2640 3370 4120 5060 115 125 140 150 180 205 245 270 300 345 385 440 485 530 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 28 37 49 63 86 113 152 186 226 287 354 410 468 538 37 49 64 80 106 137 177 213 253 312 374 424 475 536 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 12,2 14,2 17,8 20,0 22,7 26,8 30,2 34,7 38,6 42,6 10,1 10,9 12,1 13,3 15,9 17,9 21,5 23,7 26,4 30,7 34,3 39,0 43,3 47,5 150 190 250 330 510 720 1080 1400 1830 2550 3430 4360 5350 6600 120 130 145 160 190 215 260 285 315 370 410 470 520 570 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 23 31 41 53 72 96 129 158 193 245 302 351 399 460 31 41 53 67 88 114 149 179 212 261 314 355 397 449 RE4OM1/RE4OR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 13,5 15,8 19,8 22,3 25,3 29,9 34,4 38,7 43,0 47,5 10,9 11,8 13,1 14,4 17,2 19,5 23,5 26,0 29,2 34,0 38,7 43,4 47,9 53,0 180 220 300 400 630 890 1340 1760 2330 3250 4430 5580 6820 8480 130 140 160 175 205 235 280 310 350 410 465 520 575 635 0,11 0,10 0,09 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 23 31 41 53 72 96 129 158 193 245 302 351 399 460 31 41 53 67 88 114 149 179 212 261 314 355 397 449 RE4OM1/RE4OR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 7,8 7,8 8,8 10,1 12,0 13,6 13,6 17,2 17,2 21,7 24,1 28,3 32,6 36,9 41,2 44,7 52,5 56,8 25,4 27,8 32,2 36,9 41,4 46,1 49,8 58,2 62,9 1650 2060 2860 3920 4980 6210 7420 9960 12040 305 335 385 445 495 555 600 700 755 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 158 193 245 302 351 399 460 546 626 179 212 261 314 355 397 449 520 584 Voltage Cross section (kV) (mm2) RE4OM1/RE4OR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 RE4OM1/RE4OR Type Phase Conductor Current reactance short rating at 50 Hz circuit in air approx current at 30 °C for 1 sec 115 Power cables TEPLA Plant & Petrochem Cables TEPLA L - A (XLPE/SWA/PVC or XLPE/SWA/LS0H) multi-core 0,6/1 kV Construction > > > > > > Applicable standards IEC 60502-1 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Inner covering non hygroscopic compound or LS0H non hygroscopic compound Armour galvanized steel wire Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 0,6/1kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 116 GOOD EXCELLENT LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-1 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA L - A 0,6/1 kV (XLPE/SWA/PVC or XLPE/SWA/LS0H) - multi-core Type Voltage (kV) Phase Conductor Current Current Cross Diameter Maximum Diameter Diameter Diameter Diameter Outer Weight Min DC section of over over of over diameter of bending reactance short rating rating in conductor resistance insulation extruded armour armour approx cable radius at 50 Hz circuit in air ground at at 20 °C approx current at 30 °C inner wires approx 20 °C covering for 1 sec (gr.therm. res. 1 Km/W; depth of laying 0,8 m) 2 (Ω/km) (Ω/km) (mm ) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (kA) (A) (A) RE4OFM1/RE4OFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 8,1 8,8 9,9 11,0 12,4 14,3 17,5 19,6 22,1 25,9 29,5 33,1 36,7 40,8 0,8 0,8 0,8 0,8 1,3 1,3 1,6 1,6 1,6 1,6 2,0 2,0 2,0 2,5 9,7 10,4 11,5 12,6 14,9 16,8 20,7 22,8 25,3 29,1 33,5 37,1 40,7 45,8 13,3 14,0 15,1 16,2 18,5 20,4 24,3 26,4 28,9 33,1 37,7 41,5 45,3 50,8 330 370 440 530 800 1010 1510 1820 2230 2930 3990 4810 5690 7300 185 195 210 225 260 285 340 370 405 465 530 580 635 710 0,1 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 29 38 50 64 88 116 157 191 231 291 358 414 469 538 36 47 62 78 105 136 177 212 252 308 369 419 468 526 RE4OFM1/RE4OFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 8,5 9,4 10,5 11,7 13,2 15,2 18,8 21,0 23,7 28,2 31,6 35,5 39,8 43,8 0,8 0,8 0,8 0,8 1,3 1,3 1,6 1,6 1,6 2,0 2,0 2,0 2,5 2,5 10,1 11,0 12,1 13,3 15,7 17,7 22,0 24,2 26,9 32,2 35,6 39,5 44,8 48,8 13,7 14,6 15,7 16,9 19,3 21,3 25,6 27,8 30,7 36,2 40,0 44,1 49,8 54,0 360 410 500 600 910 1170 1760 2160 2700 3850 4880 5900 7550 9010 190 205 220 235 270 300 360 390 430 505 560 620 695 755 0,1 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 23 31 41 53 72 96 129 158 193 245 302 351 399 460 31 41 53 67 88 114 149 179 212 259 310 353 392 440 RE4OFM1/RE4OFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1.5 4x2.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 9,3 10,2 11,6 12,9 14,5 16,8 20,8 23,3 26,3 31,3 35,2 39,9 44,2 48,7 0,8 0,8 0,8 1,3 1,3 1,6 1,6 1,6 1,6 2,0 2,0 2,5 2,5 2,5 10,9 11,8 13,2 15,4 17,0 20,0 24,0 26,5 29,5 35,3 39,2 44,9 49,2 53,7 14,5 15,4 16,8 19,0 20,6 23,6 27,6 30,3 33,5 39,7 43,8 49,9 54,4 59,3 400 460 570 830 1060 1510 2080 2610 3270 4680 5970 7770 9240 11090 205 215 235 265 290 330 385 425 470 555 615 700 760 830 0,11 0,1 0,1 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 23 31 41 53 72 96 129 158 193 245 302 351 399 460 31 41 53 67 88 114 149 179 212 259 310 353 392 440 RE4OFM1/RE4OFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 7,8 7,8 8,8 10,1 12,0 13,6 13,6 17,2 17,2 22,7 25,1 29,7 33,4 37,7 42,4 45,9 53,7 58,0 1,6 1,6 2,0 2,0 2,0 2,5 2,5 2,5 2,5 25,9 28,3 33,7 37,4 41,7 47,4 50,9 58,7 63,0 29,5 32,1 37,9 41,8 46,5 52,4 56,3 64,5 69,0 2460 2960 4220 5350 6610 8510 9920 12840 15110 410 450 530 585 650 735 790 905 965 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 158 193 245 302 351 399 460 539 618 179 212 259 310 353 392 440 505 567 117 Power cables TEPLA Plant & Petrochem Cables TEPLA L - (AR) (XLPE/PSA/PVC) single core 0,6/1 kV Construction > > > > > Applicable standards IEC 60502-1 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-001 for PSA layer r IEC 60332-1 118 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Mechanical protective layer PSA (AIR BAG™) Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” 12 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - (AR) 0,6/1 kV (XLPE/PSA/PVC) - single core Type* RE4(AR)R Diameter Maximum Diameter Approx Diameter Outer DC of over thickness over diameter conductor resistance insulation of PSA approx at 20 °C PSA Weight of cable approx Phase Min Conductor bending reactance short at 50 Hz radius circuit approx (*) current for 1 sec Voltage Cross section Current rating in air at 30 °C (kV) (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,1 15,7 18,4 20,5 22,8 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 10,1 12,0 13,6 15,4 17,2 19,0 21,9 24,2 27,0 30,7 34,8 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 14,1 16,0 17,6 19,4 21,1 23,1 25,7 28,2 31,0 34,7 38,8 16,9 18,8 20,6 22,3 24,2 26,4 29,2 31,7 34,9 38,8 43,1 1018 1409 1912 2379 2913 3624 4712 5861 7452 9549 12338 202 225 247 267 290 317 350 380 419 465 517 0,105 0,100 0,096 0,093 0,093 0,092 0,088 0,086 0,086 0,084 0,082 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 >50 >50 >50 205 260 319 372 427 494 589 680 789 918 1062 216 266 319 364 409 463 537 607 688 779 877 ( ) * trefoil formation 119 Power cables TEPLA Plant & Petrochem Cables TEPLA L - (AR) (XLPE/PSA/PVC) multi-core 0,6/1 kV Construction > > > > > > Applicable standards IEC 60502-1 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-001 for PSA layer r IEC 60332-1 120 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Fillers non hygroscopic compound Mechanical protective layer PSA AIR BAGTM Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” 12 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - (AR) 0,6/1 kV (XLPE/PSA//PVC) - multi-core Type Voltage Cross Diameter Maximum Diameter Diameter Approx Diameter Outer DC section of over under thickness over diameter conductor resistance insulation PSA of PSA approx at 20 °C approx PSA approx Weight of cable approx Phase Conductor Current Current Min bending reactance short rating rating in radius at 50 Hz circuit in air ground at approx current at 30 °C 20 °C for 1 sec (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (Ω/km) (mm) (kA) (A) (A) (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (kg/km) RE4O(AR)R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19 8,1 8,9 10,0 11,0 12,4 14,3 17,6 19,7 22,2 26,0 29,2 32,7 36,2 40,2 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 12,1 12,9 14,0 15,0 16,4 18,3 21,6 23,7 26,2 30,0 33,2 36,7 40,2 45,2 15,6 16,4 17,4 18,5 19,9 21,8 25,1 27,2 29,7 33,5 37,1 40,8 44,4 49,6 262 300 361 430 545 717 1018 1282 1620 2183 2872 3553 4311 5354 187 196 209 222 239 262 301 326 356 402 445 489 533 595 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 25 34 46 58 78 105 141 173 210 266 328 380 434 500 31 42 55 68 90 126 164 197 234 289 346 392 439 496 RE4O(AR)R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 8,6 9,4 10,6 11,7 13,2 15,3 18,8 21,1 23,8 27,9 31,3 35,1 38,9 43,2 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 12,6 13,4 14,6 15,7 17,2 19,3 22,8 25,1 27,8 31,9 35,3 39,1 43,9 48,2 16,1 16,9 18,1 19,2 20,7 22,8 26,3 28,6 31,3 35,6 39,2 43,1 48,3 52,8 284 331 405 491 640 860 1241 1584 2026 2774 3669 4551 5612 6912 193 203 217 231 248 273 316 343 375 427 470 518 579 633 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 22 29 38 49 66 88 120 148 179 228 280 325 371 428 27 35 46 58 76 106 137 166 197 242 290 329 368 416 RE4O(AR)R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1.5 4x2.