Istruzioni per l'uso per il tecnico autorizzato Termopompe acqua glicolata-acqua e acqua-acqua HP GEO /HP GEO R Modelli pompe di calore 20021162 HP GEO 05M.MT 20021170 HP GEO 12T.MT 20021180 HP GEO 35T.HT1 20021188 HP GEO R 08/08T.MT 20021163 HP GEO 06M.MT 20021164 HP GEO 08M.MT 20021172 HP GEO 14T.MT 20021173 HP GEO 07M.HT2 20021181 HP GEO 43T.HT1 20021189 HP GEO R 10/09T.MT 20021182 HP GEO R 05/05M.MT 20021190 HP GEO R 12/12T.MT 20021165 20034361 HP GEO 10M.MT 20021174 HP GEO 12M.MT 20021175 HP GEO 11M.HT2 20021183 HP GEO R 06/06M.MT 20021191 HP GEO R 14/12T.MT HP GEO 07T.HT2 20021184 HP GEO R 08/08M.MT 20021192 HP GEO R 17/16T.HT1 20021166 HP GEO 05T.MT 20021176 HP GEO 11T.HT2 20021185 HP GEO R 10/09M.MT 20021193 HP GEO R 22/21T.HT1 20021167 20021168 HP GEO 06T.MT 20021177 HP GEO 17T.HT1 20034362 HP GEO R 12/11M.MT 20021194 HP GEO R 28/30T.HT1 HP GEO 08T.MT 20021178 HP GEO 22T.HT1 20021186 HP GEO R 05/05T.MT 20021195 HP GEO R 35/35T.HT1 20021169 HP GEO 10T.MT 20021179 HP GEO 28T.HT1 20021187 HP GEO R 06/06T.MT 20021196 HP GEO R 43/45T.HT1 10/2010 Art. n. 420010348800 Indice Indice …………………………………………………....... 2 Legenda ........................................................................... 3 Fondamenti Avvertenze di sicurezza……………………......... In generale......................................................... Prescrizioni e direttive vincolanti........................ Condizioni di garanzia........................................ Controllo in entrata............................................. 4 5 6 6 6 Dotazione........................................................... Trasporto e collocazione.................................... Raccordi idraulici................................................ 7 8 9 Tubi flessibili...................................................... Unità di comando............................................... 10 12 Raccordo lato sorgente fredda........................... Raccordo lato riscaldamento.............................. 13 15 In generale......................................................... Struttura apparecchio, assegnazione morsetti... Scatola elettrica.................................................. 18 19 23 Problematica...................................................... Concentrazione sbagliata di glicole.................... Lavaggio............................................................. Riempimento con antigelo.................................. Corretto riempimento di un circuito sonda Geotermica………………………………………... 26 26 26 27 27 Eliminazione guasti Eliminazione guasti HP GEO.............................. 29 Verbale di messa in servizio Lista di controllo HP GEO................................... 32 Impianto Dati caratteristici sonde NTC 1 k........................ Dati caratteristici sonde NTC 10 k...................... 34 34 Dimensioni degli apparecchi HP GEO 05T.MT - 17T.HT1............................... HP GEO 22T.HT2 - 43T.HT1............................ . 35 36 Dati tecnici HP GEO 05T.MT - 08T.MT................................ HP GEO 10T.MT - 14T.MT................................ HP GEO 07T.HT2 - 11T.HT2............................. HP GEO 17T.HT1.............................................. HP GEO 22T.HT1 - 43T.HT1............................. HP GEO 05M.MT 08M.MT................................. HP GEO 10M.MT - 12M.MT............................... HP GEO 07ACMHT............................................ HP GEO R 05/05T.MT - 08/08T.MT................... HP GEO R 10/09T.MT - 14/12T.MT................... HP GEO R 05/05M.MT - 08/08M.MT................. HP GEO R 10/09M.MT - 12/11M.MT................. HP GEO R 17/126T.HT1................................... HP GEO R 22/21T.HT1 - 43/45T.HT1............... 37 39 41 43 45 47 49 51 53 55 57 59 61 63 Dichiarazione di conformità ........................................................................... 65 Annotazioni ........................................................................... 73 Istruzioni per l'installazione e il raccordo Montaggio Istruzioni per l'installazione e il raccordo Allacciamento elettrico Riempimento di impianti a sonde geotermiche 2 Legenda HP GEO La designazione pompa di calore acqua glicolata-acqua e acqua-acqua HP GEO comprende i modelli descritti qui di seguito: HP GEO ..T.MT La designazione HP GEO ..T.MT comprende i seguenti modelli: • HP GEO ..T.MT • HP GEO ..T.HT1 • HP GEO R ../..T.MT • HP GEO R ../..T.HT1 • HP GEO ..M.MT • HP GEO R ../..M.MT Modelli compatti HP GEO ..T.MT Fino ai modelli HP GEO 14T.MT e 17T.HT1 le termopompe sono in esecuzione compatta, con integrati il vaso di espansione, le pompe di circolazione lato sorgente e lato riscaldamento e una resistenza elettrica per il regime di emergenza. Termopompe ad alta temperatura HP GEO ..T.HT1 HP GEO 17T.HT1 - HP GEO 43T.HT1 Le termopompe ad alta temperatura raggiungono una temperatura di mandata di 65 °C. Per gli altri modelli la temperatura di mandata è di 55 °C. Modelli monofase ..M.MT Fino al modello HP GEO 12M.MT e HP GEO R 12/11M.MT sono disponibili anche esecuzioni Monofase (1x230 VAC). Tutti gli altri modelli sono trifase (3x400 VAC). Modelli reversibili HP GEO R Le termopompe reversibili possono essere utilizzate, oltre che per il riscaldamento, anche per il raffrescamento attivo. 3 Fondamenti Avvertenze di sicurezza Avvertenze di sicurezza Nelle istruzioni per l'uso si utilizzano in generale i seguenti simboli. L E Indicazioni sull'impiego e sul funzionamento I componenti e i tubi lato evaporatore non devono assolutamente essere utilizzati per il trasporto. Avvertenze di sicurezza, da osservare in ogni caso E Riferimenti alle istruzioni per l'uso Regolatore RVS 61 E La collocazione, l'installazione, l'allacciamento e la messa in servizio della termopompa devono essere effettuati da uno specialista qualificato nel rispetto delle prescrizioni legali, delle ordinanze e delle direttive vigenti e in conformità alle istruzioni per l'uso. E L'impiego della termopompa deve essere notificato all'azienda locale di approvvigionamento di energia. E Durante il trasporto, la termopompa può essere inclinata al massimo di 30°. Evitare qualsiasi esposizione della termopompa all’acqua o all’umidità. La termopompa per riscaldamento va protetta dai danni e dallo sporco, in particolare durante la fase cantieristica. 4 E La termopompa è fissata alla paletta di legno. E Prima di aprire l'apparecchio si deve interrompere l'alimentazione di tutti i circuiti elettrici. E Gli interventi sul circuito frigorifero possono essere effettuati solo da personale competente con formazione ed esperienza specifiche sui rischi legati all'uso di refrigeranti. L Non utilizzare prodotti abrasivi, detergenti acidi o contenenti cloro per pulire le superfici dell'apparecchio. Fondamenti In generale In generale Ambiti di impiego La termopompa HP GEO è concepita esclusivamente per scaldare l'acqua di riscaldamento e l'acqua sanitaria. Con la termopompa reversibile della famiglia HP GEO R è possibile anche un raffrescamento passivo. Tenuto conto dei limiti di impiego (vedi documentazione di progettazione HP GEO), la termopompa può essere utilizzata in impianti di riscaldamento nuovi o esistenti. E Collocazione Le termopompe possono essere collocate anche senza zoccolo su una superficie piana, portante, liscia e orizzontale. Il locale di installazione deve essere asciutto e protetto dal gelo. Gli ambienti con elevata umidità dell’aria, come lavanderie, sono limitatamente idonei. Le distanze minime per la manutenzione e il servizio devono essere rispettate con tutti gli apparecchi. Funzionamento della termopompa acqua glicolata-acqua e acqua-acqua Regime riscaldamento La termopompa trasforma il calore a bassa temperatura presente nel terreno (acqua di falda) in calore ad alta temperatura. A tale scopo, l'acqua glicolata che preleva calore dal terreno (acqua di falda) attraverso le superfici di scambio termico viene convogliata tramite una pompa nell'evaporatore, dove si trova il fluido di lavoro che presenta un punto di ebollizione molto basso in condizioni di bassa pressione. Il calore necessario all'evaporazione del fluido è prelevato dall'acqua glicolata, che viene quindi convogliata nuovamente verso lo scambiatore di calore. Il fluido di lavoro evaporato è aspirato dal compressore, dove viene portato ad una pressione più alta. Il fluido gassoso compresso è convogliato nel condensatore, dove diventa nuovamente liquido in condizioni di pressione e di temperatura elevate. Il calore di condensazione viene trasmesso all'acqua di riscaldamento, la cui temperatura aumenta. L'energia trasmessa all'acqua di riscaldamento è pari a quella prelevata dal terreno (acqua di falda) più una quota minima di energia elettrica necessaria per la compressione del fluido di lavoro. Regime raffreddamento Freecooling o raffrescamento passivo Un clima interno gradevole anche in estate acquista un'importanza sempre maggiore, soprattutto nelle nuove costruzioni. Con il Freecooling, il calore ambiente in eccesso viene ceduto direttamente alla sonda geotermica o all'acqua di falda tramite uno scambiatore. Per questo tipo di raffrescamento, il circuito frigorifero della termopompa stessa non è in funzione. La potenza frigorifera è ottenuta esclusivamente tramite scambio termico tra sorgente fredda e sistema di distribuzione, grazie a uno scambiatore supplementare. La pompa sorgente e la pompa circuito frigorifero (= pompa circuito riscaldamento) sono in funzione. Con effetto immediato ai clienti è ora possibile offrire un set Freecooling opzionale in combinazione con le termopompe HP GEO 05T.MT - 14T.MT. Raffrescamento attivo con HP GEO R Con le termopompe reversibili HP GEO R in combinazione con un sistema di distribuzione adatto per riscaldamento e raffreddamento (p.e. fan coil) si ottiene una potenza frigorifera definita attraverso il raffrescamento attivo. A differenza del Freecooling, il compressore della termopompa è in funzione (inversione del circuito frigorifero). In regime raffrescamento, il processo risulta invertito. Il lato di cessione del calore (condensatore) diventa lato di assorbimento termico (evaporatore). In questa fase, la termopompa funziona come un frigorifero. Regime raffrescamento e regime riscaldamento non possono essere attivi contemporaneamente. Affinché la termopompa non sia soggetta a eccessivi inserimenti, disinserimenti e commutazioni su produzione ACS, si raccomanda in ogni caso l'utilizzo di un accumulatore del freddo. A seconda del tipo di impianto, a tale scopo si presta anche l'accumulatore per riscaldamento. Cascata Grazie al nuovo regolatore per termopompe RVS 61 è possibile combinare e gestire in cascata più generatori di calore in un impianto. Il regolatore RVS 61 consente di realizzare senza problemi sistemi in cascata per max. 15 termopompe. Nel funzionamento in cascata di un impianto, i generatori vengono inseriti o disinseriti in funzione del momentaneo fabbisogno di energia. Se con la termopompa in funzione non è possibile soddisfare entro un determinato lasso di tempo il fabbisogno di energia richiesto si inserisce un'ulteriore termopompa (generatore di calore). Impiego a basso consumo di energia del riscaldamento con termopompa La decisione di optare per un riscaldamento con termopompa rappresenta un prezioso contributo alla salvaguardia dell'ambiente attraverso la riduzione delle emissioni e l'impiego ridotto di energia primaria. Affinché il nuovo sistema di riscaldamento possa funzionare in modo efficiente, osservare i seguenti punti: L L'impianto di riscaldamento con termopompa deve essere dimensionato e installato con cura. L Evitare temperature di mandata eccessivamente elevate. Tanto più bassa è la temperatura di mandata lato acqua di riscaldamento, quanto più efficiente è il funzionamento della termopompa. Osservare la corretta impostazione del regolatore. L Dare la preferenza a un arieggiamento intenso di breve durata dei locali. Rispetto alle finestre sempre aperte in posizione ribaltata, questa ventilazione immediata riduce il consumo di energia. 5 Fondamenti Prescrizioni e direttive vincolanti Condizioni di garanzia Controllo in entrata Indicazioni generali I calcoli, i dimensionamenti, le installazioni e le messe in servizio legate ai prodotti descritti nel presente documento possono essere eseguite esclusivamente da specialisti qualificati. Osservare le prescrizioni di legge locali, che possono scostarsi dalle indicazioni riportate nel presente documento. Con riserva di modifiche. Le presenti istruzioni servono per una corretta installazione, regolazione e manutenzione dell'apparecchio. È pertanto indispensabile leggere attentamente le indicazioni riportate qui di seguito e far installare, collaudare e sottoporre a manutenzione la termopompa da parte di tecnici qualificati con formazione specifica. Al termine del periodo di garanzia, il fabbricante declina ogni responsabilità per modifiche meccaniche, idrauliche o elettriche. In caso di interventi non espressamente autorizzati, eseguiti in violazione delle presenti istruzioni, la garanzia decade con effetto immediato. Durante l'installazione devono essere rispettate le norme di sicurezza specifiche di esercizio. Verificare che le caratteristiche della rete elettrica corrispondano ai dati della termopompa (targhetta di identificazione). Le presenti istruzioni e lo schema elettrico della termopompa devono essere conservate con la dovuta cura e, se necessario, messe a disposizione del personale incaricato. E Il fabbricante declina qualsiasi responsabilità per danni alle persone o alle cose causati direttamente o indirettamente dalla mancata osservanza delle presenti istruzioni. Il corpo dell'apparecchio può essere aperto solo da un tecnico qualificato. 