CONVERTITORE DI TENSIONE ALTERNATA CON ALIMENTAZIONE AUSILIARIA / ISOLAMENTO GALVANICO TRANSDUCER ALTERNATE VOLTAGE WITH AUXILIARY SUPPLY /WITH GALVANIC INSULATED Modello CTA CTA model CARATTERISTICHE GENERALI / GENERAL FEATURES GRANDEZZA MISURATA MEASURED VARIABLE VERSIONE VERSION tensione alternata alternate voltage con alimentazione ausiliaria with auxiliary supply VALORI NOMINALI DI INGRESSO (Vn) INPUT RATED VALUES 100V 100/ √ 3V 110V 110/ √ 3V 220V 220/ √ 3V 380V 500V 0….1.2Vn ± 30% Vn (zero soppresso / suppressed zero) ± 15% Vn (zero soppresso / suppressed zero) _ CAMPI DI MISURA MEASURING RANGES _ 0.8 …. 1.2 Vn CAMPO DI TARATURA CALIBRATION RANGE CAMPO DI VARIAZIONE (V) VARIATION RANGE SOVRACCARICO PERMANENTE CONTINUOUS OVERRLOAD SOVRACCARICO ISTANTANEO (1 sec.) INSTANTANEOUS OVERLOAD FREQUENZA NOMINALE (±5% fn) RATED FREQUENCY GRANDEZZA IN USCITA (lu - Vu) OUTPUT VARIABLE CAMPO DELLA VARIABILE D’USCITA: 0….1.2lun (mA) RANGE OF OUTPUT VARIABLE 0….1.2Vun (V) RESISTENZA DI CARICO (0…Rn) LOAD RESISTANCE 0 …. 1.2 Vn 1.2 Vn 2 Vn 50Hz (400Hz a richiesta / on request ) 60Hz corrente continua impressa o tensione continua direct current ( load – independent) or direct voltage 0….1mA-V 0….5mA-V 0….10mA-V 0….20mA 1….5mA-V 2….10mA-V 4….20mA-V 0…10V/lun (0…15V/lun a richiesta / on request ) 1...10 M Ω ( Vun ) PRECISIONE ACCURACY RESIDUO DI ALTERNATA RIPPLE TEMPO DI RISPOSTA RESPONSE TIME ALIMENTAZIONE AUSILIARIA c.a. (± 20%) a.c. AUXILIARY SUPPLY ALIMENTAZIONE AUSILIARIA c.c. (± 20 – 30 %) d.c. AUXILIARY SUPPLY AUTOCONSUMO AUTO-CONSUMPTION ± 1% (± 0.5% a richiesta / on request ) ≤ 1% (≤ ≤ 100 msec. a richiesta / on request ) ≤ 300 msec. (≤ ≤ 100 msec. a richiesta / on request ) 24V 100V 110V 220V 380V 12V 24V 48V 110V 250V tensione / voltage: ≤ 1VA alim. ausiliaria c.a. / a.c. aux. Supply : ≤4VA alim. ausiliaria c.a. / a.c. aux. Supply : ≤4VA ISOLAMENTO TRA: /INSULATION BETWEEN: INGRESSI – USCITA / INPUTS – OUTPUT INGRESSI – ALIM. AUSILIARIA c.a. / INPUTS – a.c. AUX. SUPPLY INGRESSI – ALIM. AUSILIARIA c.c. / INPUTS – d.c. AUX. SUPPLY USCITA – ALIM. AUSILIARIA c.a. / OUTPUT – a.c. AUX. SUPPLY USCITA – ALIM. AUSILIARIA c.c. / OUTPUT – d.c. AUX. SUPPLY TUTTI I MORSETTI – MASSA / ALL OF TERMINALS-EARTH PROVA IMPULSI / IMPULSIVE TEST PESO WEIGHT 4kV / 60 sec. 50Hz 4kV / 60 sec. 50Hz 2kV / 60 sec. 50Hz 4kV / 60 sec. 50Hz 2kV / 60 sec. 50Hz 4kV / 60 sec. 50Hz 5kV / 1.2 / 50µ sec. Kg. 0.590 SCHEMA D’INSERZIONE WIRING DIAGRAM DIMENSIONI DI INGOMBRO OVERALL DIMENSIONS 1 2 1 a b A B 2 3 4 5 6 + mA - + AUX COME ORDINARE / HOW TO ORDER: MODELLO / MODEL : CTA INGRESSO / INPUT : USCITA / OUTPUT : ALIMENTAZIONE / SUPPLY: FASE FT 02.26-rev0 pag.1 di 1 Italy Tel. ( 0039 ) 2 – 9986557 Fax. ( 0039 ) 2 – 9986425 Internet: http://www.fase.it E-MAIL: [email protected] Caratteristiche soggette a variazioni senza preavviso Specifications are subject to change without notice