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 9,4 10,3 11,6 12,9 14,6 16,9 20,9 23,4 26,4 31,0 34,9 39,1 43,3 48,1 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 13,4 14,3 15,6 16,9 18,6 20,9 24,9 27,4 30,4 35,0 38,9 44,1 48,3 53,1 16,8 17,8 19,1 20,4 22,1 24,4 28,3 30,9 34,1 38,8 42,9 48,5 52,9 58,1 317 374 468 574 763 1043 1522 1960 2537 3488 4635 5836 7090 8774 202 213 229 245 265 292 340 370 409 466 515 582 635 697 0,11 0,10 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 22 29 38 49 66 88 120 148 179 228 280 325 371 428 27 35 46 58 76 106 137 166 197 242 290 329 368 416 RE4O(AR)R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 7,8 7,8 8,8 10,1 12,0 13,6 13,6 17,2 17,2 22,8 25,2 29,4 33,1 37,3 41,5 45,3 51,1 56,7 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 3,0 26,8 29,2 33,4 37,1 41,3 46,5 50,3 56,1 62,7 30,3 32,7 37,0 41,1 45,6 51,1 55,1 61,3 68,2 1849 2273 3101 4127 5206 6518 7780 9993 12425 364 392 444 493 547 613 661 735 819 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 148 179 228 280 325 371 428 507 584 166 197 242 290 329 368 416 481 542 121 Power cables TEPLA Plant & Petrochem Cables TEPLA L - L (XLPE/Pb/PVC) single core 0,6/1 kV Construction > > > > > Applicable standards EC 60332-1 122 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Metallic sheath lead alloy Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” IEC 60502-1 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - L 0,6/1 kV (XLPE/Pb/PVC) - single core Type* RE4LR Voltage Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter under lead sheath Outer diameter approx Weight of cable approx Min bending radius Phase Conductor reactance short at 50 Hz circuit ( ) approx * current for 1 sec (kV) (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 10,1 12,0 13,6 15,4 17,1 19,1 21,7 24,2 27,0 30,7 34,8 15,5 17,6 19,2 21,1 23,2 25,4 28,2 31,1 34,3 38,6 43,1 1454 1925 2482 3026 3701 4566 5780 9461 11940 15232 14577 248 282 307 338 371 406 451 498 549 618 690 0,100 0,096 0,092 0,090 0,090 0,089 0,087 0,085 0,085 0,083 0,082 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 >50 >50 >50 220 279 342 398 457 529 628 722 839 970 1113 232 283 338 383 429 485 560 640 709 796 887 Current rating in air at 30 °C ( ) * trefoil formation 123 Power cables TEPLA Plant & Petrochem Cables TEPLA L - L (XLPE/Pb/PVC) multi-core 0,6/1 kV Construction > > > > > > Applicable standards IEC 60332-1 124 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Fillers non hygroscopic compound Metallic sheath lead alloy Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” IEC 60502-1 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - L 0,6/1 kV (XLPE/Pb/PVC) - multi-core Type Diameter Maximum Diameter Diameter DC of over under conductor resistance insulation lead at 20 °C sheath Voltage Cross section (kV) (mm2) (mm) (Ω/km) (mm) RE4OLR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 RE4OLR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 RE4OLR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 RE4OLR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 Phase Conductor reactance short at 50 Hz circuit approx current for 1 sec Outer diameter approx Weight of cable approx Min bending radius Current rating in air at 30 °C (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 8,1 8,9 10 11,1 13,5 15,4 18,7 20,8 23,3 27,1 30,3 34,3 37,8 42,2 14,2 15,0 16,1 17,2 19,5 21,4 24,7 26,8 29,5 33,7 37,5 41,9 45,8 50,6 604 672 772 881 1147 1397 1834 2184 2726 3582 4548 5644 6757 8229 228 240 257 275 313 343 396 429 473 540 600 671 733 810 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 30 39 51 65 89 118 158 193 233 293 362 417 474 545 37 48 63 79 104 136 176 212 252 309 372 421 472 531 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 8,6 9,5 10,6 11,8 14,3 16,3 19,9 22,2 24,8 28,9 32,4 36,7 40,9 45,2 14,7 15,5 16,7 17,9 20,3 22,4 25,9 28,4 31,5 36,0 39,8 44,7 49,3 54,2 646 724 842 971 1275 1581 2107 2632 3321 4378 5587 6949 8401 10186 235 248 267 286 325 358 415 454 504 576 637 715 788 867 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 25 33 43 55 75 99 134 164 198 251 307 354 402 460 31 41 53 66 88 114 148 178 211 260 310 351 391 440 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 9,4 10,4 11,7 13 15,6 17,9 21,9 24,4 27,4 32 36,5 41,1 45,3 50,1 15,5 16,4 17,7 19,0 21,7 24,0 28,2 30,7 34,5 39,5 44,6 49,5 54,3 59,9 709 802 945 1100 1455 1831 2560 3110 4071 5386 7017 8637 10385 12782 247 262 283 304 347 383 450 491 552 632 713 791 868 958 0,11 0,10 0,09 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 25 33 43 55 75 99 134 164 198 251 307 354 402 460 31 41 53 66 88 114 148 178 211 260 310 351 391 440 7,0 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 8,9 10,1 12,0 13,6 15,4 17,1 19,1 21,7 24,2 23,9 26,3 30,4 34,7 39 43,5 47,3 53,2 58,7 30,1 32,9 37,7 42,3 46,9 52,3 56,5 62,9 69,3 2971 3632 4795 6234 7713 9639 11345 14195 17417 482 526 603 677 751 836 904 1007 1108 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 164 198 251 307 354 402 460 541 615 178 211 260 310 351 391 440 506 565 125 Power cables TEPLA Plant & Petrochem Cables TEPLA L - LA (XLPE/Pb/AWA/PVC) single core 0,6/1 kV Construction > > > > > > > Applicable standards IEC 60332-1 126 EXCELLENT EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Metallic sheath Lead alloy Separation sheath PVC compound ST2 quality Armour aluminium wires Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” IEC 60502-1 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - LA 0,6/1 kV (XLPE/Pb/AWA//PVC) - single core Type* Voltage RE4LRFR Cross Diameter Maximum Diameter Diameter Diameter Diameter Outer DC section of over over of over diameter conductor resistance insulation extruded armour armour approx at 20 °C inner wires sheath Weight of cable approx (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (kg/km) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,1 15,7 18,4 20,5 22,8 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 10,1 12,0 13,6 15,4 17,2 19,0 21,9 24,2 27,0 30,7 34,8 14,4 16,3 17,9 19,6 21,6 23,8 26,5 29,2 32,4 36,4 40,8 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 18,4 20,3 21,9 23,6 25,6 27,8 30,5 33,2 36,4 41,5 45,9 22,4 24,3 25,9 27,6 29,8 32,2 35,0 37,8 41,5 46,8 51,6 1783 2282 2864 3425 4137 5050 6313 10043 12615 16130 15594 Phase Conductor Current Current Min bending reactance short rating rating in radius at 50 Hz circuit in air ground at ( ) approx * current at 30 °C 20 °C for 1 sec (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (Ω/km) (mm) (kA) (A) (A) 359 389 415 442 476 515 560 605 664 749 825 0,26 0,26 0,25 0,25 0,25 0,25 0,24 0,24 0,24 0,24 0,23 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 >50 >50 >50 241 299 362 415 470 534 621 700 787 865 956 234 284 336 379 420 468 532 587 645 686 738 ( ) * trefoil formation 127 Power cables TEPLA Plant & Petrochem Cables TEPLA L - LA (XLPE/Pb/SWA/PVC) multi-core 0,6/1 kV Construction > > > > > > > > Applicable standards IEC 60332-1 128 EXCELLENT EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Fillers non hygroscopic compound Metallic sheath lead alloy Separation sheath PVC compound ST2 quality Armour galvanized steel wires Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” IEC 60502-1 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - LA 0,6/1 kV (XLPE/Pb/SWA//PVC) - multi-core Type Voltage Cross Diameter Maximum Diameter Diameter Diameter Diameter Outer DC section of over over of over diameter conductor