6 Prescrizioni e direttive vincolanti La costruzione e la fabbricazione della termopompa è conforme a tutte le direttive delle norme europee. (Vedi dichiarazione di conformità CE). L'allacciamento elettrico della termopompa deve essere eseguito in conformità alle relative norme ASE, EN e IEC. Vanno inoltre osservate le condizioni di allacciamento dell'azienda locale di approvvigionamento di energia. E Condizioni di garanzia Le nostre prestazioni di garanzia decadono per danni in seguito a: uso o impiego improprio o non conforme montaggio o messa in servizio errati da parte dell'acquirente o di terzi integrazione di parti di produttori terzi utilizzo dell'impianto con pressioni eccessive o al di fuori dei valori indicati di fabbrica mancata osservanza delle indicazioni riportate nelle istruzioni per l'uso. La garanzia per termopompe da riscaldamento è di 24 mesi a decorrere dal giorno della consegna. Per il resto valgono le condizioni di vendita, di fornitura e di garanzia in base alla conferma d'ordine. Controllo in entrata Gli apparecchi vengono consegnati su una paletta di legno con un adeguato imballaggio di protezione. Al momento della consegna, controllare che l'apparecchio non presenti danni da trasporto e che la dotazione sia completa. E Se si riscontrano dei danni, questi devono essere riportati immediatamente sul documento di trasporto con la seguente indicazione: «Presa in consegna con riserva a causa di danneggiamento palese». Dato che un sovraccarico può causare gravi danni sia alla termopompa, sia all'impianto lato sorgente termica, è vietato mettere in funzione la termopompa se sussistono le seguenti condizioni: essiccazione della costruzione; impianto non ultimato (costruzione grezza); finestre e porte esterne non terminate e chiuse. In questi casi è necessario prevedere un riscaldamento da cantiere. Un riscaldamento funzionale o pronto posa con la termopompa secondo DIN EN 1264 è consentito solo tenendo conto delle suddette condizioni. Inoltre, tenere presente che in seguito al dimensionamento della termopompa per il funzionamento normale può eventualmente non essere possibile generare tutta la potenza termica necessaria. Rispettare anche le seguenti indicazioni: Osservare le norme e le pre scrizioni del fabbricante di malte per massetti! Il corretto funzionamento è possibile solo con un impianto installato a regola d'arte (parte idraulica, parte elettrica, impostazioni)! In caso contrario il massetto potrebbe danneggiarsi! Istruzioni per l'installazione e il raccordo Dotazione I seguenti componenti sono in dotazione alla termopompa: 1 2 3 4 piedini antivibrazioni 8 guarnizioni per tubi flessibili 1 documentazione Tubi flessibili premontati sul lato posteriore Accessori sciolti nell'imballaggio separato HP GEO 05T.MT - 17T.HT1 7 Istruzioni per l'installazione e il raccordo Trasporto e collocazione Trasporto Prima di qualsiasi trasporto ci si deve assicurare che le prestazioni di sollevamento dei mezzi utilizzati siano adeguate per il peso dell'apparecchio. Tutti i lavori descritti qui di seguito devono essere eseguiti in conformità alle norme di sicurezza vigenti, sia in termini di equipaggiamento, sia di procedura. Per il trasporto, utilizzare carrelli elevatori o simili. Inserire longitudinalmente le forche sotto la paletta di legno. Per il sollevamento, osservare la distribuzione uniforme del peso dell'apparecchio. Durante il trasporto, la termopompa non deve essere inclinata di oltre 30° (in ogni direzione). Evitare qualsiasi esposizione della termopompa all’acqua o all’umidità. (Questo vale anche per l'installazione!) Evitare assolutamente di accatastare oggetti o appendere biancheria bagnata sopra la termopompa. 8 Collocazione La termopompa è concepita per l'installazione interna (IPXO, vale a dire solo in ambienti asciutti). Il telaio di base deve poggiare su una superficie piana, liscia e orizzontale. La termopompa deve essere collocata in modo da poter eseguire senza problemi gli interventi di servizio. Questo è garantito se si rispettano le distanze dalle pareti riportate nella figura. Dopo il trasporto nel locale di installazione, togliere le sicurezze per il trasporto. Nelle sedi filettate che si liberano vanno inseriti i «piedini antivibrazioni» in dotazione. Questi piedini servono anche all'allineamento orizzontale della termopompa. La termopompa non deve essere collocata su pavimenti flottanti. Pianta con distanze minime HP GEO ..T.HT1 HP GEO ..T.MT(T.HT1) Istruzioni per l'installazione e il raccordo Trasporto e collocazione Raccordi idraulici Dopo la collocazione definitiva, verificare la presenza di danni visibili. Il materiale d'imballaggio va smaltito a regola d'arte nel rispetto dell'ambiente. Sicurezza per il trasporto 9 Montaggio Tubi flessibili HP GEO 05T.MT - 14T.MT, 17T.HT1 2a 2b (1) - A (2) - B 3a 3b C D A A: Ø=1’’ (DN25) B: Ø=1’’ (DN25) C: Ø=1’’ (DN25) D: Ø=1’’ (DN25) (4) - C B L= 610 mm L= 1240 mm L= 610 mm L= 1240 mm (3) - D Brugola n°3 (M5) 1a 1b (1) - A (1) (4) (2) - B (3) (2) 10 (4) - C (3) - D Montaggio Tubi flessibili HP GEO 22T.HT1 - 43T.HT1 2a 2b (1) - A (2) - C 3a 3b B D A C A: Ø=1 ¼’’ (DN32) L= 900 mm B: Ø=1 ½’’ (DN40) L= 900 mm C: Ø=1 ¼’’ (DN32) L= 1300 mm D: Ø=1 ½’’ (DN40) L= 1300 mm (4) - (3) - Brugola n°3 (M5) 1a 1b (1) - A (4) - B (1) (2) (4) (3) (2) - C (3) - D 11 Montaggio Unità di comando HP GEO 05T.MT - 14T.MT, 17T.HT1, HP GEO 22T.HT1 - 43T.HT1 2 3 A „click“ B 1 A 12 B Istruzioni per l'installazione e il raccordo Raccordo lato sorgente fredda Collegamenti Condotte di collegamento e distributore 7 6 Fornitura/Montaggio Ditta installatrice 8 A cura del committente Scavi e brecce 2 1 4 Profondità delle sonde 3 Raccomandazione: 5% prof. sonda 1 2 3 4 5 6 Valvola a cassetto Pressostato Manometro Vaso di espansione Valvola di sicurezza Valvola di riempimento e scarico 7 Disaeratore manuale 8 Organo di bilanciamento (STAD, Taco-Setter) per sonda e per campo sonda Sonda geotermica Trivellazioni, posa in opera e riempimento Fornitura/Montaggio Ditta di trivellazione A cura del committente Benna per fanghi di trivellazione 5 6 integrati negli apparecchi compatti Raccordo termopompa Pompa di alimentazione sorgente fredda, dispositivi di sicurezza, condotte di collegamento, isolamento, riempimento liquido termovettore Fornitura/Montaggio Ditta installatrice La rappresentazione schematica vale per analogia anche per i collettori interrati. L La pompa di circolazione acqua glicolata è già integrata nella HP GEO ..T.MT. L Posare la condotta di sicurezza in pendenza e portarla fino a un contenitore di raccolta adeguato. 13 Istruzioni per l'installazione e il raccordo Raccordo lato sorgente fredda Acqua (con circuito intermedio) Collegamenti • Condotte di captazione e di reimmissione • Scavi e brecce Fornitura/Montaggio: ditta installatrice, ev. capomastro Circuito intermedio • Pompa acqua-glicolata • Realizzazione del circuito intermedio, incluso riempimento liquido termovettore (miscela antigelo) Sopraelevaz. Livello superiore Platea di calcestruzzo Impermeabilizzazione trivellazione Impianto sorgente fredda • Realizzazione del pozzo di captazione e di reimmissione • Pompa acqua di falda Fornitura/Montaggio: ditta installatrice/ditta di trivellazione L In caso di sfruttamento dell'acqua di falda o di fonte come sorgente fredda, osservare obbligatoriamente quanto segue: temperatura minima >= 7 °C acqua pulita e filtrata; prevedere un filtro nella condotta forzata 14 Termopompa Fornitura/Montaggio: ditta installatrice Legenda 1 Filtro eventuale 2 Valvole a saracinesca 3 Scambiatore intermedio 4 Disaeratore manuale 5 Valvola di riempimento e scarico 6 Valvola di sicurezza 7 Termometro 8 Vaso di espansione 9 Manometro 11 Flussostato 12 Pompa di circolazione 13 Valvola di ritegno 14 Contatore di portata eventuale 15 Valvola di strozzamento 16 Termostato antigelo 17 Pompa sommersa 18 Filtro fine, maglia = 280 - 350 μm L L La pompa di circolazione acqua glicolata è già integrata nella HP GEO ..T.MT. Posare la condotta di sicurezza in pendenza e portarla fino a un contenitore di raccolta adeguato. Istruzioni per l'installazione e il raccordo Raccordo lato riscaldamento HP GEO ..T.MT Legenda 1 Uscita acqua riscaldamento, filetto interno 2 Ingresso acqua riscaldamento, filetto interno 3 Uscita sorgente fredda, filetto interno 4 Ingresso sorgente fredda, filetto interno 5 Alimentazione elettrica 6 Cavo per sonda HP GEO ..T.HT1 15 Istruzioni per l'installazione e il raccordo Raccordo lato riscaldamento In linea di massima si distingue tra concetti base: 2 schemi di base per HP GEO ..T.MT e 1 per HP GEO Schema di base HP GEO ..T.MT a) Raccordo diretto, senza accumulatore tampone; osservare le quantità minime di acqua in circolazione La superficie del registro riscaldante nell'accumulatore ACS deve essere adattata alla potenza della termopompa. b) Raccordo indiretto, con accumulatore tampone per la separazione idraulica La superficie del registro riscaldante nell'accumulatore ACS deve essere adattata alla potenza della termopompa. 16 Istruzioni per l'installazione e il raccordo Raccordo lato riscaldamento Schema di base HP GEO c) Termopompa separata con accumulatore tampone e circuito riscaldamento miscelato. La produzione di acqua calda avviene tramite uno scaldacqua con scambiatore esterno (carico Magro). 17 Allacciamento elettrico In generale E L'allacciamento elettrico della termopompa deve essere eseguito in conformità alle relative norme ASE, EN e IEC e alle direttive VDE pertinenti. Vanno inoltre osservate le condizioni di allacciamento dell'azienda locale di approvvigionamento di energia. E Prima dell'allacciamento elettrico o di ogni intervento interrompere assolutamente l'alimentazione di corrente. Per procedere all'allacciamento elettrico è necessario togliere il coperchio superiore dell'apparecchio. A tale scopo, allentare le quattro viti a esagono cavo sulla lamiera di copertura posteriore e sfilare il coperchio verso l'alto. Introdurre il cavo di alimentazione nel passacavo sul lato posteriore della termopompa. Tutti gli altri eventuali cavi di comando per flussostati, termostati antigelo e sonde termiche vengono anch'essi introdotti sul lato posteriore della termopompa. E Alimentazione di potenza al quadro di comando L'alimentazione di potenza della termopompa deve essere dotata di un interruttore principale o di un interruttore onnipolare con una distanza minima di apertura dei contatti di 3 mm e di un interruttore automatico tripolare con sgancio congiunto di tutti i conduttori esterni. Il valore della corrente di apertura è riportato nei dati tecnici o sulla targhetta di designazione sul retro della termopompa! I cavi di alimentazione devono avere una sezione adeguata per la potenza dell'apparecchio in conformità alle norme vigenti. 18 Allacciamento elettrico Struttura apparecchio, assegnazione morsetti HP GEO ..T.MT(T.HT1) HP GEO 05T.MT - 17T.HT1 Utenze Sorgente Componenti cablati in fabbrica Descrizione Morsetto RVS61 Uscita RVS61 N9 Bassa pressione K E9 N10 Alta pressione K E10 N26 Pressostato sorgente P EX7 Q8 Pompa sorgente U Q8 Q9 Pompa condensatore V Q9 R25 Resistenza elettrica W QX1 B81 Sonda temperatura gas caldo 1 f B81 B21 Sonda temperatura di mandata termopompa n B21 B71 Sonda temperatura di ritorno termopompa q B71 B91 Sonda temperatura entrata sorgente r B91 B92 Sonda temperatura uscita sorgente s B92 N2 Unità di comando X30 AVS37 N1 Regolatore per termopompa RVS 61.813/187 Altri componenti importanti da cablare nell'impianto Descrizione Morsetto RVS61 Uscita RVS61 N15 Flussostato sorgente (solo per termopompe acqua-acqua) P EX4 B9 Sonda temperatura esterna k B9 Per una visione d'insieme delle possibilità di assegnazione dei morsetti e dei collegamenti elettrici, osservare lo schema elettrico della termopompa! 19 Allacciamento elettrico Struttura apparecchio, assegnazione morsetti HP GEO R..T.MT(T.HT1) HP GEO R 05/05T.MT - 17/16T.HT1 Utenze Sorgente Componenti cablati in fabbrica Descrizione Morsetto RVS61 Uscita RVS61 N9 Bassa pressione K E9 N10 Alta pressione K E10 N24 Flussostato consumatori P EX3 N26 Pressostato sorgente P EX7 Q9 Pompa condensatore V Q9 R25 Resistenza elettrica W QX1 Y22 Valvola inversione processo Y22 W QX2 Q8 Pompa sorgente a regime variabile Y QX4 B81 Sonda temperatura gas caldo 1 f B81 B21 Sonda temperatura di mandata termopompa n B21 B71 Sonda temperatura di ritorno termopompa q B71 B91 Sonda temperatura entrata sorgente r B91 B92 Sonda temperatura uscita sorgente s B92 B83 Sonda refrigerante liquido B83 w BX5 N2 Unità di comando X30 AVS37 N1 Regolatore per termopompa RVS 61.813/187 Altri componenti importanti da cablare nell'impianto Descrizione Morsetto RVS61 Uscita RVS61 N15 Flussostato sorgente (solo per termopompe acqua-acqua) P EX4 B9 Sonda temperatura esterna k B9 Per una visione d'insieme delle possibilità di assegnazione dei morsetti e dei collegamenti elettrici, osservare lo schema elettrico della termopompa! 20 Allacciamento elettrico Struttura apparecchio, assegnazione morsetti HP GEO ..T.HT1 HP GEO 22T.HT1 - 43T.HT1 Utenze Sorgente Quelle Componenti cablati in fabbrica Descrizione Morsetto RVS61 Uscita RVS61 N9 Bassa pressione K E9 N10 Alta pressione K E10 N26 Pressostato sorgente P EX7 B81 Sonda temperatura gas caldo 1 f B81 B21 Sonda temperatura di mandata termopompa n B21 B71 Sonda temperatura di ritorno termopompa q B71 B91 Sonda temperatura entrata sorgente r B91 B92 Sonda temperatura uscita sorgente s B92 N2 Unità di comando X30 AVS37 N1 Regolatore per termopompa N11 Sovraccarico compressore RVS 61.813/187 Q E11 Morsetto RVS61 Uscita RVS61 Altri componenti importanti da cablare nell'impianto Descrizione N15 Flussostato sorgente (solo per termopompe acqua-acqua) P EX4 Q8 Pompa sorgente U Q8 Q9 Pompa condensatore V Q9 B9 Sonda temperatura esterna k B9 Per una visione d'insieme delle possibilità di assegnazione dei morsetti e dei collegamenti elettrici, osservare lo schema elettrico della termopompa! 21 Allacciamento elettrico Struttura apparecchio, assegnazione morsetti HP GEO R ../..T.HT1 HP GEO R 22/21T.HT1 - 43/45T.HT1 Sorgente Quelle Utenze Componenti cablati in fabbrica Descrizione Morsetto RVS61 Uscita RVS61 N9 Bassa pressione K E9 N10 Alta pressione K E10 P EX3 N24 Flussostato consumatori N26 Pressostato sorgente P EX7 Y22 Valvola inversione processo Y22 W QX2 B81 Sonda temperatura gas caldo 1 f B81 B21 Sonda temperatura di mandata termopompa n B21 B71 Sonda temperatura di ritorno termopompa q B71 B91 Sonda temperatura entrata sorgente r B91 B92 Sonda temperatura uscita sorgente s B92 B83 Sonda refrigerante liquido B83 w BX5 N2 Unità di comando X30 AVS37 N1 Regolatore per termopompa N11 Sovraccarico compressore RVS 61.813/187 Q E11 Morsetto RVS61 Uscita RVS61 Altri componenti importanti da cablare nell'impianto Descrizione N15 Flussostato sorgente (solo per termopompe acqua-acqua) P EX4 Q8 Pompa sorgente u UX Q9 Pompa condensatore V Q9 B9 Sonda temperatura esterna k B9 Per una visione d'insieme delle possibilità di assegnazione dei morsetti e dei collegamenti elettrici, osservare lo schema elettrico della termopompa! 22 IMPORTANTE per pompa sorgente HP GEO R ../..T.HT1: Per il corretto funzionamento del regime raffreddamento, le pompe reversibili necessitano di pompe sorgente a regime variabile in grado di gestire la condensazione nel compressore. Le pompe sono comandate dal regolatore tramite un segnale 0-10 V o un segnale PWM (modulazione di larghezza di impulso). Allacciamento elettrico Scatola elettrica HP GEO ..T.MT(T.HT1) 1 3 2 4 5 6 7 8 Legenda 1 2 3 4 Regolatore per termopompa RVS 61 Allacciamento a rete: fase AC 230 V, conduttore di terra, conduttore neutro Alimentazione principale 3x400V Fusibile comando 5 6 7 8 Contattore resistenza elettrica Morsettiera consumatori (blocco AE / flussostato sorgente, sicurezza termica Q8) Avviatore progressivo e relè corrente trifase Cavo di collegamento per unità di comando (MHI) AVS37 23 Allacciamento elettrico Scatola elettrica HP GEO ..M.MT 1 2 3 4 5 6 7 8 9 Legenda 1 2 3 4 24 Regolatore per termopompa RVS 61 Allacciamento a rete: fase AC 230 V, conduttore di terra, conduttore neutro Alimentazione principale 3x400V Fusibile comando 5 6 7 8 Fusibile compressore Contattore resistenza elettrica Fusibile resistenza elettrica Morsettiera consumatori (blocco AE / flussostato sorgente, sicurezza termica Q8) 9 Cavo di collegamento per unità di comando(MHI) AVS37 10 Avviatore progressivo e relè corrente trifase 10 Allacciamento elettrico Scatola elettrica HP GEO ..T.HT1(HP GEO R) 1 2 3 7 4 5 6 Legenda 1 2 3 Regolatore per termopompa RVS 61 Allacciamento a rete: fase AC 230 V, conduttore di terra, conduttore neutro Alimentazione principale 3x400V 4 5 6 7 Morsettiera consumatori (blocco AE / flussostato sorgente, sicurezza termica Q8) Avviatore progressivo e relè corrente trifase Cavo di collegamento per unità di comando(MHI) AVS37 Fusibile comando 25 Riempimento di impianti a sonde geotermiche Problematica Concentrazione sbagliata di glicole Lavaggio Problematica Il riempimento di impianti a sonde geotermiche con antigelo può essere all'origine di vari problemi che riducono le prestazioni dell'impianto o provocano addirittura un guasto totale. Le difficoltà principali sono le seguenti: Impurità nel circuito Le ditte di trivellazione s'impegnano in generale a riempire le sonde solo con acqua pulita. Dall'inserimento delle sonde fino al loro allacciamento, lo sporco e la sabbia possono comunque penetrare nelle sonde in seguito a disattenzione. Queste impurità possono danneggiare la pompa di circolazione o l'evaporatore della termopompa. Lavaggio Con acqua corrente filtrata si procede dapprima al lavaggio a pressione della pompa di circolazione del circuito delle sonde e dell'evaporatore per eliminare le impurità, come goccioline di condensa, sassolini e sporcizia. Dopo aver chiuso una valvola a cassetto nel circuito della termopompa si risciacquano in successione i singoli circuiti delle sonde geotermiche. Una sonda con diametro 32 mm lunga 140 metri deve essere risciacquata a una pressione di 2 bar per almeno 6 minuti, come indicato nel diagramma sottostante. Corretto riempimento del circuito delle sonde geotermiche mediante impianto di miscelazione con tanica e filtro Tutti i problemi elencati in precedenza possono essere evitati con il corretto riempimento del circuito delle sonde geotermiche. A tale scopo basta disporre dell'equipaggiamento adeguato. Con una tanica di miscelazione e di riempimento è possibile riempire il circuito delle sonde geotermiche in conformità ai seguenti requisiti: miscela pulita; concentrazione corretta; miscelazione omogenea. Durata minima di lavaggio per sonde di 32 mm Acqua glicolata mal miscelata Se la corretta quantità calcolata di antigelo viene aggiunta in forma concentrata senza un dispositivo di miscelazione adeguato, la viscosità del concentrato può disconnettere singole sonde. Nelle sonde restanti circola acqua senza il tenore di glicole richiesto che può dunque gelare già al momento della messa in servizio della termopompa e distruggerne l'evaporatore. 10 9 Durata in minuti 8 7 6 5 4 3 2 Concentrazione sbagliata di glicole In alcuni casi è stata riscontrata una concentrazione di glicole molto diversa da quella calcolata. La causa era generalmente la mancanza di un dispositivo per preparare correttamente la miscela. Con una concentrazione troppo elevata di glicole, le prestazioni della termopompa si riducono e il rendimento diminuisce. Inoltre, la pompa di circolazione può surriscaldarsi. Una concentrazione troppo bassa (< 20%) può invece essere all'origine di danni causati dalla corrosione o dal gelo. 1 0 0 50 100 Lunghezza delle sonde Pressione 2 bar Pressione 3 bar Tubo flessibile di riempimento Termopompa Valvola di sicurezza 2,5 bar Filtro Tanica 120 l Sonde geotermiche Pompa jet, p.e. Grundfos max. 5 m3/h max. 5 bar Pompa di circolazione acqua glicolata Vaso di espansione circuito sonde geotermiche Tubo di scarico 26 150 200 Riempimento di impianti a sonde geotermiche Riempimento con antigelo Corretto riempimento di un circuito sonda geotermica Riempimento con antigelo Dopo il lavaggio, l'intero circuito della sonda geotermica è riempito con acqua corrente pulita. Per ottenere in modo semplice la concentrazione richiesta di antigelo a partire da un concentrato (100%), procedere come descritto qui di seguito. A titolo di esempio consideriamo una concentrazione richiesta di antigelo del 25% (fascia ideale 25-30%) e una sonda geotermica Duplex® ø 32 mm di 140 metri. (capienza per metro = 4 tubi x 10 dm di lunghezza x 0,13 dm di diametro interno2 x π = 2,12 l/m) Diametro sonda Capienza per metro 25 mm 1,31 l/m 32 mm 2,12 l/m 40 mm 3,34 l/m 6. Riempire la tanica di miscelazione con l'antigelo concentrato e acqua fresca nel rapporto di circa 1:1. A seconda della tanica non è possibile versare in una volta tutti gli 82 litri di concentrato (calcolati al punto 3). 12. Se in un impianto sono collegate più sonde geotermiche si procede in modo analogo a quello descritto in precedenza. La seconda, la terza, sonda geotermica vengono dapprima risciacquate e poi riempite singolarmente. 7. Inserire la pompa di riempimento. Non appena la tanica inizia a vuotarsi, versarvi man mano l'antigelo concentrato e acqua fresca aggiuntiva nel rapporto di circa 1:1. Nella tanica deve sempre rimanere una riserva di almeno 40 litri di miscela. Sull'esterno della tanica si possono segnare delle graduazioni di volume. 8. Lasciare inserita la pompa, finché tutta la quantità di antigelo (eccetto i 40 litri di miscela di riserva) sono defluiti, poi disinserirla immediatamente. Dal tubo di scarico, l'acqua corrente in eccesso fluisce nello scolo. 9. A questo punto introdurre il tubo di scarico nella tanica e inserire nuovamente la pompa; lasciarla inserita, finché il glicole e l'acqua risultano ben miscelati. Questa operazione richiede un tempo da circa 6 a 8 volte superiore a quello del lavaggio (vedi diagramma al punto «Lavaggio»). 13. Quando tutte le sonde sono riempite occorre ancora riempire l'evaporatore e la pompa di circolazione dell'acqua glicolata. A tale scopo, chiudere tutte le valvole a cassetto delle sonde e aprire valvole a cassetto dell'evaporatore. A questo punto la miscela restante viene pompata con cura attraverso la valvola a cassetto del tubo di riempimento. Dal tubo di scarico si lascia defluire l'acqua nel circuito. Non appena fuoriesce la miscela di glicole dal tubo di scarico (cambiamento di colore), chiudere il rubinetto del tubo di scarico e riempire il vaso di espansione tramite la pressione della pompa (2,5 bar). Da ultimo si chiude il rubinetto del tubo di riempimento. In questo modo, l'impianto è privo di impurità, riempito con la corretta concentrazione e portato alla pressione di esercizio richiesta. Corretto riempimento di un circuito sonda geotermica in 14 punti 1. Risciacquare il circuito della sonda geotermica come descritto a pagina 22. 2. Calcolare il volume della sonda in base alla precedente tabella. Una sonda geotermica ø 32 mm ha una capienza di 2,12 l/m. Nel nostro esempio si ottiene la seguente capienza: 140 m x 2,12 l/m = 296,8 litri (297 litri). Non va dimenticata la capienza delle condotte di collegamento alla termopompa, nel nostro caso 30 litri. La capienza totale dell'impianto è dunque di 297 litri + 30 litri = 327 litri. 3. Quantità necessaria di antigelo concentrato (100%): 25% di 327 litri = 82 litri. 4. Chiudere le valvole a cassetto della termopompa, estrarre il tubo di scarico dalla tanica e collocarlo in uno scolo. 5. Aprire le valvole a cassetto della sonda geotermica (in caso di più sonde, per il riempimento le valvole vengono aperte in successione). 10. Chiudere il rubinetto di riempimento del tubo di scarico e in seguito quello del distributore delle sonde geotermiche. La miscela eccedente rifluisce nella tanica attraverso la valvola di sicurezza (2.5 bar). Disinserire la pompa. Nella tanica rimangono ancora quasi 40 litri. Una parte è stata assorbita dall'espansione delle sonde. 11. In caso di sonde relativamente lunghe e pessima miscelazione, la valvola di sicurezza presso la tanica interviene e intensifica la miscelazione. 