resistance insulation extruded armour armour approx at 20 °C inner wires sheath Weight of cable approx Phase Conductor Current Current Min bending reactance short rating rating in radius at 50 Hz circuit in air ground approx current at 30 °C at 20 °C for 1 sec (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (Ω/km) (mm) (kA) (A) (A) (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (kg/km) RE4OLRFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 12,4 13,2 14,2 15,3 17,7 19,6 22,9 25 27,9 31,9 35,5 39,9 43,6 48,4 1,25 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2,0 2,0 2,0 2,5 2,5 2,5 14,9 15,7 16,7 17,8 20,9 22,8 26,1 28,2 31,9 35,9 39,5 44,9 48,6 53,4 18,0 18,7 19,8 20,9 24,0 25,9 29,2 31,4 35,3 39,7 43,4 49,0 53,1 58,0 986 1075 1199 1341 1802 2107 2652 3087 3986 5029 6140 7862 9176 10938 287 300 317 334 383 414 467 503 565 634 694 784 849 928 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 30 39 51 65 89 118 158 193 233 293 362 417 474 545 37 48 63 79 104 136 176 212 252 309 372 421 472 531 RE4OLRFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 12,9 13,7 14,9 16 18,5 20,6 24,1 26,6 29,7 34,1 37,9 42,5 47 51,7 1,25 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2,0 2,0 2,5 2,5 2,5 2,5 15,4 16,2 17,4 18,5 21,7 23,8 27,3 29,8 33,7 38,1 42,9 47,5 52,0 56,7 18,4 19,3 20,4 21,6 24,8 26,8 30,6 33,0 37,2 41,9 47,1 51,8 56,7 61,6 1039 1140 1281 1443 1966 2326 2990 3589 4666 5912 7732 9300 11021 13074 295 308 327 345 396 429 489 528 596 670 753 828 907 985 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 25 33 43 55 75 99 134 164 198 251 307 354 402 460 31 41 53 66 88 114 148 178 211 260 310 351 391 440 RE4OLRFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1.5 4x2.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 1,6 2,0 2,5 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,2 15,8 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,1 3,4 4,0 4,5 5,2 6,2 7,8 8,9 10,1 12,0 13,6 15,4 17,1 19,1 13,7 14,6 15,9 17,2 19,9 22,2 26,4 29,1 32,6 37,4 42,3 47,3 51,9 57,3 1,25 1,25 1,25 1,6 1,6 1,6 1,6 2,0 2,0 2,0 2,5 2,5 2,5 2,5 16,2 17,1 18,4 20,4 23,1 25,4 29,6 33,1 36,6 41,4 47,3 52,3 56,9 62,3 19,2 20,2 21,5 23,5 26,1 28,4 32,8 36,6 40,4 45,4 51,6 56,9 61,8 67,4 1124 1240 1417 1737 2182 2629 3516 4441 5547 7063 9367 11299 13299 15969 307 322 343 375 418 455 524 586 647 726 825 910 989 1079 0,11 0,10 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 25 33 43 55 75 99 134 164 198 251 307 354 402 460 31 41 53 66 88 114 148 178 211 260 310 351 391 440 RE4OLRFR 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 7,0 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 8,9 10,1 12,0 13,6 15,4 17,1 19,1 21,7 24,2 28,5 31,1 35,6 40,3 44,9 50 54,1 60,3 66,6 2,0 2,0 2,0 2,5 2,5 2,5 2,5 2,5 3,15 32,5 35,1 39,6 45,3 49,9 55,0 59,1 65,3 72,9 35,9 38,7 43,5 49,6 54,4 59,9 64,1 70,6 78,7 4259 5033 6387 8514 10239 12460 14353 17551 22612 574 619 697 793 870 958 1025 1130 1260 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 164 198 251 307 354 402 460 541 615 178 211 260 310 351 391 440 506 565 129 Power cables TEPLA Plant & Petrochem Cables TEPLA L - D (XLPE/DRYLAM/PVC) single core 0,6/1 kV Construction > > > > > Applicable standards IEC 60502-1 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-003 for chemical moisture barrier r IEC 60332-1 130 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Chemical moisture barrier longitudinally applied Al tape bonded with extruded chemical resistant polymeric layer Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” 14 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - D 0,6/1 kV (XLPE/DRYLAM/PVC) - single core Type* RE4H5R4R Voltage Cross section Diameter of conductor Maximum DC resistance at 20 °C Diameter Drylam Outer diameter approx Weight of cable approx Min bending radius Phase Conductor reactance short at 50 Hz circuit ( ) approx * current for 1 sec (kV) (mm2) (mm) (Ω/km) (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,1 15,7 18,4 20,5 22,8 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 10,1 12 13,6 15,4 17,2 19 21,9 24,2 27 30,7 34,8 15,6 17,7 19,3 21,2 23,1 25,1 27,9 30,6 33,6 37,6 42,0 1042 1440 1936 2414 2954 3655 4750 8224 10455 13427 12400 218 247 270 296 324 352 390 428 470 527 588 0,12 0,11 0,10 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,09 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 >50 >50 >50 214 271 332 387 444 512 609 702 812 941 1082 223 273 327 372 417 471 546 614 694 781 874 Current rating in air at 30 °C ( ) * trefoil formation 131 Power cables TEPLA Plant & Petrochem Cables TEPLA L - D (XLPE/DRYLAM/PVC) multi-core 0,6/1 kV Construction > > > > > > Applicable standards IEC 60502-1 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-003 for chemical moisture barrier r IEC 60332-1 132 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Insulation XLPE compound Fillers non hygroscopic compound Chemical moisture barrier longitudinally applied Al tape bonded with extruded chemical resistant polymeric layer Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 0,6/1 kV” 14 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA L - D 0,6/1 kV (XLPE/DRYLAM/PVC) - multi-core Type Diameter Maximum Diameter Diameter DC of over under conductor resistance insulation Drylam at 20 °C Voltage Cross section (kV) (mm2) (mm) (Ω/km) (mm) RE4OH5R4R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 2x50 2x70 2x95 2x120 2x150 2x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 RE4OH5R4R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35 3x50 3x70 3x95 3x120 3x150 3x185 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 RE4OH5R4R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 4x1.5 4x2.5 4x4 4x6 4x10 4x16 4x25 4x35 4x50 4x70 4x95 4x120 4x150 4x185 RE4OH5R4R 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 0,6/1 3x35/25 3x50/25 3x70/35 3x95/70 3x120/70 3x150/95 3x185/95 3x240/150 3x300/150 Phase Conductor reactance short at 50 Hz circuit approx current for 1 sec Outer diameter approx Weight of cable approx Min bending radius Current rating in air at 30 °C (mm) (mm) (kg/km) (mm) (Ω/km) (kA) (A) Current rating in ground at 20 °C (gr.therm. res. 1 Km/W; depth of laying 0,8 m) (A) 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12 13,6 15,4 17,2 19,0 8,1 8,9 10,0 11,1 12,5 14,2 17,7 19,7 22,3 26,5 29,3 33,0 36,6 40,4 14,4 15,2 16,3 17,3 18,7 20,6 23,9 26,0 28,5 32,4 35,8 39,7 43,6 47,9 267 303 364 432 544 711 1001 1255 1590 2146 2800 3469 4225 5205 202 212 228 243 262 288 334 363 398 454 501 555 610 671 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 28 37 48 62 85 113 151 185 223 281 347 400 455 523 36 47 61 77 102 133 173 208 247 303 366 414 464 522 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12 13,6 15,4 17,2 19 8,5 9,3 10,6 11,7 13,2 15,2 18,8 21,0 24,0 28,1 31,6 35,5 39,4 43,2 14,9 15,7 16,8 18,0 19,5 21,5 25,1 27,3 30,2 34,5 38,3 42,2 46,6 51,1 290 337 408 494 641 857 1230 1565 2023 2750 3648 4511 5524 6804 208 220 236 252 273 301 351 383 423 483 536 591 652 715 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,07 0,07 0,07 0,07 0,07 0,07 0,07 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 24 31 41 52 72 95 128 157 190 240 294 339 385 441 30 40 52 64 86 112 145 175 207 255 305 345 384 432 1,6 2,0 2,6 3,1 3,8 4,7 6,0 7,0 8,1 9,8 11,4 12,9 14,3 15,7 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 3,0 3,4 4,0 4,5 5,2 6,1 7,8 8,8 10,1 12,0 13,6 15,4 17,2 19,0 9,3 10,2 11,7 12,9 14,6 16,8 20,9 23,3 26,6 31,2 35,1 39,5 43,8 48,2 15,7 16,6 17,9 19,2 20,8 23,1 27,1 29,6 33,0 38,0 42,0 46,8 51,2 56,4 324 379 473 578 765 1041 1510 1942 2535 3481 4616 5774 7027 8669 220 232 250 269 292 324 379 415 462 531 588 655 717 789 0,11 0,10 0,10 0,09 0,09 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,3 0,4 0,6 0,9 1,5 2,4 3,7 5,2 7,4 10,2 13,9 17,5 21,8 26,9 24 31 41 52 72 95 128 157 190 240 294 339 385 441 30 40 52 64 86 112 145 175 207 255 305 345 384 432 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 7,8 7,8 8,8 10,1 12,0 13,6 13,6 17,2 17,2 22,9 25,2 29,4 33,1 37,6 41,7 45,5 51,8 57,3 29,1 31,7 36,0 40,2 44,7 49,2 53,4 60,0 65,7 1831 2275 3083 4114 5178 6421 7683 9929 12218 407 443 504 563 625 689 747 840 920 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 0,08 5,2 7,4 10,2 13,9 17,5 21,8 26,9 34,8 43,4 157 