14. Procedere con la prova a pressione: la prova dovrebbe continuare per un lungo periodo per evitare successive e dispendiose ricerche delle perdite. Nota: gli impianti riempiti con miscele antigelo tendono ad avere problemi di tenuta molto prima degli impianti riempiti con acqua pura. L Riempire il circuito acqua glicolata con una pressione di 1 bar (pressione in entrata MAG) + 0,3 bar di riserva di espansione, dunque con 1,3 bar. L Durante l'esercizio, la differenza di temperatura tra ingresso e uscita acqua glicolata non dovrebbe essere superiore a 4 K. 27 Riempimento di impianti a sonde geotermiche Riempimento con antigelo Corretto riempimento di un circuito sonda geotermica Dispositivi necessari lato riscaldamento Lato riscaldamento vanno integrati i seguenti dispositivi: valvola di riempimento, manometro, valvola di sicurezza, vaso di espansione e pompe di circolazione. Nelle termopompe in esecuzione compatta (HP GEO ..T.MT) la pompa di circolazione è già integrata. Lavaggio, riempimento e disaerazione Anche il lato riscaldamento deve essere lavato e riempito. L'acqua di riempimento dell'impianto di riscaldamento deve essere trattata in base alle prescrizioni VDI 2035 vigenti. È essenziale disaerare completamente l'impianto di riscaldamento per non pregiudicare il corretto funzionamento della termopompa. Occorre perciò prevedere disaeratore; nelle termopompe compatte è già integrato nella mandata. In questo caso è necessario adattare la pressione in entrata nel vaso di espansione a membrana (riscaldamento, di fabbrica 1 bar) alle condizioni locali. (Altezza statica 1 m = 0,1bar). La pressione di riempimento a freddo dovrebbe avere il seguente valore: pressione in entrata MAG + 0,2 bar (riserva espansione) L Qualità dell'acqua di riscaldamento La composizione e la qualità dell'acqua in circolazione influiscono direttamente sulle prestazioni dell'intero sistema e sulla durata di esercizio della caldaia. Per il primo riempimento e il rabbocco dell'impianto si utilizza di norma acqua corrente con valore pH 7-8, premesso che non sia troppo corrosiva (tenore di cloruro > 150 mg/l) o troppo dura (>14° dH; classe di durezza IV). Un'analisi dell'acqua potabile può essere richiesta presso l'azienda dell'acqua competente. Se il volume dell'impianto specifico è superiore a 25 litri per kW di potenza termica (p.e. con l'inserimento di un accumulatore tampone per l'acqua di riscaldamento), l'apporto massimo ammissibile di calcio attraverso l'acqua di riempimento e di rabbocco deve essere determinato in base ai calcoli della direttiva VDI 2035. Se del caso è necessario procedere a un addolcimento dell'acqua di riempimento. Non si possono utilizzare additivi chimici anticorrosione. Qualità dell'acqua sconosciuta e sostituzione di impianti Nell'acqua di riscaldamento sono spesso presenti sostanze e additivi che possono pregiudicare il corretto funzionamento e la durata di vita della caldaia a condensazione. Pertanto: • prima di procedere alla sostituzione del vecchio impianto, scaldare l'intero sistema e vuotarlo oppure • risciacquare con la massima cura il sistema di riscaldamento; il risciacquo dell'impianto dovrebbe essere eseguito poco prima della messa in servizio della caldaia. Per l'Austria vale inoltre: ÖNORM H 5195-1. Per la Svizzera vale inoltre: SITC n. 97-1. Criterio Valore ammissibile Effetti in caso di inosservanza Il riempimento deve essere eseguito conformemente a DIN EN 1717. Valore pH 7-8 Rischio di corrosione per componenti della caldaia e impianto di riscaldamento L Durezza dell'acqua < 14 dH - Tenore di cloruro < 150 mg/l Corrosione di materiali legati Attenzione! Osservare la qualità dell'acqua, VDI 2035 28 Maggiore deposito di calcare Minore durata di esercizio della caldaia Eliminazione guasti Eliminazione guasti HP GEO Anomalia Causa 106: T sorgente troppo bassa TP acqua glicolata-acqua Temperature di uscita acqua glicolata troppo basse (Parametro 2816, -8 °C) A1 Flusso volumetrico basso A2 A3 A4 A5 A6 Sonda mal riempita Bilanciamento sonda non OK Valvola a cassetto chiusa Pompa non funziona Sonda sovradimensionata A7 Sovraccarico sonda 106: T sorgente troppo bassa TP acqua-acqua Inserimento della protezione antigelo quando la termopompa è in funzione e la temperatura di entrata sorgente è inferiore a 3°C. A Sonda difettosa B Flusso volumetrico falda insufficiente C 107: Gas caldo compressore Scambiatore di separazione sistemi sporco o dimensionato in modo errato Temperatura gas caldo (B81) troppo alta A Quantità insufficiente di refrigerante B Compressore non ermetico C Filtro deidratore sporco D Impostazione troppo alta temperatura di sistema 146: Configurazione sonda/ organo di regolazione A Sonde collegate non conformi alla funzione impostata gli ingressi e alle uscite programmabili. 222: Alta press. in regime TP Azione sul contatto E10 del RVS 61. Errore alta pressione in regime TP. Il pressostato di massima nel circuito raffreddamento si è inserito. Il calore non può essere ceduto. A In regime riscaldamento A1 Portata insufficiente A1 Controllare potenza pompa acqua glicolata (ΔT=3-4K) A2 Disaerare la sonda A3 Regolatore di flusso A4 Aprire la valvola a cassetto A5 Controllare relè termico, fasi e relè A6 Controllare le ore di funzionamento del compressore dalla messa in servizio; non superiori a 1800 ore all'anno (dimensionamento errato o sovraccarico, notifica) A1 B1 B2 B4 Verificare il funzionamento della sonda B92 Controllare l'insudiciamento dei filtri Controllare l'insudiciamento dell'evaporatore Quantità di acqua da pozzo o circuito acqua glicolata insufficiente; controllare la differenza di temperatura tra entrata e uscita sorgente durante l'esercizio (ΔT=3-4K) B5 Controllare la differenza di temperatura tra circuito secondario e primario (ΔT=ca 2-3K); ev. pulire, controllare le impostazioni della pompa. C Controllare il funzionamento del circuito intermedio (se presente), controllare l'insudiciamento dello scambiatore a piastre A B C Controllare la quantità di refrigerante Sostituire il compressore Controllare la differenza di temperatura tra ingresso e uscita filtro deidratore (ΔTmax = 3) In questi casi è necessario chiamare il tecnico del freddo D Controllare impostazione temperatura di sistema. La curva di riscaldamento e la temperatura ACS devono essere entro i limiti d'impiego della termopompa! A Controllare la configurazione delle sonde A1 Verificare la funzione programmata alle uscite Qx A2 Verificare la configurazione dell'impianto tramite i numeri di controllo In caso di anomalia o errore, il modulo porta l'unità corrispondente in uno stato di sicurezza. A1 Controllare la portata dell'acqua di riscaldamento (ΔT =5-10 K) A2 Aprire la valvola a cassetto. Controllare le valvole di ritegno e le valvole a 3 vie. A3 Controllare il funzionamento della pompa. rimetterla in funzione, ev. sostituirla. A4 Integrare una valvola di sovrapressione, ripetere la procedura di regolazione. A5 Abbassare la curva di riscaldamento B Se A può essere escluso, eventuale eccessiva quantità di refrigerante. In questo caso è necessario chiamare il tecnico del freddo Azione sul contatto E10 del RVS 61. Errore alta pressione all'avvio della TP. A Acqua troppo fredda nel sistema (< 10°C). A A2 Valvola a cassetto chiusa, valvole di ritegno non si chiudono A3 Pompa di circolazione riscaldamento o ACS non funziona A4 Valvola di sovrapressione mancante o impostata scorrettamente A5 Curva riscaldamento troppo alta 223: Alta pressione in avvio CR Eliminazione, provvedimenti Inferiore a 10 °C: aumentare la temperatura nel sistema tramite la resistenza elettrica. 29 Eliminazione guasti Eliminazione guasti HP GEO Anomalia Causa Eliminazione, provvedimenti 224: Alta pressione in avvio ACS Azione sul contatto E10 del RVS 61, Errore alta pressione all'avvio regime ACS. 225: Anomalia bassa pressione A Pompa di carico ACS non funziona A B Valvola a 3 vie non si apre abbastanza in fretta o del tutto B C Quantità di acqua insufficiente C D E Aria nell'impianto Valvola a cassetto chiusa D E F Superficie di scambio termico nell'accumulatore insufficiente F G Sonda posizionata male/troppo bassa nell'accumulatore G Sbloccare o sostituire la pompa di carico accumulatore Controllare la valvola a 3 vie, ev. sostituire. Ev. prolungare l'anticipo della pompa condensatore (parametro 2802) Controllare la differenza di temperatura tra mandata e ritorno (ΔT=circa 5-8 K) Disaerare l'impianto Aprire la valvola a cassetto, controllare l'elemento mobile Superficie di scambio richiesta (in m2) = potenza termica TP (aria 20 °C/acqua 50 °C) x 0,3. Es. 10 kW x 0,3 = 3 m2. Potenza TP alla temperatura sorgente: vedi dati tecnici. Montare correttamente la sonda. Controllare posizione sonda ACS. Bassa pressione compressore Azione sul contatto E9 del RVS 61. Energia della sorgente insufficiente! Il pressostato di minima nel circuito raffreddamento si è inserito. 226: Compressore 1 sovracc. 228: Flussostato sorgente 30 A Portata insufficiente dell'acqua glicolata/ acqua nell'evaporatore B Perdita nel circuito di raffreddamento C Pressostato difettoso D Filtro ostruito E Valvola d'iniezione difettosa od ostruita F Quantità di refrigerante sbagliata Azione sul contatto E11 del RVS 61. Il limitatore di sovraccarico si è inserito. Solo in HP GEO 28T.HT1-43T.HT1. A Surriscaldamento compressore A1 Quantità insufficiente di refrigerante A2 Interruzione di fase A A1 Pompa acqua glicolata bloccata; rimettere in funzione la pompa A11 Scongelare l'acqua glicolata nell'evaporatore (togliere l'isolamento, scongelare con un asciugacapelli o attendere 1 giorno) A2 In caso di miscela non omogenea, il glicole può in parte bloccarsi nell'evaporatore A21 Miscelare meglio l'acqua glicolata B Se tutti i punti di cui sopra sono stati controllati e se l'evaporatore segnala un'anomalia di bassa pressione subito dopo l'inserimento, c'è una perdita nel circuito di raffreddamento. Tracce di olio nell'apparecchio indicano una perdita nel circuito di raffreddamento (non confondere l'olio con l'acqua glicolata). B1 In caso di perdita nel circuito di raffreddamento è necessario chiamare il tecnico del freddo. C Controllare il punto di commutazione (attenzione: dipende dal tipo di refrigerante) D Misurare la temperatura prima e dopo il filtro (ΔT max = 3 K). E Regolare o sostituire la valvola d'iniezione (in questo caso è necessario chiamare il tecnico del freddo). Controllare e isolare la sonda. F Controllare la quantità di refrigerante. In questo caso è necessario chiamare il tecnico del freddo A1 Controllare la quantità di refrigerante. A2 Controllare tutte e tre le fasi (attendere finché l'interruttore termico si è raffreddato; può durare alcune ore) Azione sul contatto E15 (EX4) del RVS 61. A Valvole di intercettazione chiuse B Flussostato impostato scorrettamente A B C Pompa di falda difettosa C D E Filtro ostruito nella condotta acqua di falda Circuito intermedio ostruito D E Aprire le valvole di intercettazione Controllare il flussostato (verificare il punto di commutazione con la pompa acqua di falda in funzione aprendo/chiudendo lentamente l'elemento mobile) Verificare il funzionamento della pompa acqua di falda Pulire il filtro nella condotta acqua di falda Pulire lo scambiatore del circuito intermedio Eliminazione guasti Eliminazione guasti HP GEO Anomalia Causa 229: Pressostato sorgente fredda Il pressostato non si inserisce. Azione sul contatto E15 del RVS 61. A TP acqua glicolata-acqua: pressione dell'acqua glicolata troppo bassa In caso di anomalia o errore, il modulo porta l'unità corrispondente in uno stato di sicurezza. 230: Pompa sorgente sovracc. Il contatto termico della pompa sorgente si inserisce. Azione sul contatto E14 (EX2) del RVS 61. A Guasto alla pompa A1 Pompa bloccata A2 Il salvamotore si è inserito A3 Pompa difettosa Eliminazione, provvedimenti A1 Controllare la pressione dell'acqua glicolata con manometro (Pmin = 1 bar). A2 Controllare il pressostato acqua glicolata A3 Rabboccare acqua glicolata (attenzione: utilizzare la miscela presente) A4 Controllare il vaso di espansione durante il rabbocco (se la pressione aumenta rapidamente quando si rabbocca acqua glicolata, il vaso di espansione non è in funzione) A5 Se il guasto si ripresenta più volte, controllare l'ermeticità del circuito acqua glicolata A6 Verificare il collegamento elettrico tra pressostato e regolatore A1 Sbloccare la pompa e stabilire la causa A2 Stabilire la causa di inserimento del salvamotore A3 Controllare l'assorbimento di corrente della pompa (ampère) A22 Controllare il valore soglia del salvamotore A23 Controllare il buono stato del salvamotore A3 In caso di pompa difettosa, sostituirla In caso di anomalia o errore, il modulo porta l'unità corrispondente in uno stato di sicurezza. 358: Avviatore progressivo Azione sul contatto E25 (EX5) del RVS 61. L'avviatore progressivo SMC3 genera una tensione al morsetto 98. Sovraccarico Surriscaldamento Inversione di fase (campo rotante errato) Perdita di fase Asimmetria di fase Cortocircuito Blocco manuale dell'SMC 3 Eseguire reset del quadro di comando HMI e verificare i seguenti punti: 1. Misurare la corrente assorbita, regolare la corrente di apertura sull'SMC 3 2. Controllare le posizioni degli interruttori DIP sull'avviatore progressivo SMC3 3. Verificare il collegamento elettrico 4. Accertarsi del campo rotante destrorso 5. Verificare le 3 fasi di ingresso 6. Misurare la tensione delle 3 fasi 7. Eliminare il cortocircuito 8. In caso di alleggerimento del carico, integrare un relè supplementare; vedi info scaricatore. 12: Temp. carico ACS TP troppo bassa Il regolatore memorizza la temperatura ACS alla quale è stato interrotto l'ultimo carico con termopompa, quando quest'ultima aveva raggiunto il limite di alta pressione, temperatura gas caldo, temperatura massima di spegnimento. Se il valore è inferiore all'impostazione "Temp. carico ACS TP min." (riga 7092), sul display appare il simbolo di manutenzione e nel livello informativo il seguente avviso di manutenzione: "T. di carico TP insuff." Questo parametro non può essere annullato. Se al prossimo carico ACS viene nuovamente superata la temperatura minima si annulla anche l'avviso di manutenzione. Se invece la temperatura minima non viene raggiunta, l'avviso rimane. 1. Verificare la posizione della sonda B3. 2. Setpoint temp. ACS troppo alto. 3. Tipo di carico con B3 e B31 attivato; modificare con solo B3. 4. Pessima trasmissione termica sulla sonda ACS; migliorare con molla di fissaggio. 5. In caso di accumulatori combinati il carico ACS con valvola a 3 vie dovrebbe avvenire a diverse altezze. 6. Superficie di scambio termico nell'accumulatore insufficiente. Termopompa bloccata Informazione tramite parametro 8006 Stato TP 1. Blocco, T. esterna 2. Bloccata, esternamente Blocco esterno dell'azienda elettrica (AE) Caduta di tensione all'ingresso E6. 3. Blocco, modo eco 1. 2. 3. Temperatura esterna troppo bassa Blocco AE Nessuna anomalia, la termopompa si riavvia al termine del blocco. Verificare il funzionamento del relè di monitoraggio fase: al di fuori degli orari di blocco AE il LED verde del relè deve essere acceso. Regime estivo 31 Verbale di messa in servizio Lista di controllo HP GEO Impianto: Data: Attività OK Termopompa Definire lo schema idraulico, selezionarlo e confrontarlo con l'impianto: Verificare i componenti idraulici Valvola di sovrapressione integrata (50% sovrapressione), secondo schema impianto (non necessaria per impianti con accumulatore tampone e termopompe compatte) Controllare ed ev. adattare lato utenze (riscaldamento) la pressione in entrata nel vaso di espansione, la pressione dell'acqua e la valvola di sicurezza Disaerare l'impianto Valvole di arresto e di sicurezza aperte? Verificare la dimensione dei tubi Accumulatore ACS: Capienza accumulatore:___ litri Superficie di scambio termico:____ m2 (>= 0.3 m2/kW) Accumulatore tampone: Raccordi eseguiti correttamente? Capienza accumulatore:____ litri (30 l/kW con accumulatore di separazione) Verificare i collegamenti elettrici (confrontare lo schema elettrico con l'impianto): Controllare i passacavi Morsetti: controllare i collegamenti (viti serrate?) Controllare l'avviatore progressivo (ampère e commutatore DIP impostati correttamente?) Verificare il campo rotante e il conduttore di terra Fusibili di potenza adeguata Protezione forza con interruttore automatico onnipolare presente? Fusibile resistenza elettrica esterna? In caso di blocco AE, disinserimento tramite Logon B WP61 morsetto X1 / L e 1 tramite contattore (non soltanto tramite 3 fasi) Verificare la sede e la posizione corretta di tutte le sonde (vedi schema elettrico) Messa in servizio Regolazione RVS 61: Configurare il regolatore in funzione dello schema Memorizzare i parametri delle sonde! (Parametro 6200 "Configurazione") Verificare i valori delle sonde tramite test delle entrate/uscite (da riga 7700) Eseguire il test dei relè tramite test delle entrate/uscite. Attenzione: impedire l'inserimento del compressore! Dopo la prova impostare nuovamente il parametro su "Nessun test". Avviare la termopompa (ev. modificare il parametri 7150 Simulazione temperatura esterna nel menu "Manutenzione/Servizio". Attenzione: ripristinarlo dopo MiS! Compilare il verbale di messa in servizio. Sorgente termica Sonda geotermica: Aprire tutte le valvole sul collettore di distribuzione acqua glicolata Verificare la pompa acqua glicolata Q8 (senso di rotazione, direzione di flusso, ermeticità) Attenzione: nessuna pompa elettronica lato evaporatore Attenzione: per le termopompe reversibili HP GEO R è necessaria una pompa sorgente elettronica! 32 Osservazione Verbale di messa in servizio Lista di controllo HP GEO Attività OK - - Verificare l'acqua glicolata (-14 °C, 25%) tramite il test relè pompa acqua glicolata per 5 minuti; poi verificare ancora l'acqua glicolata: la misurazione deve rimanere costante. (La miscela glicole-acqua deve essere garantita!) Dispositivo di rabbocco presente (non tramite raccordo a termopompa) Dispositivo di sicurezza presente? Pressione riempimento circuito acqua glicolata 1 bar (pressione in entrata vaso espansione) + 0,3 bar di riserva di espansione, dunque pressione di riempimento 1,3 bar. Garantire la disaerazione dell'acqua glicolata (in caso di pressione variabile al manometro è presente ancora aria nell'impianto!) Verificare l'ermeticità di tutti i raccordi Controllo dell'isolamento – assenza di acqua di condensa Garantire il bilanciamento idraulico delle sonde (Taco Setter o misurazione delta T) Attenzione: delta T lato acqua glicolata 3-4K! Verificare solo con apparecchio di misura! Non tramite RVS 61! Controlli specifici per impianti con acqua di falda Attenzione: circuito intermedio presente? (separazione di sistema tramite scambiatore) Verificare l'acqua glicolata nel circuito intermedio (-14 °C, 25%) tramite il test relè pompa acqua glicolata per 1 minuto; poi verificare ancora l'acqua glicolata: la misurazione deve rimanere costante. (La miscela glicole-acqua nel circuito intermedio deve essere garantita!) Sifone più alto dello scambiatore termico presente nel ritorno al pozzo? Filtro presente nella condotta di alimentazione tra posso e pompa? Verificare la quantità di acqua della pompa pozzo (tramite delta T) Flussostato (E15) nel ritorno prima del sifone presente e funzionante (deve essere impostato) Pozzo di captazione e di reimmissione distanti almeno 15 m Osservazione Cessione calore / Altre verifiche in esercizio - Controllare il vetro spia nel circuito frigorifero (fascia verde/a partire da circa 40° C mandata. assenza di bolle visibili) Verificare la rumorosità (ciclo compressore regolare) Verificare l'assenza di trasmissione di rumori per via strutturale (raccordi flessibili, sospensioni isolate dei tubi, trasmissione di vibrazioni al pavimento) Il delta T lato riscaldamento deve essere compreso tra 8 e 10 K! (regolare tramite regime pompa) Controlli di sicurezza - - - Testare lo spegnimento di sicurezza per alta pressione: a tale scopo chiudere il flusso lato riscaldamento. (Errore 222 Spegnimento alta pressione) Testare lo spegnimento di sicurezza per bassa pressione: a tale scopo chiudere il flusso lato sorgente. (Errore 225 Spegnimento bassa pressione) Testare lo sbrinamento fino alla fine (sbrinamento manuale: premere il tasto Reset per 5 sec.) Verificare il funzionamento del pressostato acqua glicolata. Con la termopompa in funzione, inserire un ponticello sul morsetto EX7 del RVS 61. Attenzione: Dopo 4 secondi appare un avviso "Tempo di limitazione attivo". Lasciare staccato il connettore EX7 e impostare il parametro 7160 (Manutenzione/Servizio) Ripristino su "sì". (Reset possibile anche tramite il tasto reset!). La termopompa si riavvia finché appare il messaggio di errore 229 Pressostato sorgente termica. Inserire di nuovo il connettore; reset errore, la termopompa si riavvia da sola. Regolare correttamente le valvola di sovrapressione Altre osservazioni: 33 Impianto Dati caratteristici sonde NTC 1 k Dati caratteristici sonde NTC 10 k Dati caratteristici sonde NTC 1 k per sonda temperatura esterna B9 T [°C] -30.0 R[Ohm] 13'034 T [°C] 0.0 R[Ohm] 2'857 T [°C] 30.0 R[Ohm] 827 -29.0 12'324 1.0 2'730 31.0 796 -28.0 11'657 2.0 2'610 32.0 767 -27.0 -26.0 11'031 10'442 3.0 4.0 2'496 2'387 33.0 34.0 740 713 -25.0 9'889 5.0 2'284 35.0 687 -24.0 -23.0 9'369 8'880 6.0 7.0 2'186 2'093 36.0 37.0 663 640 -22.0 8'420 8.0 2'004 38.0 617 -21.0 -20.0 7'986 7'578 9.0 10.0 1'920 1'840 39.0 40.0 595 575 -19.0 7'193 11.0 1'763 41.0 555 -18.0 6'831 12.0 1'690 42.0 536 -17.0 -16.0 6'489 6'166 13.0 14.0 1'621 1'555 43.0 44.0 517 500 -15.0 5'861 15.0 1'492 45.0 483 -14.0 -13.0 5'574 5'303 16.0 17.0 1'433 1'375 46.0 47.0 466 451 -12.0 5'046 18.0 1'320 48.0 436 -11.0 4'804 19.0 1'268 49.0 421 -10.0 -9.0 4'574 4'358 20.0 21.0 1'218 1'170 50.0 407 -8.0 4'152 22.0 1'125 -7.0 -6.0 3'958 3'774 23.0 24.0 1'081 1'040 -5.0 3'600 25.0 1'000 -4.0 3'435 26.0 962 -3.0 -2.0 3'279 3'131 27.0 28.0 926 892 -1.0 2'990 29.0 859 Dati caratteristici sonde NTC 10 k per sonde B1, B3, B4, B21, B41, B71, B81, B91 e B92 34 T [°C] R[Ohm] T [°C] R[Ohm] T [°C] R[Ohm] -30.0 175203 50.0 3605 130.0 298 -25.0 129289 55.0 2989 135.0 262 -20.0 96360 60.0 2490 140.0 232 -15.0 72502 65.0 2084 145.0 206 -10.0 55047 70.0 1753 150.0 183 -5.0 42158 75.0 1481 155.0 163 0.0 32555 80.0 1256 160.0 145 5.0 25339 85.0 1070 165.0 130 10.0 19873 90.0 915 170.0 117 15.0 15699 95.0 786 175.0 105 20.0 12488 100.0 677 180.0 95 25.0 10000 105.0 586 185.0 85 30.0 8059 110.0 508 190.0 77 35.0 6535 115.0 443 195.0 70 40.0 5330 120.0 387 200.0 64 45.0 4372 125.0 339 Dimensioni degli apparecchi HP GEO 05T.MT - 17T.HT1 Vista frontale (lato di comando) Disegno quotato Vista laterale sinistra Vista posteriore Pianta con distanze minime Accesso ai comandi HP GEO a b c d e g h i j k l m n P q r s t u v 05-14T.MT 580 580 1102 1130 34 801 1250 85 424 424 28±5 52 108 140 382 329 195 147 236 860 17T.HT1 580 700 1102 1130 34 921 1250 85 424 544 28±5 52 108 140 382 329 195 147 236 860 HP GEO ..T.MT 1 Acqua riscaldamento Uscita Filetto interno 1" 2 Acqua riscaldamento Ingresso Filetto interno 1" 3 Sorgente fredda Uscita Filetto interno 1" 4 Sorgente fredda Ingresso Filetto interno 1" 5 Alimentazione elettrica (passacavi) 6 Cavo per sonda 7 Regolazione 8 Piedini antivibrazioni in gomma PG 13,5 + PG 29 Diametro Altezza ø viti 70 mm 45 mm M10x23mm 35 Dimensioni degli apparecchi HP GEO 22T.HT1 - 43T.HT1 Disegno quotato Vista frontale (lato di comando) Vista laterale sinistra Vista posteriore HP GEO ..T.HT1 1 Acqua riscaldamento Uscita Filetto interno 1¼" 2 Acqua riscaldamento Ingresso Filetto interno 1¼" 3 Sorgente fredda Uscita Filetto interno 1½" 4 Sorgente fredda Ingresso Filetto interno 1½" 5 Alimentazione elettrica (passacavi) 6 Cavo per sonda 7 Regolazione 8 Piedini antivibrazioni in gomma 36 PG 13,5 + PG 29 Diametro Altezza ø viti 70 mm 45 mm M10x23mm Dati tecnici HP GEO 05T.MT - 08T.MT 05T.MT Termopompa HP GEO ..T.MT Tipo di costruzione 1) Potenza termica con B0 Potenza frigorifera con B0 2) Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua Potenza frigorifera con W10 Potenza el. assorbita con W10 W35 W50 W35 W50 W35 W50 Qh kW 5.4 5.0 6.5 6.1 8.2 7.7 Qo kW 4.2 3.3 5.0 4.0 6.3 5.0 Pel kW 1.2 1.8 1.5 2.1 1.9 2.7 COP (-) 4.5 2.8 4.3 2.7 4.4 2.8 Qh kW 7.1 6.7 8.7 8.1 11.0 10.2 Qo kW 5.9 4.9 7.2 6.0 9.1 7.5 Pel kW 1.2 1.8 1.5 2.1 1.9 2.7 COP (-) 5.9 3.8 5.8 3.7 5.9 3.8 1) Potenza termica con W10 2) Coefficiente di rendimento con W10 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 08T.MT Esecuzione compatta Dati normalizzati termopompe acqua glicolata Potenza el. assorbita con B0 06T.MT 3) DN 32 l 1 1 1.1 kg 1.3 1.6 1.75 m 93 111 2x70 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 1350 1600 2000 kPa 11 6 15 kPa 29 30 48 l/h 1850 2300 2900 kPa 22 12 31 kPa 9 13 26 l 2.3 3.1 3.1 % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico (∆t 7,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l/h 650 800 1000 kPa 2 5 6 kPa 48 43 40 l/h 850 1050 1350 kPa 5 6 9 kPa 43 40 33 l 2.3 2.6 2.6 % 100 Campo di impiego Sorgente termica: uscita acqua glicolata T min °C -8 -8 -8 Sorgente termica: uscita acqua T min °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento 37 Dati tecnici HP GEO 05T.MT - 08T.MT 05T.MT Termopompa HP GEO ..T.MT 06T.MT 08T.MT Dati elettrici 3 x 400 V / 50 Hz Tensione di esercizio, alimentazione kW 1.2 1.5 1.9 Fusibile esterno con resistenza elettrica AT 16 16 20 Fusibile esterno senza resistenza elettrica AT 10 10 13 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica l max. A 9 9 9 Corrente nominale compressore I max. A 4.2 5.1 6.3 Corrente con rotore bloccato LRA A 24 32 40 Corrente allo spunto con avviatore progressivo VSA A 10.5 12.8 15.8 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.13 0.13 0.25 max. (-) 3 3 3 Avviamenti ogni ora 6/4/2 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 110 115 115 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 41 41 41 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 38 580x580x1130 Off 0,65 / On 0,80 Secondo EN255 Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Dati tecnici HP GEO 10T.MT - 14T.MT 10T.MT Termopompa HP GEO ..T.MT Tipo di costruzione Potenza termica con B0 Potenza frigorifera con B0 2) Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua Potenza frigorifera con W10 Potenza el. assorbita con W10 1) W35 W50 W35 W50 W35 W50 Qh kW 9.6 9.0 12.0 11.3 14.4 13.5 Qo kW 7.4 5.9 9.2 7.6 11.1 9.0 Pel kW 2.2 3.1 2.8 3.8 3.3 4.5 COP (-) 4.5 2.9 4.3 3.0 4.3 3.0 Qh kW 12.9 12.0 15.9 14.7 19.1 17.5 Qo kW 10.8 8.9 13.3 11.0 