190 240 294 339 385 441 519 590 175 207 255 305 345 384 432 497 555 133 TEPLA Plant & Petrochem Cables 134 technergy TM INTEGRATED CABLING SOLUTIONS Power cables Medium Voltage cables 135 Power cables TEPLA Plant & Petrochem Cables TEPLA M - S (XLPE/CuT/PVC or XLPE/CuT/LS0H) single core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > Applicable standards IEC 60502-2 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD GOOD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 3,6/6 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 136 GOOD GOOD LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA M - S from 3,6/6 (7,2) kV to 18/30 (36) kV (XLPE/CuT/PVC or XLPE/CuT/LS0H) - single core Type* Voltage Cross Diameter Maximum Diameter Diameter Outer DC section of over over diameter conductor resistance insulation screen approx at 20 °C approx approx Weight of cable approx Max Phase Min Phase Conductor current bending reactance capacity short carrying at 50 Hz approx radius circuit approx (*) current capacity in air 30 °C (single core in trefoil format) (Ω/km) (µF/km) (kA/sec) (mm) (A) Max current carrying capacity in gound (T 20 °C, depth 1 m, gtr Km/W) (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (kg/km) RE4H1R/RE4H1M1 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 13,2 14,4 15,9 17,6 19,1 20,5 22,0 24,8 27,8 30,6 34,2 38,5 14,4 15,6 17,1 18,8 20,3 21,7 23,2 26,0 28,9 31,7 35,3 39,7 18,0 19,2 20,7 22,4 23,9 25,3 26,8 29,8 32,9 35,9 39,7 44,3 620 750 970 1240 1470 1780 2130 2730 3390 4260 5390 6880 250 270 290 320 340 360 380 520 460 500 560 620 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,09 0,08 0,28 0,31 0,35 0,40 0,44 0,47 0,52 0,57 0,59 0,61 0,65 0,74 5,2 7,4 10,3 13,9 17,5 21,9 26,9 34,8 43,5 >50 >50 >50 187 225 281 344 398 454 522 621 717 830 963 1113 188 222 272 326 370 415 469 542 611 691 780 877 RE4H1R/RE4H1M1 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 14 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 34,6 38,9 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 35,7 40,1 19,8 21,0 22,5 24,2 25,7 27,1 28,8 31,6 34,1 36,7 40,1 44,7 680 810 1040 1320 1570 1850 2230 2830 3460 4310 5420 6910 280 300 320 340 360 380 410 450 480 520 560 630 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,09 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,5 0,55 0,61 0,7 5,2 7,4 10,3 13,9 17,5 21,9 26,9 34,8 43,5 >50 >50 >50 190 229 285 349 404 460 526 627 721 833 964 1114 188 222 272 326 370 416 468 542 611 692 781 878 RE4H1R/RE4H1M1 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 17,2 18,4 19,9 21,6 23,1 24,5 26,0 28,6 31,2 33,6 36,8 41,1 18,4 19,6 21,1 22,8 24,2 25,6 27,2 29,8 32,3 34,7 37,9 42,3 22,0 23,2 24,7 26,4 28,0 29,4 31,2 33,8 36,5 39,1 42,5 47,1 760 900 1130 1410 1690 1970 2360 2950 3610 4470 5590 7100 310 330 350 370 390 410 440 470 510 550 600 660 0,13 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,10 0,09 0,09 0,09 0,18 0,20 0,22 0,25 0,27 0,29 0,32 0,36 0,40 0,43 0,48 0,55 5,2 7,4 10,3 13,9 17,5 21,9 26,9 34,8 43,5 >50 >50 >50 194 233 290 354 408 464 532 632 727 839 971 1121 189 223 272 326 370 415 468 543 612 693 783 882 RE4H1R/RE4H1M1 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 38,8 43,1 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 39,9 44,3 24,0 25,2 26,7 28,6 30,0 31,6 33,2 36,0 38,7 41,3 44,7 49,3 840 980 1130 1520 1790 2090 2460 3080 3750 4620 5760 7280 340 350 370 400 420 440 470 500 540 580 630 690 0,14 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 0,41 0,46 5,2 7,4 10,3 13,9 17,5 21,9 26,9 34,8 43,5 >50 >50 >50 197 236 293 357 412 468 536 637 731 844 976 1127 189 223 272 326 370 415 468 543 612 693 785 885 RE4H1R/RE4H1M1 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 25,4 26,9 28,8 30,1 31,5 33,0 35,6 38,2 40,6 43,8 48,1 26,5 28,1 29,8 31,2 32,6 34,2 36,8 39,3 41,7 44,9 49,3 30,3 32,1 34,0 35,4 36,8 38,6 41,4 43,9 46,7 49,9 54,7 1230 1500 1820 2100 2390 2800 3450 4120 5030 6170 7760 420 450 480 500 520 540 580 620 650 700 770 0,14 0,13 0,13 0,12 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,14 0,15 0,17 0,18 0,19 0,21 0,23 0,25 0,27 0,30 0,34 7,4 10,3 13,9 17,5 21,9 26,9 34,8 43,5 >50 >50 >50 241 299 364 419 475 544 644 739 852 985 1136 223 272 325 370 415 468 543 613 695 788 889 ( ) * trefoil formation (A) 137 Power cables TEPLA Plant & Petrochem Cables TEPLA M - S (XLPE/CuT/PVC or XLPE/CuT/LS0H) multi-core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > Applicable standards IEC 60502-2 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD GOOD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Fillers non hygroscopic compound or LS0H non hygroscopic compound Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 3,6/6 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables(if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 138 GOOD GOOD LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA M - S from 3,6/6 (7,2) kV to 18/30 (36) kV (XLPE/CuT/PVC or XLPE/CuT/LS0H) - multi-core Type Voltage (kV) Phase Cross Diameter Maximum Diameter Diameter Diameter Outer Weight Min Phase Conductor Max Max DC section of over over over diameter of bending reactance capacity short current current conductor resistance insulation screen extruded approx cable radius at 50 Hz approx circuit carrying carrying at 20 °C approx approx approx inner approx current capacity capacity covering in air in 30 °C ground (single (T 20 °C, core in depth 1 trefoil m, gtr format) Km/W) (Ω/km) (Ω/km) (µF/km) (kA/sec) (mm2) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (A) (A) RE4H1OR/RE4H1OM1 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 13,2 14,4 15,9 17,6 19,1 20,5 22,0 24,8 27,8 30,6 14,4 15,6 17,1 18,8 20,3 21,7 23,2 26,0 28,9 31,7 32,7 35,2 38,5 42,2 45,3 48,3 51,6 58,0 64,3 70,4 37,0 39,7 43,2 47,3 50,8 54,0 57,5 64,3 71,0 77,5 2430 2950 3750 4790 5750 6760 8060 10320 12780 15880 520 560 610 660 710 760 810 900 1000 1090 0,11 0,10 0,09 0,09 0,09 0,09 0,08 0,08 0,08 0,08 0,28 0,31 0,35 0,4 0,44 0,47 0,52 0,57 0,59 0,61 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 180 216 268 327 376 427 488 571 654 751 183 216 263 314 356 399 450 517 581 657 RE4H1OR/RE4H1OM1 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 36,6 39,0 42,4 46,0 49,2 52,6 55,8 61,4 66,9 72,5 41,3 44,0 47,5 51,5 54,9 58,5 61,9 67,9 73,8 79,8 2790 3330 4180 5250 6220 7320 8630 10840 13210 16290 580 620 670 720 770 820 870 950 1030 1120 0,11 0,11 0,10 0,10 0,09 0,09 0,09 0,09 0,08 0,08 0,2 0,25 0,28 0,31 0,34 0,37 0,4 0,45 0,5 0,55 5 7,2 10 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 183 219 272 330 380 430 487 575 656 749 183 216 263 314 357 398 447 517 581 655 RE4H1OR/RE4H1OM1 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,2 9,7 11,4 12,9 14,3 15,8 18,4 20,6 23,0 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 17,2 18,4 19,9 21,6 23,1 24,5 26,0 28,6 31,2 33,6 18,4 19,6 21,1 22,8 24,2 25,6 27,2 29,8 32,3 34,7 41,3 43,8 47,1 50,8 54,2 57,2 60,6 66,2 71,7 77,2 46,4 49,3 52,8 56,7 60,3 63,5 67,1 73,1 78,8 84,9 3290 3880 4760 5850 6900 7970 9350 11610 14010 17200 650 690 740 790 850 890 940 1020 1100 1190 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,18 0,2 0,22 0,25 0,27 0,29 0,32 0,36 0,4 0,43 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 186 222 275 334 380 430 491 578 660 753 183 215 263 314 354 396 447 517 582 656 RE4H1OR/RE4H1OM1 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7 8,2 9,7 11,4 12,9 14,3 15,8 18,4 20,6 23,0 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 45,6 48,1 51,4 55,4 58,5 61,5 64,9 70,5 76,4 81,5 51,1 53,8 57,3 61,5 64,8 68,0 71,8 77,6 83,9 89,4 3790 4380 5300 6470 7510 8610 10050 12330 14920 18030 720 750 800 860 910 950 1000 1090 1170 1250 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,3 0,34 0,37 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 188 224 277 333 383 433 493 581 660 756 183 215 263 312 354 396 447 517 581 657 RE4H1OR/RE4H1OM1 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 25,4 26,9 28,8 30,1 31,5 33,0 35,6 38,2 26,5 28,1 29,8 31,2 32,6 34,2 36,8 39,3 59,2 62,5 66,2 69,3 72,7 76,0 81,6 87,1 65,7 69,2 73,1 76,4 80,0 83,5 89,5 95,4 5920 6920 8140 9260 10530 12020 14490 17130 920 970 1020 1070 1120 1170 1250 1340 0,13 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,14 0,15 0,17 0,18 0,19 0,21 0,23 