15.6 12.7 Pel kW 2.2 3.1 2.6 3.7 3.5 4.8 COP (-) 6.0 3.8 6.0 4.0 5.5 3.7 1) Potenza termica con W10 2) Coefficiente di rendimento con W10 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 14T.MT Esecuzione compatta Dati normalizzati termopompe acqua glicolata Potenza el. assorbita con B0 12T.MT 3) DN 32 l 1.1 1.36 1.42 kg 1.9 2.1 2.8 m 2x82 2x102 3x82 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 2350 2950 3500 kPa 10 15 14 kPa 50 73 72 l/h 3450 4250 4950 kPa 21 31 28 kPa 32 53 51 l 3.6 3.6 4.1 % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico (∆t 7,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l/h 1200 1500 1750 kPa 6 9 10 kPa 38 31 27 l/h 1600 1950 2350 kPa 8 10 5 kPa 31 24 25 l 3.1 3.6 3.6 % 100 Campo di impiego Sorgente termica: uscita acqua glicolata T min °C -8 -8 -8 Sorgente termica: uscita acqua T min °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento 39 Dati tecnici HP GEO 10T.MT - 14T.MT 10T.MT Termopompa HP GEO ..T.MT 12T.MT 14T.MT Dati elettrici 3 x 400 V / 50 Hz Tensione di esercizio, alimentazione kW 2.2 2.8 3.3 Fusibile esterno con resistenza elettrica AT 20 20 25 Fusibile esterno senza resistenza elettrica AT 13 16 20 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica l max. A 9 9 9 Corrente nominale compressore I max. A 7 10 11 Corrente con rotore bloccato LRA A 46 50 66 Corrente allo spunto con avviatore progressivo VSA A 17.5 25 27.5 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.25 0.46 0.46 max. (-) 3 3 3 Avviamenti ogni ora 6/4/2 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 120 125 135 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 43 43 43 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 40 580x580x1130 Off 0,65 / On 0,80 Secondo EN255 Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Dati tecnici HP GEO 07T.HT2 - 11T.HT2 Termopompa HP GEO ..T.HT2 07T.HT2 Tipo di costruzione Esecuzione compatta alta temperatura Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 secondo EN 14511 Dati normalizzati termopompe acqua Potenza frigorifera con W10 Potenza el. assorbita con W10 W35 W50 W35 W50 Qh kW 7 6.6 10.2 9.3 Qo kW 5.4 4.2 7.9 6.3 Pel kW 1.6 2.4 2.3 3.3 COP (-) 4.2 2.8 4.4 2.9 Qh kW 9.8 9.2 14.3 13.2 Qo kW 8.0 6.4 11.8 9.7 Pel kW 1.8 2.6 2.5 3.5 COP (-) 5.5 3.5 5.7 3.8 1) Potenza termica con W10 2) Coefficiente di rendimento con W10 secondo EN 14511 Refrigerante R 134a Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 11T.HT2* 3) DN 32 l 1.4 1.7 kg 2.0 2.6 m 2x60 2x88 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 1700 2500 kPa 10 20 kPa 42 39 l/h 2500 3750 kPa 20 30 kPa 18 20 l 3.6 4.1 % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico nom. (∆t 5,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 6) 7) 4) Flusso volumetrico nom. (∆t 5,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 6) 7) 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l/h 1200 1750 kPa 9 7 kPa 35 50 l/h 1700 2450 kPa 12 21 kPa 26 26 l 3.1 3.6 % 100 Campo di impiego Sorgente termica: uscita acqua glicolata T min °C -8 -8 Sorgente termica: uscita acqua T min °C 3 3 min/max °C 20/65 20/65 Temperatura mandata riscaldamento 41 Dati tecnici HP GEO 07T.HT2 - 11T.HT2 Termopompa HP GEO ..T.HT2 07T.HT2 11T.HT2* Dati elettrici 3 x 400 V / 50 Hz Tensione di esercizio, alimentazione kW 1.6 2.3 Fusibile esterno con resistenza elettrica AT 20 25 Fusibile esterno senza resistenza elettrica AT 16 20 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica l max. A 9 9 Corrente nominale compressore I max. A 10 13 Corrente con rotore bloccato LRA A 50 74 Corrente allo spunto con avviatore progressivo VSA A 25 32.5 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.22 0.32 max. (-) 3 3 Avviamenti ogni ora 6/4/2 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 115 125 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" Lwa dB(A) 45 49 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 Punto di commutazione pressostato acqua glicolata p bar Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 6) 7) 42 580x580x1130 Off 0,65 / On 0,80 Secondo EN 14511 (* misurato presso il Centro di collaudo termopompe WPZ) Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) Con flusso volumetrico nominale Dati tecnici HP GEO 17T.HT1 Termopompa HP GEO ..T.HT1 17T.HT1* Esecuzione compatta Tipo di costruzione Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua Potenza frigorifera con W10 2) Coefficiente di rendimento con W10 Qh kW 17.7 16.6 Qo kW 13.7 10.5 Pel kW 4.0 6.1 COP (-) 4.5 2.7 Qh kW 22.9 21.1 Qo kW 18.9 14.9 Pel kW 4.0 6.2 COP (-) 5.7 3.4 R 407 c Refrigerante Olio estere Olio circuito frigorifero Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda W50 1) Potenza termica con W10 Potenza el. assorbita con W10 W35 3) DN 32 l 1.57 kg 3.3 m 3x102 Evaporatore, lato acqua glicolata Scambiatore a piastre Inox AISI 316L, brasato Esecuzione l/h 4350 Perdita di carico con B0/W35 incl. tubi flessibili kPa 13 Pressione residua con B0/W35 4) kPa 70 l/h 6000 kPa 55 kPa 17 l 5.3 % 70/30 Flusso volumetrico (∆t 3,0 K con B0/W35) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) Condensatore, lato riscaldamento Scambiatore a piastre Inox AISI 316L, brasato Esecuzione Flusso volumetrico (∆t 5,0 K con B0/W35) 6) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 7) 4) Flusso volumetrico nom. (∆t 5,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 6) 7) 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l/h 3050 kPa 7 kPa 29 l/h 3950 kPa 8 kPa 9 l 6.2 % 100 Campo di impiego Sorgente termica: uscita acqua glicolata T min °C -8 Sorgente termica: uscita acqua T min °C 3 min/max °C 20/60 Temperatura mandata riscaldamento 43 Dati tecnici HP GEO 17T.HT1 Termopompa HP GEO ..T.HT1 17T.HT1* Dati elettrici 3 x 400 V / 50 Hz Tensione di esercizio, alimentazione kW 4.0 Fusibile esterno con resistenza elettrica AT 25 Fusibile esterno senza resistenza elettrica AT 20 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica l max. A 9 Corrente nominale compressore I max. A 15 Corrente con rotore bloccato LRA A 87 Corrente allo spunto con avviatore progressivo VSA A 37.5 Potenza assorbita resistenza elettrica Pmax. kW 6/4/2 Potenza assorbita pompe di circolazione Pmax. kW 0.48 max. (-) 3 sec. 60-120 kg 170 LxPxA mm 580x700x1130 Raccordo circuito riscaldamento FF pollici 1" Raccordo circuito acqua glicolata FF pollici 1" Lwa dB(A) 48 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 Punto di commutazione pressostato acqua glicolata p bar Off 0,65 / On 0,80 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente Dimensioni / Raccordi / Vari Peso Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 6) 7) *) 44 Secondo EN 14511 Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) Con flusso volumetrico nominale Dati misurati presso il Centro di collaudo termopompe (WPZ) di Buchs secondo EN 14511 Dati tecnici HP GEO 22T.HT1 - 43T.HT1 Termopompa HP GEO ..T.HT1 22T.HT1 Tipo di costruzione 28T.HT1* 35T.HT1 43T.HT1 Esecuzione normale alta temperatura Dati normalizzati termopompe acqua glicolata 1) W35 W60 W35 W60 W35 W60 W35 W60 Potenza termica con B0 Qh kW 21.0 20.4 28.7 24.8 36.7 34.7 44.4 41.3 Potenza frigorifera con B0 Qo kW 16.4 13.4 22.2 15.6 28.4 23.3 34.4 27.8 Potenza el. assorbita con B0 Pel kW 4.6 7.0 6.5 9.2 8.3 11.4 10.0 13.5 COP (-) 4.6 2.9 4.4 2.7 4.4 3.0 4.4 3.1 Potenza termica con W10 Qh kW 25.9 25.6 35.5 34.2 48.9 46.0 58.6 54.5 Potenza frigorifera con W10 Qo kW 21.2 18.3 28.5 24.5 39.7 33.4 47.3 39.2 Potenza el. assorbita con W10 Pel kW 4.7 7.3 7.0 9.7 9.2 12.6 11.3 15.3 COP (-) 5.5 3.9 5.1 3.5 5.3 3.7 5.2 3.6 Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua 1) Coefficiente di rendimento con W10 secondo EN 14511 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 2) DN 32 l 2.7 4 4.1 4.1 kg 4.1 5.7 6.2 7.4 m 4x92 5x99 6x106 7x109 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico nom. (∆t 3,0 K con B0/W35) l/h 5250 7100 9050 10950 Perdita di carico con B0/W35 incl. tubi flessibili kPa 9 11 14 19 l 6700 9000 12550 14950 11 17 22 25 10.8 14.2 16.5 18.8 Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) l 3) % 70/30 Condensatore, lato riscaldamento Esecuzione Flusso volumetrico (∆t 5,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili 7) Flusso volumetrico nom. (∆t 5,0 K con W10/W35) 6) Scambiatore a piastre Inox AISI 316L, brasato 6) l/h 3600 4950 6350 7650 kPa 3 5 5 6 l 4450 6150 8400 10100 4 7 9 6 7.3 9.6 10.7 13 Perdita di carico con W10/W35 incl. tubi flessibili 7) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l % 100 45 Dati tecnici HP GEO 22T.HT1 - 43T.HT1 Termopompa HP GEO ..T.HT1 22T.HT1 28T.HT1* 35T.HT1 43T.HT1 Campo di impiego Sorgente termica: uscita acqua glicolata T min. °C -8 -8 -8 -8 Sorgente termica: uscita acqua T min. °C 3 3 3 3 min/max °C 20/60 20/60 20/60 20/60 Temperatura mandata riscaldamento Dati elettrici 3 x 400 V / 50 Hz Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 PNT Fusibile esterno kW 4.6 6.5 8.3 10 AT 3 x 25 3 x 32 3 x 40 3 x 40 Corrente nominale I max A 21 21 25 32 Corrente con rotore bloccato LRA A 84 127 167 198 Corrente allo spunto con avviatore progressivo VSA A 52.5 52.5 62.5 80 Avviamenti ogni ora max - 3 3 3 3 330 360 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 245 315 LxPxA mm Raccordo circuito riscaldamento FF pollici 1¼ 1¼ 1¼ 1¼ Raccordo circuito acqua glicolata FF pollici 1½ 1½ 1½ 1½ Lwa dB(A) 57 59 59 62 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 46 670x950x1020 Off 0.65 / On 0.80 Secondo EN 14511 (* misurato presso il Centro di collaudo termopompe WPZ) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) Con flusso volumetrico nominale Dati tecnici HP GEO 05M.MT - 08M.MT Termopompa HP GEO ..M.MT 05M.MT 08M.MT Esecuzione compatta monofase Tipo di costruzione Dati normalizzati termopompe acqua glicolata Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 06M.MT 2) Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua W35 W50 W35 W50 W35 W50 Qh kW 5.4 5.0 6.5 6.1 8.2 7.7 Qo kW 4.2 3.3 5.0 4.0 6.3 5.0 Pel kW 1.2 1.8 1.5 2.1 1.9 2.7 COP (-) 4.5 2.8 4.3 2.7 4.4 2.8 Qh kW 7.1 6.7 8.7 8.1 11 10.2 Qo kW 5.9 4.9 7.2 6.0 9.1 7.5 Pel kW 1.2 1.8 1.5 2.1 1.9 2.7 COP (-) 5.9 3.8 5.8 3.7 5.9 3.8 1) Potenza termica con W10 Potenza frigorifera con W10 Potenza el. assorbita con W10 1) 2) Coefficiente di rendimento con W10 R 407 c Refrigerante Olio estere Olio circuito frigorifero Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1 1.1 1.1 kg 1.3 1.6 1.75 m 93 111 2x70 Evaporatore, lato acqua glicolata Scambiatore a piastre Inox AISI 316L, brasato Esecuzione Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 1350 1600 2000 kPa 11 6 15 kPa 29 30 48 l/h 1850 2300 2900 kPa 22 12 31 kPa 9 13 26 l 2.3 3.1 3.1 % 70/30 Condensatore, lato riscaldamento Scambiatore a piastre Inox AISI 316L, brasato Esecuzione Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico (∆t 7,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) l/h 650 800 1000 kPa 2 5 6 kPa 48 43 40 l/h 850 1050 1350 kPa 5 6 9 kPa 43 40 33 l 2.3 2.6 2.6 % 100 47 Dati tecnici HP GEO 05M.MT - 08M.MT Termopompa HP GEO ..M.MT 05M.MT 06M.MT 08M.MT Campo di impiego Sorgente termica: uscita acqua glicolata T min. °C -8 -8 -8 Sorgente termica: uscita acqua T min. °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici 1 x 230 V / 50 Hz Tensione di esercizio, alimentazione kW 1.2 1.5 1.9 Fusibile esterno con resistenza elettrica AT 32 32 32 Fusibile esterno senza resistenza elettrica AT 16 20 25 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica I max A 9 9 9 Corrente nominale compressore I max. A 11.4 14.8 17.3 Corrente con rotore bloccato LRA A 47 61 76 Corrente allo spunto con avviatore progressivo VSA A 45 45 45 Potenza assorbita resistenza elettrica max. kW Potenza assorbita pompe di circolazione max. kW 0.13 0.13 0.25 Avviamenti ogni ora max. (-) 3 3 3 6/4/2 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 110 115 115 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 41 41 41 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 48 580x580x1130 Off 0.65 / On 0.80 Secondo EN255 Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Dati tecnici HP GEO 10M.MT - 12M.MT Termopompa HP GEO ..M.MT 10M.MT Tipo di costruzione 12M.MT Esecuzione compatta monofase Dati normalizzati termopompe acqua glicolata 1) W35 W50 W35 W50 Qh kW 9.6 9.0 12.0 11.3 Qo kW 7.4 5.9 9.2 7.6 Pel kW 2.2 3.1 2.8 3.8 COP (-) 4.5 2.9 4.3 3.0 Potenza termica con W10 Qh kW 12.9 12.0 15.9 14.7 Potenza frigorifera con W10 Qo kW 10.8 8.9 13.3 11.0 Potenza el. assorbita con W10 2) Pel kW 2.2 3.1 2.6 3.7 COP (-) 6.0 3.8 6.0 4.0 Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 Dati normalizzati termopompe acqua 1) Coefficiente di rendimento con W10 R 407 c Refrigerante Olio estere Olio circuito frigorifero Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1.1 1.4 kg 1.9 2.1 m 2x82 2x102 