0,25 7,2 10 13,6 17,2 21,5 26,5 34,4 43 225 279 337 387 436 497 583 664 213 260 311 353 395 446 516 581 139 Power cables TEPLA Plant & Petrochem Cables TEPLA M - SA (XLPE/CuT/AWA/PVC or XLPE/CuT/AWA/LS0H) single core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > > Applicable standards IEC 60502-2 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Separation sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Armour aluminium wires Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 3,6/6 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables(if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 140 GOOD EXCELLENT LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA M - SA from 3,6/6 (7,2) kV to 18/30 (36) kV (XLPE/CuT/AWA/PVC or XLPE/CuT/AWA/LS0H) - single core Phase Phase Conductor Max Voltage Cross Diameter Maximum Diameter Diameter Diameter Diameter Diameter Outer Weight Min Max DC over over over of over diameter of bending reactance capacity short current current section of 50Hz approx circuit carrying carrying conductor resistance insulation screen separation armour armour approx cable radius at 20 °C approx approx sheath approx(*) wires approx current capacity capacity in air in 30 °C ground (single (T 20 °C, core depth 1 in trefoil m, gtr format) Km/W) (Ω/km) (mm) (kV) (mm2) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (Ω/km) (µF/km) (kA/sec) (A) (mm) (A) Type* RE4H1RFR/ RE4GHM1FM1 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1X630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 14,4 15,9 17,6 19,1 20,5 22,0 24,8 27,8 30,6 34,2 38,5 15,6 17,1 18,8 20,3 21,7 23,2 26,0 28,9 31,7 35,3 39,7 17,7 19,4 21,0 22,5 23,9 25,4 28,4 31,3 34,1 37,9 42,5 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 21,7 23,4 25,0 26,5 27,9 29,4 32,4 35,3 38,1 42,9 47,5 25,4 27,7 28,8 30,4 32,0 33,4 37,2 40,3 43,3 48,5 52,7 1140 1380 1700 1970 2280 2660 3410 4130 5060 6480 7900 360 390 400 430 450 470 520 570 610 680 740 0,13 0,13 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,10 0,10 0,31 0,35 0,4 0,44 0,47 0,52 0,57 0,59 0,61 0,65 0,74 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 239 295 358 410 461 523 610 688 777 854 948 223 271 322 363 403 450 511 565 625 666 720 RE4H1RFR/ RE4GHM1FM1 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 34,6 38,9 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 35,7 40,1 19,6 21,3 23,0 24,5 25,9 27,4 30,0 32,5 34,9 38,3 42,9 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 23,6 25,3 27,0 28,5 29,9 31,4 34,0 36,5 38,9 43,3 47,9 27,3 29,2 31,0 32,5 34,7 36,2 39,0 41,5 44,3 48,9 53 1230 1500 1820 2100 2490 2880 3540 4230 5150 6510 7950 380 410 430 460 490 510 550 580 620 690 740 0,14 0,13 0,12 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,10 0,25 0,28 0,31 0,34 0,37 0,4 0,45 0,5 0,55 0,61 0,7 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 241 298 360 412 464 525 612 690 777 856 950 223 271 321 362 402 449 511 565 624 667 721 RE4H1RFR/ RE4GHM1FM1 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 18,4 19,9 21,6 23,1 24,5 26,0 28,6 31,2 33,6 36,8 41,1 19,6 21,1 22,8 24,2 25,6 27,2 29,8 32,3 34,7 37,9 42,3 21,9 23,5 25,2 26,6 28,0 29,6 32,2 34,7 37,3 40,5 45,1 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 25,9 27,5 29,2 30,6 32,0 33,6 36,2 38,7 42,3 45,5 50,1 29,7 31,6 33,8 35,4 36,8 38,6 41,4 43,9 47,9 51,3 55,5 1380 1650 2020 2320 2640 3070 3730 4420 5530 6750 8180 420 440 470 500 520 540 580 620 670 720 780 0,14 0,13 0,13 0,12 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,2 0,22 0,25 0,27 0,29 0,32 0,36 0,4 0,43 0,48 0,55 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 243 300 362 414 466 527 614 692 767 858 952 223 270 321 361 402 447 510 564 609 665 720 RE4H1RFR/ RE4GHM1FM1 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 38,8 43,1 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 39,9 44,3 23,8 25,5 27,2 28,6 30,0 31,6 34,2 36,9 39,3 42,7 47,1 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 2,5 27,8 29,5 31,2 32,6 34,0 35,6 38,2 41,9 44,3 47,7 52,1 31,9 33,6 36,0 37,4 39,0 40,6 43,4 47,3 49,9 53,5 57,7 1510 1770 2170 2470 2800 3210 3890 4770 5710 6960 8410 450 470 500 520 550 570 610 660 700 750 810 0,15 0,14 0,13 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,17 0,19 0,22 0,24 0,25 0,27 0,3 0,34 0,37 0,41 0,46 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 244 301 364 416 468 529 616 686 770 860 954 222 270 320 361 401 447 509 553 609 665 720 RE4H1RFR/ RE4GHM1FM1 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 25,4 26,9 28,8 30,1 31,5 33,0 35,6 38,2 40,6 43,8 48,1 26,5 28,1 29,8 31,2 32,6 34,2 36,8 39,3 41,7 44,9 49,3 28,9 30,5 32,2 33,6 35,2 36,8 39,4 42,1 44,5 47,9 52,3 2,0 2,0 2,0 2,0 2,5 2,5 2,5 2,5 2,5 2,5 2,5 32,9 34,5 36,2 37,6 40,2 41,8 44,4 47,1 49,5 52,9 57,3 37,9 39,5 41,4 42,8 45,6 47,4 50,0 52,9 55,5 59,1 63,1 1950 2220 2580 2890 3410 3850 4540 5320 6280 7560 9000 530 550 580 600 640 660 700 740 780 830 880 0,16 0,15 0,14 0,14 0,13 0,13 0,12 0,12 0,12 0,11 0,11 0,14 0,15 0,17 0,18 0,19 0,21 0,23 0,25 0,27 0,3 0,34 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 247 304 367 419 469 529 614 688 772 863 959 221 269 319 359 396 440 500 551 606 663 719 ( ) * trefoil formation 141 Power cables TEPLA Plant & Petrochem Cables TEPLA M - SA (XLPE/CuT/SWA/PVC or XLPE/CuT/SWA/LS0H) multi-core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > > > Applicable standards IEC 60502-2 IEC 60228 IEC 60332-1 IEC 60332-3 C IEC 60754 IEC 61034 r IEC 60332-1 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Fillers non hygroscopic compound or LS0H non hygroscopic compound Separation sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Armour galvanized steel wires Sheath PVC compound ST2 quality or LS0H thermoplastic compound ST8 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” or e. g. : “PRYSMIAN Afumex year - n x csa 3,6/6 kV” Design and tests guidelines Conductors Flame retardant Fire retardant on bunched cables (if required) Halogen free properties (only for LS0H) Low smoke emission (only for LS0H) Pb 14 D low r IEC 60332-1 IEC 60332-3C 142 GOOD EXCELLENT LS0H -5 °C 14 D 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE PVC LS0H technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 > Fire retardant cables according to (if required) IEC 60332-3C TEPLA M - SA 3,6/6 (7,2) kV TO 18/30 (36) kV (XLPE/CuT/SWA/PVC or XLPE/CuT/SWA/LS0H) - multi-core Type Phase Phase Conductor Max Voltage Cross Diameter Maximum Diameter Diameter Diameter Diameter Diameter Outer Weight Min Max DC over current current over over of over diameter of bending reactance capacity short section of 50Hz approx circuit carrying carrying conductor resistance insulation screen separation armour armour approx cable radius at 20 °C approx approx sheath approx current capacity capacity wires approx in air in 30 °C ground (single (T 20 °C, core depth 1 in trefoil m, gtr format) Km/W) (Ω/km) (mm) (kV) (mm2) (A) (A) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) (Ω/km) (µF/km) (kA/sec) (mm) RE4H1ORFR/ RE4H1OF1M1 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 13,2 14,4 15,9 17,6 19,1 20,5 22,0 24,8 27,8 14,4 15,6 17,1 18,8 20,3 21,7 23,2 26,0 28,9 35,1 37,8 41,3 45,0 48,3 51,3 54,8 61,4 67,7 2,0 2,5 2,5 2,5 2,5 2,5 2,5 2,5 3,2 39,1 42,8 46,3 50 53,3 56,3 59,8 66,4 74,0 44,0 48,1 51,8 55,7 59,2 62,4 66,1 72,8 81,0 4210 5300 6330 7590 8710 9920 11450 13620 17400 620 670 730 780 830 880 930 1020 1130 0,11 0,1 0,09 0,09 0,09 0,09 0,08 0,08 0,08 0,28 0,31 0,35 0,4 0,44 0,47 0,52 0,57 0,59 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 182 218 269 326 374 423 479 557 629 180 213 259 308 349 390 437 499 552 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 39,2 41,8 45,2 49,0 52,4 55,8 59 65 2,5 2,5 2,5 2,5 2,5 2,5 2,5 3,2 44,2 46,8 50,2 54 57,4 60,8 64,0 71,3 49,5 52,3 55,9 60,1 63,7 67,3 70,4 78,1 5220 5940 6980 8290 9490 10790 11900 15300 700 730 780 840 890 940 960 1100 0,11 0,11 0,1 0,1 0,09 0,09 0,09 0,09 0,2 0,25 0,28 0,31 0,34 0,37 0,40 0,45 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 185 220 272 329 376 423 476 556 181 213 259 308 348 388 433 495 RE4H1ORFR/ RE4H1OF1M1 8,7/15 3x35 8,7/15 3x50 8,7/15 3x70 8,7/15 3x95 8,7/15 3x120 8,7/15 3x150 8,7/15 3x185 7,0 8,2 9,7 11,4 12,9 14,3 15,8 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 17,2 18,4 19,9 21,6 23,1 24,5 26,0 18,4 19,6 21,1 22,8 24,2 25,6 27,2 44,1 46,8 50,1 54,0 57,6 60,6 64,0 2,5 2,5 2,5 2,5 2,5 2,5 3,2 49,1 51,8 55,1 59,0 62,6 65,6 70,3 54,8 57,7 61,2 65,3 68,8 72,0 77,0 6040 6780 7870 9190 10100 11340 13790 770 810 860 920 960 1010 1080 0,12 0,11 0,11 0,1 0,1 0,1 0,09 0,18 0,20 0,22 0,25 0,27 0,29 0,32 5,0 7,2 10,0 13,6 17,2 21,5 26,5 187 222 274 331 375 424 480 180 212 259 308 346 387 432 RE4H1ORFR/ RE4H1OF1M1 12/20 3x35 12/20 3x50 12/20 3x70 12/20 3x95 12/20 3x120 12/20 3x150 12/20 3x185 7,0 8,2 9,7 11,4 12,9 14,3 15,8 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 19,2 20,4 21,9 23,6 25,1 26,5 28,0 20,4 21,6 23,1 24,8 26,2 27,6 29,2 48,6 51,3 54,6 58,7 61,9 65,1 68,4 2,5 2,5 2,5 2,5 3,2 3,2 3,2 53,6 56,3 59,6 63,7 68,2 71,4 74,7 59,5 62,4 66,1 70,1 74,8 78,2 82,0 6790 7570 8720 9790 11830 13170 14900 830 870 930 980 1050 1100 1150 0,13 0,12 0,11 0,11 0,1 0,1 0,1 0,16 0,17 0,19 0,22 0,24 0,25 0,27 5,0 7,2 10,0 13,6 17,2 21,5 26,5 188 224 276 330 378 426 481 180 212 258 306 346 385 431 RE4H1ORFR/ RE4H1OF1M1 18/30 18/30 8,1 9,8 0,387 0,268 25,4 26,9 26,5 28,1 62,5 66,2 3,2 3,2 68,8 72,5 75,6 79,5 10290 11600 1060 1110 0,13 0,13 0,14 0,15 7,2 10,0 224 276 210 256 RE4H1ORFR/ RE4H1OF1M1 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 3X50 3X70 143 Power cables TEPLA Plant & Petrochem Cables TEPLA M - S(AR) (XLPE/CuW/PSA/PVC) single core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > Applicable standards IEC 60502-2 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-001 for PSA layer r IEC 60332-1 144 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper wires Mechanical protective layer PSA AIR BAGTM Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/61 kV” 12 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - S(AR) from 3,6/6 (7,2) to 18/30 (36) kV (XLPE/CuW/PSA/PVC) - single core Phase Voltage Cross Diameter Maximum Diameter Diameter Diameter Approx Diameter Outer Weight Min Max Phase Conductor Max DC over over under thickness over diameter of cable bending reactance capacity short current current section of 50Hz approx circuit carrying carrying PSA of PSA approx approx radius conductor resistance insulation screen at 20 °C approx approx approx (*) PSA current capacity capacity in air in ground 30 °C (T 20° C, single core depth 1 in trefoil m, gtr format) Km/W) Type* (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (mm) RE4H1(AR)R 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1X630 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 15,9 17,6 19,1 20,5 22,0 24,8 27,8 30,6 34,2 38,5 17,1 18,8 20,3 21,7 23,2 26,0 28,9 31,7 35,3 39,7 18,9 20,4 21,8 23,2 24,8 27,4 30,4 33,2 36,8 41,2 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 22,9 24,4 25,8 27,2 28,8 31,4 34,4 37,2 41,8 46,2 26,2 27,7 29,3 30,7 32,4 35,2 38,2 41,4 46,3 50,8 1091 1358 1619 1895 2271 2866 3520 4386 5564 7074 314 332 352 368 389 423 459 497 555 609 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,10 0,09 0,09 0,35 0,40 0,44 0,47 0,52 0,57 0,59 0,61 0,65 0,74 RE4H1(AR)R 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 34,6 38,9 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 35,7 40,1 18,9 20,5 22,0 23,5 24,9 26,5 28,9 31,6 34,0 37,3 41,6 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 22,9 24,5 26,0 27,5 28,9 30,5 32,9 35,6 38,0 42,3 46,6 26,2 27,8 29,5 31,0 32,6 34,2 36,8 39,6 42,2 46,7 51,2 935 1152 1445 1699 1990 2361 2953 3607 4441 5593 7111 314 333 354 372 391 410 441 475 507 560 614 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,09 0,09 RE4H1(AR)R 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 18,4 19,9 21,6 23,1 24,5 26,0 28,6 31,2 33,6 36,8 41,1 19,6 21,1 22,8 24,2 25,6 27,2 29,8 32,3 34,7 37,9 42,3 20,8 22,5 24,1 25,6 27,0 28,6 31,0 33,6 36,1 39,3 43,7 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 24,8 26,5 28,1 29,6 31,0 32,6 35,0 37,6 41,1 44,3 48,7 28,3 30,0 31,8 33,3 34,8 36,4 39,0 41,9 45,5 48,9 53,5 1024 1256 1554 1813 2112 2489 3092 3760 4649 5765 7302 339 360 381 399 418 437 468 502 546 587 642 RE4H1(AR)R 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 38,8 43,1 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 39,9 44,3 22,7 24,4 26,0 27,5 28,8 30,5 32,9 35,5 38,0 41,2 45,6 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 26,7 28,4 30,0 31,5 32,8 34,5 36,9 39,5 43,0 46,2 50,6 30,2 32,1 33,7 35,3 36,7 38,5 41,1 43,8 47,4 51,0 55,6 1109 1358 1650 1928 2216 2617 3226 3884 4783 5933 7482 RE4H1(AR)R 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 18/30 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 8,1 9,8 11,4 12,9 14,2 15,8 18,2 20,5 22,9 26,2 29,9 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 25,4 26,9 28,8 30,1 31,5 33,0 35,6 38,2 40,6 43,8 48,1 26,5 28,1 29,8 31,2 32,6 34,2 36,8 39,3 41,7 44,9 49,3 27,4 29,1 30,7 32,2 33,6 35,2 37,6 40,3 42,7 46,0 50,3 2,0 2,0 2,0 2,0 2,0 2,5 2,5 2,5 2,5 2,5 2,5 31,4 33,1 34,7 36,2 37,6 40,2 42,6 45,3 47,7 51,0 55,3 35,3 37,2 38,8 40,4 41,8 44,6 47,0 49,9 52,5 55,9 60,5 1371 1640 1944 2242 2535 2999 3617 4313 5185 6344 7914 (kg/km) (mm) (Ω/km) (A) (A) 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 277 338 389 442 507 602 693 794 922 1066 261 312 355 398 446 516 582 655 741 832 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,50 0,55 0,61 0,70 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 226 281 343 392 447 510 607 696 796 923 1067 213 261 312 355 398 445 516 582 659 741 833 0,14 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,10 0,20 0,22 0,25 0,27 0,29 0,32 0,36 0,40 0,43 0,48 0,55 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 231 286 348 398 452 517 613 702 803 930 1074 213 261 312 355 398 446 517 583 657 742 836 362 385 404 424 440 462 493 525 569 612 667 0,14 0,13 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,10 0,10 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 0,41 0,46 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 234 289 352 402 457 521 617 707 807 935 1080 213 261 312 355 397 446 517 583 658 744 838 423 446 465 485 501 535 564 598 630 671 726 0,15 0,14 0,14 0,13 0,13 0,12 0,12 0,11 0,11 0,11 0,10 0,14 0,15 0,17 0,18 0,19 0,21 0,23 0,25 0,27 0,30 0,34 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 240 295 359 409 464 529 624 714 816 943 1089 213 261 312 355 397 446 520 584 659 747 843 (µF/km) (kA/sec) ( ) * trefoil formation 145 Power cables TEPLA Plant & Petrochem Cables TEPLA M - S(AR) (XLPE/CuW/PSA/PVC) multi-core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > > Applicable standards IEC 60502-2 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-001 for PSA layer r IEC 60332-1 146 STANDARD EXCELLENT 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Fillers non hygroscopic compound Mechanical protective layer PSA AIR BAGTM Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” 12 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - S(AR) from 3,6/6 (7,2) to 18/30 (36) kV (XLPE/CuW/PSA/PVC) - multi-core Type Phase Voltage Cross Diameter Maximum Diameter Diameter Diameter Approx Diameter Outer Weight Min Max Phase Conductor Max DC current current over over under thickness over diameter of cable bending reactance capacity short of section 50Hz approx circuit carrying carrying PSA approx approx radius PSA of conductor resistance insulation screen approx at 20 °C approx approx current capacity capacity PSA in air in ground 30 °C (T 20 °C, single core depth 1 in trefoil m, gtr format) Km/W) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (mm) (mm) (kg/km) (mm) RE4H1O(AR)R 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3,6/6 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 13,2 14,4 15,9 17,6 19,1 20,5 22,0 24,8 27,8 14,4 15,6 17,1 18,8 20,3 21,7 23,2 26,0 28,9 32,0 34,2 37,9 41,3 44,6 47,5 50,9 56,5 63,0 2,0 2,0 2,5 2,5 2,5 2,5 3,0 3,0 3,0 36 38,2 42,9 46,3 49,6 52,5 56,9 62,5 69,0 40,1 42,5 47,3 51,1 54,5 57,6 62,3 68,2 75,1 2492 2987 3854 4873 5807 6800 8166 10285 12733 481 510 568 614 654 692 747 818 901 0,11 0,10 0,09 0,09 0,09 0,09 0,08 0,08 0,08 0,28 0,31 0,35 0,40 0,44 0,47 0,52 0,57 0,59 RE4H1O(AR)R 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 35,7 37,9 41,6 45,0 48,2 51,1 54,6 59,7 2,5 2,5 2,5 2,5 2,5 3,0 3,0 3,0 40,7 42,9 46,6 50,0 53,2 57,1 60,6 65,7 45,1 47,5 51,3 55,0 58,4 62,5 66,1 71,7 2895 3405 4263 