Evaporatore, lato acqua glicolata Scambiatore a piastre Inox AISI 316L, brasato Esecuzione Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 2350 2950 kPa 10 15 kPa 50 73 l/h 3450 4250 kPa 21 31 kPa 32 53 l 3.6 3.6 % 70/30 Condensatore, lato riscaldamento Scambiatore a piastre Inox AISI 316L, brasato Esecuzione l/h 1200 1500 kPa 6 9 kPa 38 31 l/h 1600 1950 Perdita di carico con W10/W35 incl. tubi flessibili kPa 8 10 Pressione residua con W10/W35 4) kPa 31 24 l 3.1 3.6 Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico (∆t 7,0 K con W10/W35) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) % 100 49 Dati tecnici HP GEO 10M.MT - 12M.MT Termopompa HP GEO ..M.MT 10M.MT 12M.MT Campo di impiego Sorgente termica: uscita acqua glicolata T min. °C -8 -8 Sorgente termica: uscita acqua T min. °C 3 3 min/max °C 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici 1 x 230 V / 50 Hz Tensione di esercizio, alimentazione kW 2.2 2.8 Fusibile esterno con resistenza elettrica AT 32 32 Fusibile esterno senza resistenza elettrica AT 32 32 Potenza nom. assorbita con B0/W35 PNT Corrente nom. resistenza elettrica I max A 9 9 Corrente nominale compressore I max. A 23.1 23.5 Corrente con rotore bloccato LRA A 100 114 Corrente allo spunto con avviatore progressivo VSA A 45 45 Potenza assorbita resistenza elettrica max. kW Potenza assorbita pompe di circolazione max. kW 0.25 0.45 Avviamenti ogni ora max. (-) 3 3 6/4/2 sec. Ritardo di avviamento dopo interruzione di corrente 60-120 Dimensioni / Raccordi / Vari kg Peso 120 125 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" Lwa dB(A) 41 45 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 Punto di commutazione pressostato acqua glicolata p bar Off 0.65 / On 0.80 Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 50 580x580x1130 Secondo EN255 Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Dati tecnici HP GEO 07M.HT2 07M.HT2 Termopompa HP GEO ..M.HT2 Tipo di costruzione Esecuzione compatta alta temperatura Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 secondo EN 14511 Dati normalizzati termopompe acqua Potenza frigorifera con W10 2) Coefficiente di rendimento con W10 secondo EN 14511 Qh kW 7 6.6 Qo kW 5.4 4.2 Pel kW 1.6 2.4 COP (-) 4.2 2.8 Qh kW 9.8 9.2 Qo kW 8.0 6.4 Pel kW 1.8 2.6 COP (-) 5.5 3.5 Refrigerante R 134a Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda W50 1) Potenza termica con W10 Potenza el. assorbita con W10 W35 3) DN 32 l 1.4 kg 2.0 m 2x60 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico nom. (∆t 3,0 K con B0/W35) l/h 1700 Perdita di carico con B0/W35 incl. tubi flessibili kPa 10 kPa 42 l/h 2500 kPa 20 Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/ W35) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) kPa 18 l 3.6 % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico nom. (∆t 5,0 K con W10/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 6) 7) 4) Flusso volumetrico nom. (∆t 5,0 K con B0/W35) 6) Perdita di carico con W10/W35 incl. tubi flessibili Pressione residua con W10/W35 7) 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua) l/h 1200 kPa 9 kPa 35 l/h 1700 kPa 12 kPa 26 l 3.1 % 100 Campo di impiego Sorgente termica: uscita acqua glicolata T min °C -8 Sorgente termica: uscita acqua T min °C 3 min/max °C 20/65 Temperatura mandata riscaldamento 51 Dati tecnici HP GEO 07M.HT2 07M.HT2 Termopompa HP GEO ..M.HT2 Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 1 x 230V/50Hz PNT kW 2.8 Fusibile esterno con resistenza elettrica AT 32 Fusibile esterno senza resistenza elettrica AT 32 Corrente nom. resistenza elettrica l max. A 9 Corrente nominale compressore I max. A 23.5 Corrente con rotore bloccato LRA A 114 Corrente allo spunto con avviatore progressivo VSA A 45 Potenza assorbita resistenza elettrica Pmax. kW 6/4/2 Potenza assorbita pompe di circolazione Pmax. kW 0.22 max. (-) 3 sec. 60-120 kg 115 LxPxA mm 580x580x1130 Raccordo circuito riscaldamento FF pollici 1" Raccordo circuito acqua glicolata FF pollici 1" Lwa dB(A) 45 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 Punto di commutazione pressostato acqua glicolata p bar Off 0,65 / On 0,80 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente Dimensioni / Raccordi / Vari Peso Dimensioni Livello di potenza sonora 1) 2) 3) 4) 5) 6) 7) 52 Secondo EN 14511 (* misurato presso il Centro di collaudo termopompe WPZ) Pompa di circolazione inclusa Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS Prevalenza residua riferita allo stadio massimo Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) Con flusso volumetrico nominale Dati tecnici HP GEO R 05/05T.MT - 08/08T.MT Termopompa HP GEO R ..T.MT 05/05T.MT Tipo di costruzione 06/06T.MT 08/08T.MT Esecuzione compatta reversibile Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 W35 W35 W35 Qh kW 5.4 6.5 8.2 Qo kW 4.2 5.0 6.3 Pel kW 1.2 1.5 1.9 COP (-) 4.5 4.3 4.4 W7 W7 W7 Regime raffrescamento Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con B35 Potenza el. assorbita con B35 2) Coefficiente di rendimento con B35 Qc kW 5.2 6.8 8 Pel kW 1.2 1.5 1.8 COP (-) 4.4 4.4 4.4 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1 1.1 1.1 kg 1.4 1.6 1.7 m 93 111 2x70 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) l/h 1350 1600 2000 Perdita di carico con B0/W35 incl. tubi flessibili kPa Pressione residua con B0/W35 4) kPa 11 6 15 29 30 48 l/h 1850 2300 2900 Dissipazione calore kW 6.1 7.9 9.4 Flusso volumetrico (∆t 5,0 K con B35/W7) l/h 1150 1500 1800 kPa 5 5 7 kPa 37 32 57 l 2.3 3.1 3.1 Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Regime raffrescamento Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) l/h 650 800 1000 kPa 2 5 6 kPa 48 43 40 l/h 900 1150 1400 kPa 7 6 8 kPa 40 38 33 l 2.3 2.6 2.6 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) % 100 53 Dati tecnici HP GEO R 05/05T.MT - 08/08T.MT Termopompa HP GEO R ..T.MT 05/05T.MT 06/06T.MT 08/08T.MT Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 -8 -8 Sorgente termica: uscita acqua Tmin °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 3 x 400 V / 50 Hz PNT kW 1.2 1.5 1.9 Fusibile esterno con resistenza elettrica AT 16 16 20 Fusibile esterno senza resistenza elettrica AT 10 10 13 Corrente nom. resistenza elettrica I max. A 9 9 9 Corrente nominale compressore I max. A 4.2 5.1 6.3 Corrente con rotore bloccato LRA A 24 32 40 Corrente allo spunto con avviatore progressivo VSA A 12.5 12.75 15.75 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.13 0.13 0.25 max. (-) 3 3 3 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente 6/4/2 sec. 60-120 Dimensioni / Raccordi / Vari Peso Dimensioni kg 120 125 125 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 41 41 41 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Livello di potenza sonora 580x580x1130 Off 0.65 / On 0.80 1) Secondo EN255, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Pompa di circolazione inclusa 3) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 4) Prevalenza residua riferita allo stadio massimo 5) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 54 Dati tecnici HP GEO R 10/09T.MT - 14/12T.MT Termopompa HP GEO R ..T.MT 10/09T.MT Tipo di costruzione 12/12T.MT 14/12T.MT Esecuzione compatta reversibile Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 W35 W35 W35 Qh kW 9.6 12.0 14.4 Qo kW 7.4 9.2 11.1 Pel kW 2.2 2.8 3.3 COP (-) 4.5 4.3 4.3 W7 W7 W7 Regime raffrescamento Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con B35 Potenza el. assorbita con B35 2) Coefficiente di rendimento con B35 Qc kW 9.4 11.6 14.2 Pel kW 2.1 2.6 3.2 COP (-) 4.4 4.5 4.4 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1.1 1.36 1.42 kg 2 2.3 2.7 m 2x82 2x102 3x82 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) l/h 2350 2950 3500 kPa 10 15 14 kPa 50 73 72 l/h 3450 4250 4950 Dissipazione calore kW 11.0 13.6 16.6 Flusso volumetrico (∆t 5,0 K con B35/W7) l/h 2100 2600 3200 kPa 7 10 10 kPa 55 80 78 l 3.6 3.6 4.1 Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Regime raffrescamento Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 7,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) l/h 1200 1500 1750 kPa 6 9 10 kPa 38 31 27 l/h 1600 2000 2450 kPa 6 12 9 kPa 33 22 20 l 3.1 3.1 3.6 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) % 100 55 Dati tecnici HP GEO R 10/09T.MT - 14/12T.MT Termopompa HP GEO R ..T.MT 10/09T.MT 12/12T.MT 14/12T.MT Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 -8 -8 Sorgente termica: uscita acqua Tmin °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 3 x 400 V / 50 Hz PNT kW 2.2 2.8 3.3 Fusibile esterno con resistenza elettrica AT 20 20 25 Fusibile esterno senza resistenza elettrica AT 13 16 20 Corrente nom. resistenza elettrica I max. A 9 9 9 Corrente nominale compressore I max. A 7 10 11 Corrente con rotore bloccato LRA A 46 50 66 Corrente allo spunto con avviatore progressivo VSA A 17.5 25 27.5 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.25 0.45 0.45 max. (-) 3 3 3 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente 6/4/2 sec. 60-120 Dimensioni / Raccordi / Vari Peso Dimensioni kg 130 135 140 580x580x1130 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 43 45 48 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Livello di potenza sonora Off 0.65 / On 0.80 1) Secondo EN255, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Pompa di circolazione inclusa 3) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 4) Prevalenza residua riferita allo stadio massimo 5) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 56 Dati tecnici HP GEO R 05/05M.MT - 08/08M.MT Termopompa HP GEO R ..M.MT 05/05M.MT Tipo di costruzione 06/06M.MT 08/08M.MT Esecuzione compatta reversibile monofase Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 W35 W35 W35 Qh kW 5.4 6.5 8.2 Qo kW 4.2 5.0 6.3 Pel kW 1.2 1.5 1.9 COP (-) 4.5 4.3 4.4 W7 W7 W7 Regime raffrescamento Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con B35 Potenza el. assorbita con B35 2) Coefficiente di rendimento con B35 Qc kW 5.2 6.8 8 Pel kW 1.2 1.5 1.8 COP (-) 4.4 4.4 4.4 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1 1.1 1.1 kg 1.4 1.6 1.7 m 93 111 2x70 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) l/h 1350 1600 2000 kPa 11 6 15 kPa 29 30 48 l/h 1850 2300 2900 kW 6.1 7.9 9.4 Regime raffrescamento Dissipazione calore Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) l/h 1150 1500 1800 kPa 5 5 7 kPa 37 32 57 l 2.3 3.1 3.1 % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 5,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) l/h 650 800 1000 kPa 2 5 6 kPa 48 43 40 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) l/h 900 1150 1400 kPa 7 6 8 kPa 40 38 33 l 2.3 2.6 2.6 % 100 57 Dati tecnici HP GEO R 05/05M.MT - 08/08M.MT Termopompa HP GEO R ..M.MT 05/05M.MT 06/06M.MT 08/08M.MT Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 -8 -8 Sorgente termica: uscita acqua Tmin °C 3 3 3 min/max °C 20/55 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 1 x 230 V / 50 Hz PNT kW 1.2 1.5 1.9 Fusibile esterno con resistenza elettrica AT 32 32 32 Fusibile esterno senza resistenza elettrica AT 16 20 25 Corrente nom. resistenza elettrica I max. A 9 9 9 Corrente nominale compressore I max. A 11.4 14.8 17.3 Corrente con rotore bloccato LRA A 47 61 76 Corrente allo spunto con avviatore progressivo VSA A 45 45 45 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.13 0.13 0.25 max. (-) 3 3 3 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente 6/4/2 sec. 60-120 Dimensioni / Raccordi / Vari Peso Dimensioni kg 120 125 125 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" 1" Lwa dB(A) 41 41 41 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 3 Punto di commutazione pressostato acqua glicolata p bar Livello di potenza sonora 580x580x1130 Off 0.65 / On 0.80 1) Secondo EN255, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Pompa di circolazione inclusa 3) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 4) Prevalenza residua riferita allo stadio massimo 5) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 58 Dati tecnici HP GEO R 10/09M.MT - 12/11M.MT Termopompa HP GEO R ..M.MT 10/09M.MT Tipo di costruzione 12/11M.MT Esecuzione compatta reversibile monofase Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 W35 W35 Qh kW 9.6 12.0 Qo kW 7.4 9.2 Pel kW 2.2 2.8 COP (-) 4.5 4.3 W7 W7 Regime raffrescamento Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con B35 Potenza el. assorbita con B35 2) Coefficiente di rendimento con B35 Qc kW 9.4 11.6 Pel kW 2.1 2.6 COP (-) 4.4 Refrigerante Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 4.5 R 407 c 3) DN 32 l 1.1 1.36 kg 2 2.3 m 2x102 3x82 Evaporatore, lato acqua glicolata Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 3,0 K con B0/W35) l/h 2350 2950 kPa 10 15 kPa 50 73 l/h 3450 4250 Dissipazione calore kW 11 13.6 Flusso volumetrico (∆t 5,0 K con B35/W7) l/h 2100 2600 kPa 7 