5288 6249 7329 8650 10770 541 570 616 660 701 750 793 860 0,11 0,11 0,10 0,10 0,09 0,09 0,09 0,09 RE4H1O(AR)R 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 8,7/15 3x35 3x50 3x70 3x95 3x120 3x150 3x185 7,0 8,2 9,7 11,4 12,9 14,3 15,8 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 17,2 18,4 19,9 21,6 23,1 24,5 26,0 18,4 19,6 21,1 22,8 24,2 25,6 27,2 40,1 46,0 49,5 52,7 55,6 59,0 64,2 2,5 3,63 2,5 2,5 3,0 3,0 3,0 45,1 47,4 51,0 54,5 58,7 61,6 65,0 49,9 52,3 56,2 59,8 64,3 67,3 71,0 3359 3900 4798 5856 6919 7952 9324 599 628 674 718 771 808 852 RE4H1O(AR)R 12/20 12/20 12/20 12/20 12/20 12/20 12/20 3x35 3x50 3x70 3x95 3x120 3x150 3x185 7,0 8,2 9,7 11,4 12,9 14,3 15,8 0,52 0,39 0,27 0,19 0,15 0,12 0,1,0 19,2 20,4 21,9 23,6 25,1 26,5 28,0 20,4 21,6 23,1 24,8 26,2 27,6 29,2 44,2 46,4 50,1 53,6 56,8 59,7 63,1 2,5 2,5 3,0 3,0 3,0 3,0 3,0 49,2 51,4 56,1 59,6 62,8 65,7 69,1 54,2 56,6 61,5 65,1 68,5 71,6 75,4 3810 4374 5364 6460 7471 8548 9984 RE4H1O(AR)R 18/30 3X50 18/30 3X70 8,1 9,8 0,39 0,27 25,4 26,9 26,5 28,1 56,6 60,3 3,0 3,0 62,6 66,3 68,5 72,4 5814 6826 (kV) (Ω/km) (µF/km) (kA/sec) (A) (A) 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43 165 196 245 298 344 391 447 527 602 172 201 246 294 333 374 421 486 545 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 167 199 248 301 347 394 449 529 171 201 246 294 333 373 420 486 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,18 0,20 0,22 0,25 0,27 0,29 0,32 5,0 7,2 10,0 13,6 17,2 21,5 26,5 169 202 252 305 350 396 531 170 201 246 294 333 372 421 650 679 737 781 822 859 905 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,16 0,17 0,19 0,22 0,24 0,25 0,27 5,0 7,2 10,0 13,6 17,2 21,5 26,5 172 204 253 308 353 399 454 170 201 246 294 332 372 419 822 868 0,13 0,13 0,14 0,15 7,2 10,0 207 257 200 244 147 Power cables TEPLA Plant & Petrochem Cables TEPLA M - L (XLPE/Pb/PVC) single core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > Applicable standards IEC 60332-1 148 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic sheath lead alloy Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” IEC 60502-2 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - L from 3,6/6 (7,2) to 18/30 (36) kV (XLPE/Pb/PVC) - single core Diameter Maximum Diameter Diameter DC of over over conductor resistance insulation screen at 20 °C approx approx Max Phase Conductor current capacity short carrying approx circuit current capacity in air 30 °C (single core in trefoil format) (µF/km) (kA/sec) (A) Outer diameter approx Weight of cable approx Min bending radius Phase reactance at 50 Hz approx (*) (mm) (mm) (kg/km) (mm) (Ω/km) 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 34,6 38,9 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 35,7 40,1 21,5 22,6 24,7 26,3 28,2 29,5 31,5 34,1 36,9 40,0 43,6 48,1 1385 1566 1943 2290 2713 3053 3607 4322 5203 6309 7736 9509 344 361 394 420 450 472 504 545 591 639 697 770 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,10 0,09 0,09 0,09 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,5 0,55 0,61 0,70 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 194 232 292 357 413 470 539 635 732 846 971 1112 189 224 274 328 373 419 471 541 610 684 772 859 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 38,8 43,1 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 39,9 44,3 25,9 27,3 29,0 31,0 32,5 34,0 35,8 38,4 41,5 44,3 47,9 52,7 1795 2084 2398 2872 3214 3583 4155 4893 5836 6965 8442 10428 414 437 464 496 520 545 573 615 664 709 767 843 0,14 0,13 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,10 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 0,41 0,46 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 201 241 300 366 423 481 551 645 743 857 983 1125 189 224 274 329 373 418 472 542 611 686 776 865 Voltage Cross section (kV) (mm2) (mm) (Ω/km) (mm) RE4LR 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 RE4LR 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 Type* Max current carrying capacity in ground (T 20 °C, depth 1 m, gtr Km/W) (A) ( ) * trefoil formation 149 Power cables TEPLA Plant & Petrochem Cables TEPLA M - SL (XLPE/CuT/Pb/PVC) multi-core from 3,6/6 (7,2) kV to18/30 (36) kV Construction > > > > > > > > > Applicable standards IEC 60332-1 150 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Fillers non hygroscopic compound Metallic sheath lead alloy Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” IEC 60502-2 IEC 60228 IEC 60332-1 Design and tests guidelines Conductors Flame retardant r 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE 16 D technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - SL from 3,6/6 (7,2) to 18/30 (36) kV (XLPE/CuT/Pb/PVC) - multi-core Type Voltage Cross Diameter Maximum Diameter Diameter Diameter Outer DC section of over over over diameter conductor resistance insulation screen extruded approx at 20 °C approx approx inner covering Weight of cable approx Phase Min Phase Conductor Max Max bending reactance capacity short current current radius at 50 Hz approx circuit carrying carrying approx current capacity capacity in air in 30 °C ground (single (T 20 °C, core in depth 1 trefoil m, gtr format) Km/W) (Ω/km) (µF/km) (kA/sec) (mm) (A) (A) (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) (kg/km) 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,00754 0,0601 0,0470 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 36,6 39,0 42,4 46,0 49,2 52,6 55,8 61,4 66,9 72,5 46,0 48,7 52,7 56,7 60,4 63,7 67,5 73,2 80,1 86,4 5439 6264 7534 9018 10421 11873 13694 16503 19821 23839 737 779 844 908 966 1019 1080 1172 1282 1382 0,11 0,11 0,10 0,10 0,09 0,09 0,09 0,09 0,08 0,08 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,50 0,55 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 184 218 271 327 374 423 482 563 635 717 181 212 259 308 348 389 439 501 557 620 RE4H1OLR 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,2 9,7 11,4 12,9 14,3 15,8 18,4 20,6 23,0 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,00754 0,0601 0,0470 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 45,6 48,1 51,4 55,4 58,5 61,5 64,9 70,5 76,4 81,5 55,9 58,6 62,6 66,5 69,9 73,2 77,8 83,7 90,4 96,5 7472 8409 9823 11418 12703 14267 16452 19722 23202 27420 895 937 1002 1064 1118 1171 1244 1340 1447 1544 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 187 222 275 331 379 426 485 564 635 717 180 212 258 307 347 386 436 498 557 620 RE4H1OLR 151 Power cables TEPLA Plant & Petrochem Cables TEPLA M - D (XLPE/DRYLAM/PVC) single core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > Applicable standards IEC 60502-2 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-003 for chemical moisture barrier r IEC 60332-1 152 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Chemical moisture barrier longitudinally applied Al tape bonded with extruded chemical resistant polymeric layer Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa ,6/6 kV” 14 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - D from 3,6/6 (7,2) to 18/30 (36) kV (XLPE/DRYLAM/PVC) - single core Type* Diameter Maximum Diameter Diameter DC of over over conductor resistance insulation screen at 20 °C approx approx Max Phase Conductor current capacity short carrying approx circuit current capacity in air 30 °C (single core in trefoil format) (µF/km) (kA/sec) (A) Outer diameter approx Weight of cable approx Min bending radius Phase reactance at 50 Hz approx (*) (mm) (mm) (kg/km) (mm) (Ω/km) 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 34,6 38,9 16,2 17,4 18,9 20,6 22,1 23,5 25,0 27,6 30,1 32,5 35,7 40,1 21,5 22,5 24,4 26,0 27,7 29,0 30,8 33,4 36,2 39,1 42,5 47,0 691 829 1059 1334 1601 1875 2254 2842 3479 4322 5415 6915 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,09 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,50 0,55 0,61 0,70 5,0 7,2 10 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 189 226 284 347 401 457 524 623 714 824 951 1091 186 219 269 321 366 410 462 532 600 679 766 855 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 38,8 43,1 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 39,9 44,3 25,6 26,9 28,6 30,3 31,8 33,4 35,0 37,7 40,6 43,2 46,7 51,2 857 1014 1245 1543 1806 2105 2479 3096 3758 4600 5718 7248 0,14 0,13 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 0,41 0,46 5,0 7,2 10 