10 kPa 55 80 l 3.6 3.6 Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Regime raffrescamento Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 4) Capienza, incl. tubi flessibili Fluido di lavoro (acqua/glicole etilenico) 5) % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 5,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 4) l/h 1200 1500 kPa 6 9 kPa 38 31 l/h 1600 2000 kPa 6 12 kPa 33 22 l 3.1 3.1 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) % 100 59 Dati tecnici HP GEO R 10/09M.MT - 12/11M.MT Termopompa HP GEO R ..M.MT 10/09M.MT 12/11M.MT Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 -8 Sorgente termica: uscita acqua Tmin °C 3 3 min/max °C 20/55 20/55 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 1 x 230 V / 50 Hz PNT kW 2.2 2.8 Fusibile esterno con resistenza elettrica AT 32 32 Fusibile esterno senza resistenza elettrica AT 32 32 Corrente nom. resistenza elettrica I max. A 9 9 Corrente nominale compressore I max. A 23.1 23.5 Corrente con rotore bloccato LRA A 100 114 Corrente allo spunto con avviatore progressivo VSA A 45 45 Potenza assorbita resistenza elettrica Pmax. kW Potenza assorbita pompe di circolazione Pmax. kW 0.25 0.45 max. (-) 3 3 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente 6/4/2 sec. 60-120 Dimensioni / Raccordi / Vari Peso Dimensioni kg 130 135 LxPxA mm Raccordo circuito riscaldamento FF pollici 1" 1" Raccordo circuito acqua glicolata FF pollici 1" 1" Lwa dB(A) 43 45 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 3 Punto di commutazione pressostato acqua glicolata p bar Livello di potenza sonora 580x580x1130 Off 0.65 / On 0.80 1) Secondo EN255, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Pompa di circolazione inclusa 3) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 4) Prevalenza residua riferita allo stadio massimo 5) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 60 Dati tecnici HP GEO R 17/16T.HT1 Termopompa HP GEO R ..T.HT1 17/16T.HT1 Tipo di costruzione Esecuzione compatta reversibile Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) Potenza termica con B0 Potenza frigorifera con B0 Potenza el. assorbita con B0 2) Coefficiente di rendimento con B0 W35 Qh kW 17.7 Qo kW 13.7 Pel kW 4.0 COP (-) 4.5 Regime raffrescamento W7 Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con W35 Potenza el. assorbita con B35 2) Coefficiente di rendimento con B35 Qc kW 16.6 Pel kW 3.7 COP (-) 4.5 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 3) DN 32 l 1.57 kg 3.7 m 3x102 Evaporatore, lato acqua glicolata Esecuzione 1) Ohne Umwälzpumpe Flusso volumetrico (∆t 3,0 K con B0/W35) 2) Messwert um die Wärmepumpe gemittelt (Freifeld) Perdita di carico con ist B0/W35 incl. tubi 3) Restförderdruck angegeben beiflessibili grösster Stufe Pressione residua con B0/W35 4) Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Scambiatore a piastre Inox AISI 316L, brasato l/h 4350 kPa 13 kPa 70 l/h 6000 Regime raffrescamento Dissipazione calore kW 20.3 1) Ohne Umwälzpumpe Flusso volumetrico (∆t 5,0 K con B35/W7) 2) Messwert um die Wärmepumpe gemittelt (Freifeld) Perdita di carico con B35/W7 incl. tubi flessibili 3) Restförderdruck ist angegeben bei grösster Stufe Pressione residua con B35/W7 4) l/h 3800 kPa 8 kPa 77 l 5.3 % 70/30 Capienza, incl. tubi flessibili Weitere Technische Daten siehe T30-T44 Fluido di lavoro (acqua/glicole etilenico) 5) Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico (∆t 5,0 K con B0/W35) 6) Perdita di carico con B0/W35 incl. tubi flessibili Pressione residua con B0/W35 7) 4) l/h 3050 kPa 7 kPa 29 l/h 2850 kPa 6 kPa 34 l 6.2 % 100 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) 6) Perdita di carico con B35/W7 incl. tubi flessibili Pressione residua con B35/W7 Capienza, incl. tubi flessibili Fluido di lavoro (acqua) 4) 7) 61 Dati tecnici HP GEO R 17/16T.HT1 Termopompa HP GEO R ..T.HT1 17/16T.HT1 Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 Sorgente termica: uscita acqua Tmin °C 3 min/max °C 20/60 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 1 x 230 V / 50 Hz PNT kW 4.0 Fusibile esterno con resistenza elettrica AT 25 Fusibile esterno senza resistenza elettrica AT 20 Corrente nom. resistenza elettrica I max. A 9 Corrente nominale compressore I max. A 15 Corrente con rotore bloccato LRA A 87 Corrente allo spunto con avviatore progressivo VSA A 37.5 Potenza assorbita resistenza elettrica Pmax. kW 6/4/2 Potenza assorbita pompe di circolazione Pmax. kW 0.48 max. (-) 3 sec. 60-120 kg 180 LxPxA mm 580x700x1130 Raccordo circuito riscaldamento FF pollici 1" Raccordo circuito acqua glicolata FF pollici 1" Lwa dB(A) 48 Pressione di esercizio max. (ac.glic./riscaldamento) p bar 3 Punto di commutazione pressostato acqua glicolata p bar Off 0.65 / On 0.80 Avviamenti ogni ora Ritardo di avviamento dopo interruzione di corrente Dimensioni / Raccordi / Vari 1) Ohne Umwälzpumpe 2) Messwert um die Wärmepumpe gemittelt (Freifeld) Peso 3) Restförderdruck ist angegeben bei grösster Stufe Dimensioni Livello di potenza sonora 1) Secondo EN14511, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Pompa di circolazione inclusa 3) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 4) Prevalenza residua riferita allo stadio massimo 5) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 6) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) 7) Con flusso volumetrico nominale 62 Dati tecnici HP GEO R 22/21T.HT1 - 43/45T.HT1 Termopompa HP GEO R ..T.HT1 22/21T.HT1 Tipo di costruzione 28/30T.HT1 35/35T.HT1 43/45T.HT1 Esecuzione normale alta temperatura reversibile Regime riscaldamento Dati normalizzati termopompe acqua glicolata 1) W35 W35 W35 W35 Potenza termica con B0 Qh kW 21.0 28.7 36.7 44.4 Potenza frigorifera con B0 Qo kW 16.4 22.2 28.4 34.4 Potenza el. assorbita con B0 Pel kW 4.6 6.5 8.3 10.0 COP (-) 4.6 4.4 4.4 4.4 W7 W7 W7 W7 Coefficiente di rendimento con B0 Regime raffrescamento Dati normalizzati termopompe acqua glicolata Potenza raffreddamento con B35 Qc kW 21.4 30.5 38.6 46.5 Potenza el. assorbita con B35 Pel kW 4.8 6.7 8.6 10.5 COP (-) 4.5 4.6 4.5 4.4 Coefficiente di rendimento con B35 Refrigerante R 407 c Olio circuito frigorifero Olio estere Quantità riempimento olio Quantità riempimento refrigerante Lunghezza sonda 2) DN 32 l 2.7 4 4.1 4.1 kg 4.7 6.3 6.8 8.7 m 4x92 5x99 6x106 7x109 1) Ohne Umwälzpumpe Evaporatore, lato acqua glicolata 2) Messwert um die Wärmepumpe gemittelt (Freifeld) Esecuzione 3) Restförderdruck ist angegeben bei grösster Stufe Flusso volumetrico (∆t 3,0 K con B0/W35) Scambiatore a piastre Inox AISI 316L, brasato l/h 5250 7100 9050 10950 kPa 9 11 14 19 l/h 6700 9000 12550 14950 Dissipazione calore kW 26.1 37.2 47.2 57.0 Flusso volumetrico (∆t 5,0 K con B35/W7) 1) Ohne Umwälzpumpe 2) Messwert um die Wärmepumpe gemittelt (Freifeld) Perdita di carico con B35/W7 incl. tubi flessibili 3) Restförderdruck ist angegeben bei grösster Stufe Capienza, incl. tubi flessibili l/h 4900 7000 8850 10700 kPa 8 9 11 11 l 10.8 14.2 16.5 18.8 Perdita di carico con B0/W35 incl. tubi flessibili Flusso volumetrico circ. intermedio (∆t 3,0 K con W10/W35) Regime raffrescamento Fluido di lavoro (acqua/glicole etilenico) 3) % 70/30 Condensatore, lato riscaldamento Esecuzione Scambiatore a piastre Inox AISI 316L, brasato Flusso volumetrico nom. (∆t 5,0 K con B0/W35) Perdita di carico con B0/W35 incl. tubi flessibili 4) 5) l/h 3600 4950 6350 7650 kPa 3 5 5 6 l/h 3700 5250 6650 8000 kPa 18 19 18 21 l 7.3 9.6 10.7 13 Regime raffrescamento Flusso volumetrico (∆t 5,0 K con B35/W7) Perdita di carico con B35/W7 incl. tubi flessibili Capienza, incl. tubi flessibili Fluido di lavoro (acqua) % 100 63 Dati tecnici HP GEO R 22/21T.HT1 - 43/45T.HT1 Termopompa HP GEO R ..T.HT1 22/21T.HT1 22/21T.HT1 28/30T.HT1 35/35T.HT1 Campo di impiego Sorgente termica: uscita acqua glicolata Tmin °C -8 -8 -8 -8 Sorgente termica: uscita acqua Tmin °C 3 3 3 3 min/max °C 20/60 20/60 20/60 20/60 Temperatura mandata riscaldamento Dati elettrici Tensione di esercizio, alimentazione Potenza nom. assorbita con B0/W35 3 x 400 V / 50 Hz PNT kW 4.6 6.5 8.3 10.0 AT 3 x 25 3 x 32 3 x 40 3 x 40 I max. A 21 21.0 25 32 Corrente con rotore bloccato LRA A 84 127.0 167 198 Corrente allo spunto con avviatore progressivo VSA A 52.5 52.5 62.5 80 Avviamenti ogni ora max. (-) 3 3 3 3 340 370 Fusibile esterno Corrente nominale Ritardo di avviamento dopo interruzione di corrente sec. 60-120 Dimensioni / Raccordi / Vari Peso Dimensioni kg 255 325 LxPxA mm FF pollici 1¼ 1¼ 1¼ 1¼ Raccordo acqua glicolata FF 1) Ohne circuito Umwälzpumpe 2) Messwert um sonora die Wärmepumpe gemittelt (Freifeld) Livello di potenza Lwa 3) Restförderdruck ist angegeben bei grösster Stufe Pressione di esercizio max. (ac.glic./ p riscaldamento) pollici 1½ 1½ 1½ 1½ dB(A) 57 59 59 62 bar 3 3 3 3 Raccordo circuito riscaldamento Punto di commutazione pressostato acqua glicolata p bar 670x950x1020 Off 0.65 / On 0.80 1) Secondo EN14511, i dati normalizzati delle termopompe acqua e i flussi volumetrici corrispondono a quelli del modello analogo in esecuzione normale. 2) Lunghezza richiesta delle sonde geotermiche per condizioni geologiche normali (45 W/m), senza produzione ACS 3) Acqua/glicole etilenico: cp = ~3.6 [KJ/kg*K], ρ = ~1.05 [kg/dm3] (ASHRAE) 4) Δt max= 10 K, con produzione ACS Δtmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*Δt[K]*ρ[kg/l])*3600) 5) Con flusso volumetrico nominale 64 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO 05T.MT HP GEO 06T.MT HP GEO 08T.MT HP GEO 10T.MT HP GEO 12T.MT HP GEO 14T.MT sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Giannello Lupidi Direzione Direzione Direttore Divisione 65 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO R 05/05T.MT HP GEO R 06/06T.MT HP GEO R 08/08T.MT HP GEO R10/09T.MT HP GEO R 12/12T.MT HP GEO R 14/12T.MT sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Giannello Lupidi Direzione Direzione Direzione Direttore Divisione 58 66 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO 17T.HT1 HP GEO 22T.HT1 HP GEO 28T.HT1 HP GEO 35T.HT1 HP GEO 43T.HT1 sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direttore Divisione 67 57 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO R 17/16T.HT1 HP GEO R 22/21T.HT1 HP GEO R 28/30T.HT1 HP GEO R 35/35T.HT1 HP GEO R 43/45T.HT1 sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direzione Direttore Divisione 68 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO 05M.MT HP GEO 06M.MT HP GEO 08M.MT HP GEO 10M.MT HP GEO 12M.MT sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direzione Direzione Direttore Divisione 69 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO R 05/05M.MT HP GEO R 06/06M.MT HP GEO R 08/08M.MT HP GEO R 10/09M.MT HP GEO R 12/11M.MT sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direzione Direzione Direttore Divisione 70 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO 07T.HT2 HP GEO 11T.HT2 sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direzione Direzione Direttore Divisione 71 Dichiarazione di conformità DICHIARAZIONE DI CONFORMITÀ CE Il produttore: RIELLO S.p.A Indirizzo: 37045 Legnago dichiara che i seguenti prodotti: HP GEO 07M.HT2 sono conformi alle seguenti direttive: Direttive CE Direttiva Attrezzature a pressione Direttiva Bassa Tensione Direttiva Compatibilità elettromagnetica Norme europee armonizzate Biasca, 25 maggio 2010 Riello S.p.A. Direzione Giannello Lupidi Direzione Direzione Direzione Direzione Direzione Direttore Divisione 72 Annotazioni 73 Annotazioni 74 Annotazioni 75 Indicazioni per il corretto smaltimento del prodotto ai sensi della Direttiva Europea 2002/96/EC. Alla fine della sua vita utile il prodotto non deve essere smaltito insieme ai rifiuti urbani. Può essere consegnato presso gli appositi centri di raccolta differenziata predisposti dalle amministrazioni comunali, oppure presso i rivenditori che forniscono questo servizio. Smaltire separatamente un elettrodomestico consente di evitare possibili conseguenze negative per l’ambiente e per la salute derivanti da un suo smaltimento inadeguato e permette di recuperare i materiali di cui è composto al fine di ottenere un importante risparmio di energia e di risorse. Per rimarcare l’obbligo di smaltire separatamente gli elettrodomestici, sul prodotto e riportato il marchio del contenitore di spazzatura mobile barrato. RIELLO S.p.A. – 37045 Legnago (VR) - Italy Tel. +39 0442 630 111 – Fax +39 0442 22 378 – www. riello.it RIELLO SA Via Industria – 6814 Lamone – Lugano Switzerland Tel. +41(0)91 604 50 22 – Fax +41 (0)91 604 50 24 – email: [email protected] RIELLO NV/SA - Belgium Waverstraat 15 - 9310 Aalst -Moorsel Tel. +32 053769-030 – Fax +32 053789-440 Poiché l’azienda è costantemente impegnata nel continuo perfezionamento di tutta la sua produzione, le caratteristiche estetiche e dimensionali, i dati tecnici, gli equipaggiamenti e accessori, possono essere soggetti a variazione.