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 >50,0 >50,0 196 234 292 356 411 467 535 633 725 835 963 1104 186 219 269 322 366 409 463 533 601 681 768 860 Voltage Cross section (kV) (mm2) (mm) (Ω/km) (mm) RE4H5R4R 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 RE4H5R4R 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 1x300 1x400 1x500 1x630 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 26,2 29,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 Max current carrying capacity in ground (T 20 °C, depth 1 m, gtr Km/W) (A) ( ) * trefoil formation 153 Power cables TEPLA Plant & Petrochem Cables TEPLA M - SD (XLPE/CuT/DRYLAM/PVC) multi-core from 3,6/6 (7,2) kV to 18/30 (36) kV Construction > > > > > > > > > Applicable standards IEC 60502-2 Design and tests guidelines IEC 60228 Conductors IEC 60332-1 Flame retardant Prysmian document GPD-003 for chemical moisture barrier r IEC 60332-1 154 EXCELLENT STANDARD 0 °C Conductor bare copper circular stranded, according to class 2 of IEC 60228 Semiconducting layer extruded compound Insulation XLPE compound Semiconducting layer extruded compound Metallic screen copper tapes Fillers penetrating non hygroscopic compound Chemical moisture barrier longitudinally applied Al tape bonded with extruded chemical resistant polymeric layer Sheath PVC compound ST2 quality Marking e. g. : “PRYSMIAN year - n x csa 3,6/6 kV” 14 D Pb 90°C 250°C NORMAL OPERATION TEMPERATURE SHORT CIRCUIT TEMPERATURE technergy TM INTEGRATED CABLING SOLUTIONS > Power cables according to IEC 60502-2 > Flame retardant cables according to IEC 60332-1 TEPLA M - SD from 3,6/6 (7,2) to18/30 (36) kV (XLPE/CuT/DRYLAM/PVC) - multi-core (kV) (mm2) (mm) (Ω/km) (mm) (mm) (mm) (mm) Phase Min Phase Conductor Max Max bending reactance capacity short current current radius at 50 Hz approx circuit carrying carrying approx current capacity capacity in air in 30 °C ground (single (T 20 °C, core in depth 1 trefoil m, gtr format) Km/W) (Ω/km) (µF/km) (kA/sec) (kg/km) (mm) (A) (A) RE4H1OH5R4R 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 6/10 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,1 9,8 11,4 12,9 14,3 15,7 18,4 20,5 22,9 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 14,0 16,2 17,7 19,4 20,9 22,3 23,8 26,4 29,0 31,4 16,2 17,4 18,9 20,6 22,1 23,5 25 27,6 30,1 32,5 36,6 39,0 42,4 46,0 49,2 52,6 55,8 61,4 66,9 72,5 43,4 45,8 49,6 53,3 57,3 60,4 64,0 69,4 75,6 81,3 2796 3304 4133 5137 6157 7156 8449 10500 12838 15692 610 640 700 750 800 850 900 970 1060 1140 0,11 0,11 0,10 0,10 0,09 0,09 0,09 0,09 0,08 0,08 0,20 0,25 0,28 0,31 0,34 0,37 0,40 0,45 0,50 0,55 5,0 7,2 10,0 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 190 213 265 320 366 414 473 552 630 717 181 212 259 308 348 389 435 501 560 628 RE4H1OH5R4R 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 12/20 3x35 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x300 3x400 7,0 8,2 9,7 11,4 12,9 14,3 15,8 18,4 20,6 23,0 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 19,2 20,4 21,9 23,6 25,1 26,5 28,0 30,6 33,2 35,6 20,4 21,6 23,1 24,8 26,2 27,6 29,2 31,8 34,3 36,7 45,6 48,1 51,4 55,4 58,5 61,5 64,9 70,5 76,4 81,5 52,5 55,3 59,2 63,0 66,4 69,5 73,3 78,8 84,7 90,5 3660 4268 5166 6263 7250 8304 9710 11882 14252 17229 720 750 800 860 910 950 1000 1090 1170 1250 0,13 0,12 0,11 0,11 0,10 0,10 0,10 0,09 0,09 0,09 0,16 0,17 0,19 0,22 0,24 0,25 0,27 0,30 0,34 0,37 5,0 7,2 10 13,6 17,2 21,5 26,5 34,4 43,0 >50,0 183 217 269 324 371 417 476 553 630 717 180 212 258 307 347 386 432 498 560 628 Type Voltage Cross Diameter Maximum Diameter Diameter Diameter Outer Weight DC section of over over over diameter of conductor resistance insulation screen extruded approx cable at 20 °C approx approx inner approx covering 155 Notes 156 TEPLA Plant & Petrochem Cables technergy TM INTEGRATED CABLING SOLUTIONS 157 Notes 158 TEPLA Plant & Petrochem Cables technergy TM INTEGRATED CABLING SOLUTIONS 159 TEPLA Plant & Petrochem Cables Prysmian TechnergyTM Plant & Petrochem Cables General Catalogue, April 2007. Prysmian reserves the right to modify at any time the technical, dimensional and weight characteristics shown in this catalogue anyhow always in accordance to the mentioned Standards in case it improves the features of its products. There is no responsibility of the manufacturer for damages to persons and property in case of improper use and/or neglecting the recommendations for using cables and norms, contained in this catalogue, relevant to installation and operation in plant and petrochem applications. 160 technergy INTEGRATED CABLING SOLUTIONS TM HONG KONG Prysmian Cable Systems Pte. Ltd. Unit A, 18/F, China Overseas Building 139 Hennessy Road Wanchai, Hong Kong tel. +85 2 2827 8308 fax +85 2 2827 7212 AUSTRALIA Prysmian Power Cables & Systems Australia PTY LTD 1 Heathcote Road Locked Bag 7042, Liverpool Business Centre 1871 NSW tel. +61 2 96000 777 fax +61 2 96000 747 HUNGARY Prysmian MKM Magyar Hungarian Cable Works Co. Ltd. Baràzda u. 38 H-1116 Budapest tel. +36 1 3822222 fax +36 1 3822202 AUSTRIA Prysmian OEKW GmbH Lembockgasse 47A, 1230 Wien tel. +43 1 866770 fax +43 1 86677109 BRAZIL Prysmian Energia Cabos e Sistemas do Brasil S. A. Av. Alexandre de Gusmao 145 09110-900 Santo André - SP tel. +55 11 49984000 fax +55 11 49984811 CHINA Prysmian Tianjin Cables Co. Ltd. 513, Huang He Road, Nankai District Tianjin, 300112 tel. +86 22 2753 9679 fax +86 22 2753 3485 EGYPT Prysmian Cables & Systems 8 Abd El Azim Aoudallah st. Hegaz sq. Heliopolis - Cairo tel. +20 2 2418557 fax +20 2 6381327 FINLAND Prysmian Cables & Systems Oy P.O. Box 13 FIN-02401 Kirkkonummi tel. +358 10 77551 fax +358 9 2982204 FRANCE Prysmian Energie Cables et Systèmes France s.a. 19, Avenue de la Paix - BP 712 Paron - 89100, Sens Cedex tel. +33 3 86957769 fax +33 3 86957781 GERMANY Prysmian Kabel und Systeme GmbH Austrasse 99 96465 Neustadt bei Coburg tel. +49 9568 895 1000 fax +49 30 3675 6000 INDONESIA PT. Prysmian Cables Indonesia Gedung BRI II, Suite 1502 Jln. Jend Sudirman No 44-46 Jakarta 10210 tel. +62 264 351222 fax +62 264 351780 ITALY Prysmian Cavi e Sistemi Energia Italia Srl Viale Sarca 222, 20126 Milano tel. +39 02 6449 8108 fax +39 02 6440 8108 MALAYSIA Prysmian Cable Systems Pte. Ltd. Power Cable Malaysia Sdn Bhdn Lot 2 Jalan Kawat 15/18 40702 Shah Alam, Selangor Darul Ehsan tel. +60 3 5518 4528 fax +60 3 5511 9590 NETHERLANDS Prysmian Cables and Systems B.V. Schieweg 9, 2627 AN Delft P.O. Box 495, 2600 AL Delft The Netherlands tel. +31 15 260 5260 fax +31 15 261 3808 NORTH AMERICA Prysmian Cables & Systems North America 700 Industrial Drive Lexington, SC 29072 - USA tel. +1 803 9511130 fax +1 803 9511092 NORWAY Prysmian Kabler og Systmer AS P.O.Box 1384, N - 1401 Ski tel. +47 64 915713 fax +47 64 915714 ROMANIA Prysmian Cabluri si Sisteme SA Soseaua Draganesti, Km. 4 - 0500 Slatina tel. +40 49 435699 fax +40 49 433484 RUSSIA Prysmian Cables and Systems 6th street 8 Marta, 6a, bldg 1 Moscow 125167 tel. +7 095 9337036 fax +7 095 9337035 SINGAPORE Prysmian Cable Systems Pte. Ltd. No 4 Tuas Avenue 12. 3rd Storey 639047 Singapore tel. +65 6862 9866 fax +65 6862 9877 SLOVAKIA Prysmian Kablo s.r.o. Trnavska cesta 50 821 02 Bratislava tel. +421 2 4949 1215 fax +421 2 4949 1248 SPAIN Prysmian Cables y Sistemas S.L. Carretera C-15, Km. 2 08800 Vilanova i la Geltrú (Barcelona) tel. +34 93 811 6181 fax +34 93 811 6011 SWEDEN Prysmian Kablar och System AB Turebergs Allé 2 SE-19162 Sollentuna tel. +46 8 260416 fax +46 8 260413 THAILAND Prysmian Cable Systems Pte Ltd. 555 RASA Tower 11th Floor Phaholyothin Road, Lardyao Chatuchak - Bangkok 10900 tel. +66 2 937 0316 fax +66 2 937 0318 TURKEY Turk Prysmian Kablo ve Sistemleri A.S. Buyukdere Caddesi No 117 34394 Gayrettepe Istanbul tel. +90 212 3551500 fax +90 212 2175810 U.A.E. (Dubai) Prysmian Cabels and Systems Middle East P.O. Box 72125, Dubai tel. +971 4 345 7870 fax +971 4 345 7101 UK Prysmian Cables and Systems Ltd. Chickenhall Lane Eastleigh Hampshire, SO50 6YU tel. +44 2380 295555 fax +44 2380 295111 World Wide Excellence Center 4 tel. +39 02 6449 8108, fax +39 02 6440 8108 Head Office Prysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com dega design group ARGENTINA Prysmian Energía Cables y Sistemas de Argentina S. A. Fábrica La Rosa, Av. da Argentina 6784 1439 Capital Federal tel. +54 11 46302000 fax +54 11 46302100